uf_ugmgr.h
File description:

The Open C API interface to NX Manager.  This file describes the set of extra Open
API calls that are provided for use with NX Manager. These calls are not
available when using NX without NX Manager.

The functions fall into the following categories:
.      Encoding and decoding part file names
.      Invoking Team Center Engineering ITK functions
.      Managing associated files
.      Controlling default actions
.      Navigating the database

NOTE: The following is a related NX Manager function that is
described in uf.h file:
.        UF_is_ugmanager_active  
this routine checks to see if an NX Manager process is active.


 Data  Model
Writing  Open API Programs
File  Name Formats


Invoking Team Center Engineering ITK functions:
----------------------------
The Open API   UF_UGMGR_invoke_pdm_server  
enables you to make calls to (and receive output from) Team Center Engineering ITK functions

Controlling Default Actions:
----------------------------
A number of NX Manager Open APIs are provided that allow
you to control the default action of NX Manager when it creates
parts. For example, you can place all your newly created parts in a
default folder using the function UF_UGMGR_set_default_folder.

The functions for enquiring and setting default actions are:
 UF_UGMGR_set_config_rule  
 UF_UGMGR_set_default_folder  
 UF_UGMGR_list_config_rules  
 UF_UGMGR_ask_config_rule  

Associated files (e.g., shaded image files, Manufacturing-related files)
that belong to a part file can be managed through the NX Manager Open API.
The functions used to manage associated files are:

 UF_UGMGR_ask_dependent_files  
 UF_UGMGR_ask_export_directory  
 UF_UGMGR_ask_folder_name  
 UF_UGMGR_ask_user_role  
 UF_UGMGR_set_file_export_status  
 UF_UGMGR_ask_file_export_status  
 UF_UGMGR_set_user_role  

A group of functions is provided to enable an Open API program to navigate
the folder structure in the Team Center Engineering database.

A folder may contain other folders and parts. A part contains part revisions.
Folders, parts, and part revisions are known as database objects. Each object
that exists in the Team Center Engineering database is given an NX Manager database tag, a typed
tag UF_UGMGR_tag_t. This database tag is different from the normal NX
tag, the typed tag tag_t.

Note that when using the functions provided to navigate the database, in most
cases you pass to the function an NX Manager database tag UF_UGMGR_tag_t, not a
NX tag_t.

NOTE: If you pass a tag of type tag_t instead of a database tag UF_UGMGR_tag_t
to an NX Manager Open API, the function does not recognize the tag and
returns an error code.

Open APIs that can be used to navigate the Team Center Engineering database are given below:
 UF_UGMGR_ask_root_folder  
 UF_UGMGR_list_folder_contents  
 UF_UGMGR_ask_object_type  
 UF_UGMGR_ask_folder_name  
 UF_UGMGR_ask_part_tag  
 UF_UGMGR_ask_part_number  
 UF_UGMGR_list_part_revisions  
 UF_UGMGR_ask_part_revision_id  
 UF_UGMGR_list_part_rev_files  
 UF_UGMGR_ask_part_name_desc  
 UF_UGMGR_partrev_where_used  

*******************************************************************************/


#ifndef UF_UGMGR_H_INCLUDED
#define UF_UGMGR_H_INCLUDED


/***************************************************************************

 ***************************************************************************/


#include <uf_defs.h>
#include <uf_ugmgr_types.h>
#include <libufun_exports.h>
#include <uf_retiring.h>



/*****************************************************************************
Initializes the NX Manager Open API environment (in addition
to initializing the standard NX Open API environment)
and allocates an Open API execute license. If you do not call
UF_UGMGR_initialize, subsequent calls to Open API fail with
an error code of UF_err_program_not_initialized. This function must
be the first function that you call after you have declared your variables.

The arguments argc and argv are for external Open API programs only.
If you have an internal Open program, you may pass in 0 for argc,
and NULL for argv.

Environment: Internal  and  External

See Also:
Please refer to   example  

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_initialize(
int argc ,/* <I>
         Argument count.  This will typically be the argc parameter passed to
         your main program from the system.
         */

const char ** argv  /* <I>
                   Pointers to argument character strings.  This will typically
                   be the argv parameter passed to your main program from the
                   system.The strings must always be in the user's locale.
                   The input data should not be UTF8 data.
                   */

);

/*******************************************************************************
This routine finds the user's method for generating a new id for a part. The id
may be item_id for the default domain. For non-default domain, the id may be the
mfk id. The callback will be executed when the "Assign" button in the new part
dialog in NX Manager is selected. This callback can not contain a call to UF_initialize.
If it is called an error 1105002 "UF_initialize may not be called once UF_terminate is
called". It is necessary to call UF_UI_lock_ug_access prior to calling any
interactive API functions.


Environment: Internal and External

See Also:  UF_UGMGR_reg_new_id  
 UF_UGMGR_new_id_t  

History: Originally released in NX10.0
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_new_id   (
       UF_UGMGR_new_id_fn_t *func /* <I>
                                       Pointer to registered function to invoke
                                       */

                                      );

/*******************************************************************************
Registers the user's method for generating a new id for a part. The supplied
callback is executed in response to the "Assign" button in the new part dialog
in NX Manager. If a NULL is used then the program will be un-registered.
In the registered callback, a call to UF_UI_lock_ug_access is necessary prior
to calling any interactive API functions. Also - it is not necessary to call
UF_initialize in the callback. It will raise an error if called.

Note:  This routine, if registered, will be called in preference to the
existing Teamcenter user exit routine.

Environment: Internal and External

See Also:   UF_UGMGR_ask_new_id  
 UF_UGMGR_new_id_t  
Please refer to the   example  

History: Originally released in NX10.0
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_reg_new_id
   (
       UF_UGMGR_new_id_fn_t new_id_fn /* <I>
                                                Pointer to the user supplied
                                                registered Open callback
                                                */

   );

/*******************************************************************************
Finds the user's method for generating a new part revision name.  The supplied
callback is executed in response to the "Assign" button in the new part dialog
in NX Manager.  If a NULL is used then the program will be un-registered.
In the registered callback, a call to UF_UI_lock_ug_access is necessary prior
to calling any interactive API functions.  Also - it is not necessary to call
UF_initialize in the callback.  It will raise an error if called.

Note:  This routine, if registered, will be called in preference to the
existing Team Center Engineering user exit routine.

Environment:Internal and External

See Also:  UF_UGMGR_reg_new_part_rev  
 UF_UGMGR_new_part_rev_t  
See the   example  

History:This function was originally released in V15.0
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_new_part_rev
   (
       UF_UGMGR_new_part_rev_fn_t *func /* <I>
                                        Pointer to registered function to
                                        invoke.
                                        */

   );
/*******************************************************************************
Registers the user's method for generating a new part revision.  The supplied
callback is executed in response to the "Assign" button in the new part dialog
in NX Manager.  If a NULL is used then the program will be un-registered.
In the registered callback, a call to UF_UI_lock_ug_access is necessary prior
to calling any interactive API functions.  Also - it is not necessary to call
UF_initialize in the callback.  It will raise an error if called.

Note:  This routine, if registered, will be called in preference to the
existing Team Center Engineering user exit routine.

Environment: Internal and External

See Also:  UF_UGMGR_ask_new_part_rev  
 UF_UGMGR_new_part_rev_t  
See the   example  

History: This function was originally released in V15.0.
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_reg_new_part_rev
   (
       UF_UGMGR_new_part_rev_fn_t new_part_rev_fn
                                  /* <I>
                                  Pointer to the user supplied registered
                                  Open API program
                                  */

   );
/*******************************************************************************
Returns  the user's method for generating a new dataset name registered using
UF_UGMGR_reg_new_dataset_name.
Finds the user's method for generating a new dataset name.  The supplied
callback is executed in response to the "Assign" button in the new part dialog
in NX Manager.  If a NULL is used then the program will be un-registered.
In the registered callback, a call to UF_UI_lock_ug_access is necessary prior
to calling any interactive API functions.  Also - it is not necessary to call
UF_initialize in the callback.  It will raise an error if called.

Note:  This routine, if registered, will be called in preference to the
existing Team Center Engineering user exit routine.

Environment: Internal and External

See Also:   UF_UGMGR_new_dataset_name_t  
See the   example  

History: This function was originally released in V15.0.
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_new_dataset_name
   (
       UF_UGMGR_new_dataset_name_fn_t *func
                                      /* <I>
                                      Pointer to registered function
                                      to invoke
                                      */

  );
/*******************************************************************************
Registers the user's method for generating a new dataset name.  The supplied
callback is  executed in response to the "Assign" button in the New part or Save As dialog
when new non-master or CAE part is being created.
If a NULL is used then the program will be un-registered.
In the registered callback, a call to UF_UI_lock_ug_access is necessary prior
to calling any interactive API functions.  Also - it is not necessary to call
UF_initialize in the callback.  It will raise an error if called.

Note:  This routine, if registered, will be called in preference to the
existing Teamcenter user exit routine.

Environment:Internal and External

See Also:  UF_UGMGR_ask_new_dataset_name  
 UF_UGMGR_new_dataset_name_t  
See the   example  

History: This function was originally released in V15.0.
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_reg_new_dataset_name
   (
       UF_UGMGR_new_dataset_name_fn_t new_dataset_name_fn
                                      /* <I>
                                      Pointer to the user supplied
                                      registered Open API callback.
                                      */

);

/******************************************************************************
Encodes the input arguments into an NX Manager part file name. The
resultant part file name can then be used in any other Open API
subroutine that accepts a part file name (e.g., UF_PART_open,
UF_PART_new).  The following rules apply to the input arguments:

If you specify a value of NULL, the empty string "", or "master"
for the part_file_type argument, the function assumes that you
wish to encode the part as a master part file. In this case, the
part_file_name field should be specified as NULL or the empty
string, "".

If you specify a part file type of "specification" or "manifestation",
you must also specify a name for the specification or manifestation
part file.

The total combined length for the part_number, part_revision,
and part_file_name fields should not exceed 50 characters. In
addition, the maximum permissible length for the part_number
is 26 characters, 16 characters for the part_revision, and 32
characters for the part_file_name.

For the input part_number:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x
       And the encoded part filename would be containing the MFK.

This function should not be called for CPD shapeDesign parttype

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_encode_part_filename(
const char * part_number ,/* <I>
                   Part number.
                   */

const char * part_revision ,/* <I>
                     Part revision.
                     */

const char * part_file_type ,/* <I>
                      Part file type. Should be NULL, the empty
                      string "", "master", "specification" or
                      "manifestation". Note that "master",
                      "specification", and "manifestation" must be
                       spelt using lower-case letters only.
                      */

const char * part_file_name ,/* <I>
                      Part file name. Only required if the
                      part_file_type is "specification" or
                      "manifestation".
                      */

char encoded_name[ MAX_FSPEC_BUFSIZE ]  /* <O>
                    Encoded form of part file name. Declare this
                    parameter with array size
                    MAX_FSPEC_BUFSIZE.
                    */

);


/******************************************************************************
Decodes the specified NX Manager part file name into its constituent
elements - the part number, part revision, part file type, and part file
name. If a particular element is not present in the encoded input
string, the corresponding output argument is the empty string "".
The encoded_name input argument can be any one of the following:

An internal form string such as that returned from the function
UF_UGMGR_encode_part_filename or other functions that
return part filenames (e.g. UF_PART_ask_part_name).

A command line input form string such as that returned from
UF_UGMGR_convert_file_name_to_cli.

A string input by a user of an Open API program.

For the output part_number:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

Environment: Internal  and  External

See Also:
 UF_UGMGR_encode_part_filename  
 UF_UGMGR_convert_file_name_to_cli  
Please refer to the   example  

History: This function was originally released in NX 5.0.and is mandatory if Longer IDs functionality is enabled NX/Manager
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_decode_part_file_name(
const char *encoded_name ,/* <I>
                    Encoded form of the part file name. Declare
                    this parameter with array size
                    MAX_FSPEC_BUFSIZE.
                    */

char part_number[UF_UGMGR_PARTNO_BUFSIZE] ,/* <O>
                   Part number. Declare this parameter with array
                   size UF_UGMGR_PARTNO_BUFSIZE.
                   */

char part_revision[UF_UGMGR_PARTREV_BUFSIZE] ,/* <O>
                     Part revision. Declare this parameter with array
                     size UF_UGMGR_PARTREV_BUFSIZE.
                     */

char part_file_type[UF_UGMGR_FTYPE_BUFSIZE] ,/* <O>
                      Part file type. Declare this parameter with array
                      size UF_UGMGR_FTYPE_BUFSIZE.
                      */

char part_file_name[UF_UGMGR_FNAME_BUFSIZE]  /* <O>
                      Part file name. Declare this parameter with
                      array size UF_UGMGR_FNAME_BUFSIZE.
                      */

);


/*******************************************************************************
Passes program control to Team Center Engineering, thereby allowing you to make
Team Center Engineering ITK calls.  When the Open API UF_UGMGR_invoke_pdm_server
is called, it makes a call to the function USER_invoke_pdm_server the Team Center
Engineering user exit shared library. Note the difference between these function
names.

In your ITK program, the USER_invoke_pdm_server() function
should contain all the ITK functions to implement the required
functionality. The function should be linked into the shared library
libuser_exits.sl. Refer to the Information Manager Integration Tool Kit
Reference Manual for additional information about implementing
these ITK functions using User Exits.

The required prototype for the function USER_invoke_pdm_server() is:

extern void USER_invoke_pdm_server(     int     input_code,
                                       char    *input_string,
                                       int     *output_code,
                                       char    **output_string);

The USER_invoke_pdm_server() ITK function has the same
arguments as the UF_UGMGR_invoke_pdm_server Open API function.

The output_string argument must be allocated in the ITK function
USER_invoke_pdm_server() using the C programming language
malloc() function, and freed in the UF_UGMGR_invoke_pdm_server
Open API code by calling UF_free().

The input_code argument to USER_invoke_pdm_server can be used as a switch,
so that you may call a different ITK function depending upon the value of
input_code.  When the USER_invoke_pdm_server function terminates, program
control returns back from your ITK program to your Open API
program. You may specify two arguments to return to your Open
API program - an integer output_code and a string output_string.

Suppose that you have na Open API program from which you wish
to call an Team Center Engineering ITK program.  The ITK program takes a part number as
input, and returns the date that the part was created or the date it
was modified, depending upon the value of the input_code argument to the
function USER_invoke_pdm_server().  This could be implemented as follows:

The Open API program asks the user for a part number, and then
calls the Open API UF_UGMGR_invoke_pdm_server(), that passes
control to the ITK function USER_invoke_pdm_server(). The values
returned from this ITK function are printed.

Environment: Internal  and  External

See Also:
Please refer to the   example1  
and the   example2  

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_invoke_pdm_server(
int input_code ,/* <I>
               User defined input code passed to your Team Center Engineering
               ITK function USER_invoke_pdm_server().
               */

char * input_string ,/* <I>
                    User defined input string passed to your Team Center Engineering
                    ITK function USER_invoke_pdm_server().
                    */

int * output_code ,/* <O>
                  User defined return code that is returned from
                  the Team Center Engineering ITK USER_invoke_pdm_server()
                  function on completion of ITK calls.
                  */

char ** output_string  /* <OF>
                      User defined string that is returned from the
                      Team Center Engineering ITK USER_invoke_pdm_server()
                      function on completion of ITK calls.  This output string
                      will be allocated by your ITK program, and must be freed
                      by your Open API program by calling UF_free().
                      */

);

/******************************************************************************
Turns the export of associated files on or off. Associated files are
exported when the status argument to the function is true. If status is
set to false, no associated files are exported.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_file_export_status(
logical status  /* <I>
           Turns the export of files on or off. If set to TRUE,
           file export is enabled; if set to FALSE, file export
           is disabled.
           */

);

/******************************************************************************
Asks the status of export of associated files. If the status is TRUE, file export
is enabled and associated files can be exported, else file export is disabled
and no associated files can be exported.

Environment: Internal  and  External

History: Originally released in V17.0
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_file_export_status(
logical* status /* <O>
                   Ask the current status of export of files. If the status is
                   TRUE, file export is enabled, else file export is disabled.
               */


);

/*****************************************************************************
Sets the NX Manager user role to be used in filtering associated files
when they are exported from the Team Center Engineering database.
For example, if you specify Manufacturing as the user role, only
manufacturing-related files are exported from Team Center Engineering when you open a
part file from NX.

This should not be confused with the Team Center Engineering role, which is a separate concept.

For more information on the meaning and behaviour of the NX Manager role, see the
NX Manager online help documentation.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_user_role(
char * role  /* <I>
            User role.
            */

);


/******************************************************************************
Returns the current NX Manager user role to be used in filtering associated files
when they are exported from the Team Center Engineering database.
For example, if Manufacturing has been specified as the user role, only
manufacturing-related files are exported from Team Center Engineering when you open a
part file from NX.
For more information, see the NX Manager documentation.

This should not be confused with the Team Center Engineering role, which is a separate concept.

For more information on the meaning and behaviour of the NX Manager role, see the
NX Manager online help documentation.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_user_role(
char role[UF_UGMGR_ROLE_BUFSIZE]  /* <O>
            User role. Declare this parameter with array
            size UF_UGMGR_ROLE_BUFSIZE.
            */

);


/******************************************************************************
Asks for the name of the export directory (if one exists) in which all
dependent files associated with the specified part are placed.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_export_directory(
tag_t part_tag ,/* <I>
               NX part tag.
               */

char export_dir_name[ MAX_FSPEC_BUFSIZE ]  /* <O>
                       Export directory name. Declare this parameter
                       with array size MAX_FSPEC_BUFSIZE.
                       */

);

/******************************************************************************
Returns a list of the names of all dependent files and a count of the
dependent files that are associated with the specified encoded part file
name.

Environment:Internal and External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_dependent_files (
   char          encoded_name[ MAX_FSPEC_BUFSIZE ],
                 /* <I>
                 Encoded form of the part file name.
                 */

   int*          file_count,
                 /* <O>
                 Number of dependent files associated with the
                 specified part.
                 */

   char***       file_names
                 /* <OF>
                 List of the names of all the dependent files
                 associated with the specified part. The list
                 should be freed after use by calling
                 UF_free_string_array()
                 */

);

/*****************************************************************************
Sets the default folder into which parts are placed, given the database
tag of the folder.  You must specify the database tag of a folder that already
exists. This function does not create the folder if you specify the tag of
a non-existent folder.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_default_folder(
UF_UGMGR_tag_t folder  /* <I>
                      Database tag of the folder.
                      */

);

/******************************************************************************
Creates a new part in the database using a template part as the basis
for the part. If NULL is passed as the template name then the seed
part specified in the defaults file is used. This function also requires a
part type to be specified. If this is NULL then the part type specified
in the defaults file is used. If no default part type is specified, then a
type of 'Item' is used.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_new_part_from_template(
char encoded_part_name[ MAX_FSPEC_BUFSIZE ] ,/* <I>
                         Encoded form of the part file name. Declare this
                         parameter with array size MAX_FSPEC_BUFSIZE.
                         */

char* part_type ,/* <I>
                Part type
                */

char encoded_template_name[ MAX_FSPEC_BUFSIZE ] ,/* <I>
                             Encoded form of the template name. Declare this
                             parameter with array size MAX_FSPEC_BUFSIZE.
                             */

tag_t * part_tag  /* <O>
                 NX tag of the newly created part.
                 */

);

/******************************************************************************
Returns the database tag of the root folder for the current user. This
database tag is returned in the argument folder_tag. If an error
occurs, NULL is returned for the tag.

Environment: Internal and External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_root_folder (
   UF_UGMGR_tag_t     *folder_tag
                     /* <O>
                     The database tag of the root folder for the
                     current user.
                     */

   );

/******************************************************************************
Returns the database tag of the root folder for the specified user. This
database tag is returned in the argument folder_tag. If an error
occurs, NULL is returned for the tag.

Environment: Internal and External

History: First released in V19.0
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_user_folder (
   const char         *user_name, /* <I> the name of the user for whom the root folder tag is required */
   UF_UGMGR_tag_t     *folder_tag
                     /* <O>
                     The database tag of the root folder for the
                     specified user
                     */

   );

/*******************************************************************************
This function only returns tags of folders and parts contained in the
input folder.  You must specify the database tag of a folder
that already exists.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_list_folder_contents(
UF_UGMGR_tag_t folder ,/* <I>
                      Database tag of the folder whose contents you
                      wish to be listed.
                      */

int * count ,/* <O>
            The number of objects in the specified folder.
            */

UF_UGMGR_tag_t ** folder_contents  /* <OF>
                                 An array of database tags of the folder and
                                 part objects in the specified folder.
                                 This array must be freed after use using
                                 UF_free().
                                  */

);


/******************************************************************************
Queries the type of an object corresponding to the specified object
database tag. You must specify the tag of a valid database object.
Valid database objects are Folders, Parts and Part revisions.
If the tag specifies an invalid object, then object_type has a value of
UF_UGMGR_type_unknown.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_object_type(
UF_UGMGR_tag_t object ,/* <I>
                      Database tag of the object to query.
                      */

UF_UGMGR_object_type_t* object_type  /* <O>
                                    Type of object corresponding to the
                                    specified tag.
                                       UF_UGMGR_type_folder
                                       UF_UGMGR_type_part
                                       UF_UGMGR_type_part_revision
                                       UF_UGMGR_type_unknown.
                                    */

);

/******************************************************************************
Finds the name of the folder corresponding to the specified database
folder tag. You must specify the tag of a folder that already exists.

Environment: Internal and External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_folder_name (
   UF_UGMGR_tag_t        folder,
                         /* <I>
                         Database tag of the folder whose name we wish to know
                         */

   char                  folder_name[UF_UGMGR_NAME_BUFSIZE]
                         /* <O>
                         Name corresponding to the specified folder tag.
                         Declare this parameter with array size
                         UF_UGMGR_NAME_BUFSIZE.
                         */

   );

/******************************************************************************
Finds the tag of a part in the database corresponding to the specified
part number.
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

If the function is successful, the output
argument contains the database tag of the part. If the function is
unsuccessful, then the output argument is UF_UGMGR_null_tag.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_part_tag(
char * part_number ,/* <I>
                   Part number.
                   */

UF_UGMGR_tag_t * database_part_tag  /* <O>
                                   Database tag of the part corresponding to
                                   the specified part number.
                                   */

);

/*******************************************************************************
Finds the part number corresponding to the specified database part
tag. You must specify the tag of a part that already exists in the Team Center Engineering
database.

For the output part_number:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_part_number(
UF_UGMGR_tag_t part ,/* <I>
                    Database tag of the part to query.
                    */

char part_number[UF_UGMGR_NAME_BUFSIZE]  /* <O>
                   Part number corresponding to the specified
                   database part tag. Declare this parameter with
                   array size UF_UGMGR_NAME_BUFSIZE.
                   */

);

/*******************************************************************************
Asks for the number of revisions of a specified part and obtains a list
of database tags of all of the part revisions.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_list_part_revisions(
UF_UGMGR_tag_t part ,/* <I>
                    Database tag of the part to query.
                    */

int * revision_count ,/* <O>
                     Number of revisions of the specified part.
                     */

UF_UGMGR_tag_t ** revisions  /* <OF>
                            Array of database tags of all the revisions of
                            the specified part. The array must be freed
                            after use by calling UF_free().
                            */

);

/*******************************************************************************
Finds the name of the part revision (i.e.. the part revision id)
corresponding to the specified database tag of the part revision.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_part_revision_id(
UF_UGMGR_tag_t part_revision ,/* <I>
                             Database tag of the part revision.
                             */

char revision_id[UF_UGMGR_NAME_BUFSIZE]  /* <O>
                   Name of the part revision corresponding to the
                   specified part revision tag. Declare this
                   parameter with array size
                   UF_UGMGR_NAME_BUFSIZE.
                   */

);

/*******************************************************************************
Finds the number, list of names, and list of file types of non-master part
files that a specified part revision contains. The possible file types are
"specification" and "manifestation".

For example, a part revision may have two non-master files of type
"specification" named "drawing001" and "drawing002", and one file
of type "manifestation" called "NCtoolpath001". The output
arguments of the function store the following information:

file_count:     3
file_types:     specification   specification   manifestation
file_names:     drawing001      drawing002      NCtoolpath001

Elements of the file_types and file_names arrays
correspond (e.g., the third element of the file_types array is
"manifestation-->that corresponds to the third element of the
file_names array "NCtoolpath001").

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_list_part_rev_files(
UF_UGMGR_tag_t part_revision ,/* <I>
                             Part revision.
                             */

int * file_count ,/* <O>
                 Number of files.
                 */

char *** file_types ,/* <OF>
                    Array of file types. The array must be freed
                    after use by calling UF_free_string_array().
                    */

char *** file_names  /* <OF>
                    Array of file names. The array must be freed
                    after use by calling UF_free_string_array().
                    */

);

/*******************************************************************************
Adds the specified object to the specified folder. You may add only
folders or parts to the specified folder.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_add_to_folder(
UF_UGMGR_tag_t object_to_add ,/* <I>
                             Database tag of the object to add to the
                             specified folder.
                             */

UF_UGMGR_tag_t folder  /* <I>
                      Database tag of the folder in which to place the
                      object.
                      */

);

/*******************************************************************************
Returns the total number of configuration rules available in your
system, and a list of the names of all these configuration rules.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_list_config_rules(
int * count ,/* <O>
            Number of configuration rules.
            */

char *** config_rules  /* <OF>
                      Array of the names of all the configuration
                      rules. The array must be freed after use by
                      calling UF_free_string_array().
                      */

);

/*******************************************************************************
Returns your current configuration rule.

Environment: Internal and External

See Also:
Please refer to the   example  

History:
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_config_rule (
   char          current_rule[UF_UGMGR_NAME_BUFSIZE]
                 /* <O>
                 Your current configuration rule. Declare this
                 parameter with array size
                 UF_UGMGR_NAME_BUFSIZE.
                 */

   );

/*******************************************************************************
Sets the current configuration rule to be the specified rule. The
specified configuration rule must be valid. A list of valid configuration
rules can be obtained by calling the Open API UF_UGMGR_list_config_rules.

Environment: Internal and External

See Also:  UF_UGMGR_list_config_rules  
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_config_rule (
   char*         config_rule
                 /* <I>
                 Configuration rule.
                 */

   );

/*******************************************************************************
Finds the database tag of the configured revision of a specified part.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_configured_rev(
UF_UGMGR_tag_t database_part_tag ,/* <I>
                                 Database tag of the part whose configured
                                 revision we wish to find out.
                                 */

UF_UGMGR_tag_t * part_revision  /* <O>
                               Database tag of the configured revision of the
                               specified part.
                               */

);

/*******************************************************************************
Finds the database tag of the child part revision in an Assembly
using the immediate parent revision tag and child part tag  as the input.
If the parent assembly is precise, returns the precise configured
item revision tag of child part.  If the parentrev_tag is NULL_TAG
the child_part_rev will be the revision configured as per the Revision rule.

Environment: Internal  and  External

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_find_configured_rev(
UF_UGMGR_tag_t   parentrev_tag , /* <I>
                                   Database tag of the precise parent
                                   revision whose child part's revision
                                   we wish to find out. If passed a NULL_TAG,
                                   the child revsion returned will be based
                                   on revision rule
                                */

UF_UGMGR_tag_t   childpart_tag , /* <I>
                                   Database tag of the child part whose
                                   revision we wish to find out.
                                 */

UF_UGMGR_tag_t * child_part_rev   /* <O>
                                     Database tag of the configured revision
                                     of the child part in an Assembly.
                                 */

);

/*******************************************************************************
Finds the part name and part description of a part in the Team Center Engineering
database corresponding to the specified database part tag.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_part_name_desc(
UF_UGMGR_tag_t database_part_tag ,/* <I>
                                 Database tag of the part whose name and
                                 description we require.
                                 */

char part_name[UF_UGMGR_NAME_BUFSIZE] ,/* <O>
                 Part name. Declare this parameter with array
                 size UF_UGMGR_NAME_BUFSIZE.
                 */

char part_desc[UF_UGMGR_DESC_BUFSIZE]  /* <O>
                 Part description. Declare this parameter with
                 array size UF_UGMGR_DESC_BUFSIZE.
                 */

);

/******************************************************************************
Resets the name and description of a specified part in the database,
given the database tag of the part.  Both the part_name and the part_desc
arguments may be specified as NULL or the empty string "". If you specify
either argument as NULL or the empty string, the appropriate field is not
set in the database.

For example, if you specify part_name to be "engine" and part_desc
to be NULL, then only the part name field is set in the database.
The UF_UGMGR_set_part_name_desc function is used to reset the name and
description of the specified part in the database.  When a part is created
using the UF_PART_new function, the name and description of the part default
to the part number. It is only when the part has been saved that you may
alter its default name and description using the UF_UGMGR_set_part_name_desc
function.

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_part_name_desc(
UF_UGMGR_tag_t database_part_tag ,/* <I>
                                 Database tag of the part whose name and
                                 description we wish to reset.
                                 */

char * part_name ,/* <I>
                 Name of the part.
                 */

char * part_desc  /* <I>
                 Part description.
                 */

);


/*******************************************************************************
Converts a part file name from the command line input format to the
internal form. This routine is a null operation if not running
NX Manager and does not give an error.

In case of Default Domain:
       Master Part
       From: "@DB/<item_id>/<item_revision_id>"
       To:   "%UGMGR=V3.2 PH=itemUid PRH= itemRevUid PN= item_id PRN=item_revision_id RT="has shape" AT="UG master part file""

       Non-master Part
       From: "<@DB><separator><item_id><separator><item_revision_id><separator><Item Revision to dataset relation><dataset_name>"
       To:   "%UGMGR=V3.2 PH=itemUid PRH= itemRevUid PN= item_id PRN=item_revision_id AN="dataset name" RT="relation type" AT="Dataset type" AUID=appuid"

       e.g.,
       From:   "@DB/peters-part/A/spec/sheet1"
       To:     "%UGMGR=3.2 PN=Peters-part -PRN=A..."

In case of non-Default Domain:
       Master Part
       From:   "@DB/<MFK ID>/<item_revision_id>"
       To:     "%UGMGR=V3.2 PH=itemUid PRH= itemRevUid PN= MFK ID PRN=item_revision_id RT="has shape" AT="UG master part file""

       Non-master Part
       From:  "<@DB><separator><MFK ID><separator><item_revision_id><separator><Item Revision to dataset relation><dataset_name>"
       To:    "%UGMGR=V3.2 PH=itemUid PRH= itemRevUid PN= MFK ID PRN=item_revision_id AN="dataset name" RT="relation type" AT="Dataset type" AUID=appuid"

       e.g.,
       From:   "@DB/,=item_id=test123,object_type=testItemType/A"
       To:     "%UGMGR=V3.2 PH=iyDp59Kwx6sBFD PRH=iyOp59Kwx6sBFD PN=",=item_id=test123, object_type=testItemType" PRN=A AN=test-alt1 RT="has altrep" AT="UG alternative rep" AUID=C3Jp59Kwx6sBFD"

Note that UF_PART_new, UF_PART_open and UF_PART_save_as
accept an input part file name in the command line input format
without conversion.

Environment: Internal  and  External

See Also:   UF_UGMGR_convert_file_name_to_cli.  
Please refer to the   example  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_convert_name_from_cli(
const char * cli_name ,/* <I>
                      Command Line Input format, e.g.,
                      "@DB/peters-part/A/spec/sheet1"
                      Note: The separator used must not be a character which
                      is already used in the part name, part revision,
                      part file type or part file name.  Valid separators are
                      /@#$^&()|[]{}.
                      */


char ** internal_name  /* <OF>
                             Internal format "%UGMGR=3.2 PN=Peters-part
                             -PRN=A...".  The caller must free this string
                             by calling UF_free
                             */

);

/*******************************************************************************
Converts a part name from the internal format to the command line
input format. This routine is a null operation if not running
NX Manager.

In case of Default Domain:
       Master Part
       From:   "%UGMGR=V3.2 PH=itemUid PRH= itemRevUid PN= item_id PRN=item_revision_id RT="has shape" AT="UG master part file""
       To:     "@DB/<item_id>/<item_revision_id>"

       Non-master Part
       From:   "%UGMGR=V3.2 PH=itemUid PRH= itemRevUid PN= item_id PRN=item_revision_id AN="dataset name" RT="relation type" AT="Dataset type" AUID=appuid"
       To:     "<@DB><separator><item_id><separator><item_revision_id><separator><Item Revision to dataset relation><dataset_name>"

       e.g.,
       From:   "%UGMGR=3.2 PN=Peters-part -PRN=A..."
       From:   "@DB/peters-part/A/spec/sheet1"

In case of non-Default Domain:
       Master Part
       From:   "%UGMGR=V3.2 PH=itemUid PRH= itemRevUid PN= MFK ID PRN=item_revision_id RT="has shape" AT="UG master part file""
       To:     "@DB/<MFK ID>/<item_revision_id>"

       Non-master Part
       From:   "%UGMGR=V3.2 PH=itemUid PRH= itemRevUid PN= MFK ID PRN=item_revision_id AN="dataset name" RT="relation type" AT="Dataset type" AUID=appuid"
       To:     "<@DB><separator><MFK ID><separator><item_revision_id><separator><Item Revision to dataset relation><dataset_name>"

       e.g.,
       From:   "%UGMGR=V3.2 PH=iyDp59Kwx6sBFD PRH=iyOp59Kwx6sBFD PN=",=item_id=test123, object_type=testItemType" PRN=A AN=test-alt1 RT="has altrep" AT="UG alternative rep" AUID=C3Jp59Kwx6sBFD"
       To:     "@DB/,=item_id=test123,object_type=testItemType/A"

Environment: Internal  and  External

See Also:
Please refer to the   example  

History: This function was originally released in NX 5.0 and is mandatory if Longer IDs functionality is enabled NX/Manager
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_convert_file_name_to_cli(
const char * internal_name ,/* <I>
                           Internal format "%UGMGR=3.2
                           PN=Peters-part -PRN=A..."
                           */

char **cli_name             /* <OF>
                         Command Line Input format, e.g.,
                         "@DB/peters-part/A/spec/sheet1"
                         */

);

/*******************************************************************************
Validates the part number and revision identifiers selected for a new part
revision. This function may reject the supplied identifiers, accept them or
amend them. The action is reflected in the value of status. This function
calls the Team Center Engineering user exit function USER_validate_item_rev_id() to perform the
validation.

The user exit defines what constitutes a valid combination of number
and revision and depending on its implementation may take the type
of the part into account.

The behavior of the default stub supplied with Team Center Engineering as part of the
user exit library always returns a status of USER_valid_id, with the
output arguments modified_item_id and modified_rev_id set to an
empty string. In effect this represents unconditional acceptance of the
user input.

For the input and modified part_num:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

Environment: Internal  and  External

See Also:
Please refer to the   example  

History:
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_validate_part_rev(
const char part_num[UF_UGMGR_PARTNO_BUFSIZE] ,/* <I>
                    Part number. Declare this parameter
                    with array size UF_UGMR_PARTNO_SIZE+1.
                    */

const char part_rev[UF_UGMGR_PARTREV_BUFSIZE] ,/* <I>
                    Part revision. Declare this parameter
                    with array size UF_UGMR_PARTREV_SIZE+1.
                    */

const char * part_type, /* <I>
                       Type of part for which number and
                       revision is being validated.
                       */

char modified_part_num[UF_UGMGR_PARTNO_BUFSIZE] ,/* <O>
                       Modified part number. Not set if no
                       amendment.
                       */

char modified_part_rev[UF_UGMGR_PARTREV_BUFSIZE] ,/* <O>
                       Modified part revision. Not set if no
                       amendment.
                       */

UF_UGMGR_partno_status_t * status  /* <O>
                                  Enum code indicating,
                                  UF_UGMGR_partno_valid - accept
                                  UF_UGMGR_partno_invalid - reject
                                  UF_UGMGR_partno_modified -
                                  input modified.
                                  */

);
/*******************************************************************************
This routine generates a new part number by calling an Team Center Engineering user
exit, USER_new_item_id(). Depending on the implementation of the
user exit, the new part number may be based on an existing part. In
which case the number of that part must be supplied as the
basis_part_num parameter. The type of the part may also be required.
The behavior of the default user exit is to ignore the part type.
A logical is returned alongside the new part number. This logical
indicates whether the caller is allowed to change the part number
after it has been generated without calling this function. The behavior
of the default user exit is to return true at all times.

For the basis and new part_num:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

Environment: Internal  and  External

See Also:  UF_UGMGR_validate_part_rev  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_assign_part_number(
const char basis_part_num[UF_UGMGR_PARTNO_BUFSIZE] ,/* <I>
                          Number of a previous part that the new number
                          may be based on.
                          */

const char * part_type ,/* <I>
                       Type of part for which number is being requested.
                       May be NULL.
                       */

char part_num[UF_UGMGR_PARTNO_BUFSIZE] ,/* <O>
                                      Part number.
                                      */

logical * modifiable  /* <O>
                     Boolean; is part_num allowed to be modified by
                     caller.
                     */

);

/*******************************************************************************
This routine generates a new part revision identifier by calling an
Team Center Engineering user exit, USER_new_rev_id(). The part number for which a
new revision is required must be supplied. The type of the part may
also be supplied if required by the implementation of the user exit.
The new revision identifier is returned together with a logical
indicating whether the caller is allowed to change it without calling
this function.

For the input part_num for which revision is requested:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

Environment: Internal  and  External

See Also:  UF_UGMGR_validate_part_rev  

History:
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_assign_part_rev(
const char part_num[UF_UGMGR_PARTNO_BUFSIZE] ,/* <I>
                    Part number for which revision is requested.
                    */

const char * part_type ,/* <I>
                       Type of part for which new revision is requested.
                       May be NULL.
                       */

char part_rev[UF_UGMGR_PARTREV_BUFSIZE] ,/* <O>
              Part revision. Declare this parameter with array size
              UF_UGMR_PARTREV_SIZE + 1
              */

logical * modifiable  /* <O>
                     Boolean; is part_rev allowed to be modified by
                     caller.
                     */

);

/******************************************************************************
Generates the dataset name for a new non-master part based on a
call to the Team Center Engineering user exit, USER_new_dataset_name.

Environment: Internal and External

See Also:  UF_UGMGR_assign_copy_dset_name  
Please refer to the   example  

History:
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_assign_new_dset_name(
   const char  owner[UF_UGMGR_PARTNO_BUFSIZE],
               /* <I>
               String name of owning part
               */

   const char  owner_revision[UF_UGMGR_PARTREV_BUFSIZE],
               /* <I>
               String name of revision of owning part
               */

   const char *app_type,
              /* <I>
              String name of application type
              */

   const char *rel_type,
              /* <I>
              String name of relation type
              */

   const char *basis_string,
              /* <I>
              String name of default name (may be an empty string)
              */

   char        model_name[UF_UGMGR_NAME_BUFSIZE],
               /* <O>
               String name of new dataset
               */

   logical    *modifiable
              /* <O>
              Whether result is user modifiable
              */

);

/*******************************************************************************
Generates the dataset name for a copied non-master part based on
a call to the Team Center Engineering user exit, USER_copied_dataset_name.

Environment: Internal and External

See Also:   UF_UGMGR_assign_new_dset_name.  
Please refer to the   example  

History: This function was originally released in V15.0
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_assign_copy_dset_name(
   const char  old_owner[UF_UGMGR_PARTNO_BUFSIZE],
               /* <I>
               String name of old owning part
               */

   const char  old_owner_revision[UF_UGMGR_PARTREV_BUFSIZE],
               /* <I>
               String name of revision of old owning part
               */

   const char *dataset,
              /* <I>
              String name of old dataset
              */

   const char *app_type,
              /* <I>
              String name of application type
              */

   const char *rel_type,
              /* <I>
              String name of relation type
              */

   const char  new_owner[UF_UGMGR_PARTNO_BUFSIZE],
               /* <I>
               String name of new owning part or empty string
               */

   const char  new_owner_revision[UF_UGMGR_PARTREV_BUFSIZE],
               /* <I>
               String name of revision of new owning
               part or empty string
               */

   char        model_name[UF_UGMGR_NAME_BUFSIZE],
               /* <O>
               String name of new dataset
               */

   logical    *modifiable
              /* <O>
              Whether result is user modifiable
              */

   );

/*******************************************************************************
To set a static to allow sub-dialogs to be shown in Interactive
User Function and GRIP only.

Environment: Internal

See Also:

History:
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_dialog_display
   (
       logical display /* <I>
                       TRUE to allow dialogs to display.  False if
                       dialogs are not to display.
                       */

   );

/******************************************************************************
*    Purpose: An autotranslate function suitable for use during Clone based
*             Import/Export. The function receives the name to be translated
*             in old_name.  If this is a cli form name, the function should
*             return a corresponding native part file name in new_name,
*             otherwise it should return a cli style name in new_name.
*             The return value of the function should be an error status,
*             currently recogni ed error statuses are:
*             0  - Success
*             5  - Invalid File Name
*             6  - Part name Exceeds maximum length
*/

typedef int (*UF_UGMGR_clone_auto_trans_f_t)
(
   const char[ MAX_FSPEC_BUFSIZE ], /* <I> : receives the name to be translated,
                                      which will be either an NX Manager CLI
                                      form name (indicating an export
                                      operation) or a native file system
                                      specification (indicating an import
                                      operation)
                                    */

         char[ MAX_FSPEC_BUFSIZE ] /* <O> : Returns the translated name, if
                                     old_name was an NX Manager CLI form name,
                                     this should be a native file system name,
                                     if old_name was a native file system
                                     specification, this should be a
                                     NX Manager CLI form name.
                                  */

);

/******************************************************************************
Registers an autotranslate function for use during Clone Based
Import/Export. If the value of function is NULL, the default
autotranslate function is registered.

Environment: Internal and External

See Also:UF_UGMGR_clone_auto_trans_f_t
Please refer to the   example  

History: This function was originally released in V15.0.
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_clone_auto_trans
(
   UF_UGMGR_clone_auto_trans_f_t  /* <I>
                                  Auto Translate Function
                                  */

);

/* Obsolete from v12.0: just call UF_terminate */
extern UFUNEXPORT int UF_UGMGR_terminate( void );

/**************************************************************************************
Allows setting of the autolock status for checking out of parts when modified.
This is the equivelent of the UGII_UGMGR_NOAUTOLOCK environment variable.
If the autolock status is true, a part will be automatically checked out
when it is loaded if it needs to be modified. Setting this value to false
will prevent the checkout from automatically happening.

Environment: Internal and External

See Also:   UF_UGMGR_ask_autolock_status  

History: This function was originally released in V16.0.2
**************************************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_autolock_status
(
   logical         new_value     /* <I>
                                    New value of the autolock status
                                    TRUE = part is automatically checked out on update.
                                   FALSE = part is not automatically checked out.
                                 */

);

/**************************************************************************************
Allows querying of the autolock status for checking out of parts when modified.

Environment: Internal and External

See Also:   UF_UGMGR_set_autolock_status  

History: This function was originally released in V16.0.2
**************************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_autolock_status
(
   logical  *      current_value /* <O>
                                    Current value of the autolock status
                                 */

);
/*******************************************************************************
Performs a single-level where-used operation on the given part revision.
The current configuration rule will be used.
Environment: Internal  and  External

See Also

History: This function was originally released into V18.0
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_partrev_where_used(
   UF_UGMGR_tag_t      part_revision,   /* <I>
                                           Database tag of the part_revision for
                                           which to perform a where-used.
                                        */

   int *               parent_revisions_count ,/* <O>
                                                  Number of revisions of the specified part.
                                               */

   UF_UGMGR_tag_t **   parent_revisions  /* <OF>
                                            Array of database tags of all part revisions
                                            which use the specified part_revision according to
                                            the current configuration rule.
                                            The array must be freed after use by calling UF_free().
                                         */

);

/******************************************************************************/

/* UF_UGMGR_variant_configuration_t: A structure defining and describing a
Variant Configuration. It comprises the name (in CLI format) of a Product
Assembly, the name of a Variant Rule contained in the Team Center Engineering Item Revision
corresponding to that Product Assembly, and the description field of that
Variant Rule.

Note that a Product Assembly may have more than one Variant Rule associated
with it; the Product Assembly may be paired with each of these Variant Rules
to produce several different Variant Configurations. However, a Variant Rule
may only be paired with the Product Assembly that contains it. */

struct UF_UGMGR_variant_configuration_s
{
   char product[ MAX_FSPEC_BUFSIZE ];      /* The item revision of the Product Assembly in
                                           CLI form (i.e. @DB/<ItemID>/<RevID>). */

   char variant[UF_UGMGR_FNAME_BUFSIZE]; /* The name of the saved Variant Rule that
                                           specifies this configuration. */

   char desc[UF_UGMGR_DESC_BUFSIZE]; /* The description of the saved Variant Rule. */
};
typedef struct UF_UGMGR_variant_configuration_s UF_UGMGR_variant_configuration_t;

/***********************************************************************
Returns an array of all Product Assemblies currently recognised by the
session. A Product Assembly is any Partrev whose corresponding Team Center Engineering
Item Revision contains one or more associated Variant Rules.

The Product Assemblies are returned in CLI format
(e.g. "@DB/partname/A" )

Environment : Internal  and  External

History : Originally released in V19.0
***********************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_product_assemblies
(
   int    *n_prod_assys, /* <O>  Number of product assemblies the session knows about */
   char ***products    /* <OF> Current set of product assemblies, in CLI form.
                                    Free with UF_free_string_array */

);

/***********************************************************************
Adds a Product Assembly to the list of those recognised by the current
NX Manager session.

Specify the Product Assembly in CLI format.

Environment : Internal  and  External

History : Originally released in NX 5.0 and is mandatory if Longer IDs functionality is enabled NX/Manager
***********************************************************************/

extern UFUNEXPORT int UF_UGMGR_add_product_assembly_part
(
   const char *product     /* <I>  Name of the product assembly in CLI form. */
);

/***********************************************************************
Removes a Product Assembly from the list of those recognised by the
current NX Manager session.

Specify the Product Assembly in CLI format.

Environment : Internal  and  External

History : Originally released in NX 5.0 and is mandatory if Longer IDs functionality is enabled NX/Manager
***********************************************************************/

extern UFUNEXPORT int UF_UGMGR_remove_product_assembly_part
(
   const char *product      /* <I>  Name of the product assembly in CLI form. */
);

/***********************************************************************
Searches for all Product Assemblies that contain any of the parts listed
in the "displayed parts" argument as components or components of
subassemblies. It adds these to the list of Product Assemblies that the
session knows about. Note that the Product Assemblies are not actually
returned.

If 0 is used as the first argument, the routine will search for all
Product Assemblies that contain any of the current session's current
list of displayed parts (this is likely to contain all loaded parts that
have ever been displayed parts in the session).

Environment : Internal  and  External

History : Originally released in V19.0
***********************************************************************/

extern UFUNEXPORT int UF_UGMGR_find_product_assemblies
(
   int         n_displayed_parts, /* <I>  Number of displayed parts to search from.
                                          If n_displayed_parts is 0, all current displayed parts will be searched and
                                          the displayed_parts argument ignored.*/

   const tag_t displayed_parts[] /* <I>   n_displayed_parts
                                Displayed parts to search from. */

);

/***********************************************************************
Returns the current Variant Load Options.

An array of Variant Configurations is returned - each of these contains
a Product Assembly and a Variant Rule.

A parallel array of logicals indicates whether each of these Variant
Configurations is active.

When an assembly is loaded into the session, all these active Variant
Configurations will be applied to it.

Environment : Internal  and  External

History : Originally released in V19.0
***********************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_variant_configurations_for_load
(
   int                              *n_variants, /* <O>   Number of variant configurations available. */
   UF_UGMGR_variant_configuration_t **variants,   /* <OF>  n_variants
                                                       Available variant configurations. Free with UF_free.*/

   logical                          **selected    /* <OF>  n_variants
                                                       Parallel array of logicals: true if corresponding variant
                                                               configuration is to be selected for load, false otherwise.
                                                               Free with UF_free. */

);

/***********************************************************************
This routine sets the current Variant Load Options.

You must provide an array of Variant Configurations (preceded by a
separate argument giving its length). Each Variant Configuration
contains a Product Assembly and a Variant Rule.

You must also provide a parallel array of logicals indicating whether
each of these Variant Configurations is selected for load.

It is generally envisaged that one would call
UF_UGMGR_ask_variant_configurations_for_load
then change the array "selected" slightly and then call
UF_UGMGR_set_variant_configurations_for_load
to apply the changes.

Environment : Internal  and  External

History : Originally released in V19.0
***********************************************************************/


extern UFUNEXPORT int UF_UGMGR_set_variant_configurations_for_load
(
   int                              n_variants, /* <I>
                                                Number of variant configurations available. */

   const UF_UGMGR_variant_configuration_t variants[],  /* <I>
                                                      Available variant configurations. */


   logical                          selected[]   /* <I>
                                                Parallel array of logicals: true if corresponding variant
                                                            configuration is selected for load, false otherwise. */

);

/***********************************************************************
This routine returns the current Variant Display Options for a
particular displayed part.

The first argument of the function is the displayed part for which you
want the Variant Display Options.

An array of Variant Configurations is returned - each of these contains
a Product Assembly and a Variant Rule.

A parallel array of logicals indicates whether each of these Variant
Configurations is active.

The occurrence tree of this displayed part is configured by the active
Variant Configurations - so some part occurrences may be suppressed.
Note that this set of Variant Display Options (like the part occurrence
tree) is specific to a particular displayed part - so a Variant
Configuration may be active for one displayed part and not for another,
and an instance whose part occurrence is suppressed in this displayed
part may not be suppressed in another displayed part.

Environment : Internal  and  External

History : Originally released in V19.0
***********************************************************************/


extern UFUNEXPORT int UF_UGMGR_ask_variant_configurations_for_display
(
   tag_t                            available_displayed_part, /* <I>  Part that returned information is about. */
   int                              *n_variants, /* <O>   Number of variant configurations available. */
   UF_UGMGR_variant_configuration_t **variants,  /* <OF>
                                                       Available variant configurations. Free with UF_free. */

   logical                          **selected   /* <OF>
                                                       Parallel array of logicals: true if corresponding variant
                                                       configuration is to be selected for this part, false otherwise.
                                                       Free with UF_free. */

);

/***********************************************************************
This routine sets the current Variant Display Options for a particular
displayed part.

The first argument of the function is the displayed part for which you
want to set the Variant Display Options.

You must supply an array of Variant Configurations - each of these
contains a Product Assembly and a Variant Rule.

You must also supply a parallel array of logicals indicating whether
each of these Variant Configurations is active for this displayed part.

The occurrence tree of this displayed part is configured by the active
Variant Configurations - so some part occurrences may be suppressed.
Note that this set of Variant Display Options (like the part occurrence
tree) is specific to a particular displayed part - so a Variant
Configuration may be active for one displayed part and not for another,
and an instance whose part occurrence is suppressed in this displayed
part may not be suppressed in another displayed part.

It is generally envisaged that one would call
UF_UGMGR_ask_variant_configurations_for_display
then change the array "selected" slightly and then call
UF_UGMGR_set_variant_configurations_for_display
to apply the changes.

Environment : Internal  and  External

History : Originally released in V19.0
***********************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_variant_configurations_for_display
(
   tag_t                            available_displayed_part, /* <I>
                                                              Part for which to set variant configurations.*/

   int                              n_variants, /* <I>
                                                Number of variant configurations available. */

   const UF_UGMGR_variant_configuration_t *variants,  /* <I>
                                                      Available variant configurations.*/

   logical                          selected[]   /* <I>
                                                Parallel array of logicals: true if corresponding variant
                                                configuration is selected for this part, false otherwise.*/

);

/*******************************************************************************
Returns the total number of ID display rules available to the user and a list
of the names of all these ID display rules.

Environment: Internal and External

History:  Originally released in NX 2.0.1
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_list_id_display_rules(
   int    *count,              /* <O> Number of ID display rules. */
   char ***id_display_rules    /* <OF> Array of the names of the ID display
                                   rules available to the current user.
                                   The array must be freed after use by
                                   calling UF_free_string_array(). */

);


/*******************************************************************************
Returns your current ID display rule. If none are defined for the current
user or the last chosen ID display rule no longer exists in the PDM, then
"$PDM default" is returned.

Environment: Internal and External

History:  Originally released in NX 2.0.1
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_id_display_rule(
   char   **id_display_rule    /* <OF> Your current ID display rule.  String
                                 must be freed after use with UF_free(). */

);


/*******************************************************************************
Sets the current ID display rule to be the given rule. The rule specified
must be valid. A list of valid ID display rules for the current user may
be obtained by calling the Open API UF_UGMGR_list_id_display_rules.

Environment: Internal and External

History:  Originally released in NX 2.0.1
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_set_id_display_rule(
   const char *id_display_rule   /* <I> ID display rule. */
);

/*******************************************************************************
This routine returns an array of names of all the contexts available for the
given part type in the TCEng database. part_type cannot be NULL or Empty String

Environment: Internal and External

History:  Originally released in NX 2.0.1
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_list_contexts (
   const char *part_type,        /* <I> Type of part. */
   int        *count,            /* <O> Number of contexts in the database. */
   char     ***contexts          /* <OF> Array of names of all the contexts.
                                  The array must be freed after use with
                                  UF_free(). */

);


/*******************************************************************************
This routine returns an array of names of all the ID types for a given context
in the TCEng database.  If context is a NULL string, the list returned covers
all available id_types. part_type cannot be NULL or empty string

Environment: Internal and External

History:  Originally released in NX 2.0.1
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_list_id_types (
   const char  *part_type,    /* <I> Type of part. */
   const char  *context,      /* <I> Context for which the list of id_types
                                  is being requested.  May be NULL. */

   int         *count,        /* <O> Number of ID types for this context. */
   char      ***id_types      /* <OF> Array of the names of the ID types
                                  which are valid for the given context.
                                  The array must be freed after use with
                                  UF_free(). */

);

/*******************************************************************************
This routine generates a new alternate part number by calling a TCEng user exit.
Depending on the implemented user exit, the name returned may be dependent on
part number, part type, context or ID type.  A logical is returned alongside
the new alternate item ID or multifield key and alternate revision ID names. This logical
indicates whether the caller is allowed to change the suggested alternate item
and revision IDs after they have been generated without calling this function.
The behavior of the default user exit is to return true at all times.

For the output alt_item_id:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

Environment: Internal and External

History:  Originally released in NX 2.0.1
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_assign_alternate_part_id (
   const tag_t  part_tag,      /* <I> Tag of part to assign alternate ID. */
   const char  *context,       /* <I> Context for which an alternate number
                                  is being requested. */

   const char  *id_type,       /* <I> ID type of part for which number is
                                  being requested.  May be NULL. */

   char       **alt_item_id,   /* <OF> Alternate Item ID.  The string must
                                  freed after use with UF_free(). */

   char       **alt_rev_id,    /* <OF> Alternate Revision ID.  The string must
                                  freed after use with UF_free(). */

   logical     *modifiable        /* <O> Boolean; is the alternate ID allowed
                                  to be modified? */

);


/*******************************************************************************
Validates the alternate ID selected for a new alternate of the current part.
Both the alternate item ID or multifield key and alternate revision ID names are validated. This
function may reject the supplied identifier, accept it or amend it.  The action
is reflected in the value of status.  This function calls a TCEng user exit
function to perform the validation.  The user exit defines what constitutes
valid alternate item and revision names for an alternate ID and may depend on
the part number, part type, context and ID type.

The behavior of the default stub supplied with TCEng as part of the user exit
library is to always returns a status of USER_valid_name, with the output
arguments modified_item_id and modified_rev_id set to empty strings.  In effect,
the default behaviour represents unconditional acceptance of the user input
alternate item and revision names.

For the input alt_item_id and output modified_item_id:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

Environment: Internal and External

History:  Originally released in NX 2.0.1
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_validate_alternate_part_id (
   const tag_t  part_tag,            /* <I> Tag of part to assign the
                                         alternate ID to. */

   const char  *alt_item_id,         /* <I> Alternate Item ID.  May be
                                         NULL. */

   const char  *alt_rev_id,          /* <I> Alternate Revision ID.  May be
                                         NULL. */

   const char  *context,             /* <I> Context for which alternate
                                         name is being validated.  May be
                                         NULL. */

   const char  *id_type,             /* <I> ID type for which alternate
                                         name is being validated.  May be
                                         NULL. */

   char       **modified_item_id,    /* <OF> Modified Alternate Item ID.
                                         Will be an empty string if no
                                         amendment.  The string must be
                                         freed after use with UF_free. */

   char       **modified_rev_id,     /* <OF> Modified Alternate Revision
                                         ID.  Will be an empty string if no
                                         amendment.  The string must be
                                         freed after use with UF_free. */

   UF_UGMGR_alt_id_status_t *status,  /* <O> Enum code indicating:
                                         UF_UGMGR_alt_id_valid - accept
                                         UF_UGMGR_alt_id_invalid - reject
                                         UF_UGMGR_alt_id_modified - input
                                         modified. */

   char       **reason                /* <OF> Reason.  The string must be
                                         freed after use with UF_free. */

);


/*******************************************************************************
Attaches an alternate ID to the given part.  The alternate is defined given by
the input parameters context, id_type, alt_item_id, alt_rev_id, alt_name and
alt_desc and attached to the part with tag part_tag.

For the input alt_item_id:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

Environment: Internal and External

History:  Originally released in NX 2.0.1
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_attach_alternate (
   const tag_t    part_tag,      /* <I> Tag of part to attach alternate to. */
   const char    *context,       /* <I> Context of the alternate to attach. */
   const char    *id_type,       /* <I> ID type of the alternate to attach. */
   const char    *alt_item_id,   /* <I> Alternate Item ID of the alternate to
                                        attach. */

   const char    *alt_rev_id,    /* <I> Alternate Revision ID of alternate to
                                        attach. */

   const char    *alt_name,      /* <I> Alternate Name of alternate to
                                        attach. May be NULL. */

   const char    *alt_desc,      /* <I> Alternate Description of alternate to
                                        attach. May be NULL. */

   const logical  is_default     /* <I> True if this alternate ID should
                                        become the default ID, false otherwise.
                                  */

);


/*******************************************************************************
Returns a pointer to a registered program or NULL if none is registered.

Environment: Internal and External

History:  Originally released in NX 2.0.1
*****************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_new_alternate_part_no (
   UF_UGMGR_new_alternate_part_no_fn_t *func   /* <O> Pointer to registered
                                                   function to invoke. */

);


/*******************************************************************************
Stores a pointer for a user supplied registered callback.  May be NULL
to un-register a program.

Environment: Internal and External

History:  Originally released in NX 2.0.1
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_reg_new_alternate_part_no (
   UF_UGMGR_new_alternate_part_no_fn_t func   /* <I> Pointer to the user
                                                 supplied registered Open API
                                                 callback. */

);


/**********************************************************************

This function returns tags of parts or part revisions contained in the
given folder.  You must specify the database tag of a folder that
already exists.

Environment: Internal  and  External

History: Released in NX3.0

**********************************************************************/

extern UFUNEXPORT int UF_UGMGR_list_parts_in_folder(
   UF_UGMGR_tag_t folder , /* <I> Database tag of the folder whose
                                  part you wish to be listed. */

   int * count , /* <O> The number of parts in the specified folder.*/
   UF_UGMGR_tag_t ** parts  /* <OF> An array of database tags of type
                                     UF_UGMGR_type_part or
                                     UF_UGMGR_type_part_revision in
                                     the specified folder.
                                     This array must be freed after
                                     use by calling UF_free(). */
);

/******************************************************************************
Finds the tag of a part in the database corresponding to the specified
part revision tag. If the function is successful, the output
argument contains the database tag of the part. If the function is
unsuccessful, then the output argument is UF_UGMGR_null_tag.

Environment: Internal  and  External

History: Released in NX3.0
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_partrev_part_tag(
   UF_UGMGR_tag_t   database_part_rev_tag ,   /* <I>
                                              Database tag of the part revision
                                              */

   UF_UGMGR_tag_t * database_part_tag         /* <O>
                                              Database tag of the part corresponding to
                                              the specified part revision tag.
                                              */

);

/*******************************************************************************/

/******************************************************************************
Registers the user's method  that is used to generate the non-master dataset
naming information during "Save As New Item" or "Save As New Item Revision"
operation on the master part.

If a NULL is used then the program will be un-registered.
Memory for the return array elements in the structure UF_UGMGR_saveas_dataset_info_s,
namely dataset_name_list, copy_state, name_locked, validation_required, original_owner,  
and each character array in the dataset_name_list array  must be allocated using UF_allocate_memory
in this method implementation.

Environment: Internal and External

History:  Originally released in NX 2.0.5
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_reg_saveas_dataset_info
(
   UF_UGMGR_saveas_dataset_info_fn_t saveas_dataset_info_fn
                                     /* <I>
                                     Pointer to the user supplied
                                     registered Open C API program
                                     */

);

/*******************************************************************************
Returns the user's method that was registered using UF_UGMGR_reg_saveas_dataset_info
that is used to generate the non-master dataset naming information during "Save As New Item"
or "Save As New Item Revision" operation on the master part.
 
Environment: Internal and External

History:  Originally released in NX 2.0.5
*******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_saveas_dataset_info
(
   UF_UGMGR_saveas_dataset_info_fn_t *func
                                     /* <O>
                                     Pointer to the user supplied
                                     registered Open C API program
                                     */

);


/*******************************************************************
Returns the pre-allocated part and part rev handle values for the member.
The API will return NULL values for the handles if the member id and the
revision id do not match the stored values.

For the input member_id:
In case of Default Domain: it is Team Center Engineering item ID.
In case of non-Default Domain: it is the multifield key.
       e.g.   ,=item_id=001, object_type=Document
              ,=item_id=001, object_type=SupplierPart, supplier_code=x

Environment: Internal and External

History: Originally released in NX 3.0.2
*******************************************************************/

extern UFUNEXPORT int UF_UGMGR_ask_family_member_handles(
   tag_t          family_tag,             /* <I> family tag of the part family
                                              template */

   const char*    member_id,              /* <I> member id, i.e. DB_PART_NO
                                              value of the family member */

   const char*    member_rev_id,          /* <I> member rev id, DB_PART_REV
                                              value of the family member */

   char**   member_part_handle,     /* <OF> part handle of the family member
                                     This must be freed by calling UF_free() */

   char**   member_partrev_handle   /* <OF> part rev handle of the family member
                                     This must be freed by calling UF_free() */

);

/*******************************************************************


Not a published API as of now.

Environment: Internal

History: Originally released in NX4.0.1
*******************************************************************/


extern UFUNEXPORT int UF_UGMGR_refresh_assy_pdi_date(
   tag_t          part_tag,             /* <I> */
   logical        traverse              /* <I> */
);


/*****************************************************************************
Extended function for 'UF_ASSEM_create_component_part' with additional parameter
  for Part Type.
Create a new part with the given part type, moves selected objects to it, then
  adds an instance of it to the parent part.
Any other transferrable objects upon which  the given objects depend are also moved into the component.

Environment: Internal  and  External
History: Originally released in NX 3.0.4
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_create_component_part(
   tag_t parent_part,          /* <I> Tag of parent part */
   const char * new_part_name, /* <I> Name of new component part */
   const char * refset_name,   /* <I> Name of reference set */
   const char * instance_name, /* <I> Name of instance to add to parent part */
   int units,                  /* <I>  1    = MM,
                                       2    = Inches  */

   int layer,                  /* <I>  -1   = original
                                        0   = use work layer
                                      1-255 = use specified layer  */

   double origin[3] ,          /* <I>  Position in parent part where the instance is to be created. */
   double csys_matrix[6],      /* <I>  Orientation of the instance */
   int n_objects,              /* <I>  Number of objects in the "objects" array. */
   tag_t * objects,            /* <I> Pointer to an array of tags of objects that should be
                                       moved to the new component part.  */

   const char* part_type,      /* <I> Part type for the new component Part */
   tag_t * instance            /* <O> Tag of instance */
);

/*******************************************************************
To save the given assembly part as Precise Structure in the database
It will attempt to save the assembly and any of its sub-assembly structure
that are out-of-sync with its corresponding Precise BVR in the database.

Environment: Internal and External

History: Originally released in NX 5.0
*******************************************************************/


extern UFUNEXPORT int UF_UGMGR_save_precise_assembly
(
   tag_t                 work_part_tag,           /* <I>  Part tag for the assembly that has to be saved */
   logical               traverse_children        /* <I>  true if the sub-assemblies and nested
                                                       sub-assemblies are considered for Save operation */

);

/*******************************************************************
Checks if string is valid against the current Teamcenter Target Encoding.
The string will be considered valid if - when converted to the Target Encoding -
its length does not exceed the given limit and all of its characters and can be represented
in the Target encoding.

Environment: Internal and External

History: Originally released in NX 9.0
*******************************************************************/

extern UFUNEXPORT int UF_UGMGR_validate_string (
   const char*  inputString,    /* <I> */
   unsigned int lengthLimit,    /* <I> */
   logical*        hasInvalidCharacters  /* <O> */
);

/*******************************************************************
This is the bulk replacement for all UF functions that deal with NX part file names
and TC Item/ItemRev/Dataset,such as UF_UGMGR_encode_part_filename, UF_UGMGR_decode_part_file_name,
UF_UGMGR_ask_dependent_files, UF_UGMGR_ask_part_tag, UF_UGMGR_list_part_revisions,
UF_UGMGR_ask_part_number, UF_UGMGR_ask_part_revision_id, UF_UGMGR_list_part_rev_files, etc.

Environment: Internal and External

History: Originally released in NX 10.0
*******************************************************************/

extern UFUNEXPORT int UF_UGMGR_resolve_part_file_infos (
   unsigned int                        partFileCount,         /* <I> Number of UF_UGMGR_part_file_info_t's to be processeed */
   const UF_UGMGR_part_file_info_t*    partFileInput,         /* <I> UF_UGMGR_part_file_info_t's to be resolved*/
   UF_UGMGR_part_file_object_t***      partFileObject         /* <OF>
                                                                     An array of pointers to UF_UGMGR_part_file_object_t. Each UF_UGMGR_part_file_object_s object
                                                                     returned corresponds to a UF_UGMGR_part_file_info_s(NX PartFile) that was resolved
                                                                     This array must be freed after use using UF_free()
                                                               */

);

/*******************************************************************************
This routine returns an array of creation parameters which are needed to
create a part of the given part type in Teamcenter. Each parameters is
represented by a UF_UGMGR_ATTR_info_t struct. The parameter can be
a create descriptor, or a key field, or both. The part_type cannot be
NULL or Empty String.

Environment: Internal and External

History:  Originally released in NX 10.0
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_get_creation_parameters(
   const char              *part_type,   /* <I> Type of part. */
   int                     *num_info,    /* <O> Number of creation parameters. */
   UF_UGMGR_ATTR_info_t    **info        /* <OF> Array of the creation parameters.
                                            The array must be freed after use with UF_free(). */

);

/*******************************************************************************
This routine returns a base file name.

Environment: Internal and External

History:  Originally released in NX 10.0
******************************************************************************/

extern UFUNEXPORT int UF_UGMGR_generate_base_file_name (
   const char *partSpec,    /* <I> part specification */
   char **baseFileName       /* <O> Base file name*/
);



#undef EXPORTLIBRARY