Fixed Problem Reports

NX 10

PR

Description

112739

In NX 8.0.1 of UG, Updating component entities consecutively (changing part name and reference set) results in rm5061 error. 001 The assembly part, 112739a, contains a reference set SS-S2B1-BASIC that contains over 30000 members. When the first component, 112739b, is updated, it brings in more entities than the original component had because the reference set specified in the update is bigger. When this larger component is added to reference set SS-S2B1-BASIC in the assembly, the size of that reference set exceeds 32767, which is the maximum. Unfortunately, since a reference set of that size is not really useful, the code does not check for the maximum, and the integer count of members actually rolls over into a negative number. This will cause subsequent 010 operations on that reference set to fail. In this case the "subsequent operation" was the update of 112739c. This problem will go away in V10 as reference sets will be able to contain close to 4 billion members. To get around the problem for now, just delete the reference set SS-S2B1-BASIC and any other reference sets that may be that large. It seems unlikely that they would be useful, since I am not sure what sort of assembly part you would expect to merge sub assemblies of this size. i.e. 2 of them would overflow the entity count. If there are GRIP or User Function programs that automatically build a standard set of reference sets, you may want to have them check the part size first and not build a reference set containing everything if the entity count is close to 50% of capacity. This problem will not exist in NX10.

134991

The references to laminated material properties of QUAD/4 elements in the GFEMFEA appendix of the GFEMPLUS manual have been removed. GFEMFEA does not support laminated material properties. This information was mistakenly included from the PATRAN PFEA manuals. The GFEMPLUS manual includes these changes in the V10 manual.

136003

Fixed in phase 12 by Kevin Le

137446

Origin statement in operations in metric parts no longer generate errors. When an ORIGIN & FROM are both active the ORIGIN is not output in its specified location in the post command sequence. Works as designed! When FROM is active, ORIGIN always proceeds the FROM regardless of post command order. Documentation will be clarified.

138255

In Version 9.2 of UGTODMIS, the user will be able to enter more than 99 DATSET commands in a single DMIS program without causing asterisks to be written to the file.

138516

The cavity milling processor will generate arcs to cut a cavity. These arcs are not generated by the arc fit option. A potential enhancement would be linear interpolation of arcs; the arcfit option does not change arcs into linear gotos. Once an arc is an arc, it stays an arc.

138881

GPM no longer outputs Adjust codes if not programmed.

140184

This problem has been fixed in the "supplemental" V10.0 GENMOD release that will shipped along with the official V10 cdrom release. This has been verified to work in the V10.1 release.

142487

In V9 of UG, after performing a unite on two named groups, one group remains empty and is not deleted. This is being fixed in v10 with the new delete algorithm and a change in the link type for groups. Hence, when all members of a group are deleted, the group itself will be deleted.

143592

Fixed in V10.

144290

The declaration for MAT(12) has been changed to NUMBER in the V10.0 Grip Programming manual.

145722

The RM11 error problem retrieving a part file into V9.1 is not fixed in V10.

146203

Fixed in V10 Phase 12.

147088

The built-in constant expressions have been deleted from the V10 manual.

147193

Fixed in V10.

148160

The problem with GFEMFEA BAR/2/7 elements has been corrected in V10.1. BAR/2/7 elements format without problems and can be used in GFEMFEA analysis. Verified by L. Cull NTS

148165

This will be corrected on the next release of the document, which should be the V10 release.

148788

Part surfaces converted from a blended solid face now machine correctly with Zigzag surface routine.

152172

The problem with uf5910 giving bad values has been fixed for V10.

152200

The problem of the incorrect cylindrical face direction vector is fixed in V10 ph12.

152283

This problem has been fixed in UGII V10 phase 11.

152365

Cavity milling now machines trimmed surfaces.

152481

A collection of associated problems with ACS are fixed in V10.0 of the Unigraphics but await full testing. These problems consist of the ACS_MAS node dying when acsexec is run with more than 32 nodes logged into UG. Receiving incomprehensible characters in the last field of the ACS log fil and receiving no node names in some of the entries. The ACS log file ent were also wrapping around the screen when displayed to a window. The 'sho current usage' option of acsexec was also displaying incomprehensible characters.

152779

The problem where dimensioning to the endpoints of arcs using the point sub-function menu and the extension line origin changes when the dimension is updated, has been fixed in UG V10.

153018

All parametric spline surfaces are mapped to b-surfaces in v10. The b-surface is more accurate than the parametric spline surface and the points are on the surface within a tolerance of less than .000000001. So the problem has been corrected in v10.

153179

The problem in UGConcepts where angled lines required extra constraints, has been fixed in UG V10.

153223

The install script for Worldview (UG on-line documentation) has been upgra for UG v10.x. The install script will no longer abort if you have more than one CDROM mounted during the install.

153454

The problem where a RM 33 error was encountered when attempting to edit a dimension has been fixed in UG V10.

153769

Documentation of null part procedures has been enhanced in the V10.0 User Guide, Appendix H.

153992

This problem was verified as fixed in V10.1. Topology Forces and Moments are know distributed to the nodes correctly. Verified by L. Cull.

154454

The problem of a 3-D pattern not mirroring through a plane correctly is fixed in V10 ph 13B. Todd Stauder.

154931

For V10 of Unigraphics, the spaceball will start up when UG is started from UGMENU using the vsbmod driver. The problem with the spaceball not starting unless X11 or vue was previously running has been resolved. The spaceball will correctly start in V10 as long as UG is started from UGMENU in either the console or a window.

154954

The problem with DISPLAY CONTROL, Surface/Solid Display, Hidden Edge, not working with patterns has been addressed and fixed in V10 phase 13 of Unigraphics.

155011

This PR has been fixed in V10 Phase 11.

155084

In v9.1 eds_reset did not find multiple copies of the plot despoolers that were running. This would cause PQMGR to give a license limit exceeded when trying to restart multiple plot despoolers. The v10 despoole now have different names, and eds_reset now finds all of the plotters run.

155585

The problem with some of the trimmed surfaces converting as only on the ed the surface will not grid and it only displays one sem, has been fixed in so that the surface is now inside the curve instead of on the curve. The surfaces grid and shade correctly.

155690

The problem with leaders being attached to the wrong area of a GD&T symbol after relocating the origin has been fixed in UG V10.

155755

Fixed by wayne sanders in v10 phase 11. I verified using my customer's acs sheet. It works with v10/phase 5/5 and v10/phase12c.

158635

The problem has been found and will be fixed in v10.

159179

Documentation for the IGES error 728 has been included in draft for the next release.

159570

In the V10 Grip manual, the EDA &DKRED has been fixed.

159640

The problem of Info returning the wrong information of angle between to parallel lines has been addressed and fixed in the next release of UG.

159753

Editing of dimensions text and origin has changed in V10.0. I was unable to reproduce the problem in V10. I believe this problem has been corrected. T.Olsen 29 April 93.

159828

SB_DISPLAY_ADDR is no longer used, and the check for it has been taken out of the ugii script. Thus this customer will no longer have to modify the files.

159954

The problem where the silhouette of a cylinder could not be used as the horizontal/vertical attachment line of a GD&T symbol has been fixed in Unigraphics V10.0.

159988

Fixed in V10.

160009

Fixed ufx013. vaccaro 3 June 1993.

161463

In the IGES preprocessor, when converting patterns to subfigures, the enti in the sub-figure are now being marked as dependent.

161690

Acsexec/license exceed 10 did not show user usage.

162263

Finl In v100 the subtypes will match the documentation in appendix a for c nics.

162464

The problem with a view dependent surface edge curve causing the IGES translator to hang when view dependent is turned off in preprocessing option has been fixed in v10.

163134

This problem of fixed axis surface contouring gouging has been fixed in V10.

163135

In the V10.0 Grip manual, the arguments for &ATTVL have been corrected so that the data type is now listed last in the argument line.

163224

This PR has been fixed in 12f for V10.

163331

The V10.0 Grip manual has been changed as requested. On page 11-64, references to the entity list table in the appendix have been removed and the old V9.0 entity list table has been restored for the MASK command.

163943

The problem whereby the intersection of two sheet solids produces an RM22 error has been fixed in the next release of UG.

164278

The allowable entity type table for MASK has been corrected for the V10 Grip manual so that it matches the correct table used in V9.

164559

The new ugii script in v10 will correctly work if the spaceball is installed.

165855

Problem receiving "4 invalid pointer file in CSDATA" cross-sectioning multiple surfaces has been addressed and fixed in v10 phase 13 of Unigraphics.

167241

The problem of 1 tag dead or invalid in delent has been addressed and fixed in the next phase og UG.

167713

The problem with the IGES preprocessor hanging on a dimension when view dependent is turned off in preprocessing options has been fixed in v10.

174416

Saving a CSYS that is coincident with the cs no longer has the effect of making the CSYS permanent, i.e. it can be moved deleted, etc.

184560

This is CRR 184560 text: The Grip Intsec command for version 9.1.n and prior versions, required the specification of a tolerance value, if anything other than .001 was desired ( the default tolerance). The default tolerance was inappropriate for metric parts. This problem has been fixed in version 10.0 with the Global Approximation Tolerance Project. This project made available the PREFERENCES - MODELING - DISTANCE TOLERANCE to the user. This value can be set in Customer Defaults. It is also set based on part units. The GRIP INTSEC command will default to this value when no tolerance is specified. Doug Birch, NTS.

1127621

Siemens PLM believes that the problem you reported where Thread from Extract does not update will be resolved by code changes made to the release of our product NX version 10. The problem where a copied thread feature on Extract body did not update after source got updated, when delete propagation is turned OFF, has been fixed in NX 10 Phase 20.

1127899

Siemens PLM believes that the problem you reported where there is an Internal Error when performing a Routing Reuse Search Children operation will be resolved by code changes made to the release of our product NX 10.

1128228

Siemens PLM believes that the problem you reported where will be resolved by code changes made to the release of our product NX version 10. Several changes were made to edge-face stitch in NX 10. On user supplied models ... 100 bodies reported in NX 9.0.3: 20 sec NX 10: 6 sec 200 bodies reported in NX 9.0.3: 2 min NX 10: 14 sec 300 bodies reported in NX 9.0.3: 6 min NX 10: 30 sec 400 bodies reported in NX 9.0.3: 13 min NX 10: 58 sec all bodies selected and search 0.2 and snap 0.1 was used for the test above.

1128256

Siemens PLM believes that the problem you reported where saving a part with long string attribute containing XML tag leads to a bad performance will be resolved by code changes made to the release of our product NX 10. However, such attributes are not supported by the legacy User Function and the NX UI cannot hold strings of that length.

1128285

Siemens PLM believes that the problem you reported where Transform path does not work as expected with NX 9 spline paths will be resolved by code changes made to the release of our product NX 10. The fix will also be included in the next possible maintenance packs for NX 9.0.2 and NX 9.0.3.

1128436

Siemens PLM believes that the problem you reported where NX Routing Heal Path Method: YC ZC XC does not work properly will be resolved by code changes made to the release of our product NX 10.

1128442

The issue of 'Drawing not properly Exported' is fixed NX 10. A fix has been available also in NX 9.0.3 MP3.

1128556

Siemens PLM believes that the problem you reported where unable to edit deform feature will be resolved by code changes made to the release of our product NX version 10. This problem where internal error occurs upon selecting flex instantiation feature in part navigator is fixed in NX 10. From NX 10 onwards the part can be opened and corrupt feature can be deleted and recreated successfully. The customer's parts are repaired in NX 7.5.5 (repaired_parts.7z). please download here: http://download.industrysoftware.automation.siemens.com/special.php/returned/pr 1128556_repaired_parts-clean.7z

1128576

Siemens PLM believes that the problem where the Limit/Fit tolerance specification is not available on the scene dialog for ASME/inch units is fixed in NX 10. This version is planned to be available for customer download from 23-Dec-2014.

1128799

Siemens PLM believes that the problem you reported where Blend Miter causes Export to Trumpf Geo to fail will be resolved by code changes made to the release of our product NX 10.

Note :To get this fix, user has to recreate Closed Corner features with Blend Miter in NX 10. It can be seen that Flat Pattern doesn't create extra lines and Export Flat Pattern to Trumpf Geo works fine.

1128814

Siemens PLM believes that the problem you reported where Holetable not working as expected will be resolved by code changes made to the release of our product NX 10.

Work Around:

1. User has set option to display "Two-Sided Holes". When this setting is ON Hole Table will display both sided holes. i.e viewing direction and back side of viewing direction. So all label that user think are at wrong position are actually pointing to holes which are back side viewing direction. If user change the setting to "One-Sided Hole" then all labels pointing to back side hole will go away.

2. If user change the setting to "One-Sided Hole" then it is observe that few holes are not identified. This problem is fix in NX 10.

1129051

Siemens PLM believes that the problem you reported where Sketcher update failed with memory access violation will be resolved by code changes made to the release of our product NX version 10. The problem where user got an error for memory access violation while updating Extract Body feature after editing sketch, has been fixed in NX 10.

1129384

Update status difference between NX 9 and NX 10.

1129440

Siemens PLM believes that the problem you reported where Hole Table did not work correct will be resolved by code changes made to the release of our product NX version 10.

There were 2 issues mentioned in this PR for NX 9.0.x release.

1. Issue#1 is where some holes are missing in the hole table.

2. Issue#2 is where some partial non-hole features are getting identified as 'through holes'.\240 Issue#1 is fixed in NX 10.0.0. Issue#2 is having work around. User need to go to settings -> Hole Filters -> Include Partial Angle = OFF. \240 This WA can be used by as sort term solution. Development team would like to investigate this issue further for the appropriate resolution. PR#7222241 is filed to track this issue#2.

1129511

Siemens PLM believes that the problem you reported where Wrong Major Diameter is inherited from customized thd_metric.dat file will be resolved by code changes made to the release of our product NX 10.

1129646

Siemens PLM believes that the problem you reported where Online-Doc does not say something about Turning Feeds&Speeds inside Machining Data will be resolved by code changes made to the release of our product UGDOC NX 10.

1129894

Siemens PLM believes that the problem you reported where Insert Text From File not working for Note command in managed mode of NX 9.0.3 will be resolved by code changes made to the release of our product NX 10.

1526918

Siemens PLM believes that the problem you reported where Feature Playback fails in NX 3 and NX 4 will be resolved by code changes made to the release of our product NX 10.

1652936

Siemens PLM believes that the problem you reported where Feature Playback is successful in NX 2 but fails in NX 5 at Draft Body(25) raising the error "Invalid References. Try Isocline method" will be resolved by code changes made to the upcoming release of our software NX 10.

1673996

Siemens PLM believes that the problem you reported where it is not possible to delete routing ports in this part file will be resolved by code changes made to the upcoming release of our software NX 10.

1695644

Siemens PLM believes that the problem you reported where STEP files do not open in NX 6.0.1 will be resolved by code changes made to the upcoming release of our software NX 10.

1700085

The problem where Analysis->Minimum Radius would sometimes not report a radius in a concave face and sometimes report a radius on a convex face has been fixed in NX 10.

1701242

Siemens PLM believes that the problem you reported where a Step file fails to import into NX, will be resolved by code changes made to the upcoming release of our software NX 10.

1715959

Siemens PLM believes that the problem you reported where with 2D Exchange, a full bolt circle display is not correct will be resolved by code changes made to the upcoming release of our software NX 10.

1726548

Siemens PLM believes that the problem you reported where a Fatal Error is reported when translating to dxf will be resolved by code changes made to the upcoming release of our software NX 10.

1729352

Siemens PLM believes that the problem you reported where the Routing Bill Of Materials overrode previously defined Edit Levels on an existing Parts List, will be resolved by code changes made to the upcoming release of our software NX 10.

1735707

Siemens PLM believes that the problem you reported where importing a DWG file crashes NX and the DWG translator will be resolved by code changes made to the upcoming release of our software NX 10.

1740842

The problem where the Assembly Structure was duplicated when a file contained Arrangements has been investigated and the following has been found. This PR has been reviewed by development. Due to the low priority of the problem and the length of time the current behavior has been in the system we do not intend to fix this PR. If the problem is still impacting your day to day operation as you use the NX product, please contact GTAC to have the PR reopened. A note was added to the Help content for Arrangements in drawings that explains that arrangement data is added to the drawing file when arrangements are used in a drawing.

1745588

Siemens PLM believes that the problem you reported where double dimensions do not translate to dxf correctly will be resolved by code changes made to the upcoming release of our software NX 10.

1753286

Siemens PLM believes that the problem you reported where UGTO2D Centerlines of a Full Bolt Circle are extended to the circle center will be resolved by code changes made to the upcoming release of our software NX 10.

1768204

"Attempt to write to freed object" if closing a part.

1768293

Siemens PLM believes that the problem you reported where moving multiple components incorrectly displays position icons in the ANT will be resolved by code changes made to the release of our software NX 10.

1781022

Siemens PLM believes that the problem you reported where updating the value for DB_PART_NAME in the Part Family Spreadsheet did not update the values in Teamcenter, nor the value in existing members, will be resolved by code changes made to the upcoming release of our software NX 10.

1787572

Siemens PLM believes that the problem you reported where a Sketch fails when a sketch dimension is edited with Expression Editor, will be resolved by code changes made to the upcoming release of our software NX 10.

1790291

Siemens PLM believes that the problem you reported where the 2D Exchange translator showed lines that were not shown in NX will be resolved by code changes made to the upcoming release of our software NX 10.

1796920

Siemens PLM believes that the problem you reported where it is not possible to lock engagement and rotation of one port, will be resolved by code changes made to the upcoming release of our software NX 10.

1807715

Siemens PLM believes that the problem you reported where information on internationalization on UNIX and MAC was incomplete or missing will be resolved by code changes made to the release of our product NX 10.

1814328

Siemens PLM believes that the problem you reported where Update to End or automatic feature replay hides Alerts in Boolean operation will be resolved by code changes made to the upcoming release of our software NX 8.

1819469

IPE is not update when using part family criteria.

1828004

Siemens PLM believes that the problem you reported where section inertia calculation results are wrong for small circles will be resolved by code changes made to the upcoming release of our software NX 10.

1832382

Siemens PLM believes that the problem you reported where updating a Section View reported: "Error: Modeler error: inconsistent arguments, or internal error", will be resolved by code changes made to the release of our product NX 10.

1840213

Siemens PLM believes that the problem you reported where some menu items are not displayed correctly in French will be resolved by code changes made to the release of our product NX 10.

1840921

Siemens PLM believes that the problem you reported where editing a path to add a point creates an explicit override in the assembly will be resolved by code changes made to the upcoming release of our software NX 10.

1841754

Siemens PLM believes that the problem you reported where Electrical Replace Part Connector or Support will delete WAVE link of port will be resolved by code changes made to the upcoming release of our software NX 10.

1842271

Siemens PLM believes that the problem you reported where adding Routing stock was not working in Teamcenter will be resolved by code changes made to the upcoming release of our software NX 10.

1849472

Siemens PLM believes that the problem you reported where the German language menus display is not correct on MacOS will be resolved by code changes made to the release of our product NX 10.

1849944

Siemens PLM believes that the problem you reported where Gaskets, inserted automatically between flanges, were not assigned an asserted weight as defined in their corresponding ptb, will be resolved by code changes made to the upcoming release of our software NX 10.

1853993

Siemens PLM believes that the problem you reported where the Fix Length on Flex Pipes does not work any longer will be resolved by code changes made to the upcoming release of our software NX 10.

1854793

Siemens PLM believes that the problem you reported where 2D exchange does not translate full bolt circles correctly will be resolved by code changes made to the upcoming release of our software NX 10.

1855558

Siemens PLM believes that the problem you reported where the Fix Length on Flex Pipes does not work any longer will be resolved by code changes made to the upcoming release of our software NX 10.

1855662

Siemens PLM believes that the problem you reported where element size for 2D mapped meshes did not provide support for expressions will be resolved by code changes made to the upcoming release of our software NX 10.

1857098

Siemens PLM believes that the problem you reported where saving an assembly raises the error "The function FCC_RollbackFileUploadedToPLM() returned the following status: Invalid ticket or invalid ticket pointer" will be resolved by code changes made to the upcoming release of our software NX 10.

1857998

Siemens PLM believes that the problem you reported where updating the value for DB_PART_NAME in the part family spreadsheet does not update the values in Teamcenter, nor the value in existing members, will be resolved by code changes made to the upcoming release of our software NX 10.The issue has been resolved by giving user feedback in the form of a pop up message, mentioning the names of all locked attributes and the fact that they are locked, hence, their values cannot be updated. It will have the behavior as follows:

1. This message will pop up only once, whether one or multiple members are selected for update from the part family spreadsheet.

2. This message would pop up irrespective of whether the user tried to update the value of any locked attribute or not.

3. If the user tried to modify the value of locked attributes, their values are not undone (i.e. reverted back to the old value). Hence, the part family spreadsheet will get saved with the new value.

The user should then change their values back to the previous value manually. This behavior is in line with Expressions attributes, where an expression value although invalid, gets saved in the spreadsheet.

1859229

Siemens PLM believes that the problem you reported where the Help pages were not found in the UDF dialog from RL workflow will be resolved by code changes made to the upcoming release of our software NX 8.5.

1860680

Siemens PLM believes that the problem you reported where Open Parasolid Multi-body parasolid makes multi-component will be resolved by code changes made to the release of our product NX Documentation Version 10.

1860704

Siemens PLM believes that the problem you reported where the NX documentation did not explain the differences between Import Parasolid and Export Parasolid, will be resolved by code changes made to the release of our product NX 10.

1862343

Siemens PLM believes that the problem you reported where Electrical Routing Sweep disappears after make change to Spline Path will be resolved by code changes made to the upcoming release of our software NX 10.

1862595

Siemens PLM believes that the problem you reported where the Formboard performance degraded in NX 7.5.3 MP3 will be resolved by code changes made to the upcoming release of our software NX 10.

1865107

Siemens PLM believes that the problem you reported where a DWG cannot be opened will be resolved by code changes made to the upcoming release of our software NX 10.

1865371

Siemens PLM believes that the problem you reported where an "Internal error: invalid solid object tag" error was raised when updating a view, will be resolved by code changes made to the upcoming release of our software NX NX 10.

1866525

Siemens PLM believes that the problem you reported where Incorrect advanced flange reforming after normal cutout is created will be resolved by code changes made to the upcoming release of our software NX 10.

With NX 10, the issue has been fixed with the Unbend/Rebend commands using following steps:

1. Switch to NX Sheet Metal (Application->Sheet Metal) if not already.

 2. Suppress or delete the Uniform, Normal Cutout and Reform features.

3. Convert to Sheet Metal, selecting the bend of Advanced Flange as the "Additional Geometries".

4. Unbend the advanced flange.

5. Apply the normal cutout across the bend. 6. Rebend the bend back to the folded status.

1868863

Siemens PLM believes that the problem you reported where Deleting a non-associative line displays a "Pre Delete Notification" error message will be resolved by code changes made to the upcoming release of our software NX 10.

1869259

Siemens PLM believes that the problem you reported where following a replace of a connector or a boot the routing B-Curve is not displayed for edit in the formboard will be resolved by code changes made to the upcoming release of our software NX 10.

1869892

Siemens PLM believes that the problem you reported where Orient Branch to Vector only moves anticlockwise to align a vector will be resolved by code changes made to the upcoming release of our software NX 10.

1870698

Siemens PLM believes that the problem you reported where Replace Component stops the Built In Path updating when Flip component is used will be resolved by code changes made to the upcoming release of our software NX 10.

1871829

Siemens PLM believes that the problem you reported where the Orient Branch command fails to move the branch will be resolved by code changes made to the upcoming release of our software NX 10.

1874283

Siemens PLM believes that the problem you reported where exporting a Flat Pattern as a GEO File using the Export Trumpf GEO File command failed with NX reporting: "Curve Topology is not valid. Loops must be closed.", will be resolved by code changes made to the upcoming release of our software NX 10.

1874908

Siemens PLM believes that the problem you reported where linked bodies are still created after Create Interpart Link has been disabled will be resolved by code changes made to the upcoming release of our software NX 10.

1875064

Siemens PLM believes that the problem you reported where "Routing -> Reuse Library -> select Piping part -> Search Children" raised an Internal error: memory access violation, will be resolved by code changes made to the upcoming release of our software NX 10.

1875891

Siemens PLM believes that the problem you reported where inserting a Routing BOM caused the NX session to terminate having applied overstock, will be resolved by code changes made to the upcoming release of our software NX 10.

1876149

Siemens PLM believes that the problem you reported where an assembly lost its Electrical Routing connections when loaded in one step, will be resolved by code changes made to the upcoming release of our software NX 10.

1878353

Siemens PLM believes that the problem you reported where the GRIP command CRSEWV fails in gripbatch mode with error 671303 'No solids found' will be resolved by code changes made to the upcoming release of our software NX 10.

1878931

Siemens PLM believes that the problem you reported where Create Interpart Link turns back on each time Spline Path dialog is opened will be resolved by code changes made to the upcoming release of our software NX 10.

1880682

Siemens PLM believes that the problem you reported where the alignment of Text is not correct when DXF imported will be resolved by code changes made to the upcoming release of our software NX 10.

1881421

Siemens PLM believes that the problem you reported where Measure Point Distance on Spline between two points was wrong, will be resolved by code changes made to the upcoming release of our software NX 10.

1881480

Siemens PLM believes that the problem you reported where a T-boot flips on formboard update after replacing a connector will be resolved by code changes made to the upcoming release of our software NX 10.

1881770

Siemens PLM believes that the problem you reported where Formboard Looses Geometry Changes Following Part Cleanup Delete Unused Objects will be resolved by code changes made to the upcoming release of our software NX 10.

1882084

Siemens PLM believes that the problem you reported where Unable to Change Part Name with Part Family Spreadsheet will be resolved by code changes made to the upcoming release of our software NX 10.

1884370

Siemens PLM believes that the problem you reported where the conversion of mating conditions in a specific assembly would fail will be resolved by code changes made to the upcoming release of our software NX 10.

1884690

Siemens PLM believes that the problem you reported where a Draft feature lost a Blended Edge, or failed completely when changing a parent Extrude to various valid values, will be resolved by code changes made to the upcoming release of our software NX 10.

1884903

Siemens PLM believes that the problem you reported where Export Trumpf Geo File failed reporting: "Curve topology is not valid. Loops must be closed.", will be resolved by code changes made to the upcoming release of our software NX 10.

1885099

Siemens PLM believes that the problem you reported where it was unable to update section views after a geometry modification will be resolved by code changes made to the upcoming release of our software NX 10.

1886169

Siemens PLM believes that the problem you reported where no constraints created when a connector is dragged from the Reuse Library will be resolved by code changes made to the upcoming release of our software NX 10.

1886947

Siemens PLM believes that the problem you reported where information on internationalization on UNIX and MAC was incomplete or missing will be resolved by code changes made to the release of our product NX 10.

1887680

Siemens PLM believes that the problem you reported where the "Create Terminals" loses the origin Routing Control Point will be resolved by code changes made to the upcoming release of our software NX 10.

1888155

Siemens PLM believes that the problem you reported where editing a Routing curve resulted in connection being lost, will be resolved by code changes made to the upcoming release of our software NX 10.

1889521

Siemens PLM believes that the problem you reported where the documentation was inadequate for the dimensions field in the UF_ASSEM_iset_array_data structure will be resolved by code changes made to the release of our software NX 10.

1889737

Siemens PLM believes that the problem you reported where creating a new formboard drawing (electrical routing) the incorrect color palette is shown will be resolved by code changes made to the upcoming release of our software NX 10.

1890831

Siemens PLM believes that the problem you reported where using Dynamic Axis while creating a Routing Path the Distance automatically snapped to "normal" value depending on the Zoom level, will be resolved by code changes made to the upcoming release of our software NX 10.

1890885

Siemens PLM believes that the problem you reported where "Error adding Point to the Spline" message is given when creating Spline Path will be resolved by code changes made to the upcoming release of our software NX 10.

1891283

Siemens PLM believes that the problem you reported Trim and Extend will be resolved by code changes made to the upcoming release of our software NX 10. However, to see the fix, the user will have to recreate Trim and Extend(62) with the value of 5mm rather than editing the existing Trim and Extend feature from 2mm to 5mm.

1891553

Siemens PLM believes that the problem you reported where there was no feedback when the user tried to update the value of DB_PART_NAME will be resolved by code changes made to the upcoming release of our software NX 10.

1892172

Siemens PLM believes that the problem you reported where placing an Altrep of a component places the original component in Routing. will be resolved by code changes made to the upcoming release of our software NX 10.

1892483

Siemens PLM believes that the problem you reported where exporting PDF fails with last error message Teamcenter Error: Internal Error, will be resolved by code changes made to the upcoming release of our software NX 10.

1893763

The problem where an NX to CATIA V5 translation resulted in missing geometry is fixed in the NX 10 and NX 9.0.3 CATIAV5 Translators. It will also be targeted for the MP's between NX versions 8.0.3 and 9.0.2.

1895073

Siemens PLM believes that the problem you reported where a Face Blend parameter change is inconsistent will be resolved by code changes made to the upcoming release of our software NX 10.

1895861

Siemens PLM believes that the problem you reported where Saving an assembly raised the error: "The function FCC_RollbackFileUploadedToPLM() returned the following status: Invalid ticket or invalid ticket pointer.", will be resolved by code changes made to the upcoming release of our software NX 10.

1896058

Siemens PLM believes that the problem you reported where a Routing path is displayed as centerline instead of Simple Solid will be resolved by code changes made to the upcoming release of our software NX 10.

1897549

Siemens PLM believes that the problem you reported where you are unable to Open Routing File (Error: Internal Memory Access Violation) will be resolved by code changes made to the upcoming release of our software NX 10.

1897779

Siemens PLM believes that the problem you reported where Listing Window to File did not work properly will be resolved by code changes made to the upcoming release of our software NX 10.

1898655

Siemens PLM believes that the problem you reported "PS27.0.50 ::Follow-up PR of DAG9335: blend face of Edge Blend(88) gone PR6687971" will be resolved by code changes made to the upcoming release of our software. This PR has been fixed in NX 10. In order to see the results the feature has to be created new. Just updating the old feature doesn't show you the desired output.

1899507

Siemens PLM believes that the problem you reported where boolean unite failed due to alert thru face does not intersect will be resolved by code changes made to the upcoming release of our software NX 10.

1899920

Siemens PLM believes that the problem you reported where JT files do not open to NX correctly will be resolved by code changes made to the release of our product NX 10. You will have to resave the Jt file in NX 10 for the Jt data to be written to part file correctly.

1899936

Siemens PLM believes that the problem you reported where NX Part families : DB_PART_NAME do not update after changes in spreadsheet will be resolved by code changes made to the upcoming release of our software NX 10.

1902248

Siemens PLM believes that the problem you reported where Analyze Formability returned wrong shapes, will be resolved by code changes made to the upcoming release of our software NX 10.

1902263

Siemens PLM believes that the problem you reported where Auto Stitch is not successful, will be resolved by code changes made to the upcoming release of our software NX 10.

1902449

Siemens PLM believes that the problem you reported where the feature side cannot be specified when it needs to be reversed while using the One-step-Formability will be resolved by code changes made to the upcoming release of our software NX 10.

1903099

Siemens PLM believes that the problem you reported where it was not possible to add the Threads of a Threaded Hole applied to a Promoted Body to the Model Reference Set, will be resolved by code changes made to the upcoming release of our software NX 10.

1903421

Siemens PLM believes that the problem you reported where a patter will not update a threaded hole correctly, will be resolved by code changes made to the upcoming release of our software NX 10.

1904602

Siemens PLM believes that the problem you reported where UF_PLIST_list doesn't write to file device by uc4400 as of NX 8 will be resolved by code changes made to the release of our product NX 10.

1904650

Siemens PLM believes that the problem you reported where an internal error was raised editing stock and changing to Transform Path dialog, will be resolved by code changes made to the upcoming release of our software NX 10.

1904770

Siemens PLM believes that the problem you reported where the error "Expressions of Thread and Feature Diameters are out of sync" was raised when adding a symbolic thread, will be resolved by code changes made to the upcoming release of our software NX 10.

1904804

Siemens PLM believes that the problem you reported where he Default browse folder was not retained when restarting NX will be resolved by code changes made to the upcoming release of our software NX 10.

1905998

Siemens PLM believes that the problem you reported where a NXOpen Error "No automation class for tag: nnnnn, class: DesignRuleFunction" occurs for type/subtype UF_design_rule_type=188 and UF_design_rule_function_subtype=3 will be resolved by code changes made to the upcoming release of our software NX 10.

1906012

Siemens PLM believes that the problem you reported where NX 6.0.5.3 Grooving operations generated in NX 7.5 no longer output the Delta move specified for the Start Point will be resolved by code changes made to the upcoming releases of our software NX 9.0.2 and NX 10.

1906467

Siemens PLM believes that the problem you reported where there was an issue with setting the snap increment default on move command, will be resolved by code changes made to the upcoming release of our software NX 10.

1906764

Siemens PLM believes that the problem you reported where "French language with non-ASCII characters are rejected when renaming objects in the Advanced Simulation" will be resolved by code changes made to the release of our product version NX 10.

1906858

Siemens PLM believes that the problem you reported where "Turning : Stop position Point are Ignored in NX 7.5.5 and NX 8.0.2" will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10.

1907779

Siemens PLM believes that the problem you reported where: Edit reusable component will not update the drawing dimensions accordingly will be resolved by code changes made to the release of our software NX 10.

1907961

Siemens PLM believes that the problem you reported where Projected Curve (points) when inserting UDF raises: "Missing section string", will be resolved by code changes made to the upcoming release of our software NX 10.

1908050

Siemens PLM believes that the problem you reported where an error, "The following links had their reference geometry consumed", occurs while updating links will be resolved by code changes made to the upcoming release of our software NX 10.

1908235

Siemens PLM believes that the problem you reported where a Thickened Mirror Body was not uniform, will be resolved by code changes made to the upcoming release of our software NX 10.

1908351

Siemens PLM believes that the problem you reported where exporting a Flat Pattern as a GEO File, using the Export Trumpf GEO File command, raised the error: "Curve Topology is not valid. Loops must be closed" and the export failed, will be resolved by code changes made to the upcoming release of our software NX 10.

1909960

Siemens PLM believes that the problem you reported where there are Inconsistent Check-Mate Results for Examine Geometry will be resolved by code changes made to the release of our product NX 10.

1910255

Siemens PLM believes that the problem you reported where Replace Deformable Cable in Routing uses all available memory will be resolved by code changes made to the upcoming release of our software NX 10.

1910555

Siemens PLM believes that the problem you reported where an Internal error was raised when editing the size of Space Reservation, will be resolved by code changes made to the upcoming release of our software NX 10.

1912087

Siemens PLM believes that the problem you reported where not all objects were placed on the Original layer when a UDF was added with the layer option set to "Original", will be resolved by code changes made to the upcoming release of our software NX 10.

1912092

Siemens PLM believes that the problem you reported where Apply customer defaults to all menus will be resolved by code changes made to the upcoming release of our software NX 10.

1913341

Siemens PLM believes that the problem you reported where "Tool class mapping table is incomplete/incorrect in NX documentation" will be fixed in NX 10.

1914127

Siemens PLM believes that the problem you reported where NX takes too long to delete update pending meshes when edge matching is used will be resolved by code changes made to the upcoming release of our software NX version 10.

1914357

Siemens PLM believes that the problem you reported where Checker %mqc_update_all_drawings is not working as documented will be resolved by code changes made to the upcoming release of our software NX 10.The documentation of Check-Mate function mqc_updateAllDrawings has been fixed in NX 10.0 to indicate whether all drawing objects can be regenerated correctly. The function is used by the Update All Drawings checker to report drawing objects which can not be regenerated correctly or are not constant before and after drawing view update. In the PR case, three annotation objects are not constant due to position changes after update. After the user updates all drawing views, the annotation objects are also updated in the drawing views. The Update All Drawings checker passes because these annotation objects have constant positions before and after the latest update.

1915124

Siemens PLM believes that the problem you reported where xy function curves display as continuous lines, or part continuous/part discontinuous lines, even though the selected display line style is one of the discontinuous (dashed) line styles, will be resolved by code changes made to the upcoming release of our software NX 10.

1915304

The problem where defining assembly constraints in this assembly could be slow is fixed in NX 10. Major improvements have been made in the performance from NX 6 to NX 8, and a typical operation on this assembly has been made four times faster still in NX 10.

1915594

Siemens PLM believes that the problem you reported where No refresh of TC information in NX Mgr Title Bar and Windows-dropdown will be resolved by code changes made to the upcoming release of our software NX 10.

The problem is fixed in NX 10 since:

1. The customer default "Show Item Name instead of Number" is no more valid.

2. NX now honors the item revision display name in Teamcenter which is the object_string property. So the display name in TC RAC My Navigator and NX would now be consistent.

1916055

Siemens PLM believes that the problem you reported where Create Post Action on update Sheet/Drawing will be resolved by code changes made to the upcoming release of our software NX 10.

1916357

Siemens PLM believes that the problem you reported where Placing Fitting results in conflicting constraint and remove part deletes RCP will be resolved by code changes made to the upcoming release of our software NX 10.

1916729

Siemens PLM believes that the problem you reported where there is an incorrect NCM engage movement when using swing angle and 3D IPW will be resolved by code changes made to the upcoming release of our software NX 10. The swing angle in non-cutting moves will now be processed when using 3D IPW for surface contouring operations.

1917390

Siemens PLM believes that the problem you reported where an error appears with load/delete component from assembly will be resolved by code changes made to the upcoming release of our software NX 10.

1917799

Siemens PLM believes that the problem you reported where Sketch in view: edit-curve-stretch: no rectangle selection available will be resolved by code changes made to the release of our product NX 10.

1919400

Siemens PLM believes that the problem you reported where mechanical routing loses associations to reference geometry will be resolved by code changes made to the upcoming release of our software. This PR is validated against ugnx7554_mp10 and found to be RESOLVED. This PR is validated against NX 10.0.0.8 and found to be RESOLVED.

1919885

Siemens PLM believes that the problem you reported where the graphics display is not updated fully after changes to formboard layout branch angles, will be resolved by code changes made to the upcoming release of our software NX 10.

1919926

Siemens PLM believes that the problem you reported where Additional Ports are created following formboard branch angle change will be resolved by code changes made to the upcoming release of our software NX 10.

1919950

Siemens PLM believes that the problem you reported where additional RCPs are shown on the formboard following a branch angle change, will be resolved by code changes made to the upcoming release of our software NX 10.

1920122

Siemens PLM believes that the problem you reported where the Blockstyler ListBox 'ShowAddButton' property shows the button in a wrong location when called in the Update cb will be resolved by code changes made to the upcoming release of our software NX 10.

1920160

Siemens PLM believes that the problem you reported where Routing Mechanical - Stock component folder in Teamcenter not populated will be resolved by code changes made to the upcoming release of our software NX 10 and all subsequent releases.

1920196

Siemens PLM believes that the problem you reported where Setting the ListBox properties "SingleSelect" and "MaximumStringLength" works in Initialize cb only will be resolved by code changes made to the documentation of our software NX 10. The Block UI Styler List Box block documentation was incorrect and has been updated for those properties to state now the correct access "CIG" (Creation/Initialize/Set).

1920336

Siemens PLM believes that the problem you reported where Visualize shows two entries for some circular contact contour motions in the list view will be resolved by code changes made to the upcoming release of our software NX 9.0.3

1920815

Siemens PLM believes that the problem you reported where Three bend corner does not work on 90 degree bends will be resolved by code changes made to the upcoming release of our software NX 10.

1921157

Siemens PLM believes that the problem you reported where Circular update Error after changing Distance Constrains for Spun Outline will be resolved by code changes made to the upcoming release of our software NX 10.

1922693

Siemens PLM believes that the problem you reported where "Pipe does not get Cut when Inserting multiple Comp" will be resolved by code changes made to the upcoming release of our software NX 10.0.0.8. This PR is validated against NX 7.5.5.4 (ugmenu) and found to be REPRODUCIBLE. This PR is validated against NX 10.0.0.8 as a part of PR cleaning activity and found to be RESOLVED. Hence, closing this PR as FX.

1922771

PSv27.0.51 FaceBlend -> Overriding Trim Objects on sheets not working.

1922788

Siemens PLM believes that the problem you reported where "open file" fails with Internal Error, will be resolved by code changes made to the upcoming release of our software NX 10.

1922867

Siemens PLM believes that the problem you reported where NX 8: WCS Axis handles can't be selected will be resolved by code changes made to the upcoming release of our software NX 10.

1922877

(PS27.00.041) Thicken of a Sheet Body is inconsistent.

1923522

Siemens PLM believes that the problem you reported where slope analysis displays incorrectly in assembly context will be resolved by code changes made to the upcoming release of our software NX 10.

1924422

Siemens PLM believes that the problem you reported where Pattern->Retrieve Pattern will cause Internal error will be resolved by code changes made to the upcoming release of our software NX 10. You have to save the part file containing the pattern in NX 10 to update the part so that the change can take effect.

1924481

Siemens PLM believes that the problem you reported where File->Export->2D Exchange delivers a result where arcs have the "wrong" direction will be resolved by code changes made to the upcoming release of our software NX 10.

1925233

Siemens PLM believes that the problem you reported where Documentation for new Chamfer and Spherical Mill is missing will be resolved by code changes made to the upcoming release of our software NX 10

1925610

Siemens PLM believes that the problem you reported where a Routing control point does not follow the mouse will be resolved by code changes made to the upcoming release of our software. This PR is validated against NX 10.

1926409

Siemens PLM believes that the problem you reported where Save part raises an error will be resolved by code changes made to the upcoming release of our software NX 10.

1928836

Siemens PLM believes that the problem you reported where SMD- SB- Closed Corner failed will be resolved by code changes made to the upcoming release of our software NX 10.

1929341

Siemens PLM believes that the problem you reported where you were Unable to Orient Specific Branches in Formboard will be resolved by code changes made to the upcoming release of our software NX 10.

1929373

Siemens PLM believes that the problem you reported where Orient branch fails in formboard will be resolved by code changes made to the upcoming release of our software NX 10.

1929804

Siemens PLM believes that the problem you reported where "the Stress Wizard legend may be partially clipped" will be resolved by code changes made to the release of our product NX 10.

1929968

Siemens PLM believes that the problem you reported with a wrong positioned component after JT import will be resolved by code changes made to the release of our product. The problem where the components of a particular JT assembly file are not in the appropriate location has been fixed in NX 8.0.1. For some unknown reason that same fix did not carry over into the NX 8.5, NX 9 releases, but the fix is definitely in NX 10.

1930095

Siemens PLM believes that the problem you reported where Ribbon Builder - Icon wrong will be resolved by code changes made to the upcoming release of our software NX 10.0.0.12

1930943

Siemens PLM believes that the problem you reported where Formboard with 0 discrepancies in NX 7.5.3 has many discrepancies in later versions will be resolved by code changes made to the upcoming release of our software NX 10.In this version the formboard shows zero discrepancies.

1931007

Siemens PLM believes that the problem you reported where creating a Bounded Plane with outer and inner loop fails with "Unable to reference edge" will be resolved by code changes made to the upcoming release of our software NX 10.

1931040

The problem where NX doesn't update a datum plane after editing its associated parent is fixed in release NX 10.

1931287

Siemens PLM believes that the problem you reported where Suppressed Toolpath is not continuously stored inside NX (Reply and Verify shows him ; Listing and Post not) will be resolved by code changes made to the upcoming release of our software NX 9.0.3.

1931395

Siemens PLM believes that the problem you reported with Delete Face mismatch between Surface and Solid will be resolved by code changes made to the upcoming release of our software. From NX 10, a new delete face type "Blend" is developed, lots of blends on sheet can be deleted successfully with this type. If needed, user can optimize (with optimize face command) input body firstly to improve the face deletion rate.

1931905

Siemens PLM believes that the problem you reported where Part Cleanup Deactivate UDE for In Path Events will be resolved by code changes made to the upcoming release of our software NX 10.

1932869

Siemens PLM believes that the problem you reported where Preview display of cable splits when using Spline Path to move RCP will be resolved by code changes made to the upcoming release of our software NX 10.

1932967

Siemens PLM believes that the problem you reported where User interface Contact Parameters needs percentage input, not factor input will be resolved by code changes made to the upcoming release of our software NX 10.

1933218

Siemens PLM believes that the problem you reported where the NX 8.5 NXOpen documentation refers to an invalid method "Session.GetEnvironmentVariable" will be resolved by code changes made to the upcoming release of our software NX 10.

1933456

Siemens PLM believes that the problem you reported where Unroute function very slow performance will be resolved by code changes made to the upcoming release of our software NX 10.

1934757

Siemens PLM believes that the problem you reported where Crosshatch boundary curves do not highlight during editing, will be resolved by code changes made to the upcoming release of our software NX 10.

1935054

Siemens PLM believes that the problem you reported where Connector part will flip during move part when there are multiple routing paths will be resolved by code changes made to the upcoming release of our software NX 10.

1935197

Siemens PLM believes that the problem you reported where using the KF UI component ui_comp_angular_dim the Radius value of the handle is not scaling correctly will be resolved by code changes made to the release of our product NX 10.

1935335

Siemens PLM believes that the problem you reported where update_fam_from_ptb fails when using -pim=yes will be resolved by code changes made to the upcoming release of our software NX 10.

1935810

Siemens PLM believes that the problem you reported where Sketch shows Fully Constrained even after driving dimension is removed will be resolved by code changes made to the upcoming release of our software NX 10.

1936116

Siemens PLM believes that the problem you reported where deviation gauge - wrong result will be resolved by code changes made to the upcoming release of our software. The problem is fixed in NX 10.

1936145

Siemens PLM believes that the problem you reported where No dataset is created when creating constraints, after adding pending components, will be resolved by code changes made to the upcoming release of our software NX 10.The issue where the dataset is not saved after constraint creation is fixed in NX 10.Also a simple workaround for this is to simply do a "save" prior to creating the constraint in NX. An alternative workaround is to set the customer default "add NX dataset" to "always".

1936244

Siemens PLM believes that the problem you reported where Internal Error with PTS UI in NX 8.5 will be resolved by code changes made to the upcoming release of our software NX 10. It looks like the primary problem was that the spreadsheet for one of the expressions was not being found. I think a part of that issue is that we should not have evaluated the expression as the part is opening in PTS. That has been fixed previously in NX 9 and NX 10. A second issue is how errors are being processed from a KF/Comp dialog, which has also been previously addressed in NX 9 and NX 10. There is also an issue with opening this part in NX 10, where the simulation parts have been renamed and not re-authored in PTS. The NX 10 version of PTS was not able to find the simulation with the part getting renamed - and that is now fixed.

1936311

Siemens PLM believes that the problem you reported where "Incorrect NCM engage movement when using swing angle and 3D IPW" will be resolved by code changes made to the upcoming release of our software NX 10.

1936715

Siemens PLM believes that the problem you reported where the UDF edit dialog had wrong boolean value selected, will be resolved by code changes made to the upcoming release of our software NX 10.

1936951

Siemens PLM believes that the problem you reported where Linked body feature is not updated opening assembly with interpart data loaded will be resolved by code changes made to the upcoming release of our software NX 8.5.3.

1937382

Siemens PLM believes that the problem you reported where Increase the Multi-Segment Bends in the Lofted Flange feature will be resolved by code changes made to the upcoming release of our software NX 10.

1937569

Siemens PLM believes that the problem you reported where "Mirror Feature fails when sketch points positioned by positioning dimensions" will be resolved by code changes made to the upcoming release of our software NX 10.

1937979

Siemens PLM believes that the problem you reported where "Extract Body causes Face Blend error" will be resolved by code changes made to the upcoming release of our software NX 10.

1937993

Siemens PLM believes that the problem you reported where macro execution fails on Linux platforms if the macro tries to load a file with spaces in path will be resolved by code changes made to the upcoming release of our software NX 10.

1938361

Siemens PLM believes that the problem you reported where Microposition in Curve on Surface does not work as it should will be resolved by code changes made to the upcoming release of our software. Siemens PLM believes that the problem you reported where microposition in curve on surface does not work as it should will be resolved by code changes made to the upcoming release of our software NX 9.

1938638

Siemens PLM believes that the problem you reported with the documentation of microposition in Curve on Surface is incorrect / incomplete will be resolved by code changes made to the upcoming release of our software. This problem is fixed in NX 9.0 and later. Rewrote the text for the Rate option under Micropositioning: Lets you specify the relative amount of movement required to drag a handle in order to move the corresponding constraint point. This is especially useful for very fine curve point editing.

 Select the Rate box and specify a value between 0.01% and 100%.

 Lower values produce finer constraint point movement.  You must press and hold the Alt key as you drag a constraint point handle to enable the Micropositioning rate.

Note Pressing and holding the Alt key as you drag constraint points also disables Snap Point.

1939422

Siemens PLM believes that the problem you reported where "Solid Body causes error with Face Blend" will be resolved by code changes made to the upcoming release of our software NX 10 Note that Face Blend dialog has gone through some enhancements in NX 10 IP10.

1939424

Siemens PLM believes that the problem you reported where Variable Face Blend causes bad data quality will be resolved by code changes made to the upcoming release of our software NX 10.

1939905

Siemens PLM believes that the problem you reported where the online help for udf's is not working will be resolved by code changes made to the upcoming release of our software NX 10.

1939923

Siemens PLM believes that the problem you reported where the display of the MCD sequence editor was wrong will be resolved by code changes made to the upcoming release of our software NX 10.

1940230

Siemens PLM believes that the problem you reported where Offset Face creates self-intersection will be resolved by code changes made to the upcoming release of our software NX 10.

1940286

Siemens PLM believes that the problem you reported where Move Customer Symbols/Symbols takes a long time will be resolved by code changes made to the upcoming release of our software NX 10.

1941152

Siemens PLM believes that the problem you reported where, when creating a point, the Point Type changes to Cursor Location when the Associative toggle is unchecked, will be resolved by code changes made in the NX 10 release. The behaviour will be modified so that when the Point Type is something other than Inferred, and no geometry has been selected, changing the Associative toggle will not change the type.

1941410

Siemens PLM believes that the problem you reported where Face Blend fails at easy geometry will be resolved by code changes made to the upcoming release of our software NX 10.

1941885

Siemens PLM believes that the problem you reported where Trumpf Geo Export fails - Curve topology is not valid. Loops must be closed, will be resolved by code changes made to the upcoming release of our software NX 10.

1943501

Siemens PLM believes that the problem you reported where the NXOpen method DraftingViewCollection.UpdateViews(DraftingViewCollection.ViewUpdateOption.All) doesn't update one specific member view will be resolved by code changes made to the upcoming release of our software NX 10.

1943662

The problem where some notes end up referencing a wrong attribute has been fixed in release NX 8.5.3. To prevent this from happening, the system will now generate an error when an application attempts to set wrong references to attributes. Unfortunately, this fix will not clean up old parts with this problem. If such cleanup is necessary (due to a large number of parts), please submit a new PR to Drafting. The problem where in some cases, references by annotations to PDM-based attributes have gone away has been fixed in release NX 10. The fix is also backported to previous releases. Loading the part in question, running the part fixup (no selections needed) and saving the part should fix the references.

1943979

Siemens PLM believes that the problem you reported where the NX Open Programmers Guide contains an obsolete link to "How NX finds application files" will be resolved by code changes made to the upcoming release of our software NX 10.

1944211

Siemens PLM believes that the problem you reported with No Thread Information on Pattern Feature with Extracted Bodies will be resolved by code changes made to the upcoming release of our software NX 10.With this change, Symbolic threads are inherited from extracts when participating in Pattern in both simple and variational methods.

1944611

Siemens PLM believes that the problem you reported where KF Applications UI becomes grayed out with faulty %ui_comp class definition will be resolved by code changes made to the release of our product NX 10. The problem where the error "Invalid User Dialog" is displayed after pressing escape is by design. The KF uicomp classes can generate errors that are only detectable during the display of the dialog. However, the problem where the example in the documentation needs to be modified has been fixed.

1944731

Siemens PLM believes that the problem you reported where there is an error closing parts after Auto Route operation has failed, will be resolved by code changes made to the upcoming release of our software NX 10.

1945065

The problem where PTS String Item shows wrong List of Choices once modified in NX 8.5 has been investigated and the following has been found. model_GEO1: This is a problem where there are two widgets for Variant trying to show the value of the same expression in NX where one is visible and one is invisible at any given time. When widget 1 changes the value, then widget 2 is not in sync. When it becomes visible it is not showing the correct value and does not run through update to get the dialog rebuilt. It would be a fairly significant enhancement for PTS to recognize when a dialog contains two widgets driving the same variable and try to generate code to keep them in sync and get the dialog to update properly.

Workaround: The alternative is to use list expressions for Variant and also the Laenge, Breite, and Hoehe lists since they are dynamic. So you would make two list expressions in NX for the list of choices for Variente. List 1, Variant_A, would contain {"Bitte_waelhen", "1", "2"} and a second list, Variant_B, would contain {"Bitte_waelhen", "3", "4"}. Then I made a selector, Variant_choices, with an if statement if ( Typ = "A" ) then Variant_A else Variant_B The expression Vairant_choices is then used with the list expression for Variant in the PTS dialog. The option for Allow the list content to change dynamically is clicked on. You then have one group for Laenge, Breite and Hoehe which will be visible when Variant is not Bitte_waelhen. There will be several list expressions for Laenge, Breite and Hoehe to allow for the various values of Variant. That gets close, but then the NX variables don't change to match up with the content of the lists, which means it is hard to follow. Since NX 8.5 will add the current value to the list the dialog shows the current values, but those values are not appropriate for the settings. What I think the intent with having "Bitte_waehlen" in the list is to make this the current value when the type or variant changes. I made visual rules to do this in PTS. Now when you change Type, then Variant becomes "Bitte_waehlen" and the group for laenge, Breite and Hoehe becomes invisible until Variant is selected. I uploaded this part, model_GEO1_lists.prt, to the PR data page. Finally: For NX 10, we added a new option where you can restore the old behavior of not adding the current value to the list of options. The list of choices will then work just like it did in NX 7.5. Since this requires a new translated field it is not something you can do in all releases. Also, as a bit of a workaround - if you have the lists return the index instead of the indexed value it does not add the current value to the list. That does require a slight change in the expressions to add a index value and then set the real expression from the index in NX, but it would avoid the new behavior.

1945305

Siemens PLM believes that the problem with finding the proper inflection point on the curve for distance measurement will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014.

1945653

Siemens PLM believes that the problem you reported where "the MB3 on tree list item displays incorrect context menu" will be resolved by code changes made to the upcoming release of our software NX 10.

1945952

Siemens PLM believes that the problem you reported where Section view problems after edit expression in modeling will be resolved by code changes made to the upcoming release of our software NX 10.

1946438

Siemens PLM believes that the problem you reported where Ownership of infodba Home folder influences NX will be resolved by code changes made to the upcoming release of our software NX 10.

1946576

Siemens PLM believes that the problem you reported where "Error message appear closing parts with electrical routing objects". will be resolved by code changes made to the upcoming release of our software NX 10.

1946706

Siemens PLM believes that the problem you reported where returning non-zero in Blockstyler OK callback shows unexpected error message will be resolved by code changes made to the upcoming release of our software NX 10. The new message displayed if the return value is other than 0 or 1 now is "Only 0 or 1 should be returned from OK, Apply, and Close callbacks. All non-zero return values will be converted to 1."

1946745

Siemens PLM believes that the problem you reported with a playback error on edge blend nr1 will be resolved by code changes made to the upcoming release of our software NX 10. Verified to work in NX 10 with the new parasolid version 27.0.102. However, this blend needs to be deleted and recreated in nx10 to get the proper timestamp so that the correct software is used. Parasolid states this change cannot be backport to previous NX versions.

1946839

Siemens PLM believes that the problem you reported where Automatic Spun-Outline for Partgeometry does not work will be resolved by code changes made to the upcoming release of our software NX 10.

1947151

Siemens PLM believes that the problem you reported where edges edited by View Dependent Edit disappear when Hidden Lines set to Invisible, will be resolved by code changes made to the release of our product NX 10. The procedure is documented in an article entitled "Display only view dependently edited hidden lines" within the NX Drafting Help.

1947224

The problem where Feature Update Failed has been investigated and the following has been found. The failing feature in the given part has been fixed in NX901. As this fix has been version protected new feature has to be created in the place of old one to see the fix. The old one continues to fail. Repaired Part can be download here: http://download.industrysoftware.automation.siemens.com/special.php/returned/19 47224_RepairedPart-clean.7z

1947371

Siemens PLM believes that the problem you reported where the Dimension on hole datum symbol is incorrect (Custom Symbol) will be resolved by code changes made to the upcoming release of our software NX 10.

1947512

The problem where "result files cannot be deleted after NX Nastran job fails" has been investigated and the following has been found: We are closing this problem report for now, because we cannot duplicate this and have not heard back from you about a video showing the problem. We will reopen it, once we get a video showing the issue.

1947535

Siemens PLM believes that the problem you reported where there are Extra RCPs found during formboard update and no discrepancies in NX 7.5.3 MP5 will be resolved by code changes made to the upcoming release of our software NX 10.

1947807

Siemens PLM believes that the problem you reported where a part cannot be opened using NX 7.5 will be resolved by code changes made to the upcoming release of our software NX 10. Furthermore the provided part has been repaired and provided to the customer.

1947860

Problem where Internal error: memory access violation (11) by load from tc fixed in NX 10. Now part will get opened properly but user need to do part cleanup once part opened.

1948130

The problem where poor performances and other inconsistencies are observed with Broken Views on large assemblies is fixed in NX 10.

1948402

Siemens PLM believes that the problem you reported where Overstock cannot be used correctly without other routing nodes present will be resolved by code changes made to the release of our product NX 10.

1948558

Siemens PLM believes that the problem you reported where the UFWrapper AskBreakoutData fails with SafeArrayTypeMismatchException will be resolved by code changes made to the upcoming release of our software NX 10.

1948914

Siemens PLM believes that the problem you reported where the NXOpen method DraftingCustomSymbolBuilder.GetArbitraryNoteTitle() doesn't return any strings will be resolved by code changes made to the release of our product NX 10 by extending the documentation.

1948971

Siemens PLM believes that the problem you reported where "plot thickness contours command on a given group of shell elements is not possible" will be resolved by code changes made to the upcoming release of our software NX 10.

1949159

Siemens PLM believes that the problem you reported with "Inconsistent Drafted Boss" will be resolved by code changes made to the upcoming release of our software NX 10.

1949213

UGMGR: Unable to open Assembly - *NX_Nav_.plmxml - Part is not currently loaded

1949305

Siemens PLM believes that the problem you reported where the edit section line toolbar button is not working will be resolved by code changes made to the upcoming release of our software. The problem where edit section line toolbar button not working is fixed in release NX 10.

1949406

Siemens PLM believes that the problem you reported where Draft do not updated correctly from NX6 to NX 8.5 will be resolved by code changes made to the upcoming release of our software NX 10. (The culprit features draft(21) and draft(22) needs to recreate in the NX 10 to get the correct result.)

1949592

Siemens PLM believes that the problem you reported where UF_ASSEM_create_ref_set allows to create an "ENTIRE PART" Reference Set will be resolved by code changes made to the upcoming release of our software NX 10.

1949894

Siemens PLM believes that the problem you reported where the documentation needs to explain how to pass arguments to Journals from Menuscript will be resolved by code changes made to the upcoming release of our software NX 10.

1949922

Siemens PLM believes that the problem you reported where "Redefine Hinge Line is not able to select Center point" will be resolved by code changes made to the upcoming release of our software NX 10.

1949955

Siemens PLM believes that the problem you reported where Combo String ListItems from a parent SetList block cannot be populated will be resolved by code changes made to the upcoming release of our software NX 10.

1949978

Siemens PLM believes that the problem you reported where NX crashed after editing a sketcher will be resolved by code changes made to the upcoming release of our software NX 10.

1950095

Siemens PLM believes that the problem you reported where Unable to add a additional flange will be resolved by code changes made to the upcoming release of our Software NX 10.

1950102

Siemens PLM believes that the problem you reported where unable to attached a flange on an arbitrary edge will be resolved by code changes made to the upcoming release of our software NX 10.

1950324

Siemens PLM believes that the problem you reported where Section line looses model associatively will be resolved by code changes made to the upcoming release of our software NX 10.

1950331

Siemens PLM believes that the problem you reported where Updating a parent view hides a Detail View Label if 'Delay View Update' is turned off will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 0.

1950451

Siemens PLM believes that the problem you reported where "Mac OS: Italian language font problem" will be resolved by code changes made to the release of our product NX 10.

1950648

Siemens PLM believes that the problem you reported where Override position for ref-only parts fails when edits made in Structure Manager, will be resolved by code changes made to the upcoming release of our software NX 10. The problem where a position override in NX could be deleted on load if that override was associated with a reference-only component has been fixed. The fix will appear in the release version of NX 10.

1950745

Siemens PLM believes that the problem you reported where NX 8.5 exports part attributes only to the parts parent assembly will be resolved by code changes made to the upcoming release of our software NX 10.

1950904

Siemens PLM believes that the problem you reported where "Milling Workpiece has never been supported for creating a spun outline in a Turning workpiece group" will be resolved by code changes made to the upcoming release of our software NX 10.. A note stating the softwares intention of spun blank has been added to this section of TDOC (technical documentation).

1951072

Siemens PLM believes that the problem you reported where the sketch doesn't change the view orientation after reattach will be resolved by code changes made to the upcoming release of our software NX 10.

1951087

Siemens PLM believes that the problem you reported where you could not open a Routing part: Null pointer supplied to Routing will be resolved by code changes made to the upcoming release of our software. This PR is validated against NX 10.

1951163

Siemens PLM believes that the Problem with a flange in NX Sheet Metal will be resolved by code changes made to the upcoming release of our software. The Problem with flange in NX Sheet Metal looks to be fixed in NX 10. If there is any such Flange in failed state, then perform Feature Playback to fix it.

1951330

Siemens PLM believes that the problem you reported where the Journal Indicator for 'Preferences -> Teamcenter Integration' was missing will be resolved by code changes made to the upcoming release of our software NX 10.

1951356

Siemens PLM believes that the problem you reported where Safety factor colour is incorrect in Stress wizard will be resolved by code changes made to the release of our product NX 10. The problem where Safety factor colour is incorrect in Stress wizard has been investigated and the following has been found. I could not replicate this problem, even using the exact same steps the user outlined.

1951388

Siemens PLM believes that the problem you reported where Component in an array has the wrong attributes, will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 10.

1951493

Siemens PLM believes that the problem you reported where view dependent edits vanish when "Hidden Line" option is set to Invisible will be resolved by code changes made to the release of our product NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them.

1951575

Siemens PLM believes that the problem you reported where the Status Area does not accurately reflect the count of selected objects after selecting or de-selecting certain objects, such as the top assembly or expressions, in a navigator will be resolved by code changes made to the upcoming release of our software NX 10.

1951941

The problem where feature update fails in NX 8.5 has been investigated and the following has been found. The root cause of the problem is the Stationary reference input, Datum plane, to the Draft(184) is missing. Most likely it would have been deleted. Despite this deletion the feature works fine until NX 8 but not from NX 8.5 onwards in which there had been major enhancements in Draft feature. Therefore any pre NX.85 draft, whose stationary plane has been deleted, will fail update from NX 8.5 onwards. Cases like these are very rare if not zero as in this case. In NX 10, we provided a fix to prevent this problem. So from NX 10 onwards these type of features , in which their Stationary plane is deleted, will also update without any problem. For technical reasons this fix can't be made available in NX 8.5 and NX 9. Coming to the solution for NX 8.5, we have a simple work around for this PR. As the datum plane input for Draft(184) has been deleted, creating in NX 6 a similar Datum plane as the one used in Draft(184) and using it as input for Draft(184) in the place of existing one would solve the problem. I have repaired the part in NX 6 using the method described above and the part passes playback cleanly. This part will be send by another Email to you ( per Siemens SECUFEX) (IR1951941_4222-027-21330-C_Draft-184_RepairedInNX605.7z)

1951982

Siemens PLM believes that the problem you reported where trim and Extend fails in NX 8.5.2.3 in NX 6.0.2.8 it works will be resolved by code changes made to the upcoming release of our software NX 10. The PR has been fixed in NX 10. However, the user will have to recreate Trim and Extend(8) to see the fix. Since this fix cannot be backported to NX 8.5.3.2, there is a workaround suggested. The problem is that instead of extending 14 edges of the OffsetSurface(7), 12 edges are extended. The other 2 edges are extended by the same parameters as another feature.

So the work around is to

1. make Trim And Extend(8) current feature,

2. EWR Trim And Extend(8), de-select the front bottom two edges.

3. Insert Trim and Extend and select the de-selected edges with the same input parameters.

4. Update to End.

1952112

Siemens PLM believes that the problem you reported where retrieving radio box control items with UF_STYLER_SUBITEM_VALUES causes crash will be resolved by code changes made to the upcoming release of our software NX 10.

1952186

Siemens PLM believes that the problem you reported where Flat pattern failed if solid cut under 90 degrees will be resolved by code changes made to the upcoming release of our software NX 10.

1952263

The problem where "Incorrect dimple with circular or elliptical Curve" is fixed in release NX 10. To get the fix, user need to re-create Dimple feature in NX 10 or future release.

1952331

The problem of the guide curve changing on edit does not happen in NX 10. with the new Weld Point Wizard. The used created is on the screen after create and is reused on edit.

1952362

The problem where the Check-Mate Help needed additional information about the Part Save option on the Author Tests dialog box (Create/Edit Profile tab). In order for a profile to be run when a part is saved, three environment variables must be set. This problem is fixed in release NX 10.

1952681

Siemens PLM believes that the problem you reported where Trim and Extend(8) fails in NX 8.5.2.3 MP1 will be resolved by code changes made to the upcoming release of our software NX 10. The PR has been fixed in NX 10. However, the user will have to recreate Trim and Extend(8) to see the fix. Since this fix cannot be back ported to NX 8.5.3, there is a workaround suggested. The problem is that instead of extending 14 edges of the Offset Surface(7), 12 edges are extended. The other 2 edges are extended by the same parameters as another feature.

So the work around is to:

1. Make Trim And Extend(8) current feature,

2. Edit with Rollback Trim And Extend(8), de-select the front bottom two edges.

3. Insert Trim and Extend and select the de-selected edges with the same input parameters.

4. Update to End. Reworked parts can be made available when requested.

1952907

Siemens PLM believes that the problem you reported with internal error in formboard part dependent to overstock will be resolved by code changes made to the upcoming release of our software NX 10.

1952973

The problem where in some cases, references by annotations to PDM-based attributes have gone away has been fixed in release NX 10. The fix is also backported to previous releases. Loading the part in question, running the part cleanup (no selections needed) and saving the part should fix the references. Newest information of development: The fix will be added to NX 8.5.3 MP2 and customer agreed with that. This Maintenance Pack is planned to be ready for customer download on 14-Mar-2014.

1953119

Siemens PLM believes that the problem you reported where the VRML Export fails when part names contain dots will be resolved by code changes made to the upcoming release of our software. The problem with file names being created incorrectly when the original name contains a dot has been addressed in NX 10.

1953173

Siemens PLM believes that the problem you reported where "4222-249-08520_Draft(84) fails in NX 8.5.2.3 MP1" will be resolved by code changes made to the upcoming release of our software NX 9.0. This is the second time this CRR is sent. This PR 1953173 has been linked to 1953176, as it has a similar cause. But PR1953173 forms a special case of PR1953176 in that the stationary reference is perpendicular to the draw direction in PR1953173. Because of this special condition the PR is found to be fixed in NX 9 and hence we marked it as FN in NX 9 earlier. A remark from development: The reason for the failure i.e. deleting the stationary plane after draft is made and we don't recommend that as it is not a good practice to delete the plane after its use is over. =============================================================================== The root cause of the problem is that the Stationary reference input, Datum plane, to the Draft(84) is missing. Most likely it would have been deleted and I believe that NX has no role in this deletion. Despite this deletion the feature works fine until NX 8 but not from NX 8.5 onwards in which there had been major enhancements in Draft feature. Therefore any preNX 8.5 draft, whose stationary plane has been deleted, will fail update from NX 8.5 onwards. Cases like these are very rare if not zero as in this case. Anyway this problem has been rectified in NX 9 and the part passes playback successfully in NX 9. Coming to the solution for NX 8.5, we have a simple work around for this PR. As the datum plane input for Draft(84) has been deleted, creating in NX 6 a similar Datum plane/ Point (in this case as the Plane is perpendicular to Draw direction) as the one used for Draft(84) and using it as input for Draft(84) in the place of existing one would solve the problem. Open the Part in NX 6 --> Edit With Rollback Draft(84) --> De-select the 'Stationary Plane' Input --> Click on the Point Constructor --> You see that the X, Y, Z coordinates of the point constructor are filled with values X = -107.00347638373 Y = -112.758254700623 Z = 181.777563696959 --> Press OK and OK again --> The part has been repaired. I have repaired the part in NX6 using the method described above and the part passes playback cleanly. The fixed part will be available on request, 4222-249-08520_Draft(84)_repairedNX6_UM.prt. ===============================================================================

1953176

Siemens PLM believes that the problem you reported where "Mpire bracket 2_Draft(184) fails in NX 8.5.2.3 MP1 on Playback" will be resolved by code changes made to the upcoming release of our software NX 10.

Additional information: ------------------------ The root cause of the problem is the Stationary reference input, Datum plane, to the Draft(184) is missing. Most likely it would have been deleted. From NX 10 onwards these type of features, in which their Stationary plane is deleted, will also update without any problem. For technical reasons this fix can't be made available in NX 8.5 and NX 9. The repaired part (NX 6) will be send to customer.

1953473

The problem where the clone failed with error: Teamcenter Error: 9069 and ERROR: (920007)is fixed in release NX 10.

1953550

Siemens PLM believes that the problem you reported where Cannot create Parallel Dimension. If the view style is exact (pre NX 8.5) will be resolved by code changes made to the upcoming release of our software NX 10.

1953606

Siemens PLM believes that the problem you reported monolithic JT files will be resolved by code changes made to the upcoming release of our software. The problem where monolithic jt files are imported as legacy NX Facets rather than JT Facets is fixed in NX 10.

1953730

Siemens PLM believes that the problem you reported where NX does not recognize arrow heads and do no fill them out will be resolved by code changes made to the upcoming release of our software. The problem where NX does not recognize arrow heads and do not fill them out is fixed in release NX 10.

1953796

Siemens PLM believes that the problem you reported where there is an error - An Operation was attempted on an invalid or unsuitable OM object will be resolved by code changes made to the upcoming release of our software NX 10.

1953844

Siemens PLM believes that the problem you reported that Font Family fonts are not fully supported is missing in the documentation will be resolved by code changes made to the release of our product. The problem where it is not documented that NX does not support Arial Narrow fonts is fixed in NX 10. The Drafting Help already includes the following statement: "Although the FreeType Font library supports non scaleable and other font types, only salable TrueType, OpenType, and PostScript fonts are supported." The following sentences was added to this statement: "For example, the Arial narrow font style is not supported."

1953922

Siemens PLM believes that the problem you reported with a BOM List Problem with Electrical routing formboard will be resolved by code changes made to the upcoming release of our software NX 10.

1953954

Siemens PLM believes that the problem you reported where UFUi.SelectWithClassDialog throws Invocation Exception in Remote mode will be resolved by code changes made to the upcoming release of our software NX 10. The documentation will be extended to state "Callbacks in remoting mode are not supported in .Net".

1953970

Siemens PLM believes that the problem you reported where you were unable to add the Clear Rotation Reference command to the view shortcut menu will be resolved by code changes made to the upcoming release of our software V10.

1954017

Siemens PLM believes that the problem that you reported where the action of exporting a subset of an fea model to abaqus can take an unreasonable length of time and which may also result in erroneous entries in the abaqus input deck will be resolved by code changes made to the upcoming release of our software NX 10.

1954040

Siemens PLM believes that the problem you reported where the Weld Fillet would not rebuild and results in retained feature will be resolved by code changes made to the upcoming release of our software NX 10.

1954398

Siemens PLM believes that the problem you reported where (PS v27.0) Difference of behaviour between Face Blend and Edge Blend will be resolved by code changes made to the upcoming release of our software NX 10.

1954423

Siemens PLM believes that the problem you reported where "Couldn't refile non-master - Unable to process entry" will be resolved by code changes made to the upcoming release of our software NX 10.

1954545

Siemens PLM believes that the problem you reported where LENGTH_ADDITION and LENGTH_COEFFIECIENT are not applicable in Routing Mech will be resolved by code changes made to the release of our product NX version 10. The information has now been moved to the appropriate section of the help documentation.

1954593

PS27.0.50::Bodydraft doesn't work for Revolve Angle from 180 to 360.

1954699

Siemens PLM believes that the problem you reported where a wrong reversed Section Surface is created that does not match the preview will be resolved by code changes made to the upcoming release of our software NX 10.

1954712

Siemens PLM believes that the problem you reported where Different result at Angular Dimension (synch Mod) between NX 7.5 and NX 8 /8.5 will be resolved by code changes made to the upcoming release of our software NX 10.

1954880

Siemens PLM believes that the problem you reported where "Move object > Distance Between Points --> message: no motion has been specified" will be resolved by changes in the Documentation, made to the upcoming release of our software NX 10.. The Modeling Help for the Move Object, Distance Between Points option, has been rewritten to the following: Distance between Points - A linear distance derived from an origin point and a reference measurement point. When you specify the origin and measurement points and the vector, the current distance between the points appears in the Distance box. You can then specify a new value in the Distance box to move the object along the vector to a new relative location.

1954900

Siemens PLM believes that the problem you reported where Opening SolidWorks assembly returns The PLM XML document failed to load will be resolved by code changes made to the upcoming release of our software NX 10.

1955329

Siemens PLM believes that the problem you reported where mqc_check3DModel does not check for sheet bodies in the part will be resolved by code changes made to the upcoming release of our software NX 10.

1955489

Siemens PLM believes that the problem you reported where Stock is not displayed for terminal port wires and cable not cut back as per NX7.5 will be resolved by code changes made to the upcoming release of our software NX 10.

1955550

Siemens PLM believes that the problem you reported where you can't edit the sketch 1 in attached file due to the big size, will be resolved by code changes made to the upcoming release of our software NX 10. The problem where the system stack is filled up during update due to a very large amount of objects being managed has been fixed in release NX 10.

1955572

Siemens PLM believes that the problem you reported where PDF export asks if you wish to replace existing file twice will be resolved by code changes made to the upcoming release of our software NX 10.

1955851

The problem where Edit Fillet un-parametrizes a linked composite curve is fixed in NX 10.

1955893

Siemens PLM believes that the problem you reported where the drop type "After" is never passed to onDropCallback() will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10.

1956032

Siemens PLM believes that the problem you reported where Updating parent view hides Detail View Label if Delay View Update is turned off will be resolved by code changes made to the upcoming release of our software. This is fixed in NX 9.0.3 and NX 10.

1956033

Siemens PLM believes that the problem you reported where text justification/alignment in Weld Symbols cannot be edited will be resolved by code changes made to the upcoming release of our software NX 10.

1956238

Siemens PLM believes that the problem you reported where a KF class ug_motion_result failure causes not recoverable ADAMS motion error will be resolved by code changes made to the upcoming release of our software NX 10.

1956438

Siemens PLM believes that the problem you reported where "Not possible to create pattern of a Trim-Feature" will be resolved by code changes made to the upcoming release of our software NX 10.

1956444

Siemens PLM believes that the problem you reported where the Open C API function UF_OBJ_set_color() throws an Internal Error when called from a registered UF_open_part_reason callback will be resolved by code changes made to the upcoming release of our software NX 10. An error message will now be displayed stating that a work part must be present.

1956543

Siemens PLM believes that the problem you reported where "The number of sheets changes automatically when you use the Orient View Tool" will be resolved by code changes made to the upcoming release of our software NX 10.

1956599

Siemens PLM believes that the problem you reported where 2D local remesh create degenerated CQUAD4 elements will be resolved by code changes made to the upcoming release of our software NX 10.

1956713

Siemens PLM believes that the problem you reported where loading parts causes Incorrect object for this operation exception to be raised is due to corrupt parts. NX code has been made tolerant of these kind of corruptions will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10.

1956733

Siemens PLM believes that the problem you reported where the documentation about Mitered Bend type corner gives wrong impression will be resolved by changes made to the documentation in the upcoming release of our software NX 10.

1957252

Siemens PLM believes that the problem you reported where DOC: FBM Information is not guilty in NX 8.5 (was in NX6) will be resolved by code changes made to the upcoming release of our software NX 10.

1957288

Siemens PLM believes that the problem you reported where Define Custom Symbol dialog does not work when a LOV is attached to object_name will be resolved by code changes made to the upcoming release of our software NX 10.

1957362

Siemens PLM believes that the problem you reported where Change of DB_PART_NO / item_id requires restart of NX, will be resolved by code changes made to the upcoming release of our software NX V10.

1957848

Siemens PLM believes that the problem you reported where "Poor Performance in NX Advanced Simulation with Models that have Many Holes" will be resolved by code changes made to the release of our product NX 10.

1957857

Siemens PLM believes that the problem you reported where "Poor Performance in NX Advanced Simulation with Models that have Many Holes" will be resolved by code changes made to the release of our product NX version 10.

1957976

Siemens PLM believes that the problem you reported where Material Library Manager - displayed columns revert back to default settings when you leave the menu will be resolved by code changes made to the release of our software NX 10.

1957998

Siemens PLM believes that the problem you reported where rbe3 'glue non-coincident' mesh mating conditions which were previously moved to one mesh collector are re-assigned to unique mesh collectors when an 'update finite element model' action is performed will be resolved by code changes made to the upcoming release of our software NX 10.

1958047

Siemens PLM believes that the problem you reported where the 'global contact parameters' functionality is missing from the 'case control' tab within a 'sol 105 - linear buckling' solution will be resolved by code changes made to the upcoming release of our software NX 10.

1958135

Siemens PLM believes that the problem you reported where Transform Path results in error - A tag was passed belonging to an object that could not be found, will be resolved by code changes made to the upcoming release of our software NX 10.

1958362

Siemens PLM believes that the problem you reported parts for wrong Attribute Notes value will be resolved by code changes made to the upcoming release of our software. The problem where in some cases, references by annotations to PDM-based attributes have gone awry has been fixed in release NX 0. The fix is also back-ported to previous releases. Loading the part in question, running the part fixup (no selections needed) and saving the part should fix the references.

1958378

Siemens PLM believes that the problem you reported where Thread representation in assemblies will be resolved by code changes made to the release of our product NX version 10. The problem where Symbolic Thread Curve from components not getting clipped is fixed in NX 10 IP 20. Symbolic Thread from the component will be clipped only if the body referenced by this thread is selected for clipping. To know body referenced by symbolic thread corresponding component needs to be fully loaded. So note that component corresponding to symbolic thread needs to be fully loaded to see threads clipped.

1958492

Siemens PLM believes that the problem you reported where stock is not displayed correctly after applying Miter Corner will be resolved by code changes made to the upcoming release of our software NX 10.

1958529

Siemens PLM believes that the problem you reported where Moldwizard cannot change parameters of moldbase components in next session will be resolved by code changes made to the upcoming release of our software NX 10. The fix is also submitted to NX 9.0.2 MP1.

1958694

Siemens PLM believes that the problem you reported a case where it isn't possible to Delete a Spline in Sketch will be resolved by code changes made to the upcoming release of our software. The problem where user is unable to delete spline in sketch is fixed in release NX 10.

1958753

Siemens PLM believes that the problem you reported where nx crash when open component fully on a assemble will be resolved by code changes made to the upcoming release of our software. The problem where in some cases, references by annotations to PDM-based attributes have gone away has been fixed in release NX 10. The fix is also back-ported to previous releases. Loading the part in question, running the part fixup (no selections needed) and saving the part should fix the references.

1958817

Siemens PLM believes that the problem you reported where an imported drawing template does not display the drawing border, will be resolved by code changes made to the upcoming release of our software NX 10.

1958868

Siemens PLM believes that the problem you reported where Toolpath generate returns in an O/S Error and Customer cannot save the Part (2GB range) will be resolved by code changes made to the release of our product NX 10.

1958930

Siemens PLM believes that the problem you reported where the UI preferences dialog is showing complete journal support but the journaling is not capturing the windows style changes will be resolved by code changes made to the upcoming release of our software NX 10.

1959247

Siemens PLM believes that the problem you reported where the simple measure dialog is not correct will be resolved by code changes made to the upcoming release of our software NX 10.

1959388

Siemens PLM believes that the problem you reported where Reference Set defined in PTB file no longer used during place part will be resolved by code changes made to the upcoming release of our software NX 10.

1959399

Siemens PLM believes that the problem you reported where Floe_Best-Replace Face 121.prt fails in NX 8.5.2 MP2 playback will be resolved by code changes made to the upcoming release of our software NX 10.

1959460

Siemens PLM believes that the problem you reported where stress, strain and creep strain results data (for CPLSTS8 elements) output from a SOL 601 analysis cannot be post-processed by NX will be resolved by code changes made to the upcoming release of our software NX 10.

1959509

Siemens PLM believes that the problem that you reported where an error of the form: 'physical property plsolid1 has no assigned material' is issued at export when more than one mesh with a 'mathp - simple' material definition reference the same physical property, will be resolved by code changes made to the upcoming release of our software NX 10.

1959558

Siemens PLM believes that the problem you reported where rebend failed if SM part is huge will be resolved by code changes made to the upcoming release of our software NX 10.

1959835

Siemens PLM believes that the problem you reported where importing a new 'condition sequence' (.bdd file) where one of the previously defined parameters is missing from the .bdd file causes the subsequent analysis to fail (note that the parameter is still present within nx but has no value), will be resolved by code changes made to the release of our product NX 10.

1959880

Siemens PLM believes that the problem you reported where associative translated weld points do not update the local CSYS after a change will be resolved by code changes made to the upcoming release of our software NX 10.Prior releases had no associativity by design. NX 10.0 will be ready for customer download from 23-Dec-2014.

1960018

Siemens PLM believes that the problem you reported where the NXOpen method NXObject.DeleteUserAttribute() doesn't delete attribute array member without an existing attribute template will be resolved by code changes made to the upcoming release of our software NX 10.

1960045

Siemens PLM believes that the problem you reported where the documentation for NXObject::DeleteUserAttribute is unclear will be resolved by code changes made to the upcoming release of our software NX 10.

1960345

Siemens PLM believes that the problem you reported where the displayed color of a facet body is different to the info object color will be resolved by code changes made to the upcoming release of our software NX 10. The problem where The displayed color of a facet body is different to the info object color is due the fact that provided jt is a monolithic jt file and is fixed in NX 10 IP3 NX 10 has enhancements that imports such jt files as LW bodies instead of NX Facet bodies. Jt facets provide sectioning with much richer information.

1960373

Siemens PLM believes that the problem you reported where Unable to import assemblies using clone-based TC import will be resolved by code changes made to the upcoming release of our software NX 10.This version will be ready for customer download from 23-Dec-2014.

1960579

Siemens PLM believes that the problem you reported where Error : No gravity in model will be resolved by code changes made to the upcoming release of our software NX 10.

1960711

Siemens PLM believes that the problem you reported where "Stacked attributes values don't update" will be resolved by code changes made to the upcoming release of our software NX 10.

1961305

Siemens PLM believes that the routing problem you reported where "Work part has not been converted" will be resolved by code changes made to the upcoming release of our software NX 10.

1961375

Siemens PLM believes that the problem you reported where routing curve points show invalid constraints using on curve snap will be resolved by code changes made to the upcoming release of our software NX 10.

1961386

Siemens PLM believes that the problem you reported where the user is unable to save part when part name violates naming rule will be resolved by code changes made to the upcoming release of our software NX 10.

1961537

Siemens PLM believes that the problem you reported where BaseData Loadings defined by absolute values are modified will be resolved by code changes made to the upcoming release of our software NX 8.5.2MP1, NX and in NX 10.

1961652

Siemens PLM believes that the problem you reported where intersection tool gives alert when one body is inside the other will be resolved by code changes made to the upcoming release of our software NX 10.

1961948

Siemens PLM believes that the problem you reported where "Feature to be reordered is being referenced" and "parts with features applied to stock features" will be resolved by code changes made to the upcoming release of our software NX 10, NX 9.0.1 and MPs to NX 8.5.3 and NX 8.5.2.

1961972

Siemens PLM believes that the problem you reported where UF_MODL_ask_bounding_box_aligned loop fails with "Tag limit would be exceeded" will be resolved by code changes made to the upcoming release of our software NX 10.5

1962104

Siemens PLM believes that the problem you reported where "some 1D element results are not color contoured" will be resolved by code changes made to the upcoming release of our software NX 10.

1962349

Siemens PLM believes that the problem you reported where an Assembly cannot be loaded in NX 8.5.3 anymore will be resolved by code changes made to the upcoming release of our software. The problem opening parts with features applied to stock features has been fixed in NX 10, NX 9.0.1 and MPs to NX 8.5.3 and NX 8.5.2.

1962404

Siemens PLM believes that the problem you reported where Inserting surface finish symbol takes a very long time when parts list is placed will be resolved by code changes made to the upcoming release of our software NX 10.

1962547

Siemens PLM believes that the problem you reported where the Open C API UF_TEXT_load_translation_file() fails with error code 1 subsequently will be resolved by code changes made to the upcoming release of our software NX 10. It will now return an error UF_err_already_loaded.

1962630

Siemens PLM believes that the problem you reported where "objects are missing in vrml file" will be resolved by code changes made to the upcoming release of our software NX 10. The fix will also be submitted to NX 9.0.1.

1962638

Siemens PLM believes that the problem you reported where there was an error in Expression Name during Creation of a symbolic thread with manual input will be resolved by code changes made to the upcoming release of our software NX 10.

1962746

Siemens PLM believes that the problem you reported where New Pattern Feature: Can't pattern a TrimBody Feature will be resolved by code changes made to the upcoming release of our software NX 10.

1962824

Siemens PLM believes that the problem you reported where the help for the Standard Part Management dialog box didn't show up in the help collection will be resolved by code changes made to the upcoming release of our software NX 10.

1962826

Siemens PLM believes that the problem you reported where Poor documentation of Material Mapping will be resolved by changes made to the documentation of our product NX version 10.

1962832

Siemens PLM believes that the problem you reported where JT without BREP and MONOLITHIC doesn't create measurable bodies will be resolved by code changes made to the upcoming release of our software. The problem where importing monolithic jt without brep creates NX facets instead of Jt Facets is fixed in NX 10.

1962893

The request for additional information in the Assemblies Help about the Component Properties options in the Replace Component dialog box is fixed in release NX 10. This version is planned to be ready for customer download from 23-Dec-2014.

1962942

The problem where the Assemblies Help needed additional information about how component name changes via the name options in the Component Properties dialog box are considered overrides, which are therefore applied to replacement components as well, is fixed in NX 10.

1962947

The problem where the Assemblies Help needed additional information about how component name changes via the name options in the Component Properties dialog box are considered overrides, which are therefore applied to replacement components as well, is fixed in NX 10.

1963051

Siemens PLM believes that the problem you reported where in a part specific situation incorrect offset midsurface is generated will be resolved by code changes made to the release of our product NX 10.

1963148

Siemens PLM believes that the problem you reported where Tube function output "Single Segment" creates incorrect tangential point will be resolved by code changes made to the upcoming release of our software NX 10. The Tube feature has been enhanced to produce better output for tangent curves for "single segment" output option. The swept surface of the Tube will terminate at the end of each discrete curve in the tangent-continuous path. Tube features created in NX 10 and later will have the new behavior; NX 9 and older features will continue to maintain their output geometry.

1963172

Siemens PLM believes that the problem you reported where "The Model Setup Check warning regarding an LBC being applied to unmeshed or partially meshed geometry is not properly issued for NASTRAN SOL 106 solutions" will be resolved by code changes made to the upcoming release of our software NX 10.

1963360

Siemens PLM believes that the problem you reported where Qualify Part, Port Characteristics problem with the "Reference" Option was validated against NX 10.0 and it was found to be resolved.

1963372

Siemens PLM believes that the problem you reported where simulation results could not be queried due to an internal error will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10.

1963897

Siemens PLM believes that the problem you reported where "streamlines are not correctly displayed in a specific model" will be resolved by code changes made to the upcoming release of our software NX 10.

1963969

Siemens PLM believes that the problem you reported where in NX9 - BC Plot Contours - Zero value - Alert - "There are no values to Display" will be resolved by code changes made to the upcoming release of our software NX 10.

1964037

Siemens PLM believes that the problem you reported where Special German Character like "ä" does not work for customized CAM-Template will be resolved by code changes made to the release of our product NX 10.

1964187

Siemens PLM believes that the problem you reported where "Hole Positioning dimensions displayed on wrong location" will be resolved by code changes made to the upcoming release of our software NX 10.

1964410

Siemens PLM believes that the problem you reported where CA_Quantity A/R if you create Component array with db_unit attribute will be resolved by code changes made to the upcoming release of our software NX 10.

1964487

Siemens PLM believes that the problem you reported where Feature Playback error in NX 9 will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014.

1964499

Siemens PLM believes that the problem you reported about Feature Playback error in NX9 will be resolved by code changes made to the upcoming release of our software NX 10.

1964850

Siemens PLM believes that the problem you reported where Groove_OD ignores stop position point while profiling will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10.

1964971

Siemens PLM believes that the problem you reported where UF_EVALSF_evaluate() returns incorrect points with X-form B-surface will be resolved by code changes made to the upcoming release of our software NX 10.

1965071

Siemens PLM believes that the problem you reported where adding the Electrical "Routing_BOM_metric" table raised: "An operation was attempted on an invalid or unsuitable OM object", will be resolved by code changes made to the release of our product NX 10.

1965219

Siemens PLM believes that the problem you reported where "Assembly part fails to load in NX 8.5.3.3" will be resolved by code changes made to the upcoming release of our software NX 10.

1965234

Siemens PLM believes that the problem you reported with a problem of dxfdwg.exe will be resolved by code changes made to the upcoming release of our software. The problem where translator fails during export to dxf is resolved. The fix is available in NX 10.

1965281

Siemens PLM believes that the problem you reported where when using the 'copy & paste' function on the laminates 'layup modeler' form to create new plies, the numbering of the plies is reversed so that they are no longer sequential when the 'paste repetition' option is set to '2' or greater, will be resolved by code changes made to the upcoming release of our software NX 10.

1965317

Siemens PLM believes that the problem you reported where Maximum Velocity and Maximum Degrees per Minute were not documented in the Edit Axis dialog box will be resolved by code changes made to the upcoming release of our software NX 10.

1965326

Siemens PLM believes that the problem you reported where View Break update failed - dimensions are invisible will be resolved by code changes made to the upcoming release of our software NX 10.

1965349

Siemens PLM believes that the problem you reported where Weld Point:It is not possible to change Guide curve parameter using multiple Ref will be resolved by code changes made to the upcoming release of our software. The problem of being able to change parameters of guide curves for multiple overlap sheets is fixed in the NX 10 Weld Point Wizard.

1965477

Siemens PLM believes that the problem you reported where "Incorrect Annotation Sketch Display for Variational Sweep " will be resolved by code changes made to the upcoming release of our software NX 10.

1965769

Siemens PLM believes that the problem you reported regarding Checker issues with Check Single Part Attribute / Check Multiple Part Attributes will be resolved by code changes made to the upcoming release of our software NX 10. The "issue1" in this PR is fixed in NX 10. The checker document in mqc_check_single_part_attr.dfa now indicates that the format of mapping rule MATCH_ONE_IN_SET should be a string of attribute values, separated by semicolons, for example, "MLDES; MLASM; LYTFMT". Regarding to "issue2", the user should customize the "attr_titles_MatchMethod_MatchParam_init" attribute instead of "attr_titles_MatchMethod_MatchParam" attribute in a customized "Check Multiple Part Attributes" checker dfa file. The list type parameter adds a list window dialog item in the customization dialog, which does not allow any text input. The user can only select the listed items which are pre-specified by the "attr_titles_MatchMethod_MatchParam_init" attribute. The user can follow the steps described in the checker document to customize the checker template.

1965794

Siemens PLM believes that the problem you reported where Change of DB_PART_NO / item_id required restart of NX will be resolved by code changes made to the upcoming release of our software NX 10.

1965892

Siemens PLM believes that the problem you reported where DB_Part_Name and DB_Part_Desc cannot be edited from the part family table will be resolved by code changes made to the upcoming release of our software NX 10.

1965920

Siemens PLM believes that the problem you reported where UGTO2D.exe '-r' option needed adding to help documentation will be resolved by code changes made to the upcoming release of our software NX 10.

1966072

Siemens PLM believes that the problem you reported where there is an incorrect reference to Assembly Navigator Toolbar in NX documentation will be resolved by code changes made to the upcoming release of our software NX 10.0

1966387

Siemens PLM believes that the problem you reported where 3D-Mesh creation changes 2D reference-mesh will be resolved by code changes made to the upcoming release of our software NX 10.

1966573

The problem where the existing information regarding the Import and Export Expressions was not correct is fixed in NX 10.0 Help documentation. Added the information that the Import and Export Expressions command works for the user-defined expressions.

1966774

Siemens PLM believes that the problem you reported where External NC-code file simulation with default MCP causes exception (VNCK) will be resolved by code changes made to the upcoming release of our software NX 9.0.2 ; NX 10

1967088

Siemens PLM believes that the problem you reported where Invalid values found in stress-strain data table for material "Test material" will be resolved by code changes made to the upcoming release of our software NX 10.

1967100

Siemens PLM believes that the problem you reported where Measure Projected distance displays different results in information window will be resolved by code changes made to the upcoming release of our software NX 10.

1967173

Siemens PLM believes that the problem you reported with the empty CollisionPairBuilderList from new CollisionConfigurationBuilder will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10.

1967249

Siemens PLM believes that the problem you reported where about "Problem with FEM's groups and SIM's groups in postprocessing" will be resolved by code changes made to the upcoming release of our software NX 10.

1967288

Siemens PLM believes that the problem you reported "Mechanical Load summary returns null values for Pressure LOAD (components option)" will be resolved by code changes made to the upcoming release of our software NX 10.

1967415

Siemens PLM believes that the problem you reported where "Internal Error Memory access violation appears" will be resolved by code changes made to the release of our product NX 10.

1967465

Siemens PLM believes that the problem you reported where wrong Hinge direction on creation Section view with moving sections arrows will be resolved by code changes made to the upcoming release of our Software NX 10.

1967665

Siemens PLM believes that the problem you reported where "too big difference of weight when mirror body" has been fixed in Parasolid. It will be resolved by code changes made to the upcoming release of our software NX 10.

1967669

Siemens PLM believes that the problem you reported where adding a detail view leads to an error during update will be resolved by code changes made to the upcoming release of our software NX 10.

1967747

Siemens PLM believes that the problem you reported where Bead over bend produces not tangent faces will be resolved by code changes made to the upcoming release of our software NX 10.

1967813

Siemens PLM believes that the problem you reported where "save All from the sim file does not save the fem file but only the sim file" will be resolved by code changes made to the upcoming release of our software NX 10.

1967838

Siemens PLM believes that the problem you reported where: You Can't select positioning dimensions without clicking icon twice will be resolved by code changes made to the release of our software NX 10.

1967870

Siemens PLM believes that the problem you reported where the NXOpen property 'AttributePropertiesBaseBuilder.ObjectPicker' should be marked as deprecated will be resolved by code changes made to the upcoming release of our software NX 10. We deprecated the 'NXOpen.AttributePropertiesBaseBuilder.ObjectPicker' method as this can only set attributes on certain type of objects whereas the new method added doesn't have such limitation. User can use NXObject.GetUserAttributeSourceObjects to get the source objects.

1967944

Siemens PLM believes that the problem you reported where an embedded custom symbol with multiple text attributes is not displayed correctly, will be resolved by code changes made to the upcoming release of our software NX 10.

1967966

Siemens PLM believes that the problem you reported where Define Deformable Part menu missing after switching to Routing application will be resolved by code changes made to the upcoming release of our software NX 10.

1968046

Siemens PLM believes that the problem you reported where Pattern of trim body feature is not possible will be resolved by code changes made to the upcoming release of our software NX 10.

1968131

Siemens PLM believes that the problem you reported where NX routing does not read all values from bend radius tables will be resolved by code changes made to the release of our product NX version 10.0.

1968301

Siemens PLM believes that the problem that you reported where the 'menu, insert, mesh, mesh control, biasing on edge' settings are not honoured when applied to a '2d (free) mesh' will be resolved by code changes made to the upcoming release of our software NX 10.Note that these same settings are honoured if applied to a '2d mapped mesh', which might provide a work-around in some scenarios.

1968521

Siemens PLM believes that the problem you reported with a wrong measurement result between components will be resolved by code changes made to the upcoming release of our software. The problem with different values between the facet measurement and the solid geometry measurement has been addressed in NX 10.

1968538

The problem where view dependent edits vanish when "Hidden Line" option is set to Invisible is fixed in NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them. A new procedure entitled "Display only view dependently edited hidden lines" is added to the Drafting Help that documents the process.

1968917

The issue where the Model Setup Check erroneously issued a warning about mass elements and gravity/centrifugal loads has been resolved in NX 10.

1968995

Siemens PLM believes that the problem you reported where Versioning Rules as described in NX help documentation do not work will be resolved by code changes made to the upcoming release of our software NX 10.The documentation has been corrected to show the correct versioning rules.

1969088

Changing the reference set with the toolbar does not un-select component.

1969191

Siemens PLM believes that the problem you reported where "Weld point: Hidden links cannot be deleted" will be resolved by code changes made to the upcoming release of our software NX 10. The problem of Hidden linked created by the Weld Point command has been resolved. In NX 10 the Weld Point command has been replaced by the Weld Point Wizard. Linked faces can now be found if they still exist after edit.

1969484

Siemens PLM believes that the problem you reported where Information Object shows density 0.13mm in NX 8.5.3 and Thin in NX 8.5.2 will be resolved by code changes made to the release of our product NX version 10. This fix is backported in following MPs: NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP.

1969640

Siemens PLM believes that the problem you reported where shaft tolerance values for the Fits and Limits are not updated will be resolved by code changes made to the upcoming release of our software NX 10.

1969727

Siemens PLM believes that the problem you reported where UF_DRF_create_label causes an Internal Error will be resolved by code changes made to the upcoming release of our software. Given program creates label with UF_DRF_leader_attach_object leader attachment type and specifying NULL_TAG for leader terminator. If NULL_TAG is specified for assoc object then it means leader is created at screen position. For such case UF_DRF_leader_attach_screen type should be used as UF_DRF_leader_attach_type_t. Same thing needs to be modified in user program to fix this issue. Updated documentation of method UF_DRF_create_label to include above case. This will be fixed in NX 10.

1969762

Siemens PLM believes that the problem you reported where MB3 on treelist item displays incorrect context menu will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014.

1969936

Siemens PLM believes that the problem you reported where Help on context doesn't work if UGII_DISABLE_HELP_PAGE=0, will be resolved by code changes made to the upcoming release of our software NX 10. Actually the fix is to not support this env variable and always open help pages on external browser.

1969982

The problem where Context Sensitive Help didn't work on the Pattern Component dialog box is fixed in release NX 10.

1969994

Siemens PLM believes that the problem you reported where Thread lines wrong displayed in Revolved Section View will be resolved by code changes made to the release of our product NX 10. The problem where drafting thread curves are missing a transform and therefore incorrectly displayed in new exact, revolved section views is fixed in NX 10.

1970126

Siemens PLM believes that the problem you reported where Formboard Drawing loses all Path Length Annotations after update will be resolved by code changes made to the upcoming release of our software NX 10.

1970200

Siemens PLM believes that the problem you reported where an abaqus 'bolt pre-load constraint' boundary condition is incorrectly exported to the abaqus .inp file if it has been defined on more than one element will be resolved by code changes made to the upcoming release of our software NX 10.

1970202

Siemens PLM believes that the problem you reported where Checkmate Bodies Consistency crash will be resolved by code changes made to the upcoming release of our software NX 10 and later.

1970244

Siemens PLM believes that the problem you reported where 'the dimension text would flip for angular dimension in some cases', has been fixed in NX 10. This issue occurred when text was centered and auto placement was off will be resolved by code changes made to the upcoming release of our software NX 10.

1970391

Siemens PLM believes that the problem you reported where there is an error- A dimension subscript for an array attribute was out of range or invalid will be resolved by code changes made to the upcoming release of our software NX 10.

1970470

Siemens PLM believes that the problem you reported where the mechanical load summary of hydrostatic load doesn't agree with Nastran OLOAD will be resolved by code changes made to the release of our product. A fix for the unit conversion problem has been submitted to NX 10.

1970780

Siemens PLM believes that the problem you reported where wrong Hinge direction on creation Section view with moving sections arrows will be resolved by code changes made to the upcoming release of our software NX 10.

1971069

Siemens PLM believes that the problem you reported where Export to Geo file fails with invalid curve topology will be resolved by code changes made to the upcoming release of our software NX 10.

1971127

Siemens PLM believes that the problem you reported where Unable to open part - A deleted or invalid class id was used will be resolved by code changes made to the upcoming release of our software NX 10.As requested, the given part has been fixed and provided to the customer as file "334_J1472_A_fixed.prt". Furthermore, a robustness fix will be put into NX 10 to allow the originally corrupt part to be open in NX 10 and future NX versions.

1971148

Siemens PLM believes that the problem you reported where after Divide Face->Draft creates error when using 2 sets in different directions will be resolved by code changes made to the upcoming release of our software NX 10.

1971198

Siemens PLM believes that the problem you reported where Non-associative mirror body is inconsistently associative for the threads will be resolved by code changes made to the upcoming release of our software NX 10.

1971211

Siemens PLM believes that the problem you reported where a Datum CSYS cannot be selected in assembly level (E.g.: Move to Layer, Hide, ...) will be resolved by code changes made to the upcoming release of our software NX 10.

1971401

Siemens PLM believes that the problem you reported where the problem with updating sketch in NX8.5 will be resolved by code changes made to the upcoming release of our software NX 10. The vertical dimension "p95=DFH_SPL*.1" in Sketch GUCGEC_001:Contour Screw has some of its data missing. If you delete and re-create this dimension, the part will get fixed. We have made code change to cope with this bad data in NX 10 (phase 12). The dimension will now get fixed when you open the part in NX 10. The WA for earlier releases is to re-create this dimension.

1971441

Siemens PLM believes that the problem you reported where Error with special characters in file and folder of NX Open BlockStyler will be resolved by code changes made to the upcoming release of our software NX 10.

1971589

Siemens PLM believes that the problem you reported where Scope of delayed update customer default gives different results in NX8 onwards is fixed in patches NX 8.5.3 MP4 and NX 9.0.1 MP2 along with NX 10.

1971693

Siemens PLM believes that the problem you reported where Adding part to assembly, part disappears from preview window during constraining will be resolved by code changes made to the upcoming release of our software NX 10.

1971837

Siemens PLM believes that the problem you reported where "ug_import from custom Item with mapped material attribute results in error" will be resolved by code changes made to the upcoming release of our software NX 10

1971845

Siemens PLM believes that the problem you reported where NX SheetMetal Bead Function not work clean will be resolved by code changes made to the upcoming release of our software NX 10.

1971854

Siemens PLM believes that the problem you reported where the command 'File -> Plot -> Color and Width -> Custom Widths -> Define Widths -> Open WDF' and the OpenC method UF_PLOT_read_custom_widths_from_wdf() does not read back the value correctly for the twelfth width entry will be resolved by code changes made to the upcoming release of our software NX 10.

1971981

Siemens PLM believes that the problem you reported where Stock is not displayed correctly after applying Miter Corner will be resolved by code changes made to the upcoming release of our software NX 10.Miter corner will generate correct result.

1971985

Siemens PLM believes that the problem you reported with the Wrong Display of a section in the Profile and destruction of Path will be resolved by code changes made to the upcoming release of our software V10.0.

1972046

Siemens PLM believes that the problem you reported where a Boolean fails will be resolved by code changes made to the upcoming release of our software NX 10.

1972084

Siemens PLM believes that the problem you reported where mirror feature doesn't mirror all blend edges will be resolved by code changes made to the upcoming release of our software NX 10.

1972402

Siemens PLM believes that the problem you reported where Formboard Orient Branch gives incorrect results will be resolved by code changes made to the upcoming release of our software NX 10.

1972461

Siemens PLM believes that the problem you reported where Save Failed will be resolved by code changes made to the upcoming release of our software NX 10.

1972491

Siemens PLM believes that the problem you reported where "NX9 CAE Post View and Excel spreadsheet generates an issue" will be resolved by code changes made to the release of our product NX 10.

1972594

Siemens PLM believes that the problem you reported where performance problem if "Part Name Style Attribute" is changed to object_string will be resolved by code changes made to the release of our software NX 10 the fix may also be back ported to the desired MPs of previous NX version as needed.

1972666

The problem where Sketch result wrong after mirroring the feature - NX 8.5.3 vs. NX 9.0.1 has been investigated and the following has been found. Stabilizing the two sketches in the part by adding an "Intermediate Datum CSYS" and "Project the Work Part Origin" has resolved the issue at hand! Please refer to the uploaded NX75_model_in_NX85_1-Fixed.prt as a workarond and the Reattach-Fix.avi the steps taken to apply the workarond! Download the file here: http://download.industrysoftware.automation.siemens.com/special.php/returned/cg -clean.92744-1.00uwm000_a_fixed_in_nx7554.prt.7z

1972668

Siemens PLM believes that the problem you reported where additional documentation is needed for the "Structure Update on Save" preference will be resolved by code changes made to the upcoming release of our software NX 10.

1972839

Siemens PLM believes that the problem you reported where the NXOpen method NXOpen::Die::DieCollection::CreateDrawBeadBuilder requires a 'ug_die_design' license will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3, NX 9.0.2, NX 10.

1972973

Siemens PLM believes that the problem you reported where NX hangs and crashes with 3D annotations on tets elements will be resolved by code changes made to the upcoming release of our software NX 10.

1973146

Siemens PLM believes that the problem you reported where the "Cannot split 2d shell element: attempt to write to freed object" message appear will be resolved by code changes made to the upcoming release of our software NX 10.

1973160

Siemens PLM believes that the problem you reported where Opening drawing loads objects on demand from master model will be resolved by code changes made to the release of our product NX 10.The part will now open properly but the user will need to perform a part cleanup once the part is opened.

1973190

The problem where text associated to an attribute in a Pattern is wrong when exported in DXF is fixed in release NX 10.0 for legacy text. The use of the component object name to resolve attributes is not robust since objects in NX do not have unique names. Customers should strongly consider the use of sheet templates. Sheet templates use a more robust technique to resolve master model attribute references instead of relying on object names which are not unique.

1973229

Siemens PLM believes that the problem you reported where non-circular edges can be selected for radius/diameter measurement, will be resolved by code changes made to the upcoming release of our software NX 10.

1973239

Siemens PLM believes that the problem you reported where applying a Pattern feature using Variational method moves faces will be resolved by code changes made to the upcoming release of our software NX 10.

1973298

Siemens PLM believes that the problem you reported where NXOpen.Features.FeatureCollection.GetAssociatedFeaturesOfEdge causes an Internal Error on specific edges will be resolved by code changes made to the upcoming release of our software NX 10.

1973304

Siemens PLM believes that the problem you reported where "Within Work Part Only" selection scope does not work when sketch is active will be resolved by code changes made to the upcoming release of our software NX 10.

1973375

Siemens PLM believes that the problem you reported will be resolved by code changes made to the upcoming release of our software. The problem where expression get hidden is fixed in release NX 10.

1973410

The problem you reported where One Step Formability does not work in NX Manager because of creating a new Item in background is necessary and there are no further Items in the current Naming Rule pattern available can not be fixed. The creation of the new Item in background is necessary and working as designed. The software was changed for NX 10 to give the user an error message in case that new FEM part cannot be created in background for mesh elements so that user may check whether he can really create any new part with his TC settings.

1973428

Siemens PLM believes that the problem you reported where a "fem file creation using prt takes 6 hours when High resolution polygon bodies ON" will be resolved by code changes made to the upcoming release of our software NX 10.

1973498

Siemens PLM believes that the problem you reported where modifying an Assembly Cut operation gives incorrect results (due to the reordering of assembly-level features), will be resolved by code changes made to the upcoming release of our software NX 10.

1973566

Siemens PLM believes that the problem you reported where "incorrect percental physical viscous damping in NX response when using CBUSH elements" will be resolved by code changes made to the upcoming release of our software NX 10.

 Notes: - If the user creates a new FE model in NX 10, there will be no issue. The user interface will show correct units. - If the FE model was created with previous versions of NX, the value of Rotational Viscous Damping is kept (no conversion), but the correct units will be shown in the user interface. Therefore, the user must make sure that the value is correct and corresponds to the new units (the exported deck in NX 10 may show different values than the deck created in NX 9 or prior), especially in case of formulas and Field Tables.

1973659

Siemens PLM believes that the problem you reported where "Arrow display with text results format not updating" will be resolved by code changes made to the upcoming release of our software NX 10.

1973816

Siemens PLM believes that the problem you reported where Reference Set not switching back will be resolved by code changes made to the upcoming release of our software NX 9.0.3.

1974020

Siemens PLM believes that the problem you reported where the Documentation of NXOpen.BlockStyler.SelectObject.AddFilter needs correction will be resolved by code changes made to the upcoming release of our software NX 10.

1974026

The problem where unchanged assembly with part family members is marked modified when a new part is created in same session is fixed in release NX 10.

1974203

Siemens PLM believes that the problem you reported where rectangle selecting components when doing Edit Explosion selects the entire assembly will be resolved by code changes made to the upcoming release of our software NX 10.

1974223

Siemens PLM believes that the problem you reported with NX Sheet Metal Bead dialog legend will be resolved by code changes made to the upcoming release of our software NX 10.

1974247

Siemens PLM believes that the problem you reported where "no Deviation Gauge between Facet Body and Faces/Sheet" will be resolved by code changes made to the upcoming release of our software NX 10.

1974274

Siemens PLM believes that the problem you reported where the dispatcher go in "TERMINAL" with an empty NX dataset will be resolved by code changes made to the upcoming release of our software Teamcenter 11.1

1974281

Siemens PLM believes that the problem you reported where Bead dialog box topic had description for Punch Radius will be resolved by code changes made to the upcoming release of our software NX 10.

1974290

Siemens PLM believes that the problem you reported where Error when using a formula to enter the mass of a 0D element will be resolved by code changes made to the upcoming release of our software NX 10.

1974324

Siemens PLM believes that the problem you reported where a different read result from JT files without BRep will be resolved by code changes made to the upcoming release of our software. In NX 10 the demo_new.jt file will be loaded into NX and produces a Lightweight body as expected. This was a project enhancement done for NX 10. The problem is that the demo_new.jt file is a MONOLITHIC Jt file, and it contains a JtInstance node at level 5 between the VisMetaDataNode and the VisPartNode. In Demo.jt there is not a JtInstance node there. So if the producer of the Jt file could remove the extra JtInstance node, the Jt file will also work in NX 9.

1974372

Siemens PLM believes that the problem you reported where Selection filter keeps resetting will be resolved by code changes made to the upcoming release of our software NX 10.

1974566

Siemens PLM believes that the problem you reported where Direct Model (JT) Dataset not removed or updated for NX empty part will be resolved by code changes made to the upcoming release of our software NX 10.

1974689

The original issue logged in this PR for the NASTRAN Exporter aborting when processing PLOAD4s has been resolved. Subsequent issues reported for missing beam section assignment and incorrect AFEM label resolution have also been resolved. All this was verified in NX 10.

1974692

Siemens PLM believes that the problem you reported where the button "Define Deformable Part" menu button disappears after switching to routing will be resolved by code changes made to the upcoming release of our software NX 10.

1974718

Siemens PLM believes that the problem you reported where Box All Selection for 3D element was not picking some internal elements/elemnode, will be resolved by code changes made to the upcoming release of our software NX 10.

1974876

Siemens PLM believes that the problem you reported where "NX UI hangs and NX exporter generates a wrong NX Nastran deck file" will be resolved by code changes made to the release of our product NX 10.

1974999

Siemens PLM believes that the problem you reported where "Show/Hide of JointMark-feature in feature groups" will be resolved by code changes made to the upcoming release of our software in NX 10.0 (in P10.0/phase 12).

1975014

Siemens PLM believes that the problem you reported where "Drafting issue - View update loop caused by dependent section views containing" will be resolved by code changes made to the upcoming release of our software NX 10.

1975068

Siemens PLM believes that the problem you reported where The number of sheets is not correct after using Orient View Tool will be resolved by code changes made to the upcoming release of our software NX 10.

1975136

Siemens PLM believes that the problem you reported where The number of sheets is not correct after adding a detail view will be resolved by code changes made to the upcoming release of our software NX 10.

1975445

Siemens PLM believes that the problem you reported where "Plot Thickness contour results are wrong at fillet location" will be resolved by code changes made to the upcoming release of our software NX 10.The slight difference in thickness can happen when computing thickness at nodes on boundary. To avoid this issue, in NX 10, we introduced additional option in "Mesh associated" where user can select thickness at element CG. Using this option, gave 10mm constant thickness on entire model.

1975481

Siemens PLM believes that the problem you reported where Layer of KSYS is changing automatically if feature replay is chosen will be resolved by code changes made to the upcoming release of our software NX 10.

1975591

Siemens PLM believes that the problem you reported where the vector block gives the wrong direction in some scenario when you change the work part after the dialog has already been activated will be resolved by code changes made to the upcoming release of our software NX 10.

1975612

Siemens PLM believes that the problem you reported where Performance - Edit Object Display in NX 8.5 bad will be resolved by code changes made to the upcoming release of our software NX 10.

1975736

Siemens PLM believes that the problem you reported where Internal error on delete/add component will be resolved by code changes made to the upcoming release of our software NX 10. The problem where "Internal error on delete/add component" is fixed in NX 10 phase 18. The part corruption was caused by failing to convert pre-NX3 sequence steps in part files to modern sequence steps. This corruption would have occurred because parts were partially loaded in a previous (post-NX 2) release and the sequences and sequence steps were unloaded and so not available for conversion. The part files could then be saved, and the opportunity to perform sequence step conversion was missed. This is now anticipated, and sequence steps are converted even if the last saved release was later than NX 2.

1975918

Siemens PLM believes that the problem you reported where turn finishing operations generated different tool paths in NX9 compared to former versions of NX will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 10. The fix is also submitted to NX 9.0.1 MP2. As agreed by product management and our customer, the desired behavior reproducing the Finish Turn operation tool paths in question is solely available for now when an environment variable has been defined. Its name is: UGII_TURN_DIRECT_ENGAGE_AND_RETRACT_ALSO_IF_CONTAINMENT_HAS_TRIM_PLANES_ONLY (only needs to be defined and does not require a specific value).

1976387

Siemens PLM believes that the problem you reported where Delete Face/Cap Face option cannot delete as in NX8.5 will be resolved by code changes made to the upcoming release of our software NX 10.

1976448

Siemens PLM believes that the problem you reported where "Undetected Collision in ZLevel 5-Axis" will be resolved by code changes made to the release of our product NX 10 and future MP release of NX 9.0.3.

1976453

Siemens PLM believes that the problem you reported where Thicken gives incorrect result for surface from degree 3 spline will be resolved by code changes made to the upcoming release of our software NX 10.

1976459

Siemens PLM believes that the problem you reported where Sketch constraints reports wrongly as blanked object in check mate checker will be resolved by code changes made to the upcoming release of our software NX 10. Please note that doing an invert will not show the constraints of an inactive sketch. The user must activate the sketch to unblank the constraints in them.

1976465

Siemens PLM believes that the problem you reported where the NXOpen::Builder::Destroy() description breaks off mid-sentence will be resolved by code changes made to the upcoming release of our software NX 10. The fixed comment is: Deletes the builder, and cleans up any objects created by the builder. This method should always be called when a builder has been committed or is no longer needed.

1976565

Siemens PLM believes that the problem you reported where the JT Doc isn't clear - what means "Awaiting info from SME"? will be resolved by code changes made to the upcoming release of our software. The specified problem is already fixed and the changes will appear in the NX 10 documentation.

1976583

Siemens PLM believes that the problem you reported where the JT Documentation style and fonts are not consistent will be resolved by code changes made to the upcoming release of our software. The problem where the formatting was not consistent is fixed in release NX 10. Intentionally retained the difference in font of inverted commas at some of the locations to differentiate between the text from code and normal text.

1976653

Siemens PLM believes that the problem you reported where the problem of "Resize Bend Angle" will be resolved by code changes made to the upcoming release of our software NX 10.

1976655

Siemens PLM believes that the problem you reported where "Resize Bend Angle" failed by different angle will be resolved by code changes made to the upcoming release of our software NX 10.

1976658

Siemens PLM believes that the problem you reported where Layer and Color detail selection filters do not work for Exact and Smart Lightweight views, will be resolved by code changes made to the upcoming releases of our software NX 9.0.3 and NX 10.

1976788

Siemens PLM believes that the problem you reported where Custom shortcut not working will be resolved by code changes made to the upcoming release of our software NX 10. This version will be available for customer download from 23-Dec-2014.

1977050

Siemens PLM believes that the problem you reported where Helix failed by value along spine will be resolved by code changes made to the upcoming release of our software NX 10. The original tolerances were too tight. We have enhanced our function in NX 10 to deal with it. But suggest the user to apply a reasonable tolerance in NX 8.5 or NX 9 as a workaround such as 0.001mm as distance tol and 0.1 degree as angle tol.

1977110

Siemens PLM believes that the problem you reported where Routing: Insert flange-flange connection moves first flange instead of second on will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3 + HF and MP5 and higher MPs and NX 10.

1977126

Siemens PLM believes that the problem you reported where Routing: Flange flange connection does not move second flange when path exists will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3 + HF and MP5 and higher MPs and NX 10

1977164

Siemens PLM believes that the problem you reported where Recording "Analyze Formability One Step" creates thousands of Journal code lines will be resolved by code changes made to the upcoming release of our software NX 10.

1977206

The problem where "Save As New Item Type" is not inherit the attributes has been investigated and the following has been found. When doing a SaveAs New Item Type, the new part will be in a different mapping context from the original one (due to its item type change), the Pdm-based attributes from the original part will not be inherited to the new part in this case. This is now the behavior started in NX 8. This is because in pre-NX 8, attributes are always treated as of "string" data type, but started in NX8, attributes are supported with their actual data type as defined in TC database, e.g. integer, string, double, .etc. As a result, attributes of the same title but from different mapping context can have different data types as their underlying mapping definitions are different. On the other hand, for SaveAs New Item or SaveAs New ItemRevision, the new part is still in the same mapping context as that of the original part, therefore, the PDM-based attributes can still be inherited in the new part. The problem where "Save As New Item Type" is not inherit the attributes is fixed in NX 10. This version will be available from 23-Dec-2014.

1977362

Siemens PLM believes that the problem you reported where the Customer default MW_EW_DISPLAY_RENAME_DIALOG is not honored for 'Copy Electrode' will be resolved by code changes made to the upcoming release of our software NX 10.

1977370

Siemens PLM believes that the problem you reported where solving a specific model which includes a 'pload4' pressure load applied to a number of polygon faces fails during the export of the nx Nastran .dat file with the following error written to the nx information window: ERROR : Global Exception caught by Export Export terminated because of error will be resolved by code changes made to the upcoming release of our software NX 10.

1977518

Siemens PLM believes that the problem you reported where wave links break to ug_component upon update will be resolved by code changes made to the upcoming release of our software NX 10. There are some KF classes that are not able to support Update For External Change. The class ug_component is one of them because they do not participate in UPDATE as do other NX objects. Code was added to disable this function for ug_component.

1977529

Siemens PLM believes that the problem you reported where an automatic stitch edge gives partial result: imprint done, but edges not stitched will be resolved by code changes made to the upcoming release of our software NX 10.

1977549

Siemens PLM believes that the problem you reported where "Deformed shape is impossible with Relative displacement in NX Post" will be resolved by code changes made to the upcoming release of our software NX 10.

1977665

Siemens PLM believes that the problem you reported where You Cannot save imported Parasolid assembly, will be resolved by code changes made to the upcoming release of our software NX 10.

1977693

Siemens PLM believes that the problem you reported where "View Break edit fails with Extracted Edges on" will be resolved by code changes made to the upcoming release of our software NX 10.

1977703

Siemens PLM believes that the problem you reported where "Relabelling nodes makes MPC having memory and conflict issue" will be resolved by code changes made to the upcoming release of our software NX 10.

1977711

Siemens PLM believes that the problem you reported where The display of the Orient Express axes are inconsistent when using 'Move Object' will be resolved by code changes made to the upcoming release of our software NX 10.

1977712

Siemens PLM believes that the problem you reported where Routing assemblies (with gaskets/bolts/nuts) created with NX6 show erroneous will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3 + HF and MP5 and higher MPs and NX 10.

1977737

Siemens PLM believes that the problem you reported where udos have no links to NX Routing connections will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3 + HF and MP5 and higher MPs and NX 10.

1977751

Siemens PLM believes that the problem you reported where "Long time to edit parameters in Volume Milling" will be resolved by code changes made to the release of our product NX version 10

1977944

Siemens PLM believes that the problem you reported where NX hangs during stitching edge to face will be resolved by code changes made to the upcoming release of our software NX 10.0

1978016

Siemens PLM believes that the problem you reported where an analysis of a model which includes a 'simple radiation to environment' boundary condition based upon the 'radiative ambient' temperature gives a different result from the same model analyzed with a 'simple radiation to environment' boundary condition based upon a 'specified' temperature will be resolved by code changes made to the upcoming release of our software NX 10.

1978053

Siemens PLM believes that the problem you reported where Opening drawing with partial loading enabled causes NX to crash will be resolved by code changes made to the upcoming release of our software NX 10.

1978089

Siemens PLM believes that the problem you reported where editing an annotation in a read-only part triggers "A tag was passed..." error will be resolved by code changes made to the upcoming release of our software NX 10.

1978139

Siemens PLM believes that the problem you reported where NX hang - poor performance in meshing or remeshing - no remeshing? will be resolved by code changes made to the upcoming release of our software NX 10.

1978142

Siemens PLM believes that the problem you reported where FE Nodes can't be picked with a Block Styler "Specify Point" block in NX 9 will be resolved by code changes made to the upcoming release of our software NX 10. As the PR text points out, in NX 9 the SpecifyPoint block now correctly identifies and enforces the selection scope. By default, the selection scope for the SpecifyPoint widget is Within Work Part Only. Since the FEM entities have been occurrenced into the Simulation, there are no prototype nodes in the Simulation. The proper scope for a Simulation in this scenario is to use Entire Assembly. The SpecifyPoint Block wrt to CAE parts was reworked in NX 10 to extend the selection scope when you now set the InterpartSelection toggle. After the fix, here is what the new vb code looks like in order to allow snapping to nodes: Line 53: Was Private point0 As NXOpen.BlockStyler.UIBlock Now Private point0 As NXOpen.BlockStyler.SpecifyPoint Line 236: Was point0 = CType(theDialog.TopBlock.FindBlock("point0"), NXOpen.BlockStyler. UIBlock) Now point0 = CType(theDialog.TopBlock.FindBlock("point0"), NXOpen.BlockStyler.SpecifyPoint) Added line 237: point0. InterpartSelectionAsString= " Associative and Non-associative Interpart Copy" It now works for the CAE selection of nodes.

1978191

Siemens PLM believes that the problem you reported where Null tag error in assembly drawing will be resolved by code changes made to the upcoming release of our software NX 10. The problem where an error occurs when displaying a drawing containing exact views with Wireframe Color Source set to From Face after deleting a component from the model has been fixed for NX 9.0.3 and NX 10.

1978229

Siemens PLM believes that the problem you reported where 2D Exchange exports DXF with wrong dimension placement will be resolved by code changes made to the upcoming release of our software NX 10.

1978288

Siemens PLM believes that the problem you reported where you can't get the text of embedded Custom Symbol in PMI Note using NX Open will be resolved by code changes made to the release of our product NX 10.A new NXOpen method NXOpen::Annotations::TextWithSymbolsBuilder::GetEmbeddedCustomSymbols() is provided in NX 10.0 to get the embedded custom symbols. See the NX Open documention for more details. The API can't be back ported to previous releases.

1978482

Siemens PLM believes that the problem you reported where a ugmanager_import has an ERROR while setting the Teamcenter names - aborting import will be resolved by code changes made to the upcoming release of our software is fixed in NX 10.

1978629

Siemens PLM believes that the problem you reported where "Multiple Routing Sweep is not working as expected" will be resolved by code changes made to the release of our product NX 10.

1978631

Siemens PLM believes that the problem you reported where "Existing Sew vs new Sew or Sheet Body vs Solid Body" will be resolved by code changes made to the upcoming release of our software NX 10.In addition: I have made a ppt to explain this issue in details, please refer to that PPT. "Why sewing sheets can generate a solid body and a fix for this PR.pptx" There's no problem of sew feature. A fix is also proposed in the PPT from customer's perspective. You may create either a solid or sheet body in this case. Close as FN. If you have further questions, please let me know.

1978891

NX 10 will have several enhancements to improve the performance and usability of the Replace Feature operation. Some enhancements are already available in NX 9.0.3 while some are in NX 10 only. The following aspects of Replace Feature workflow have been performance-enhanced in NX 10: 1. Generating the list of parent references to map from dependent features. 2. Automatic geometric matching of parent references. 3. Manual mapping and selection of the unmapped parent references. 4. List interactions and highlighting of references to map. 5. Applying the replacement mapping and model update after replace. As of NX 10, the PR complaints have been addressed from NX development perspective unless we hear otherwise from Daimler representatives. Please test this PR during the upcoming NX 10 D-Test-2.

1978961

The problem where "Save As New Item Type" is not inherit the attributes is fixed in NX 10.

1978968

Siemens PLM believes that the problem you reported where "3D swept mesh quality is not correct" will be resolved by code changes made to the release of our product NX 10.

1979062

Siemens PLM believes that the problem you reported where "a memory access violation occurs when trying to save a motion file with jt data" will be resolved by code changes made to the upcoming release of our software NX 10.

1979101

Siemens PLM believes that the problem you reported where you get "...session may be corrupt" error while closing assembly drawing will be resolved by code changes made to the upcoming release of our software NX 10.

1979130

Siemens PLM believes that the problem you reported where Import Results File with Long Path gives Error will be resolved by code changes made to the upcoming release of our software NX 10.

1979324

Siemens PLM believes that the problem you reported where "NX Open SetUserAttribute does not work with Number-Type Properties" will be resolved by code changes made to the upcoming release of our software NX 10.0 Backports are being considered.

1979366

Siemens PLM believes that the problem you reported where Error when copy and paste in modeling will be resolved by code changes made to the upcoming release of our software NX 10. Your can download a movie here: http://download.industrysoftware.automation.siemens.com/special.php/returned/PR 1979366_NX 10-clean.avi.7z

1979377

Siemens PLM believes that the problem you reported where even when suppressing a feature through an expression, PMIs are shown in the exported JT, will be resolved by code changes made to the upcoming release of our product NX 10.

1979403

Siemens PLM believes that the problem you reported where No Dimension to Sketch Origin will be resolved by code changes made to the upcoming release of our software NX 10. The problem where dimension option was not available when selecting a line and sketch origin has been fixed in NX 10. "Perpendicular Dimension" option will now be available for this specific selection combination.

1979410

The problem where Undefined Naming of Source-Part in Relation Browser with NX TC Integration is fixed in release NX 10.

1979618

Siemens PLM believes that the problem you reported where "Measure Distance Annotation setting changes after pressing F5" will be resolved by code changes made to the upcoming release of our software NX 10. Because: Prior to NX 10 the show dimension option was used a bit inconsistently, and was trying to indicate if the measurement dimension was currently on screen as well as whether the dimension should be shown when Ok/Apply was pressed. Meanwhile, F5 clears temporary geometry, and the measurement dimensions are temporary geometry which makes it more complicated. In NX 10 the show dimension option is now a check box so that it does not share the feedback choices with the construction of geometry. That combined with a change so that the logic has been simplified to make it more reasonable.

1979752

Siemens PLM believes that the problem you reported where Continuos Dimensioning is not honored in standard Flange Sketch will be resolved by code changes made to the upcoming release of our software NX 10. Continuous Auto Dimensioning setting will now be honored for the new Flange features.

1979824

Siemens PLM believes that the problem where legacy line widths are not mapped based on environment variables is fixed for drafting dialogs. Now all drafting dialogs will show mapped new width for legacy width. Legacy widths will be mapped based on following environment variables. UGII_CONVERT_LEGACY_THIN_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_NORMAL_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_THICK_LINEWIDTH_TO_NEW_LINEWIDTH This problem is fixed in NX 10. This fix is back ported in following MPs. NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP.

1979866

Siemens PLM believes that the problem you reported where Adding part to assembly, part disappears from preview window during constraining will be resolved by code changes made to the upcoming release of our software NX 10.

1979902

Siemens PLM believes that the problem you reported where Critical Problem with mirroring features will be resolved by code changes made to the upcoming release of our software NX 10.

1979980

Siemens PLM believes that the problem you reported where Deletion of copied Part Module not possible will be resolved by code changes made to the upcoming release of our software NX 10.

1980026

Solution: Use C# FileStream to export data instead of NXOPEN Session to avoid dotNet check.

1980324

Siemens PLM believes that the problem you reported where SB Closed Corner works not similar on two similar edges will be resolved by code changes made to the upcoming release of our software NX 10.

1980375

Siemens PLM believes that the problem you reported where Documentation gives wrong information about cell protection will be resolved by code changes made to the upcoming release of our software NX 10.

1980390

Siemens PLM believes that the problem you reported where Angle dimension failed will be resolved by code changes made to the upcoming release of our software NX 10. The issue that would occur in some cases where an angular dimension could not be created to the extension line of a linear dimension with tangent associativity has been fixed in NX 10. This issue would result in an error stating that the object did not have a matrix and was specific to angular dimension to the extension of another non-angular dimension.

1980468

Siemens PLM believes that the problem you reported where "Missing Annotation Origin Feature when Adopting a Title Block" will be resolved by code changes made to the release of our product NX 10.

1980542

Siemens PLM believes that the problem you reported where the toolpath direction was reversed in certain turning operations will be resolved by code changes made to the release of our product NX  8.5.3 MP7 Delta. The toolpath is generated in the correct direction again. In your part's first operation 'ROUGH_TURN_OD', our solution for MP7 may still come up with an unjustified "collision warning message". Just choose "Direct" then, in order to obtain a direct approach to your engage move for this operation, like it was made in your former correct version. This redundant message will go away with our next software update!

1980819

Siemens PLM believes that the problem you reported where "Smooth edges are shown in an Exact Section View unexpectedly" will be resolved by code changes made to the upcoming release of our software NX 10. First edit applied on the smooth edge was incorrect. Fist edit was non smooth. So the whole edge was treated as visible edge instead of smooth edge. Fixed code to apply proper edit on edge.

1980900

Siemens PLM believes that the problem you reported where a Condition Sequence Parameter can't be created with correct measure type will be resolved by code changes made to the upcoming release of our software NX 10.

1980982

Siemens PLM believes that the problem you reported where a routing part library .Net program crashes will be resolved by code changes made to the release of our product NX 8.5.3 MP6 and NX 10.The problem with the performance issue remains and a separate ER to track the performance problem needs to be opened. To address the performance problem, enhancements of the NX Open API will be required.

1981001

Siemens PLM believes that the problem you reported where "NX 9 OpenC API UF_DRAW_ask_sxsolids_of_sxview doesn't work when Exact view used" will be resolved by code changes made to the release of our product NX 10.

1981130

The problem where "Flat Pattern has missing holes for a circular pattern hole feature" is fixed in NX 10.

1981133

Siemens PLM believes that the problem you reported where "Explosion of deformable feature in assembly failed" will be resolved by code changes made to the upcoming release of our software NX 10.

1981178

Siemens PLM believes that the problem you reported where the Dimension on hole datum symbol is wrong will be resolved by code changes made to the upcoming release of our software NX 10 (only for new holes).

1981221

Siemens PLM believes that the problem you reported where System crash after using the option Tools -> Expression will be resolved by code changes made to the upcoming release of our software NX 10.

1981353

Siemens PLM believes that the problem you reported with definition of center in closed corner will be resolved by code changes made to the upcoming release of our software NX 10. The CloseCorner feature needs to be re-created in NX 10.

1981363

Siemens PLM believes that the problem you reported where Section line segment no more selectable after clicking "Apply" will be resolved by code changes made to the upcoming release of our software NX 10.

1981549

The Check-Mate "Tiny solid:G-SO-TI" checker in the SASIG-PDQ Solid category has been enhanced to log additional messages to indicate that the solid mass property check fails when the test part has model errors. This problem is fixed in release NX 10.

1981631

Siemens PLM believes that the problem you reported where "Edit Feature Playback failed in higher version NX 9.0.1.3 D1 for A2386361300" will be resolved by code changes made to the upcoming release of our software NX 9.0.3.1. EB136 is fixed in NX 9.0.3.1 using ps26.1.221 as stated above. However, the original part seems to be unstable. Part successfully replays one time, but fails on the next replay. Cannot determine the cause of the instability in nx9031; when I replay the part multiple times in will fail somewhere. I did clean and update the part in the last saved version of the part, NX 8.5.2.3. That updated part is called: A2386361300_2_cleanded_updated_nx8523.prt The updated part works correctly in NX 9.0.3.1 and NX 10.15 and seems stable, ie. I replayed it 10 times in each version and no failures. Going to close the part as fixed, however the updated part should be used in the future.

1981846

Siemens PLM believes that the problem you reported where "Gouge Issue in "Z-LEVEL 5 Axis" when Tool Offset Insertion is Defined in Holder" will be resolved by code changes made to the release of our product NX 10 and future MP release of NX 9.0.3.

1981944

Siemens PLM believes that the problem you reported where "GD&T (Datum Feature Symbol) not correctly exported to DWG" will be resolved by code changes made to the upcoming release of our software NX 10.

1982012

Siemens PLM believes that the problem you reported where Stud and Surfacing weld not displaying correctly in Weld symbol dialog will be resolved by code changes made to the upcoming release of our software NX 10.

1982299

Siemens PLM believes that the problem you reported where some column names are missing from the documentation will be resolved by code changes made to the upcoming release of our software NX 10. Updated the NX 10 Modeling Help documentation topic "Standard data tables for Hole Features", to add the following entries to the column names in the NX 502_Threaded_Hold_Standard.xml file" section of the table: *ScrewStandard - Specifies the standard that defines the options and parameters used to create the screw clearance hole. *ScrewType - Included here with a default value for a Screw Clearance Hole, in case the hole Type is changed in the Hole dialog box from Threaded Hole to Screw Clearance Hole. The available options in the Screw Type list depend on whether Form is set to Simple, Counterbored, or Countersunk. *ScrewSize - Included here with a default value for a Screw Clearance Hole, in case the hole Type is changed in the Hole dialog box from Threaded Hole to Screw Clearance Hole. Specifies the screw size for the selected Screw Type used to create a Screw Clearance Hole. *ScrewFit - Included here with a default value for a Screw Clearance Hole, in case the hole Type is changed in the Hole dialog box from Threaded Hole to Screw Clearance Hole. Specifies the required Fit parameter for a Screw Clearance Hole. NX 10 will be ready for customer download from 23-Dec-2014.

1982309

Siemens PLM believes that the problem you reported where 2D Section template containing joined curves locks pole position on placement will be resolved by code changes made to the upcoming release of our software NX 10.The problem is only fixed for new splines created in that version. For existing splines (like the PR case), the user needs to do a NULL edit to upgrade the spline to new spline and after that, the spline can be moved without getting deformed.

1982339

Siemens PLM believes that the problem you reported where selecting a feature group containing measurements causes all measurements to display will be resolved by code changes made to the upcoming release of our software NX 10.

1982370

Siemens PLM believes that the problem you reported where a Reference dimension cannot be hidden on mirror feature will be resolved by code changes made to the upcoming release of our software NX 10.

1982413

Siemens PLM believes that the problem you reported where "Incorrect results converting PMI drawings with UGto2D translator" will be resolved by code changes made to the upcoming release of our software NX 10.

1982478

Siemens PLM believes that the problem you reported where SB Resize Bend Angle does not work for specific values will be resolved by code changes made to the upcoming release of our software NX 10. In NX 10 , all other value ranges work fine except "99.6° - 95.8°". The reason why the bend could not be changed angle to "99.6° - 95.8°" is because this value angel is too close to its original bend angle. A workaround is available to make this change. 1.) Resize Bend Angle to a bigger or smaller angle, i.e. 90 degree, 2.) Resize Bend Angle again to desired angle, i.e. 98 degree will succeed.

1982671

The problem where "RESIZE BEND ANGLE: Changing to some value ranges is not possible" is fixed in NX 10.

1982713

Siemens PLM believes that the problem you reported where "Feature Playback from part fmsr_48851e8e04a711e3b01a3c4a927874ee----.prt results in error in NX9 will be resolved by code changes made to the release of our product NX 10.

1982789

The problem where hiding of a nested custom symbol while edit the symbol is not possible is working as designed. You cannot use invisible objects to create or edit master symbol definitions. The following note was added to the overview information in the Drafting Help NX 10 for both the Define Custom Symbol and Edit Custom Symbol commands: "Only visible objects are used to define a master custom symbol. While creating or editing a master custom symbol, if objects are on an invisible layer, or are hidden, they will not be added to the master custom symbol definition."

1982797

Siemens PLM believes that the problem you reported where "defective format in information window" will be resolved by code changes made to the upcoming release of our software NX 10.

1982834

The problem where imported drawing template did not have drawing borders is fixed in NX 10.

1982953

Siemens PLM believes that the problem you reported where Changing line widths does not work for drafting objects will be resolved by code changes made to the release of our product. The problem where legacy line widths are not mapped based on environment variables is fixed for drafting dialogs. Now all drafting dialogs will show mapped new width for legacy width. Legacy widths will be mapped based on following environment variables. UGII_CONVERT_LEGACY_THIN_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_NORMAL_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_THICK_LINEWIDTH_TO_NEW_LINEWIDTH This problem is fixed in NX 10. This fix is back ported in following MPs. NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP.

1982994

Siemens PLM believes that the problem where radials and popup menus appear in the incorrect position when running with Windows text settings greater than 100% is fixed in release NX 9.0.3 and NX 10.There is also a workaround to the issue prior to these releases. On the NX executable, right-click and select Properties. Select the Comparability tab and toggle the option for "Disable display scaling on high DPI settings" NX 9.0.3 will be ready for customer download from 30-Sep-2014. NX 10 will be ready for customer download from 23-Dec-2014.

1983028

Siemens PLM believes that the problem you reported where Sheetmetal rebend is not working will be resolved by code changes made to the upcoming release of our software NX 10.

1983046

Siemens PLM believes that the problem you reported where ""evcrvu.c: Unknown curve type" appears when updating drawing view" will be resolved by code changes made to the release of our product NX 10.

1983059

The problem where no Journal Automation for "File -> Force Save All" is available although the method "NXOpen -> PartCollection -> ForceSaveAll()" exists will be solved by code changes made to the upcoming release of our software NX 10.

1983153

Siemens PLM believes that the problem you reported where installation script fails with an "arithmetic syntax error", will be resolved by code changes made to the upcoming release of our software NX 10. Follow explanation and possible WA: The script code at line 2557 did not perform arithmetic correctly on a decimal number (i.e. 9.0). The result was truncated to a simple integer (i.e 27). No fix for NX 9 as the DVD is already out in the field. Workarounds for NX 9: For a single install, simply edit the /ugs/installed_programs.dat to change "27" to "27.0". For multiple installs, edit the install script and change line 2557: From: UG_VER="$(($NX_VER + 18))" To: UG_VER="27.0".

1983159

Siemens PLM believes that the problem you reported where a number of significant performance issues were encountered when using NX 7.5.5 with a model which included many groups and laminates will be resolved by code changes made to the upcoming release of our software NX 10.

1983162

Siemens PLM believes that the problem you reported where laminate 'compute zone' performance is slower in NX 9.0.1 than NX 7.5.5, and slower again when using 'edit in context' (NX 9.0.1), will be resolved by code changes made to the upcoming release of our software NX 10.

1983192

Siemens PLM believes that the problem you reported where Dimensions and labeled tabular note not correctly translated to DWG will be resolved by code changes made to the upcoming release of our software NX 10.

1983371

Problem where some customer defaults settings are not correctly loaded "From Search folders" as Assembly Load Options is fixed in NX 10.

1983487

Siemens PLM believes that the problem you reported where custom attributes in tooldata for export tools disturbs NX Tool Creation will be resolved by code changes made to the upcoming release of our software NX 10.

1983522

Siemens PLM believes that the problem you reported where the toolpath direction was reversed in a roughing operation machining multiple cut regions in a single setting will be resolved by code changes made to the release of our product NX  8.5.3 MP7 Delta. The toolpath is generated in the correct direction again! However, it is required that you correct two input parameters in order to obtain the same cutting motions as before: a) Select "Cutting Parameters -> Profiling(tab) -> Path Settings -> Strategy = Finish All" (...which is the correct setting for your Level Angle specified) b) Increase your Cut Depth value to "Maximum = 6 mm" (...otherwise, the system generates two rough cuts in addition to the profiling pass).

1983852

Siemens PLM believes that the problem you reported where new instances in Teamcenter with mirror transformations would be loaded in NX without any message to the user has been fixed. Since NX does not support mirror or other non-rigid body transforms coming directly from Teamcenter, components with such transforms are placed in NX at either their internal NX part file transform (for existing components) or at the origin (for new components). In either case a warning message should be displayed to the user to this effect. This fix makes sure the message is displayed for both new and existing components. The fix will appear in NX 10.

1983861

Siemens PLM believes that the problem you reported where NX crashes when import merge of HRN file into electrical connection navigator will be resolved by code changes made to the upcoming release of our software NX 9.0.2 Rev A, NX 9.0.3 and NX 10.

1983896

Siemens PLM believes that the problem you reported where Rebend failed will be resolved by code changes made to the upcoming release of our software NX 10.

Note: to verify the fix, the last 2 unbend features need to be update by (either suppress/unsuppress or feature playback), then rebend will succeed.

1984157

Siemens PLM believes that the problem you reported with wrong behavior of File Open when advanced search is uses will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014.

1984306

Siemens PLM believes that the problem where legacy line widths are not mapped based on environment variables is fixed for drafting dialogs. Now all drafting dialogs will show mapped new width for legacy width. Legacy widths will be mapped based on following environment variables. UGII_CONVERT_LEGACY_THIN_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_NORMAL_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_THICK_LINEWIDTH_TO_NEW_LINEWIDTH This problem is fixed in NX 10. This fix is back ported in following MPs. NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP.

1984417

Siemens PLM believes that the problem you reported where Face Blend works or not if the target and tool is permuted will be resolved by code changes made to the upcoming release of our software NX 10. Before NX 10, Face Blend works on Master face concept, where in the first face for both the wall chains needed to be same to keep the result consistent when the wall chain faces are permuted. This drawback has been enhanced by a recent project in Face Blend and the new functionality is available in NX 10 and later version. If the Face Blend is created in NX 10, the user should see same result when the wall chain 1 and 2 faces are interchanged. Since this was an enhancement to the existing face blend functionality, it cannot be backported to an earlier NX version.

1984646

Siemens PLM believes that the problem you reported where Feature Playback failed in NX 9 will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014.

1984703

Siemens PLM believes that the problem you reported where Feature Playback failed in NX 9 for MFA_RB@0000001865_1.prt will be resolved by code changes made to the upcoming release of our software NX 10.

1984807

Siemens PLM believes that the problem you reported where the Help text in customer defaults uses term Locking policy and not check in policy will be resolved by code changes made to the upcoming release of our software NX 10.

1985045

Siemens PLM believes that the problem you reported where Performance Issue when changing length of Stiffener will be resolved by code changes made to the upcoming release of our software. The problem where changing the length of a stiffener triggered an update of the entire assembly has been fixed in NX 10. The PR parts cannot be fixed. The customer should be given a best practice to create corner cuts and similar features prior to applying Profile Cutouts to avoid unneeded updates. Additional information send to responsible SPLM employee.

1985061

Siemens PLM believes that the problem you reported where Copy parts between planes Performance is slow will be resolved by code changes made to the release of our product NX 10.

1985105

Drill Operation will not simulate correctly when Rtrcto is set to Auto.

1985133

The problem where Missing information about out of date status, is fixed in NX 10.

1985134

Siemens PLM believes that the problem you reported where Part updates during loading will be resolved by code changes made to the upcoming release of our software NX 9.0.3. This version will be ready for customer download from 09-Sep-2014.

1985273

Siemens PLM believes that the problem you reported where "(Von_mises results)^2 through results Manipulation, are not correct" will be resolved by code changes made to the upcoming release of our software NX 10.

1985313

The problem where a leader attached to the text on top of a Feature Control Frame, instead of to the Feature Control Frame, is fixed in NX 10.

1985351

The problem where the part goes out-of-date when replacing reference set on a component with delay inter part updates turned on has been fixed in NX 10. The problem is specific to certain kinds of broken structure dependent inter part links - where the link is broken because components or sub-assemblies were deleted from the structure, but other parts of the structure are still valid. In addition, after the link is broken because of these structure changes, one of the remaining components should have a change in position.

1985352

This PR shows that when editing Weld Points the End Distances are not retained. This problem has been fixed in NX 10 with the Weld Point Wizard dialog.

1985411

The NX was hanging because of large number of elements (>100000) is reflected (i.e. created) one by one. New performance improvement code is added to element creation which reduced the creation time from 1400+ seconds to 20 seconds for customer model. The new performance improvement code is added in NX 10.

1985538

Siemens PLM believes that the problems you reported where:

1 - laminate ply component stresses are plotted incorrectly when displayed as tensors within post-processing and

2 - component stresses on shell elements which reference an isotropic material are plotted incorrectly when the stresses are plotted with respect to the native (element) coordinate system within post-processing will be resolved by code changes made to the upcoming release of our software NX 10.

1985561

Siemens PLM believes that the problem you reported where "Wrong Major Diameter is inherited from customized thd_metric.dat file" will be resolved by code changes made to the upcoming release of our software NX 10.

1985752

Siemens PLM believes that the problem you reported where "Unable to create View Break" will be resolved by code changes made to the upcoming release of our software NX 10.

1985896

Siemens PLM believes that the problem you reported where Nested CustomSymbols show all options at the same time will be resolved by code changes made to the upcoming release of our software NX 10.

1985962

Siemens PLM believes that the problem you reported where NX 9 - NX Open: CreateFlangeFeatureBuilder leads to corrupt NX Session will be resolved by code changes made to the upcoming release of our software NX 10.

1986149

Siemens PLM believes that the problem you reported where it is possible to encounter an apparent software 'hang' when using the 'import layup from spreadsheet' function on the laminates 'layup modeler' form will be resolved by changes made to the help documentation in the upcoming release of our software NX 10. Specifically, the help documentation for NX 10 has been improved to let the user know that when using the 'import layup from spreadsheet' function on the laminates 'layup modeler' form, the user must copy the layout from the imported spreadsheet to the opened worksheet.

1986211

For the provided assembly it wasn't possible to determine a root cause that causes that 'problematic' CSYS, for this assembly the only way to fix the corrupted wave linked CSYS is to edit it (as already reported by the customer); moreover the customer wasn't able to provide a workflow, i.e. some steps that starting from a working model generates such a kind of corrupted CSYS, so it wasn't possible for dev. to detect any kind of possible bugs existing in NX. However we found (for another PR) one workflow which can lead to such a corruption, exactly like the reported PR case and we believe this might be the root cause even of this PR. We have fixed this root cause in NX 10. Thus, close this PR as FN against NX 10.

1986312

Siemens PLM believes that the problem you reported where "Wrong Major Diameter is inherited from customized thd_metric.dat file" will be resolved by code changes made to the upcoming release of our software NX 10.

1986329

Siemens PLM believes that the problem where the Assemblies Help needed more information about how the reference sets used to load child components can vary based on which reference set their immediate parent is using is fixed in release NX 10. Additional information has been added to the Reference Sets section in the documentation.

1986344

Siemens PLM believes that the problem you reported where "Unable to Simulate a Toolpath in 3D Dynamic" will be resolved by code changes made to the release of our product NX 10.

1986505

Moving the position of an RCP can cause a Routing Constraint to be lost.

1986613

Siemens PLM believes that the problem you reported where an Electrode assembly drawing doesn't show the Electrode Fixture as of NX8 will be resolved by code changes made to the upcoming release of our software NX 10.

1986727

Siemens PLM believes that the problem you reported where Model Setup Check does not properly validate material stress-strain data for kinematics hardening will be resolved by code changes made to the upcoming release of our software NX 10.

1986780

Siemens PLM believes that the problem you reported where opening assembly in PTS took too much time will be resolved by code changes made to the upcoming release of our software NX 10.

1986834

Siemens PLM believes that the problem where legacy line widths are not mapped based on environment variables is fixed for drafting dialogs. Now all drafting dialogs will show mapped new width for legacy width. Legacy widths will be mapped based on following environment variables. UGII_CONVERT_LEGACY_THIN_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_NORMAL_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_THICK_LINEWIDTH_TO_NEW_LINEWIDTH This problem is fixed in NX 10. This fix is back ported in following MPs. NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP.

1986878

Siemens PLM believes that the problem you reported where performing an adaptive analysis of a specific model fails with the error: *** USER FATAL MESSAGE 4306 (ETR6D) DEGENERATE GEOMETRY OR INADEQUATE MATERIAL DATA SPECIFIED FOR TRIA6 ELEMENT WITH ID = 60 REASON NUMBER = 28 User information: See UFM 4288 for an explanation of reason numbers, except that Reason 28 corresponds to CODE 21. ^^^ USER FATAL MESSAGE 9031 (ERRPH1) ^^^ NOGO ENCOUNTERED IN SUBDMAP SEMG will be resolved by code changes made to the upcoming release of our software NX 10.Note that adaptively has been completely re-worked in NX 10.This example was working as expected in NX 9.0, in that if the solver fails, the adaptive process terminates. In NX 10 this example solves successfully through to completion due to functionality enhancements made to both NX adaptive mesh refinement and NX Nastran.

1986958

Siemens PLM believes that the problem you reported where " NX fem is hanging with " auto stitch edge to face" (see NX file for the errors)" will be resolved by code changes made to the upcoming release of our software NX 10.

1986994

Siemens PLM believes that the problem you reported where the KF function 'ug_excel_read' fails to read a named cell from a non-active sheet will be resolved by code changes made to the upcoming release of our software NX 10. The documentation for functions like ug_cell_read have been changed to cover the use of a sheet name in the cell specification so that the read is not dependent on the currently active worksheet.

1987049

Siemens PLM believes that the problem you reported where more description is required for Measure Bodies - Products of Inertia has been fixed in NX 10. The Measure Bodies Information window topic has been updated. http://lmdbuild/tdoc/nx/10/nx10-nx_tdoc_collection-en_US/#uid:index_measure_ent er_values:analysis_ana_massprop_ov:analysis_ana_massprop_rt.

1987150

Siemens PLM believes that the problem you reported where "File Save As command generates a large fem-file" will be resolved by code changes made to the release of our product NX 10.

1987292

(MRL/NXAutoAssembly) Different names for TOOL_TIP and TOOL_MOUNT.

1987295

(MRL/NXAutoassembly) TOOL_MOUNT is wrong.

1987297

(MRL/NXAutoAssembly) No SIEMENS_TOOL_MOUNT.

1987301

(MRL/NXAutoAssembly)TOOL_TIP and TOOL_MOUNT orientations are wrong.

1987303

(NX/MRLAutoAssembly) Setup values are swapped.

1987439

Siemens PLM believes that the problem you reported where mesh control settings defined using 'menu, insert, mesh, mesh control, biasing on edge' are not honoured when applied to a '3d tetrahedral mesh' will be resolved by code changes made to the upcoming release of our software NX 10. Note that this problem is a software regression in NX 9.0.1 (it does not occur in NX 8.5.3). Also note that these same settings are honoured if applied to a '2d (free) mesh', which means that this problem can be worked around by creating a thin shell element 'seed' mesh (export mesh to solver = off) on a surface whose boundary includes the appropriate edge. This seed mesh will honour the mesh control setting defined on the edge, and will drive the 3d tetrahedral mesh to do the same.

1987464

Siemens PLM believes that the problem you reported where the Mold Wizard Runner UI doesn't change the workpart as defined by the PARENT definition will be resolved by code changes made to the upcoming release of our software NX 10.

1987468

Siemens PLM believes that the problem you reported where part cannot be loaded will be resolved by code changes made to the upcoming release of our software NX 10.

1987520

Siemens PLM believes that the problem you reported where Edit Work Section is grayed out by verfing a complete Program-Group will be resolved by code changes made to the release of our product NX version NX 10 and NX 9.0.3 MP 1.

1987663

Siemens PLM believes that the problem you reported where FeaturePlayback failed in NX9 for part "Inlet Port D=92.9 DE35.prt" will be resolved by code changes made to the release of our product NX 10. This part contains several Section surfaces which have been enhanced in NX 9 and NX 10. Unfortunately, the fixes is under version control. So the original part still can't fully update itself, unless you re-do it in NX 10. I have uploaded a fixed part as "Port D-92.9 DE35_nx10.prt" \tin which I upgrade the 3 section surface (218, 219 and220) version. So you should be able to run a update without problem in NX 10. Now I'll close this PR as fixed, but sorry you have to use the NX 10 (and re-do this model.)

1987664

Siemens PLM believes that the problem you reported where "Part Module: Reselection of output geometry is not possible" will be resolved by code changes made to the upcoming release of our software NX 10.

1987688

Siemens PLM believes that the problem you reported where Flat Pattern bend annotations not visible when printing Sheet Metal drawings will be resolved by code changes made to the upcoming release of our softwareNX 10. The fix require object structure changes and hence cannot be ported back to a previous release.

For pre-nx10 drawings to print annotations correctly in NX 10 or later, user need to follow these steps -

1. Open the drawing in NX 10 or later with full load option.

2. Update the flat pattern drafting view.

3. Save. After this, the annotations will print correctly.

1987781

Siemens PLM believes that the problem you reported where Join Curve creates the wrong type due to Modeling preferences, will be resolved by code changes made to the release of our product NX 10.

1987864

Siemens PLM believes that the problem you reported where: NX Crashed during post result will be resolved by code changes made to the release of our software NX 10.

1987954

Siemens PLM believes that the problem you reported where "no error sign at the Offset Face" will be resolved by code changes made to the upcoming release of our software NX 10.

1988044

The problem where drafting thread curves are missing a transform and therefore incorrectly displayed in new exact, revolved section views is fixed in NX 10.

1988141

Siemens PLM believes that the problem you reported where "Internal error for Z-Level Operation" will be resolved by code changes made to the release of our product NX version 10 and submitted for a future MP release of NX 9.0.3.

1988146

Siemens PLM believes that the problem you reported where Unable to open drawing - Object supplied is of the wrong type will be resolved by code changes made to the upcoming release of our software. The problem where error message comes "Unable to open drawing - Object supplied is of the wrong type" is fixed in nx10.

1988437

Siemens PLM believes that the problem you reported where the following three articles related to 'edge to surface gluing' within the NX 9 help documentation contain erroneous references to BLSEG (the legacy nx Nastran entry for 'edge to surface glue' definitions): - Edge-to-Surface Gluing (NX Nastran) - Controlling the stiffness of edge-to-surface glue (NX Nastran) - Define edge-to-surface gluing will be resolved by code changes made to the upcoming release of our software NX 10.

1988450

Siemens PLM believes that the problem you reported where, when trying to open the .op2 results file in NX after solving a specific fea model, the software displays the pop-up message: work in progress please wait for the operation to complete for about 15-20 seconds and then the following pop-up message box is displayed: result not loaded unknown error occurred will be resolved by code changes made to the upcoming release of our software NX 10.

1988603

When changing to shaft, the tolerance values are not changing in Edit dialog box.

1988941

Siemens PLM believes that the problem you reported where you are Unable to open drawing - The planar face cannot be projected will be resolved by code changes made to the upcoming release of our software NX 10.

1988960

Mass element warning appearing in Model Setup Check.

1989027

Siemens PLM believes that the problem you reported where A created Tire Envelope with NX 8.01 shows a wrong geometry in NX 8.5 or in NX 9 will be resolved by code changes made to the upcoming release of our software NX 10.

1989071

Siemens PLM believes that the problem you reported where Layers without any accessible objects will be resolved by code changes made to the release of our product NX 10.

1989093

The problem where error occurs attempting to replace component has been fixed in NX 10.

1989097

Siemens PLM believes that the problem you reported where the User Exit "Substitute Component In" doesn't show the part from 'param' input with NX/Manager will be resolved by code changes made to the upcoming release of our software NX 10.

1989120

Siemens PLM believes that the problem you reported where Reflection plane for copy and reflect not created at correct location will be resolved by code changes made to the upcoming release of our software NX 10.

1989287

Siemens PLM believes that the problem you reported with a Problem with your UDF parts when you use Mirror Feature command in NX will be resolved by code changes made to the upcoming release of our software. The problem where mirror of sketch produces the wrong result is fixed in release NX 10.

1989303

Siemens PLM believes that the problem you reported where Thread parameters not updated when changing form type will be resolved by code changes made to the upcoming release of our software NX 10.

1989519

Siemens PLM believes that the problem you reported where attribute "DESCRIPTION" is not created is fixed and the fix is submitted to NX 10 ip16, NX 9.0.3 delta and NX 8.5.3 MP.

1989523

Siemens PLM believes that the problem you reported where save aborted when saving a drawing will be resolved by code changes made to the upcoming release of our software NX 10.

1989577

Siemens PLM believes that the problem you reported where inconsistent units after unsettling attribute from or not from attribute template, will be resolved by code changes made to the upcoming release of our software NX 10, NX 9.0.3 and NX 8.5.3 MP.

1989688

Siemens PLM believes that the problem you reported where bridge curve shines through will be resolved by code changes made to the upcoming release of our software NX 10.

1989720

Siemens PLM believes that the problem you reported where NX Refile Option -set_new_dataset_o does not work on NX Dataset from JT Dataset will be resolved by code changes made to the upcoming release of our software NX 10.

1989736

Siemens PLM believes that the problem you reported where "Drawing can not be opened using assembly load options "Structure Only"" will be resolved by code changes made to the release of our product NX version NX 10 IP20. Now part will get opened properly but user need to do part cleanup once part opened.

1989818

The problem that using notes in Reuse Library is not longer possible like it was in NX 6 is fixed in release NX 10.

1989833

There are 2 different but related issues for this PR

1) A message is given that none of the axisymmetric are located on a valid plane ***ERROR : None of the axisymmetric, plane stress or plane strain elements are located on a valid plane. Import using an XY axisymmetric extension.

2) An invalid location was found for GRID 221 ***ERROR : Invalid location for GRID/SPOINT referenced by SPC1 . First occurrence is SPC1 1 referencing GRID/SPOINT 221 Both of these stem from the GRID locations not being on the ZX plane. Looking at GRID 221 we have GRID 221 1 286.5 -7.02-153947.29 1 Where CORD2C 1 0. 0. 0. 0. 0. 1. 1. 0. 0. and R = 286.5 THETA = -7.02-15 Z = 3947.29 This evaluates in NX to an absolute position of (286.50000000000000, -3.5102585514885554e-014, 3947.29000000000000) In NX900, checking for ZX Axisymmetric status is done by using the criteria of having a Y component as 0.0. In NX 10 a tolerance will be used to account for round-off.

This will resolve both issues. The fix will be into NX 10.

1989866

Siemens PLM believes that the problem you reported where the option "keep target" in trimmed sheet is causing update problems will be fixed for NX 10. The workflow described in the PR text works now as new 'important' entities are reported by Replacement Assistant for mapping.

1989935

Siemens PLM believes that the problem you reported with recognition of intersecting holes (Partitial Holes) will be resolved by code changes made to the upcoming release of our software NX 10.

1990002

Siemens PLM believes that the problem you reported where "Model Check does not detect missing information in joint definition" will be resolved by code changes made to the upcoming release of our software NX 10.

1990003

Siemens PLM believes that the problem you reported where "after a mechanism import into a top assembly several joints only show partial associativity" will be resolved by code changes made to the upcoming release of our software NX 10.

1990106

The problem where a GD&T frame doesn't appear in the preset color when a custom symbol is inserted is fixed for new annotations in release NX 10. Existing annotations with this problem can be fixed by using version up.

1990345

The problem where the rough offset function produces bumpy surfaces if the offset is > 75 mm is fixed in release NX 9.0.2 mp2, NX 9.0.3 mp1 and NX 10.

1990349

Siemens PLM believes that the problem you reported where "Wrong Major Diameter is inherited from customized thd_metric.dat file" will be resolved by code changes made to the upcoming release of our software NX 10.

1990375

Siemens PLM believes that the problem you reported where "Internal error: memory access violation" updating a Detail View will be resolved by code changes made to the upcoming release of our software NX 10.

1990400

Siemens PLM believes that the problem you reported where Corrupt part files regarding the db_part_no will be resolved by code changes made to the upcoming release of our software NX 10. This part has a value of DB_PART_NO cached in a slightly unexpected way. The system has been fixed to cope with this state in such a way that it will not show up in the user interface. There is no known workaround at present.

1990441

Siemens PLM believes that the problem you reported where Deform feature can't be created on SM part,that was spitted into two bodies will be resolved by code changes made to the upcoming release of our software NX 10.

1990469

Siemens PLM believes that the problem you reported where Invalid cast on Formboard.ShapeSegmentBuilder.GetLineData will be resolved by code changes made to the upcoming release of our software NX 9.0.2 MP, NX 9.0.3 and NX 10.

1990672

Siemens PLM believes that the problem you reported where Move selected component failed will be resolved by code changes made to the upcoming release of our software NX 10.

1990673

Siemens PLM believes that the problem you reported for failing "Blend Corner Tolerance" will be resolved by code changes made to the upcoming release of our software NX 10.

1990701

The problem where Boolean Face color doesn't take the tool color when the target is a promoted is fixed in release NX 10.

1990724

Siemens PLM believes that the problem you reported where "Corrupt FEM file occurred after geometry update" will be resolved by code changes made to the upcoming release of our software NX 10.

1990740

Siemens PLM believes that the problem where Drawing can not be opened when 3D-PRT is missing is fixed in NX 10. Now part will get opened properly but user need to do part cleanup once part opened.

1990757

Siemens PLM believes that the problem you reported where Associative Position from Standardpart in PDW will be resolved by code changes made to the release of our product NX version 10. The problem where Associative Position from Standardpart in PDW has been investigated and the following has been found. From the AVI, I guess user make a mistake for the association, if it's associative, it means the added standard part is associative with the referenced point user defined, not the position point the standard part added. So I close this PR with designed as intended.

1990771

Siemens PLM believes that the problem you reported where Unable to create Section view will be resolved by code changes made to the release of our product version NX 10.

1990788

The problem where DB_LP_CHECKED_BY attribute is not updated in the drafting sheet, is fixed in NX 8.5.3 MP6 and later releases.

1990901

Siemens PLM believes that the problem you reported where Get "Internal error: memory access violation" removing a feature group will be resolved by code changes made to the upcoming release of our software NX 10.

1990922

Siemens PLM believes that the problem you reported where Sketch Pattern Curve gives internal error running NX in Polish will be resolved by code changes made to the upcoming release of our software NX 10.

1990989

Siemens PLM believes that the problem you reported where "Meshing pop up" when calling NX Open functions" will be resolved by code changes made to the upcoming release of our software NX 10.

1991191

Siemens PLM believes that the problem you reported where Insert Sketch from 2D Section Library failed if the dimension is a driving dimension will be resolved by code changes made to the release of our software NX 10.

1991225

Siemens PLM believes that the problem you reported where SAE Standard for Head Contour is missing in the info will be resolved by code changes made to the upcoming release of our software NX 10.This version will be ready for customer download from 23-Dec-2014.

1991233

Siemens PLM believes that the problem you reported where Eyellipse and Head Contour positions don't change will be resolved by code changes made to the upcoming release of our software NX 10.This version planned for customer download 23-Dec-2014.

1991343

Siemens PLM believes that the problem you reported where Check-Mate SASIG-PDQ "Embedded solid:G-SO-EM" checker reports wrong results for embedded solids will be resolved by code changes made to the upcoming release of our software NX 10.

1991434

Siemens PLM believes that the problem you reported where Unable to update Part Spun Outline => circular update was detected will be resolved by code changes made to the upcoming release of our software NX 10.0.19

1991448

Siemens PLM believes that the problem you reported where NXOpen : Measure Bodies gives an Incorrect Unit in the Information Window will be resolved by code changes made to the upcoming release of our software NX 10.

1991461

Siemens PLM believes that the problem you reported where Mirror Feature: result of mirrored UDF is not correct will be resolved by code changes made to the upcoming release of our software NX 10.

1991477

Siemens PLM believes that the problem you reported where "Neutral Factor is NOT changed via Expressions dialog" will be resolved by code changes made to the release of our product NX 10.

1991755

Siemens PLM believes that the problem you reported where "Unknown error occurred" with postprocessing results when MPC objects were used will be resolved by code changes made to the release of our software NX 10.

1991847

Siemens PLM believes that the problem you reported where Linked Part Module cannot be updated will be resolved by code changes made to the upcoming release of our software NX 10. Problem where part goes out of date when parent of input datum co-ordinate system is deleted with delete child features ON in customer defaults is fixed in NX 10 Ip18. Now part will not go out of date as delete child feature ON and input datum coordinate system is also getting deleted with parent. After this linked part module can be made up to date for merge operation.

1991875

Siemens PLM believes that the problem you reported where Slow opening the .sim file will be resolved by code changes made to the upcoming release of our software NX 10.

1991907

Siemens PLM believes that the problem you reported where Expression 'ceil' function returns wrong values with 'Constant' units will be resolved by code changes made to the upcoming release of our software NX 10.

1991917

Siemens PLM believes that the problem you reported where System crashed by "Edit Sketch" will be resolved by code changes made to the upcoming release of our software NX 10. The issue with this part where a crash would occur when attempting to edit the sketch has been fixed. To access this fix, first do part cleanup for drafting objects on the part and this will resolve the issue so the sketch can be edited.

1991943

Siemens PLM believes that the problem you reported where Wrong result of pattern feature will be resolved by code changes made to the upcoming release of our software NX 10. Download the WA here: http://download.industrysoftware.automation.siemens.com/special.php/returned/PR 1991943-WA-clean.7z

1991956

Siemens PLM believes that the problem you reported where "Ungenauer Maßstab einer Ausschnittsvergroesserung einer Zeichnung" will be resolved by code changes made to the upcoming release of our software NX 10.

1992062

Siemens PLM believes that the problem where the information of the UGII_ROUTE_CONFIG_RULE environment variable is not documented is fixed in release NX 10.The updated information is available in NX 10. Help at the following location: Home-->CAD-->Routing Systems-->Routing configuration guide-->Setting up the Routing environment-->Common environment variables for Routing The information reads as: UGII_ROUTE_CONFIG_RULE Loads the last configuration of the part if a part fails to load because its current configured option is not found. In Teamcenter Integration for NX, to allow routing commands such as Place Part and Assign Stock to work with the Precise revision rule, you must set this environment variable to Latest Working. You can also achieve the same setting by changing the revision rule itself to Latest Working.

1992130

Siemens PLM believes that the problem you reported where CatiaV5 translation fails with "expected transient xmt_txt file does not exist" will be resolved by code changes made to the release of our product NX 10 CATIAV5 Translator.

1992153

Siemens PLM believes that the problem you reported where "Turning : Incorrect Material Removal when Reorient Tool Holder is used" will be resolved by code changes made to the release of our product NX version NX 9.0.3 MP1 and NX 10.

1992166

Siemens PLM believes that the problem you reported where IGES did not export "mu" symbol correctly to IGES file using IGES1002 font will be resolved by code changes made to the release of our product NX 10.

1992228

Siemens PLM believes that the problem you reported where the usage of the Block UI Styler 'Drawing Area' block capabilities is not clear enough will be resolved by code changes made to the upcoming release of our software NX 10. The documentation will be corrected to read "The Drawing Area block provides a control to display an area in the command's dialog box that can be used to show JPG,BMP,TIFF and PNG pictures." Also the file selection dialog will now include options for all available file types.

1992259

Siemens PLM believes that the problem you reported where "no intersection detected during parallel dimensioning" will be resolved by code changes made to the release of our product NX 10.

1992290

Siemens PLM believes that the problem you reported where "NXOpen/Journal: DraftingView.ViewBreaks-Collection throws exception" will be resolved by code changes made to the release of our product version NX 10.

1992368

Siemens PLM believes that the problem you reported where an excessive time is needed to load a master assembly of a drafting part will be resolved by code changes made to the upcoming release of our software NX 10.

1992421

Siemens PLM believes that the problem you reported where Electrical Routing:LostConstraintDuringRCP-Movement will be resolved by code changes made to the release of our product NX 10. The problem where a constraint could be lost when moving an RCP is fixed in NX 9.0.2 MP2, NX 9.0.3, and NX 10.

1992451

Siemens PLM believes that the problem you reported where NXOpen : Can't get Components of a User Defined Order will be resolved by code changes made to the upcoming release of our software NX 10.

1992516

Siemens PLM believes that the problem you reported where Constraints are not created for Routing Parts with engagement values defined on port will be resolved by code changes made to the release of our product NX 10.

1992532

Siemens PLM believes that the problem you reported where mirror certification cannot create the correct mirror boundary will be resolved by code changes made to the upcoming release of our software NX 10. This version is planned to be available for download from 23-Dec-2014.

1992587

Siemens PLM believes that the problem you reported where positioning and editing of additional text and symbols in GD&T-Symbols will be resolved by code changes made to the release of our product. The problem where the leader does not stay attached to the FCF when above appended text is added is fixed by a project in NX 10.

Note: for parts created in previous releases a drawing update will cause the leader attachment to move to the correct location.

1992612

Siemens PLM believes that the problem you reported where Synchronous modeling Feature causes PTS freeze will be resolved by code changes made to the upcoming release of our software NX 10.

1992619

Siemens PLM believes that the problem you reported where "Error in Refset content regarding Sketches" will be resolved by code changes made to the upcoming release of our software NX 10.

1992620

Siemens PLM believes that the problem you reported where "Reg_NX 7.5.4. Drawing views updated on an inactive drawing do not regenerate" will be resolved by code changes made to the release of our product NX 10. Workarounds in previous releases: The views have updated properly but the display is incorrect. 1) "Menu->View->Operation->Regenerate Work" will resolve the issue. OR 2) Save and re-open drawing.

1992714

Vehicle Design Automation - Mirror Certification.

1992816

Siemens PLM believes that the problem you reported where NX assembly cannot be loaded - Error: The same title cannot be used on two different will be resolved by code changes made to the upcoming release of our software NX 10. The problem mentioned in pr text is fixed and the fix would be available in NX 10 Also submitted fix to NX 8.5.3 MP3 HF, NX 8.5.3 MP and NX 9.0.3 MP.

1992907

Siemens PLM believes that the problem you reported where wrong translation "during the load of" will be resolved by code changes made to the release of our product NX version NX 10.

1992920

Siemens PLM believes that the performance issue you reported when using Smart Lightweight is due to:

1) Bad geometry imported during part translation

2) The Facet Brep generation code in NX did not handled the non-manifold case gracefully To fix 1) please regenerate the Jt data in NX refile_part -regen_lw -y -f -d <where the parts are located> and then create the Smart Smart Lightweight Views again. Point 2) will be resolved by code changes made to the upcoming release of our software NX 10.

1993087

Siemens PLM believes that the problem you reported where Performance issue with zoom in/out due to model feature Subtract will be resolved by code changes made to the upcoming release of our software NX 10.

1993096

Siemens PLM believes that the problem you reported where "Internal error: memory access violation occurred when one selects both unmapped components and maps existing afem" will be resolved by code changes made to the upcoming release of our software NX 10.

1993118

Siemens PLM believes that the problem you reported where Vehicle Design Automation: Windshield Vision Zones will be resolved by code changes made to the upcoming release of our software NX 10.

1993119

Siemens PLM believes that the problem you reported where Vehicle Design Automation: Windshield Vision Zones will be resolved by code changes made to the upcoming release of our software NX 10. The problem where the illustration graphics was not correct as per the European Standard is fixed in NX 10.

1993121

Siemens PLM believes that the problem you reported where the Option "File -> Import -> STL -> Facet Body Type" is not saved in Dialog Memory will be resolved by code changes made to the upcoming release of our software NX 10.

1993212

The alert information depends on the Parasolid tracking information and the resultant ps_tag. As for the intersection case where the tool body is completely inside the target body, none of the PS tag on the target body survives on the resultant body, all the PS tags on the resultant body are inherited from the tool, as well as the face label. It would be necessary for some customers to be informed of the condition. Maybe some customers do not think it is necessary. As for the wrong message order, it has been corrected in NX 10.

1993254

Siemens PLM believes that the problem you reported where "Transient components must not be automatically stored on file system" will be resolved by code changes made to the release of our product NX version NX 10 phase 21, and is a candidate for inclusion in a NX 9.0.3 MP.

1993271

Siemens PLM believes that the problem you reported where a Block UI Styler 'Drawing Area' block won't find a JPG image in an 'application' subfolder will be resolved by code changes made to the release of our product NX 10.

1993310

Siemens PLM believes that the problem you reported where FASC Contour Area operation does not cut all of the area will be resolved by code changes made to the release of our product NX 10 and has been submitted to a for a future MP release of NX 9.0.3. The problem is caused by the cut area containing undercuts w.r.t. to the tool axis and these by default are not machined. To enable the machining of these it will be necessary to set the ENV variable UGII_CAM_MACHINE_IN_REGION_UNDERCUT= 1.

1993381

Siemens PLM believes that the problem you reported where CAM: Own Collision Pairs inside NX 9.0.2 are not Saved after "OK" will be resolved by code changes made to the upcoming release of our software NX 9.0.3 MP1, NX 10.14.

1993415

Siemens PLM believes that the problem you reported where Spline update Issues 2 will be resolved by code changes made to the upcoming release of our software NX 10. The problem where coincident constraint is not inferred in edit of a sketch spline has been fixed in NX 10. Please note that continuity constraints are not captured for spline through-points during edit. Only G0 will be captured as a coincident constraint on edit.

1993420

Siemens PLM believes that the problem you reported where Section Surface - modeler error will be resolved by code changes made to the release of our product NX 10.

1993481

Siemens PLM believes that the problem you reported where Mirror Feature does not work on UDF will be resolved by code changes made to the release of our software NX 10.

1993487

Siemens PLM believes that the problem you reported where Cavity Mill creates Collision between IPW and Tool by using Lowest Z-Level will be resolved by code changes made to the release of our product NX .90.3 MP1.

1993510

Siemens PLM believes that the problem you reported where Project curve in modeling - reverse projection will be resolved by code changes made to the upcoming release of our software NX 10. The problem where project curve in modeling - reverse projection is fixed in release NX 10 IP18. The fix is version protected in NX 10. Hence, to test the fix please create a new project curve feature in NX 10.

1993537

Siemens PLM believes that the problem you reported where the blank XLS register form in ELECTRODE_DESIGN_DIR cannot be found without the XS4 file will be resolved by code changes made to the upcoming release of our software NX 10.

1993566

Siemens PLM believes that the problem you reported where Create constraint with drag & drop doesn't work correct "within active sketch only", will be resolved by code changes made to the upcoming release of our software NX 10.

1993588

Siemens PLM believes that the problem you reported where CreateDrawingEditViewSettingsBuilder only works with single member view array will be resolved by code changes made to the upcoming release of our software NX 10 by extending the NXOpen documentation. It will state the need for the ProcessForMutipleObjectsSettings API for multiple object settings. The correct steps are: - Create individual builder for all selected objects. For first builder (i.e. primary builder) pass all selected objects. For next builders (i.e. secondary builder), pass single object starting from 2nd selected object. - Call ProcessForMutipleObjectsSettings API on SettingsManager by passing all these above created edit settings builder. - Call InheritSettingsFromCustomerDefault on primary builder. - Call commit on each of these builder. - Call destroy on each of these builder. However, there is nothing wrong with the provided workaround by creating a single member view array instead for each Drafting View member:

 ------------- DraftingView[] allDraftingViews = workPart.DraftingViews.ToArray(); for (int ii=0; ii<allDraftingViews.Length; ii++) { View[] views1 = new View[1]; views1[0] = allDraftingViews[ii]; NXOpen.Drawings.EditViewSettingsBuilder editViewSettingsBuilder1; editViewSettingsBuilder1 = workPart.SettingsManager.CreateDrawingEditViewSettingsBuilder(views1); editViewSettingsBuilder1.InheritSettingsFromCustomerDefault(); NXObject nXObject1 = editViewSettingsBuilder1.Commit(); editViewSettingsBuilder1.Destroy(); lw.WriteLine("Updating view " + allDraftingViews[ii].ToString() ); allDraftingViews[ii].Update(); } -------------

1993746

Incorrect display of treaded hole on the multi-segment Section.

1994012

Siemens PLM believes that the problem you reported where Pattern feature very slow to generate will be resolved by code changes made to the upcoming release of our software NX 10.

1994058

Siemens PLM believes that the problem you reported with "Wrong Pendulum Profile for ECE-R42 Rotated-Front" will be resolved by code changes made to the upcoming release of our software NX 10.

1994063

Siemens PLM believes that the problem you reported where "Misbehavior deleting a linked-sketch object" will be resolved by code changes made to the upcoming release of our software NX 10.

1994135

Russian symbols displays as rubbish in the attribute "Component Name".

1994168

Siemens PLM believes that the problem you reported "Vehicle Design Automation: Cylinder positions of Close Range Visibility wrong" will be resolved by code changes made to the upcoming release of our software NX 10.

1994244

Siemens PLM believes that the problem you reported where Incorrect translation of Product of Inertia (Centroidal) on (GERMAN UI) will be resolved by code changes made to the release of our product NX 10.

1994304

Siemens PLM believes that the problem you reported where Misbehavior at Extracted Bodies in the Target Part will be resolved by code changes made to the release of our product NX 10. The problem where after relinker, the 3rd extract ("ExtractGEO") on the target part wrongly became "Linked Body" (interpart). This issue has been fixed in NX 9.0.2 D3 onwards. The other issues is with the PN OOD column reporting: the extracts should all be OOD is fixed in NX 10 with project work.

1994399

Siemens PLM believes that the problem you reported where the Business Item Type is not visible in NX when unique Teamcenter property is applied will be resolved by code changes made to the upcoming release of our software NX 10.

1994482

Siemens PLM believes that the problem you reported where NX 9 ugtopv - Geometry missing in PMI Model Views created with mergeSolids false will be resolved by code changes made to the release of our product. The problem where Geometry is missing in PMI Model Views created with mergeSolids false is fixed in release NX 10.

1994543

Siemens PLM believes that the problem you reported where Holetable with incorrect diameters will be resolved by code changes made to the upcoming release of our software NX 10.

1994704

Siemens PLM believes that the problem you reported where "Exact View behaves different to Exact (Pre NX 8.5) view concerning view dependent" will be resolved by code changes made to the release of our product NX 10. The problem where view dependent edits vanish when "Hidden Line" option is set to Invisible is fixed in NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them. A new procedure entitled "Display only view dependently edited hidden lines" is added to the Drafting Help that documents the process.

1994755

Siemens PLM believes that the problem you reported where Creation of Upper Roof crashes Head Impact feature will be resolved by code changes made to the upcoming release of our software NX 10.

1994785

The problem where the size of the angular dimension was incorrect in a smart lightweight view is fixed in NX 10. For exact views the dimension should be fixed immediately on part open. For smart lightweight views a view update is required.

1994815

Siemens PLM believes that the problem you reported where using the NXOpen method "NXOpen.Assemblies -> ComponentAssembly -> AddComponent()" in a renamed Sub Assembly puts the leaf component into a blanked state will be resolved by code changes made to the release of our product NX 10.

1994883

Siemens PLM believes that the problem you reported where you are unable to modify assigned Item ID during Save as > new item will be resolved by code changes made to the upcoming release of our software NX 10.

1994897

Siemens PLM believes that the problem you reported where Update of Detail View will delete Circular Pattern Features will be resolved by code changes made to the upcoming release of our software NX 10.

1994937

Siemens PLM believes that the problem you reported where Journal Automation fails on WEDM UDEs with "can not output code to find <JABL>: <UGS::UICOMPJA_list>" will be resolved by code changes made to the release of our product NX 10.

1995020

Siemens PLM believes that the problem you reported where a non-associative linked boolean tool body moves to layer 271 randomly will be resolved by code changes made to the release of our product NX 10. The tool body created by the slave linked body feature is now always hidden and moved to hidden layer 271.

1995092

Siemens PLM believes that the problem you reported where modeler error occurs with stepped section line after adding segment and then specifying the hinge vector is fixed as part of Section View Enhancement project and will be fixed in released version of NX 10. For NX 8.5 and NX 9 versions there is a workaround available for this issue which is to define Hinge Line prior specifying point for placing section line.

1995124

Siemens PLM believes that the problem you reported where "Internal error while using edit section in an assembly with JT component" will be resolved by code changes made to the release of our software NX 10. The other problem reported in Pr about not being able open Jt files is being tracked in a separate PR (7183469)

1995316

Siemens PLM believes that the problem you reported where Not editable Section Surface will be resolved by code changes made to the release of our product NX 10.

1995318

Siemens PLM believes that the problem you reported where "Part Cleanup run create timestamp problem" will be resolved by code changes made to the release of our product NX 10 phase 20.

1995319

Siemens PLM believes that the problem you reported where the Up to Date status of the Feature Groups are wrong displayed will be resolved by code changes made to the release of our product NX 10. This version is planned to be ready for customer download from 23.12.2014.

1995342

Siemens PLM believes that the problem you reported where the 'import immediately' option on the various forms associated with the 'results manipulation' functionality (envelope, combination, etc.) has been removed in NX 9.0.x will be resolved by code changes made to the upcoming release of our software NX 10.*** Below is an explanation as to why the 'import immediately' option was removed in NX 9.0.x. However, following customer feedback this option has been re-introduced in NX 10.In NX 9 the 'output' block of all four 'results manipulation' dialogs was modified. There were a few important usability changes made: 1 - the 'include model' option was removed and a '.unv' file is always imported with the fea model 2 - the 'import immediately' option was also removed: > for 'imported' results this option enabled the immediate loading of the newly created result file > for 'companion' results this option was used to unload and load the solution result Though it was not transparent to user, 'import immediately' meant unloading and then re-loading of the results. We wanted to avoid this because from NX 9 onwards we are creating 'graph' items that persist as long as the results are loaded. There are other entities too (like 'path' and 'seed'). There are 'postviews', 'annotation', etc. as well. We were not giving the user any warning and simply unloading the results (thus deleting all these transient objects). This was felt to be a usability issue, and hence the 'import immediately' option for 'companion' results was removed.

1995473

Siemens PLM believes that the problem you reported where: Ray traced studio editor sets wrong image size for units=mm will be resolved by code changes made to the release of our software NX 10.

1995875

Siemens PLM believes that the problem you reported where MOM_abort issued from a sub-post run crashes NX will be resolved by code changes made to the release of our product NX 10.

1996192

Siemens PLM believes that the problem you reported where Fatal error while extrude an isocline will be resolved by code changes made to the release of our product NX 10.

1996194

Siemens PLM believes that the problem you reported with a un-configured Transient Components become visible under certain circumstances will be resolved by code changes made to the release of our product. It has been resolved in NX 10 and is a candidate for an NX 9.0.3 MP.

1996244

Siemens PLM believes that the problem you reported where "PS27.1.116:Face Blend on mirrored geomtrie does not work" will be resolved by code changes made to the release of our product NX 10ip22.

1996317

Siemens PLM believes that the problem you reported where Load Options won't Restore "Latest Working" from Default will be resolved by code changes made to the release of our product NX 10.

1996353

Siemens PLM believes that the problem you reported where "Missing Lines and Error Message after CGM-Import in NX 8.5 - Regression to NX 7.5" will be resolved by code changes made to the release of our product NX 10. In addition fixes were submitted for consideration to include in a future NX 8.5.3 and NX 9.0.3 MP.

1996406

Siemens PLM believes that the problem you reported where it is not possible to see the custom item types with required properties in NX dialogs is fixed in the release NX 10.Starting from NX 10. NX now supports Items with required properties defined in Teamcenter without any special setting required.

1996409

Siemens PLM believes that the problem you reported where the GRIP statement FILE/PART fails in batch mode with 1545013 "Unable to file part" when 'Save JT Data' is turned on will be resolved by code changes made to the release of our product NX 10.

1996449

Siemens PLM believes that the problem where "strange text by drafting standard... - standard to load" will be fixed in NX 10.

1996482

Siemens PLM believes that the problem you reported where "Ansichtenabhängiges Bearbeiten funktioniert nicht mehr mit den neuen Ansichten" will be resolved by code changes made to the release of our product NX 10.The problem where view dependent edits vanish when "Hidden Line" option is set to Invisible is fixed in NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them. A new procedure entitled "Display only view dependently edited hidden lines" is added to the Drafting Help that documents the process.

1996491

Siemens PLM believes that the problem you reported where "an operation was attempted on an invalid or unsuitable OM object" error will be resolved by code changes made to the release of our product NX 10.

1996787

Siemens PLM believes that the problem you reported where Sketcher - Make Corner deletes tangent Constraint will be resolved by code changes made to the release of our product NX 10.

1997024

Siemens PLM believes that the problem you reported where "NX Laminate Dynamics executable crashes when computing Tsai-wu failure metrics" will be resolved by code changes made to the release of our product NX 10

1997048

Siemens PLM believes that the problem you reported where Results when using Single Segment tube are different from those in NX 7.5 will be resolved by code changes made to the release of our product NX 10.The Tube feature has been enhanced to produce better output for tangent curves for "single segment" output option. The swept surface of the Tube will terminate at the end of each discrete curve in the tangent-continuous path. Tube features created in NX 10 and later will have the new behavior; NX 9 and older features will continue to maintain their output geometry. However, these fixes are version-controlled for NX 10 and later features. They cannot be backported to NX 8.5 MP or NX 9 MP due to risks of regression and forward compatibility.

1997171

Save results in error "..errors importing assembly arrangement PLMXML documents.

1997480

Mirror Feature fails to work correctly.

1997500

Siemens PLM believes that the problem you reported where 'Insert row in hole table results in internal error' will be resolved by code changes made to the release of our product NX 10. Insert Rows/Column option is not supported on the hole table. The "Menu - Edit- Table - Insert" option for the hole table will be disabled.

1997750

Siemens PLM believes that the problem you reported where the Verify dialog adds an extra move before the Go Home move causing it to traverse through the part is fixed in NX 9.0.3 MP2 and NX 10.

1998096

Siemens PLM believes that the problem you reported where "Alignment Through Curves" will be resolved by code changes made to the release of our product NX 10 phase 22 with cp NX321363.

1998107

The problem where view dependent edits vanish when "Hidden Line" option is set to Invisible is fixed in NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them.

1998137

Siemens PLM believes that the problem you reported where " Exception thrown when Breaking Links " will be resolved by code changes made to the release of our product NX version 10.

1998190

The problem where NX Drafting Preferences "Apply to entire dimension" revert to enabled upon Apply has been investigated and the following has been found. If "Apply to entire dimension" toggle is ON then any changes in appended text color, font, width, height, gap factor, aspect ratio and line factor applies to entire dimension INSTANTLY, (without hitting Apply button). Whereas while launching dialog, if all appended, dimension, tolerance text settings are same then Apply to entire dimension toggle automatically gets turned on, else turned off. An example, user first make changes in text height from 3.5 to 8. As "Apply to entire dimension" toggle is ON, so this modified appended dimension text height applied to other dimension text i.e. Dimension Text, Tolerance Text height. Now if we turn off "Apply to entire dimension" toggle and say Apply. Preference dialog gets created with new modified settings. Here all dimension text settings are same for appended, dimension, tolerance text so "Apply to entire dimension" toggle gets turned on automatically. So it"s working as designed. If user wants to make only Appended Text height as 8, then he first need to turn off Apply to entire dimension toggle and then change height to 8, Apply on Preference dialog. Now you can check "Apply to entire dimension" toggle will be off and Appended text height is changed 8 whereas dimension, tolerance text height is still 3.5. In NX 10 documentation the following clarification have been made about "Apply to entire dimension": ------------------- "When set, any changes made to the color, font, width, height, gap factors and aspect ratio settings are immediately applied to all of the dimension text. You do not have to click the Apply button. If you only want to apply changes to the appended text for the dimension, you must clear this option first and then make your changes." -------------------

1998227

Siemens PLM believes that the problem you reported where Display of NX 9 hole table is reset to standard color if updating will be resolved by code changes made to the release of our product NX NX 10.

1998260

NX Assembly Arrangement Bug - PR2242198

1998584

Siemens PLM believes that the problem you reported where Profile list created from Ship Structure Manufacturing gives wrong output will be resolved by code changes made to the release of our product NX version 10. Character used as thousands separator defined in Windows for Norway is not NX standard character set (UTF8). Changed code to remove thousands separator from the numeric output to the Profile List. Fixed in NX 9.0.3 MP 2 and NX 10.

1998745

Siemens PLM believes that the problem you reported where measurement results in Animation are not up to date will be resolved by code changes made to the release of our product NX 10 and NX 9.0.3 patch.

1998779

Siemens PLM believes that the problem you reported where "Missing Flat Pattern geometry on DXF export" will be resolved by code changes made to the release of our product NX 10.

1998791

Siemens PLM believes that the problem you reported where Displayed "optimized Tool Axis" when License is missed but Documentation says it will not will be resolved by code changes made to the release of our product NX 10

1998947

Siemens PLM believes that the problem you reported where drafting thread curves are missing a transform and therefore incorrectly displayed in new exact, revolved section views is fixed in NX 10. This version is planned to be available for customer download from 23-Dec-2014.

1999035

The problem where Clone "edit existing assembly" internal error is fixed in release NX 10 and this is also fixed in NX 9.0.3MP.

1999293

Siemens PLM believes that the problem you reported with NX SheetMetal - Creating a Flange not possible because a edge can not be selected will be resolved by code changes made to the release of our product NX 10.

1999304

Siemens PLM believes that the problem you reported where "Exception is Thrown when performing SaveAs" will be resolved by code changes made to the release of our product NX 10.

1999569

Siemens PLM believes that the problem you reported where with multiple strip with Strip Layout in Progressive Die Wizard will be resolved by code changes made to the release of our product NX 10.

1999833

Siemens PLM believes that the problem you reported where "No install documentation for EasyFill" will be resolved by code changes made to the release of our product NX version 10.0 It can be found from Home -> CAD -> NX Analysis -> Molded Part Validation

2061795

Siemens PLM believes that the problem you reported where editing the Corner Radius of a Bend did not refer back to the imported Bend Table that was originally used to define the radius, will be resolved by code changes made to the upcoming release of our software NX 10.

2113647

Siemens PLM believes that the problem you reported where length and width problem in Relief Origin of 'Corner Point'/Rectangular Cutout is As Designed. Since the Rectangle shape does not have anything like a Centre point as defined for a Circle, the BendCenter/CornerPoint is mapped to the starting corner of the Rect. Cutout. The NX 10 documentation will be updated.

2114330

Siemens PLM believes that the problem you reported where manually inputting a long directory path in the Compare Runs dialog cannot be done, will be resolved by code changes made to the upcoming release of our software NX 10.

2114333

Siemens PLM believes that the problem you reported where a Corner Preference was not reflected in Assign Corner, will be resolved by code changes made to the upcoming release of our software NX 10.

2114336

Siemens PLM believes that the problem you reported where 'Flat Pattern Treatments' Preferences being over-written by 'NX Sheet Metal' Preferences will be resolved by code changes made to the upcoming release of our software NX 10.

2124248

Siemens PLM believes that the problem you reported where the output results for geometry moment of Section Inertia are not on the XY plane will be resolved by code changes made to the upcoming release of our software NX 10.

2130834

Display performance is low when drag dimension in flatpattern view.

2133338

Siemens PLM believes that the problem you reported where the Drafting, "Color Filter" was not reset via the Reset Filters icon, will be resolved by code changes made to the upcoming release of our software NX 10.

2135322

Siemens PLM believes that the problem you reported where Feature Playback fails in NX 7.0.1.6 at Offset Face(116) raising the error "Cannot a