PR |
Description |
112739 |
In NX 8.0.1 of UG, Updating component entities consecutively (changing part name and reference set) results in rm5061 error. 001 The assembly part, 112739a, contains a reference set SS-S2B1-BASIC that contains over 30000 members. When the first component, 112739b, is updated, it brings in more entities than the original component had because the reference set specified in the update is bigger. When this larger component is added to reference set SS-S2B1-BASIC in the assembly, the size of that reference set exceeds 32767, which is the maximum. Unfortunately, since a reference set of that size is not really useful, the code does not check for the maximum, and the integer count of members actually rolls over into a negative number. This will cause subsequent 010 operations on that reference set to fail. In this case the "subsequent operation" was the update of 112739c. This problem will go away in V10 as reference sets will be able to contain close to 4 billion members. To get around the problem for now, just delete the reference set SS-S2B1-BASIC and any other reference sets that may be that large. It seems unlikely that they would be useful, since I am not sure what sort of assembly part you would expect to merge sub assemblies of this size. i.e. 2 of them would overflow the entity count. If there are GRIP or User Function programs that automatically build a standard set of reference sets, you may want to have them check the part size first and not build a reference set containing everything if the entity count is close to 50% of capacity. This problem will not exist in NX10. |
134991 |
The references to laminated material properties of QUAD/4 elements in the GFEMFEA appendix of the GFEMPLUS manual have been removed. GFEMFEA does not support laminated material properties. This information was mistakenly included from the PATRAN PFEA manuals. The GFEMPLUS manual includes these changes in the V10 manual. |
136003 |
Fixed in phase 12 by Kevin Le |
137446 |
Origin statement in operations in metric parts no longer generate errors. When an ORIGIN & FROM are both active the ORIGIN is not output in its specified location in the post command sequence. Works as designed! When FROM is active, ORIGIN always proceeds the FROM regardless of post command order. Documentation will be clarified. |
138255 |
In Version 9.2 of UGTODMIS, the user will be able to enter more than 99 DATSET commands in a single DMIS program without causing asterisks to be written to the file. |
138516 |
The cavity milling processor will generate arcs to cut a cavity. These arcs are not generated by the arc fit option. A potential enhancement would be linear interpolation of arcs; the arcfit option does not change arcs into linear gotos. Once an arc is an arc, it stays an arc. |
138881 |
GPM no longer outputs Adjust codes if not programmed. |
140184 |
This problem has been fixed in the "supplemental" V10.0 GENMOD release that will shipped along with the official V10 cdrom release. This has been verified to work in the V10.1 release. |
142487 |
In V9 of UG, after performing a unite on two named groups, one group remains empty and is not deleted. This is being fixed in v10 with the new delete algorithm and a change in the link type for groups. Hence, when all members of a group are deleted, the group itself will be deleted. |
143592 |
Fixed in V10. |
144290 |
The declaration for MAT(12) has been changed to NUMBER in the V10.0 Grip Programming manual. |
145722 |
The RM11 error problem retrieving a part file into V9.1 is not fixed in V10. |
146203 |
Fixed in V10 Phase 12. |
147088 |
The built-in constant expressions have been deleted from the V10 manual. |
147193 |
Fixed in V10. |
148160 |
The problem with GFEMFEA BAR/2/7 elements has been corrected in V10.1. BAR/2/7 elements format without problems and can be used in GFEMFEA analysis. Verified by L. Cull NTS |
148165 |
This will be corrected on the next release of the document, which should be the V10 release. |
148788 |
Part surfaces converted from a blended solid face now machine correctly with Zigzag surface routine. |
152172 |
The problem with uf5910 giving bad values has been fixed for V10. |
152200 |
The problem of the incorrect cylindrical face direction vector is fixed in V10 ph12. |
152283 |
This problem has been fixed in UGII V10 phase 11. |
152365 |
Cavity milling now machines trimmed surfaces. |
152481 |
A collection of associated problems with ACS are fixed in V10.0 of the Unigraphics but await full testing. These problems consist of the ACS_MAS node dying when acsexec is run with more than 32 nodes logged into UG. Receiving incomprehensible characters in the last field of the ACS log fil and receiving no node names in some of the entries. The ACS log file ent were also wrapping around the screen when displayed to a window. The 'sho current usage' option of acsexec was also displaying incomprehensible characters. |
152779 |
The problem where dimensioning to the endpoints of arcs using the point sub-function menu and the extension line origin changes when the dimension is updated, has been fixed in UG V10. |
153018 |
All parametric spline surfaces are mapped to b-surfaces in v10. The b-surface is more accurate than the parametric spline surface and the points are on the surface within a tolerance of less than .000000001. So the problem has been corrected in v10. |
153179 |
The problem in UGConcepts where angled lines required extra constraints, has been fixed in UG V10. |
153223 |
The install script for Worldview (UG on-line documentation) has been upgra for UG v10.x. The install script will no longer abort if you have more than one CDROM mounted during the install. |
153454 |
The problem where a RM 33 error was encountered when attempting to edit a dimension has been fixed in UG V10. |
153769 |
Documentation of null part procedures has been enhanced in the V10.0 User Guide, Appendix H. |
153992 |
This problem was verified as fixed in V10.1. Topology Forces and Moments are know distributed to the nodes correctly. Verified by L. Cull. |
154454 |
The problem of a 3-D pattern not mirroring through a plane correctly is fixed in V10 ph 13B. Todd Stauder. |
154931 |
For V10 of Unigraphics, the spaceball will start up when UG is started from UGMENU using the vsbmod driver. The problem with the spaceball not starting unless X11 or vue was previously running has been resolved. The spaceball will correctly start in V10 as long as UG is started from UGMENU in either the console or a window. |
154954 |
The problem with DISPLAY CONTROL, Surface/Solid Display, Hidden Edge, not working with patterns has been addressed and fixed in V10 phase 13 of Unigraphics. |
155011 |
This PR has been fixed in V10 Phase 11. |
155084 |
In v9.1 eds_reset did not find multiple copies of the plot despoolers that were running. This would cause PQMGR to give a license limit exceeded when trying to restart multiple plot despoolers. The v10 despoole now have different names, and eds_reset now finds all of the plotters run. |
155585 |
The problem with some of the trimmed surfaces converting as only on the ed the surface will not grid and it only displays one sem, has been fixed in so that the surface is now inside the curve instead of on the curve. The surfaces grid and shade correctly. |
155690 |
The problem with leaders being attached to the wrong area of a GD&T symbol after relocating the origin has been fixed in UG V10. |
155755 |
Fixed by wayne sanders in v10 phase 11. I verified using my customer's acs sheet. It works with v10/phase 5/5 and v10/phase12c. |
158635 |
The problem has been found and will be fixed in v10. |
159179 |
Documentation for the IGES error 728 has been included in draft for the next release. |
159570 |
In the V10 Grip manual, the EDA &DKRED has been fixed. |
159640 |
The problem of Info returning the wrong information of angle between to parallel lines has been addressed and fixed in the next release of UG. |
159753 |
Editing of dimensions text and origin has changed in V10.0. I was unable to reproduce the problem in V10. I believe this problem has been corrected. T.Olsen 29 April 93. |
159828 |
SB_DISPLAY_ADDR is no longer used, and the check for it has been taken out of the ugii script. Thus this customer will no longer have to modify the files. |
159954 |
The problem where the silhouette of a cylinder could not be used as the horizontal/vertical attachment line of a GD&T symbol has been fixed in Unigraphics V10.0. |
159988 |
Fixed in V10. |
160009 |
Fixed ufx013. vaccaro 3 June 1993. |
161463 |
In the IGES preprocessor, when converting patterns to subfigures, the enti in the sub-figure are now being marked as dependent. |
161690 |
Acsexec/license exceed 10 did not show user usage. |
162263 |
Finl In v100 the subtypes will match the documentation in appendix a for c nics. |
162464 |
The problem with a view dependent surface edge curve causing the IGES translator to hang when view dependent is turned off in preprocessing option has been fixed in v10. |
163134 |
This problem of fixed axis surface contouring gouging has been fixed in V10. |
163135 |
In the V10.0 Grip manual, the arguments for &ATTVL have been corrected so that the data type is now listed last in the argument line. |
163224 |
This PR has been fixed in 12f for V10. |
163331 |
The V10.0 Grip manual has been changed as requested. On page 11-64, references to the entity list table in the appendix have been removed and the old V9.0 entity list table has been restored for the MASK command. |
163943 |
The problem whereby the intersection of two sheet solids produces an RM22 error has been fixed in the next release of UG. |
164278 |
The allowable entity type table for MASK has been corrected for the V10 Grip manual so that it matches the correct table used in V9. |
164559 |
The new ugii script in v10 will correctly work if the spaceball is installed. |
165855 |
Problem receiving "4 invalid pointer file in CSDATA" cross-sectioning multiple surfaces has been addressed and fixed in v10 phase 13 of Unigraphics. |
167241 |
The problem of 1 tag dead or invalid in delent has been addressed and fixed in the next phase og UG. |
167713 |
The problem with the IGES preprocessor hanging on a dimension when view dependent is turned off in preprocessing options has been fixed in v10. |
174416 |
Saving a CSYS that is coincident with the cs no longer has the effect of making the CSYS permanent, i.e. it can be moved deleted, etc. |
184560 |
This is CRR 184560 text: The Grip Intsec command for version 9.1.n and prior versions, required the specification of a tolerance value, if anything other than .001 was desired ( the default tolerance). The default tolerance was inappropriate for metric parts. This problem has been fixed in version 10.0 with the Global Approximation Tolerance Project. This project made available the PREFERENCES - MODELING - DISTANCE TOLERANCE to the user. This value can be set in Customer Defaults. It is also set based on part units. The GRIP INTSEC command will default to this value when no tolerance is specified. Doug Birch, NTS. |
1127621 |
Siemens PLM believes that the problem you reported where Thread from Extract does not update will be resolved by code changes made to the release of our product NX version 10. The problem where a copied thread feature on Extract body did not update after source got updated, when delete propagation is turned OFF, has been fixed in NX 10 Phase 20. |
1127899 |
Siemens PLM believes that the problem you reported where there is an Internal Error when performing a Routing Reuse Search Children operation will be resolved by code changes made to the release of our product NX 10. |
1128228 |
Siemens PLM believes that the problem you reported where will be resolved by code changes made to the release of our product NX version 10. Several changes were made to edge-face stitch in NX 10. On user supplied models ... 100 bodies reported in NX 9.0.3: 20 sec NX 10: 6 sec 200 bodies reported in NX 9.0.3: 2 min NX 10: 14 sec 300 bodies reported in NX 9.0.3: 6 min NX 10: 30 sec 400 bodies reported in NX 9.0.3: 13 min NX 10: 58 sec all bodies selected and search 0.2 and snap 0.1 was used for the test above. |
1128256 |
Siemens PLM believes that the problem you reported where saving a part with long string attribute containing XML tag leads to a bad performance will be resolved by code changes made to the release of our product NX 10. However, such attributes are not supported by the legacy User Function and the NX UI cannot hold strings of that length. |
1128285 |
Siemens PLM believes that the problem you reported where Transform path does not work as expected with NX 9 spline paths will be resolved by code changes made to the release of our product NX 10. The fix will also be included in the next possible maintenance packs for NX 9.0.2 and NX 9.0.3. |
1128436 |
Siemens PLM believes that the problem you reported where NX Routing Heal Path Method: YC ZC XC does not work properly will be resolved by code changes made to the release of our product NX 10. |
1128442 |
The issue of 'Drawing not properly Exported' is fixed NX 10. A fix has been available also in NX 9.0.3 MP3. |
1128556 |
Siemens PLM believes that the problem you reported where unable to edit deform feature will be resolved by code changes made to the release of our product NX version 10. This problem where internal error occurs upon selecting flex instantiation feature in part navigator is fixed in NX 10. From NX 10 onwards the part can be opened and corrupt feature can be deleted and recreated successfully. The customer's parts are repaired in NX 7.5.5 (repaired_parts.7z). please download here: http://download.industrysoftware.automation.siemens.com/special.php/returned/pr 1128556_repaired_parts-clean.7z |
1128576 |
Siemens PLM believes that the problem where the Limit/Fit tolerance specification is not available on the scene dialog for ASME/inch units is fixed in NX 10. This version is planned to be available for customer download from 23-Dec-2014. |
1128799 |
Siemens PLM believes that the problem you reported where Blend Miter causes Export to Trumpf Geo to fail will be resolved by code changes made to the release of our product NX 10. Note :To get this fix, user has to recreate Closed Corner features with Blend Miter in NX 10. It can be seen that Flat Pattern doesn't create extra lines and Export Flat Pattern to Trumpf Geo works fine. |
1128814 |
Siemens PLM believes that the problem you reported where Holetable not working as expected will be resolved by code changes made to the release of our product NX 10. Work Around: 1. User has set option to display "Two-Sided Holes". When this setting is ON Hole Table will display both sided holes. i.e viewing direction and back side of viewing direction. So all label that user think are at wrong position are actually pointing to holes which are back side viewing direction. If user change the setting to "One-Sided Hole" then all labels pointing to back side hole will go away. 2. If user change the setting to "One-Sided Hole" then it is observe that few holes are not identified. This problem is fix in NX 10. |
1129051 |
Siemens PLM believes that the problem you reported where Sketcher update failed with memory access violation will be resolved by code changes made to the release of our product NX version 10. The problem where user got an error for memory access violation while updating Extract Body feature after editing sketch, has been fixed in NX 10. |
1129384 |
Update status difference between NX 9 and NX 10. |
1129440 |
Siemens PLM believes that the problem you reported where Hole Table did not work correct will be resolved by code changes made to the release of our product NX version 10. There were 2 issues mentioned in this PR for NX 9.0.x release. 1. Issue#1 is where some holes are missing in the hole table. 2. Issue#2 is where some partial non-hole features are getting identified as 'through holes'.\240 Issue#1 is fixed in NX 10.0.0. Issue#2 is having work around. User need to go to settings -> Hole Filters -> Include Partial Angle = OFF. \240 This WA can be used by as sort term solution. Development team would like to investigate this issue further for the appropriate resolution. PR#7222241 is filed to track this issue#2. |
1129511 |
Siemens PLM believes that the problem you reported where Wrong Major Diameter is inherited from customized thd_metric.dat file will be resolved by code changes made to the release of our product NX 10. |
1129646 |
Siemens PLM believes that the problem you reported where Online-Doc does not say something about Turning Feeds&Speeds inside Machining Data will be resolved by code changes made to the release of our product UGDOC NX 10. |
1129894 |
Siemens PLM believes that the problem you reported where Insert Text From File not working for Note command in managed mode of NX 9.0.3 will be resolved by code changes made to the release of our product NX 10. |
1526918 |
Siemens PLM believes that the problem you reported where Feature Playback fails in NX 3 and NX 4 will be resolved by code changes made to the release of our product NX 10. |
1652936 |
Siemens PLM believes that the problem you reported where Feature Playback is successful in NX 2 but fails in NX 5 at Draft Body(25) raising the error "Invalid References. Try Isocline method" will be resolved by code changes made to the upcoming release of our software NX 10. |
1673996 |
Siemens PLM believes that the problem you reported where it is not possible to delete routing ports in this part file will be resolved by code changes made to the upcoming release of our software NX 10. |
1695644 |
Siemens PLM believes that the problem you reported where STEP files do not open in NX 6.0.1 will be resolved by code changes made to the upcoming release of our software NX 10. |
1700085 |
The problem where Analysis->Minimum Radius would sometimes not report a radius in a concave face and sometimes report a radius on a convex face has been fixed in NX 10. |
1701242 |
Siemens PLM believes that the problem you reported where a Step file fails to import into NX, will be resolved by code changes made to the upcoming release of our software NX 10. |
1715959 |
Siemens PLM believes that the problem you reported where with 2D Exchange, a full bolt circle display is not correct will be resolved by code changes made to the upcoming release of our software NX 10. |
1726548 |
Siemens PLM believes that the problem you reported where a Fatal Error is reported when translating to dxf will be resolved by code changes made to the upcoming release of our software NX 10. |
1729352 |
Siemens PLM believes that the problem you reported where the Routing Bill Of Materials overrode previously defined Edit Levels on an existing Parts List, will be resolved by code changes made to the upcoming release of our software NX 10. |
1735707 |
Siemens PLM believes that the problem you reported where importing a DWG file crashes NX and the DWG translator will be resolved by code changes made to the upcoming release of our software NX 10. |
1740842 |
The problem where the Assembly Structure was duplicated when a file contained Arrangements has been investigated and the following has been found. This PR has been reviewed by development. Due to the low priority of the problem and the length of time the current behavior has been in the system we do not intend to fix this PR. If the problem is still impacting your day to day operation as you use the NX product, please contact GTAC to have the PR reopened. A note was added to the Help content for Arrangements in drawings that explains that arrangement data is added to the drawing file when arrangements are used in a drawing. |
1745588 |
Siemens PLM believes that the problem you reported where double dimensions do not translate to dxf correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
1753286 |
Siemens PLM believes that the problem you reported where UGTO2D Centerlines of a Full Bolt Circle are extended to the circle center will be resolved by code changes made to the upcoming release of our software NX 10. |
1768204 |
"Attempt to write to freed object" if closing a part. |
1768293 |
Siemens PLM believes that the problem you reported where moving multiple components incorrectly displays position icons in the ANT will be resolved by code changes made to the release of our software NX 10. |
1781022 |
Siemens PLM believes that the problem you reported where updating the value for DB_PART_NAME in the Part Family Spreadsheet did not update the values in Teamcenter, nor the value in existing members, will be resolved by code changes made to the upcoming release of our software NX 10. |
1787572 |
Siemens PLM believes that the problem you reported where a Sketch fails when a sketch dimension is edited with Expression Editor, will be resolved by code changes made to the upcoming release of our software NX 10. |
1790291 |
Siemens PLM believes that the problem you reported where the 2D Exchange translator showed lines that were not shown in NX will be resolved by code changes made to the upcoming release of our software NX 10. |
1796920 |
Siemens PLM believes that the problem you reported where it is not possible to lock engagement and rotation of one port, will be resolved by code changes made to the upcoming release of our software NX 10. |
1807715 |
Siemens PLM believes that the problem you reported where information on internationalization on UNIX and MAC was incomplete or missing will be resolved by code changes made to the release of our product NX 10. |
1814328 |
Siemens PLM believes that the problem you reported where Update to End or automatic feature replay hides Alerts in Boolean operation will be resolved by code changes made to the upcoming release of our software NX 8. |
1819469 |
IPE is not update when using part family criteria. |
1828004 |
Siemens PLM believes that the problem you reported where section inertia calculation results are wrong for small circles will be resolved by code changes made to the upcoming release of our software NX 10. |
1832382 |
Siemens PLM believes that the problem you reported where updating a Section View reported: "Error: Modeler error: inconsistent arguments, or internal error", will be resolved by code changes made to the release of our product NX 10. |
1840213 |
Siemens PLM believes that the problem you reported where some menu items are not displayed correctly in French will be resolved by code changes made to the release of our product NX 10. |
1840921 |
Siemens PLM believes that the problem you reported where editing a path to add a point creates an explicit override in the assembly will be resolved by code changes made to the upcoming release of our software NX 10. |
1841754 |
Siemens PLM believes that the problem you reported where Electrical Replace Part Connector or Support will delete WAVE link of port will be resolved by code changes made to the upcoming release of our software NX 10. |
1842271 |
Siemens PLM believes that the problem you reported where adding Routing stock was not working in Teamcenter will be resolved by code changes made to the upcoming release of our software NX 10. |
1849472 |
Siemens PLM believes that the problem you reported where the German language menus display is not correct on MacOS will be resolved by code changes made to the release of our product NX 10. |
1849944 |
Siemens PLM believes that the problem you reported where Gaskets, inserted automatically between flanges, were not assigned an asserted weight as defined in their corresponding ptb, will be resolved by code changes made to the upcoming release of our software NX 10. |
1853993 |
Siemens PLM believes that the problem you reported where the Fix Length on Flex Pipes does not work any longer will be resolved by code changes made to the upcoming release of our software NX 10. |
1854793 |
Siemens PLM believes that the problem you reported where 2D exchange does not translate full bolt circles correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
1855558 |
Siemens PLM believes that the problem you reported where the Fix Length on Flex Pipes does not work any longer will be resolved by code changes made to the upcoming release of our software NX 10. |
1855662 |
Siemens PLM believes that the problem you reported where element size for 2D mapped meshes did not provide support for expressions will be resolved by code changes made to the upcoming release of our software NX 10. |
1857098 |
Siemens PLM believes that the problem you reported where saving an assembly raises the error "The function FCC_RollbackFileUploadedToPLM() returned the following status: Invalid ticket or invalid ticket pointer" will be resolved by code changes made to the upcoming release of our software NX 10. |
1857998 |
Siemens PLM believes that the problem you reported where updating the value for DB_PART_NAME in the part family spreadsheet does not update the values in Teamcenter, nor the value in existing members, will be resolved by code changes made to the upcoming release of our software NX 10.The issue has been resolved by giving user feedback in the form of a pop up message, mentioning the names of all locked attributes and the fact that they are locked, hence, their values cannot be updated. It will have the behavior as follows: 1. This message will pop up only once, whether one or multiple members are selected for update from the part family spreadsheet. 2. This message would pop up irrespective of whether the user tried to update the value of any locked attribute or not. 3. If the user tried to modify the value of locked attributes, their values are not undone (i.e. reverted back to the old value). Hence, the part family spreadsheet will get saved with the new value. The user should then change their values back to the previous value manually. This behavior is in line with Expressions attributes, where an expression value although invalid, gets saved in the spreadsheet. |
1859229 |
Siemens PLM believes that the problem you reported where the Help pages were not found in the UDF dialog from RL workflow will be resolved by code changes made to the upcoming release of our software NX 8.5. |
1860680 |
Siemens PLM believes that the problem you reported where Open Parasolid Multi-body parasolid makes multi-component will be resolved by code changes made to the release of our product NX Documentation Version 10. |
1860704 |
Siemens PLM believes that the problem you reported where the NX documentation did not explain the differences between Import Parasolid and Export Parasolid, will be resolved by code changes made to the release of our product NX 10. |
1862343 |
Siemens PLM believes that the problem you reported where Electrical Routing Sweep disappears after make change to Spline Path will be resolved by code changes made to the upcoming release of our software NX 10. |
1862595 |
Siemens PLM believes that the problem you reported where the Formboard performance degraded in NX 7.5.3 MP3 will be resolved by code changes made to the upcoming release of our software NX 10. |
1865107 |
Siemens PLM believes that the problem you reported where a DWG cannot be opened will be resolved by code changes made to the upcoming release of our software NX 10. |
1865371 |
Siemens PLM believes that the problem you reported where an "Internal error: invalid solid object tag" error was raised when updating a view, will be resolved by code changes made to the upcoming release of our software NX NX 10. |
1866525 |
Siemens PLM believes that the problem you reported where Incorrect advanced flange reforming after normal cutout is created will be resolved by code changes made to the upcoming release of our software NX 10. With NX 10, the issue has been fixed with the Unbend/Rebend commands using following steps: 1. Switch to NX Sheet Metal (Application->Sheet Metal) if not already. 2. Suppress or delete the Uniform, Normal Cutout and Reform features. 3. Convert to Sheet Metal, selecting the bend of Advanced Flange as the "Additional Geometries". 4. Unbend the advanced flange. 5. Apply the normal cutout across the bend. 6. Rebend the bend back to the folded status. |
1868863 |
Siemens PLM believes that the problem you reported where Deleting a non-associative line displays a "Pre Delete Notification" error message will be resolved by code changes made to the upcoming release of our software NX 10. |
1869259 |
Siemens PLM believes that the problem you reported where following a replace of a connector or a boot the routing B-Curve is not displayed for edit in the formboard will be resolved by code changes made to the upcoming release of our software NX 10. |
1869892 |
Siemens PLM believes that the problem you reported where Orient Branch to Vector only moves anticlockwise to align a vector will be resolved by code changes made to the upcoming release of our software NX 10. |
1870698 |
Siemens PLM believes that the problem you reported where Replace Component stops the Built In Path updating when Flip component is used will be resolved by code changes made to the upcoming release of our software NX 10. |
1871829 |
Siemens PLM believes that the problem you reported where the Orient Branch command fails to move the branch will be resolved by code changes made to the upcoming release of our software NX 10. |
1874283 |
Siemens PLM believes that the problem you reported where exporting a Flat Pattern as a GEO File using the Export Trumpf GEO File command failed with NX reporting: "Curve Topology is not valid. Loops must be closed.", will be resolved by code changes made to the upcoming release of our software NX 10. |
1874908 |
Siemens PLM believes that the problem you reported where linked bodies are still created after Create Interpart Link has been disabled will be resolved by code changes made to the upcoming release of our software NX 10. |
1875064 |
Siemens PLM believes that the problem you reported where "Routing -> Reuse Library -> select Piping part -> Search Children" raised an Internal error: memory access violation, will be resolved by code changes made to the upcoming release of our software NX 10. |
1875891 |
Siemens PLM believes that the problem you reported where inserting a Routing BOM caused the NX session to terminate having applied overstock, will be resolved by code changes made to the upcoming release of our software NX 10. |
1876149 |
Siemens PLM believes that the problem you reported where an assembly lost its Electrical Routing connections when loaded in one step, will be resolved by code changes made to the upcoming release of our software NX 10. |
1878353 |
Siemens PLM believes that the problem you reported where the GRIP command CRSEWV fails in gripbatch mode with error 671303 'No solids found' will be resolved by code changes made to the upcoming release of our software NX 10. |
1878931 |
Siemens PLM believes that the problem you reported where Create Interpart Link turns back on each time Spline Path dialog is opened will be resolved by code changes made to the upcoming release of our software NX 10. |
1880682 |
Siemens PLM believes that the problem you reported where the alignment of Text is not correct when DXF imported will be resolved by code changes made to the upcoming release of our software NX 10. |
1881421 |
Siemens PLM believes that the problem you reported where Measure Point Distance on Spline between two points was wrong, will be resolved by code changes made to the upcoming release of our software NX 10. |
1881480 |
Siemens PLM believes that the problem you reported where a T-boot flips on formboard update after replacing a connector will be resolved by code changes made to the upcoming release of our software NX 10. |
1881770 |
Siemens PLM believes that the problem you reported where Formboard Looses Geometry Changes Following Part Cleanup Delete Unused Objects will be resolved by code changes made to the upcoming release of our software NX 10. |
1882084 |
Siemens PLM believes that the problem you reported where Unable to Change Part Name with Part Family Spreadsheet will be resolved by code changes made to the upcoming release of our software NX 10. |
1884370 |
Siemens PLM believes that the problem you reported where the conversion of mating conditions in a specific assembly would fail will be resolved by code changes made to the upcoming release of our software NX 10. |
1884690 |
Siemens PLM believes that the problem you reported where a Draft feature lost a Blended Edge, or failed completely when changing a parent Extrude to various valid values, will be resolved by code changes made to the upcoming release of our software NX 10. |
1884903 |
Siemens PLM believes that the problem you reported where Export Trumpf Geo File failed reporting: "Curve topology is not valid. Loops must be closed.", will be resolved by code changes made to the upcoming release of our software NX 10. |
1885099 |
Siemens PLM believes that the problem you reported where it was unable to update section views after a geometry modification will be resolved by code changes made to the upcoming release of our software NX 10. |
1886169 |
Siemens PLM believes that the problem you reported where no constraints created when a connector is dragged from the Reuse Library will be resolved by code changes made to the upcoming release of our software NX 10. |
1886947 |
Siemens PLM believes that the problem you reported where information on internationalization on UNIX and MAC was incomplete or missing will be resolved by code changes made to the release of our product NX 10. |
1887680 |
Siemens PLM believes that the problem you reported where the "Create Terminals" loses the origin Routing Control Point will be resolved by code changes made to the upcoming release of our software NX 10. |
1888155 |
Siemens PLM believes that the problem you reported where editing a Routing curve resulted in connection being lost, will be resolved by code changes made to the upcoming release of our software NX 10. |
1889521 |
Siemens PLM believes that the problem you reported where the documentation was inadequate for the dimensions field in the UF_ASSEM_iset_array_data structure will be resolved by code changes made to the release of our software NX 10. |
1889737 |
Siemens PLM believes that the problem you reported where creating a new formboard drawing (electrical routing) the incorrect color palette is shown will be resolved by code changes made to the upcoming release of our software NX 10. |
1890831 |
Siemens PLM believes that the problem you reported where using Dynamic Axis while creating a Routing Path the Distance automatically snapped to "normal" value depending on the Zoom level, will be resolved by code changes made to the upcoming release of our software NX 10. |
1890885 |
Siemens PLM believes that the problem you reported where "Error adding Point to the Spline" message is given when creating Spline Path will be resolved by code changes made to the upcoming release of our software NX 10. |
1891283 |
Siemens PLM believes that the problem you reported Trim and Extend will be resolved by code changes made to the upcoming release of our software NX 10. However, to see the fix, the user will have to recreate Trim and Extend(62) with the value of 5mm rather than editing the existing Trim and Extend feature from 2mm to 5mm. |
1891553 |
Siemens PLM believes that the problem you reported where there was no feedback when the user tried to update the value of DB_PART_NAME will be resolved by code changes made to the upcoming release of our software NX 10. |
1892172 |
Siemens PLM believes that the problem you reported where placing an Altrep of a component places the original component in Routing. will be resolved by code changes made to the upcoming release of our software NX 10. |
1892483 |
Siemens PLM believes that the problem you reported where exporting PDF fails with last error message Teamcenter Error: Internal Error, will be resolved by code changes made to the upcoming release of our software NX 10. |
1893763 |
The problem where an NX to CATIA V5 translation resulted in missing geometry is fixed in the NX 10 and NX 9.0.3 CATIAV5 Translators. It will also be targeted for the MP's between NX versions 8.0.3 and 9.0.2. |
1895073 |
Siemens PLM believes that the problem you reported where a Face Blend parameter change is inconsistent will be resolved by code changes made to the upcoming release of our software NX 10. |
1895861 |
Siemens PLM believes that the problem you reported where Saving an assembly raised the error: "The function FCC_RollbackFileUploadedToPLM() returned the following status: Invalid ticket or invalid ticket pointer.", will be resolved by code changes made to the upcoming release of our software NX 10. |
1896058 |
Siemens PLM believes that the problem you reported where a Routing path is displayed as centerline instead of Simple Solid will be resolved by code changes made to the upcoming release of our software NX 10. |
1897549 |
Siemens PLM believes that the problem you reported where you are unable to Open Routing File (Error: Internal Memory Access Violation) will be resolved by code changes made to the upcoming release of our software NX 10. |
1897779 |
Siemens PLM believes that the problem you reported where Listing Window to File did not work properly will be resolved by code changes made to the upcoming release of our software NX 10. |
1898655 |
Siemens PLM believes that the problem you reported "PS27.0.50 ::Follow-up PR of DAG9335: blend face of Edge Blend(88) gone PR6687971" will be resolved by code changes made to the upcoming release of our software. This PR has been fixed in NX 10. In order to see the results the feature has to be created new. Just updating the old feature doesn't show you the desired output. |
1899507 |
Siemens PLM believes that the problem you reported where boolean unite failed due to alert thru face does not intersect will be resolved by code changes made to the upcoming release of our software NX 10. |
1899920 |
Siemens PLM believes that the problem you reported where JT files do not open to NX correctly will be resolved by code changes made to the release of our product NX 10. You will have to resave the Jt file in NX 10 for the Jt data to be written to part file correctly. |
1899936 |
Siemens PLM believes that the problem you reported where NX Part families : DB_PART_NAME do not update after changes in spreadsheet will be resolved by code changes made to the upcoming release of our software NX 10. |
1902248 |
Siemens PLM believes that the problem you reported where Analyze Formability returned wrong shapes, will be resolved by code changes made to the upcoming release of our software NX 10. |
1902263 |
Siemens PLM believes that the problem you reported where Auto Stitch is not successful, will be resolved by code changes made to the upcoming release of our software NX 10. |
1902449 |
Siemens PLM believes that the problem you reported where the feature side cannot be specified when it needs to be reversed while using the One-step-Formability will be resolved by code changes made to the upcoming release of our software NX 10. |
1903099 |
Siemens PLM believes that the problem you reported where it was not possible to add the Threads of a Threaded Hole applied to a Promoted Body to the Model Reference Set, will be resolved by code changes made to the upcoming release of our software NX 10. |
1903421 |
Siemens PLM believes that the problem you reported where a patter will not update a threaded hole correctly, will be resolved by code changes made to the upcoming release of our software NX 10. |
1904602 |
Siemens PLM believes that the problem you reported where UF_PLIST_list doesn't write to file device by uc4400 as of NX 8 will be resolved by code changes made to the release of our product NX 10. |
1904650 |
Siemens PLM believes that the problem you reported where an internal error was raised editing stock and changing to Transform Path dialog, will be resolved by code changes made to the upcoming release of our software NX 10. |
1904770 |
Siemens PLM believes that the problem you reported where the error "Expressions of Thread and Feature Diameters are out of sync" was raised when adding a symbolic thread, will be resolved by code changes made to the upcoming release of our software NX 10. |
1904804 |
Siemens PLM believes that the problem you reported where he Default browse folder was not retained when restarting NX will be resolved by code changes made to the upcoming release of our software NX 10. |
1905998 |
Siemens PLM believes that the problem you reported where a NXOpen Error "No automation class for tag: nnnnn, class: DesignRuleFunction" occurs for type/subtype UF_design_rule_type=188 and UF_design_rule_function_subtype=3 will be resolved by code changes made to the upcoming release of our software NX 10. |
1906012 |
Siemens PLM believes that the problem you reported where NX 6.0.5.3 Grooving operations generated in NX 7.5 no longer output the Delta move specified for the Start Point will be resolved by code changes made to the upcoming releases of our software NX 9.0.2 and NX 10. |
1906467 |
Siemens PLM believes that the problem you reported where there was an issue with setting the snap increment default on move command, will be resolved by code changes made to the upcoming release of our software NX 10. |
1906764 |
Siemens PLM believes that the problem you reported where "French language with non-ASCII characters are rejected when renaming objects in the Advanced Simulation" will be resolved by code changes made to the release of our product version NX 10. |
1906858 |
Siemens PLM believes that the problem you reported where "Turning : Stop position Point are Ignored in NX 7.5.5 and NX 8.0.2" will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10. |
1907779 |
Siemens PLM believes that the problem you reported where: Edit reusable component will not update the drawing dimensions accordingly will be resolved by code changes made to the release of our software NX 10. |
1907961 |
Siemens PLM believes that the problem you reported where Projected Curve (points) when inserting UDF raises: "Missing section string", will be resolved by code changes made to the upcoming release of our software NX 10. |
1908050 |
Siemens PLM believes that the problem you reported where an error, "The following links had their reference geometry consumed", occurs while updating links will be resolved by code changes made to the upcoming release of our software NX 10. |
1908235 |
Siemens PLM believes that the problem you reported where a Thickened Mirror Body was not uniform, will be resolved by code changes made to the upcoming release of our software NX 10. |
1908351 |
Siemens PLM believes that the problem you reported where exporting a Flat Pattern as a GEO File, using the Export Trumpf GEO File command, raised the error: "Curve Topology is not valid. Loops must be closed" and the export failed, will be resolved by code changes made to the upcoming release of our software NX 10. |
1909960 |
Siemens PLM believes that the problem you reported where there are Inconsistent Check-Mate Results for Examine Geometry will be resolved by code changes made to the release of our product NX 10. |
1910255 |
Siemens PLM believes that the problem you reported where Replace Deformable Cable in Routing uses all available memory will be resolved by code changes made to the upcoming release of our software NX 10. |
1910555 |
Siemens PLM believes that the problem you reported where an Internal error was raised when editing the size of Space Reservation, will be resolved by code changes made to the upcoming release of our software NX 10. |
1912087 |
Siemens PLM believes that the problem you reported where not all objects were placed on the Original layer when a UDF was added with the layer option set to "Original", will be resolved by code changes made to the upcoming release of our software NX 10. |
1912092 |
Siemens PLM believes that the problem you reported where Apply customer defaults to all menus will be resolved by code changes made to the upcoming release of our software NX 10. |
1913341 |
Siemens PLM believes that the problem you reported where "Tool class mapping table is incomplete/incorrect in NX documentation" will be fixed in NX 10. |
1914127 |
Siemens PLM believes that the problem you reported where NX takes too long to delete update pending meshes when edge matching is used will be resolved by code changes made to the upcoming release of our software NX version 10. |
1914357 |
Siemens PLM believes that the problem you reported where Checker %mqc_update_all_drawings is not working as documented will be resolved by code changes made to the upcoming release of our software NX 10.The documentation of Check-Mate function mqc_updateAllDrawings has been fixed in NX 10.0 to indicate whether all drawing objects can be regenerated correctly. The function is used by the Update All Drawings checker to report drawing objects which can not be regenerated correctly or are not constant before and after drawing view update. In the PR case, three annotation objects are not constant due to position changes after update. After the user updates all drawing views, the annotation objects are also updated in the drawing views. The Update All Drawings checker passes because these annotation objects have constant positions before and after the latest update. |
1915124 |
Siemens PLM believes that the problem you reported where xy function curves display as continuous lines, or part continuous/part discontinuous lines, even though the selected display line style is one of the discontinuous (dashed) line styles, will be resolved by code changes made to the upcoming release of our software NX 10. |
1915304 |
The problem where defining assembly constraints in this assembly could be slow is fixed in NX 10. Major improvements have been made in the performance from NX 6 to NX 8, and a typical operation on this assembly has been made four times faster still in NX 10. |
1915594 |
Siemens PLM believes that the problem you reported where No refresh of TC information in NX Mgr Title Bar and Windows-dropdown will be resolved by code changes made to the upcoming release of our software NX 10. The problem is fixed in NX 10 since: 1. The customer default "Show Item Name instead of Number" is no more valid. 2. NX now honors the item revision display name in Teamcenter which is the object_string property. So the display name in TC RAC My Navigator and NX would now be consistent. |
1916055 |
Siemens PLM believes that the problem you reported where Create Post Action on update Sheet/Drawing will be resolved by code changes made to the upcoming release of our software NX 10. |
1916357 |
Siemens PLM believes that the problem you reported where Placing Fitting results in conflicting constraint and remove part deletes RCP will be resolved by code changes made to the upcoming release of our software NX 10. |
1916729 |
Siemens PLM believes that the problem you reported where there is an incorrect NCM engage movement when using swing angle and 3D IPW will be resolved by code changes made to the upcoming release of our software NX 10. The swing angle in non-cutting moves will now be processed when using 3D IPW for surface contouring operations. |
1917390 |
Siemens PLM believes that the problem you reported where an error appears with load/delete component from assembly will be resolved by code changes made to the upcoming release of our software NX 10. |
1917799 |
Siemens PLM believes that the problem you reported where Sketch in view: edit-curve-stretch: no rectangle selection available will be resolved by code changes made to the release of our product NX 10. |
1919400 |
Siemens PLM believes that the problem you reported where mechanical routing loses associations to reference geometry will be resolved by code changes made to the upcoming release of our software. This PR is validated against ugnx7554_mp10 and found to be RESOLVED. This PR is validated against NX 10.0.0.8 and found to be RESOLVED. |
1919885 |
Siemens PLM believes that the problem you reported where the graphics display is not updated fully after changes to formboard layout branch angles, will be resolved by code changes made to the upcoming release of our software NX 10. |
1919926 |
Siemens PLM believes that the problem you reported where Additional Ports are created following formboard branch angle change will be resolved by code changes made to the upcoming release of our software NX 10. |
1919950 |
Siemens PLM believes that the problem you reported where additional RCPs are shown on the formboard following a branch angle change, will be resolved by code changes made to the upcoming release of our software NX 10. |
1920122 |
Siemens PLM believes that the problem you reported where the Blockstyler ListBox 'ShowAddButton' property shows the button in a wrong location when called in the Update cb will be resolved by code changes made to the upcoming release of our software NX 10. |
1920160 |
Siemens PLM believes that the problem you reported where Routing Mechanical - Stock component folder in Teamcenter not populated will be resolved by code changes made to the upcoming release of our software NX 10 and all subsequent releases. |
1920196 |
Siemens PLM believes that the problem you reported where Setting the ListBox properties "SingleSelect" and "MaximumStringLength" works in Initialize cb only will be resolved by code changes made to the documentation of our software NX 10. The Block UI Styler List Box block documentation was incorrect and has been updated for those properties to state now the correct access "CIG" (Creation/Initialize/Set). |
1920336 |
Siemens PLM believes that the problem you reported where Visualize shows two entries for some circular contact contour motions in the list view will be resolved by code changes made to the upcoming release of our software NX 9.0.3 |
1920815 |
Siemens PLM believes that the problem you reported where Three bend corner does not work on 90 degree bends will be resolved by code changes made to the upcoming release of our software NX 10. |
1921157 |
Siemens PLM believes that the problem you reported where Circular update Error after changing Distance Constrains for Spun Outline will be resolved by code changes made to the upcoming release of our software NX 10. |
1922693 |
Siemens PLM believes that the problem you reported where "Pipe does not get Cut when Inserting multiple Comp" will be resolved by code changes made to the upcoming release of our software NX 10.0.0.8. This PR is validated against NX 7.5.5.4 (ugmenu) and found to be REPRODUCIBLE. This PR is validated against NX 10.0.0.8 as a part of PR cleaning activity and found to be RESOLVED. Hence, closing this PR as FX. |
1922771 |
PSv27.0.51 FaceBlend -> Overriding Trim Objects on sheets not working. |
1922788 |
Siemens PLM believes that the problem you reported where "open file" fails with Internal Error, will be resolved by code changes made to the upcoming release of our software NX 10. |
1922867 |
Siemens PLM believes that the problem you reported where NX 8: WCS Axis handles can't be selected will be resolved by code changes made to the upcoming release of our software NX 10. |
1922877 |
(PS27.00.041) Thicken of a Sheet Body is inconsistent. |
1923522 |
Siemens PLM believes that the problem you reported where slope analysis displays incorrectly in assembly context will be resolved by code changes made to the upcoming release of our software NX 10. |
1924422 |
Siemens PLM believes that the problem you reported where Pattern->Retrieve Pattern will cause Internal error will be resolved by code changes made to the upcoming release of our software NX 10. You have to save the part file containing the pattern in NX 10 to update the part so that the change can take effect. |
1924481 |
Siemens PLM believes that the problem you reported where File->Export->2D Exchange delivers a result where arcs have the "wrong" direction will be resolved by code changes made to the upcoming release of our software NX 10. |
1925233 |
Siemens PLM believes that the problem you reported where Documentation for new Chamfer and Spherical Mill is missing will be resolved by code changes made to the upcoming release of our software NX 10 |
1925610 |
Siemens PLM believes that the problem you reported where a Routing control point does not follow the mouse will be resolved by code changes made to the upcoming release of our software. This PR is validated against NX 10. |
1926409 |
Siemens PLM believes that the problem you reported where Save part raises an error will be resolved by code changes made to the upcoming release of our software NX 10. |
1928836 |
Siemens PLM believes that the problem you reported where SMD- SB- Closed Corner failed will be resolved by code changes made to the upcoming release of our software NX 10. |
1929341 |
Siemens PLM believes that the problem you reported where you were Unable to Orient Specific Branches in Formboard will be resolved by code changes made to the upcoming release of our software NX 10. |
1929373 |
Siemens PLM believes that the problem you reported where Orient branch fails in formboard will be resolved by code changes made to the upcoming release of our software NX 10. |
1929804 |
Siemens PLM believes that the problem you reported where "the Stress Wizard legend may be partially clipped" will be resolved by code changes made to the release of our product NX 10. |
1929968 |
Siemens PLM believes that the problem you reported with a wrong positioned component after JT import will be resolved by code changes made to the release of our product. The problem where the components of a particular JT assembly file are not in the appropriate location has been fixed in NX 8.0.1. For some unknown reason that same fix did not carry over into the NX 8.5, NX 9 releases, but the fix is definitely in NX 10. |
1930095 |
Siemens PLM believes that the problem you reported where Ribbon Builder - Icon wrong will be resolved by code changes made to the upcoming release of our software NX 10.0.0.12 |
1930943 |
Siemens PLM believes that the problem you reported where Formboard with 0 discrepancies in NX 7.5.3 has many discrepancies in later versions will be resolved by code changes made to the upcoming release of our software NX 10.In this version the formboard shows zero discrepancies. |
1931007 |
Siemens PLM believes that the problem you reported where creating a Bounded Plane with outer and inner loop fails with "Unable to reference edge" will be resolved by code changes made to the upcoming release of our software NX 10. |
1931040 |
The problem where NX doesn't update a datum plane after editing its associated parent is fixed in release NX 10. |
1931287 |
Siemens PLM believes that the problem you reported where Suppressed Toolpath is not continuously stored inside NX (Reply and Verify shows him ; Listing and Post not) will be resolved by code changes made to the upcoming release of our software NX 9.0.3. |
1931395 |
Siemens PLM believes that the problem you reported with Delete Face mismatch between Surface and Solid will be resolved by code changes made to the upcoming release of our software. From NX 10, a new delete face type "Blend" is developed, lots of blends on sheet can be deleted successfully with this type. If needed, user can optimize (with optimize face command) input body firstly to improve the face deletion rate. |
1931905 |
Siemens PLM believes that the problem you reported where Part Cleanup Deactivate UDE for In Path Events will be resolved by code changes made to the upcoming release of our software NX 10. |
1932869 |
Siemens PLM believes that the problem you reported where Preview display of cable splits when using Spline Path to move RCP will be resolved by code changes made to the upcoming release of our software NX 10. |
1932967 |
Siemens PLM believes that the problem you reported where User interface Contact Parameters needs percentage input, not factor input will be resolved by code changes made to the upcoming release of our software NX 10. |
1933218 |
Siemens PLM believes that the problem you reported where the NX 8.5 NXOpen documentation refers to an invalid method "Session.GetEnvironmentVariable" will be resolved by code changes made to the upcoming release of our software NX 10. |
1933456 |
Siemens PLM believes that the problem you reported where Unroute function very slow performance will be resolved by code changes made to the upcoming release of our software NX 10. |
1934757 |
Siemens PLM believes that the problem you reported where Crosshatch boundary curves do not highlight during editing, will be resolved by code changes made to the upcoming release of our software NX 10. |
1935054 |
Siemens PLM believes that the problem you reported where Connector part will flip during move part when there are multiple routing paths will be resolved by code changes made to the upcoming release of our software NX 10. |
1935197 |
Siemens PLM believes that the problem you reported where using the KF UI component ui_comp_angular_dim the Radius value of the handle is not scaling correctly will be resolved by code changes made to the release of our product NX 10. |
1935335 |
Siemens PLM believes that the problem you reported where update_fam_from_ptb fails when using -pim=yes will be resolved by code changes made to the upcoming release of our software NX 10. |
1935810 |
Siemens PLM believes that the problem you reported where Sketch shows Fully Constrained even after driving dimension is removed will be resolved by code changes made to the upcoming release of our software NX 10. |
1936116 |
Siemens PLM believes that the problem you reported where deviation gauge - wrong result will be resolved by code changes made to the upcoming release of our software. The problem is fixed in NX 10. |
1936145 |
Siemens PLM believes that the problem you reported where No dataset is created when creating constraints, after adding pending components, will be resolved by code changes made to the upcoming release of our software NX 10.The issue where the dataset is not saved after constraint creation is fixed in NX 10.Also a simple workaround for this is to simply do a "save" prior to creating the constraint in NX. An alternative workaround is to set the customer default "add NX dataset" to "always". |
1936244 |
Siemens PLM believes that the problem you reported where Internal Error with PTS UI in NX 8.5 will be resolved by code changes made to the upcoming release of our software NX 10. It looks like the primary problem was that the spreadsheet for one of the expressions was not being found. I think a part of that issue is that we should not have evaluated the expression as the part is opening in PTS. That has been fixed previously in NX 9 and NX 10. A second issue is how errors are being processed from a KF/Comp dialog, which has also been previously addressed in NX 9 and NX 10. There is also an issue with opening this part in NX 10, where the simulation parts have been renamed and not re-authored in PTS. The NX 10 version of PTS was not able to find the simulation with the part getting renamed - and that is now fixed. |
1936311 |
Siemens PLM believes that the problem you reported where "Incorrect NCM engage movement when using swing angle and 3D IPW" will be resolved by code changes made to the upcoming release of our software NX 10. |
1936715 |
Siemens PLM believes that the problem you reported where the UDF edit dialog had wrong boolean value selected, will be resolved by code changes made to the upcoming release of our software NX 10. |
1936951 |
Siemens PLM believes that the problem you reported where Linked body feature is not updated opening assembly with interpart data loaded will be resolved by code changes made to the upcoming release of our software NX 8.5.3. |
1937382 |
Siemens PLM believes that the problem you reported where Increase the Multi-Segment Bends in the Lofted Flange feature will be resolved by code changes made to the upcoming release of our software NX 10. |
1937569 |
Siemens PLM believes that the problem you reported where "Mirror Feature fails when sketch points positioned by positioning dimensions" will be resolved by code changes made to the upcoming release of our software NX 10. |
1937979 |
Siemens PLM believes that the problem you reported where "Extract Body causes Face Blend error" will be resolved by code changes made to the upcoming release of our software NX 10. |
1937993 |
Siemens PLM believes that the problem you reported where macro execution fails on Linux platforms if the macro tries to load a file with spaces in path will be resolved by code changes made to the upcoming release of our software NX 10. |
1938361 |
Siemens PLM believes that the problem you reported where Microposition in Curve on Surface does not work as it should will be resolved by code changes made to the upcoming release of our software. Siemens PLM believes that the problem you reported where microposition in curve on surface does not work as it should will be resolved by code changes made to the upcoming release of our software NX 9. |
1938638 |
Siemens PLM believes that the problem you reported with the documentation of microposition in Curve on Surface is incorrect / incomplete will be resolved by code changes made to the upcoming release of our software. This problem is fixed in NX 9.0 and later. Rewrote the text for the Rate option under Micropositioning: Lets you specify the relative amount of movement required to drag a handle in order to move the corresponding constraint point. This is especially useful for very fine curve point editing. Select the Rate box and specify a value between 0.01% and 100%. Lower values produce finer constraint point movement. You must press and hold the Alt key as you drag a constraint point handle to enable the Micropositioning rate. Note Pressing and holding the Alt key as you drag constraint points also disables Snap Point. |
1939422 |
Siemens PLM believes that the problem you reported where "Solid Body causes error with Face Blend" will be resolved by code changes made to the upcoming release of our software NX 10 Note that Face Blend dialog has gone through some enhancements in NX 10 IP10. |
1939424 |
Siemens PLM believes that the problem you reported where Variable Face Blend causes bad data quality will be resolved by code changes made to the upcoming release of our software NX 10. |
1939905 |
Siemens PLM believes that the problem you reported where the online help for udf's is not working will be resolved by code changes made to the upcoming release of our software NX 10. |
1939923 |
Siemens PLM believes that the problem you reported where the display of the MCD sequence editor was wrong will be resolved by code changes made to the upcoming release of our software NX 10. |
1940230 |
Siemens PLM believes that the problem you reported where Offset Face creates self-intersection will be resolved by code changes made to the upcoming release of our software NX 10. |
1940286 |
Siemens PLM believes that the problem you reported where Move Customer Symbols/Symbols takes a long time will be resolved by code changes made to the upcoming release of our software NX 10. |
1941152 |
Siemens PLM believes that the problem you reported where, when creating a point, the Point Type changes to Cursor Location when the Associative toggle is unchecked, will be resolved by code changes made in the NX 10 release. The behaviour will be modified so that when the Point Type is something other than Inferred, and no geometry has been selected, changing the Associative toggle will not change the type. |
1941410 |
Siemens PLM believes that the problem you reported where Face Blend fails at easy geometry will be resolved by code changes made to the upcoming release of our software NX 10. |
1941885 |
Siemens PLM believes that the problem you reported where Trumpf Geo Export fails - Curve topology is not valid. Loops must be closed, will be resolved by code changes made to the upcoming release of our software NX 10. |
1943501 |
Siemens PLM believes that the problem you reported where the NXOpen method DraftingViewCollection.UpdateViews(DraftingViewCollection.ViewUpdateOption.All) doesn't update one specific member view will be resolved by code changes made to the upcoming release of our software NX 10. |
1943662 |
The problem where some notes end up referencing a wrong attribute has been fixed in release NX 8.5.3. To prevent this from happening, the system will now generate an error when an application attempts to set wrong references to attributes. Unfortunately, this fix will not clean up old parts with this problem. If such cleanup is necessary (due to a large number of parts), please submit a new PR to Drafting. The problem where in some cases, references by annotations to PDM-based attributes have gone away has been fixed in release NX 10. The fix is also backported to previous releases. Loading the part in question, running the part fixup (no selections needed) and saving the part should fix the references. |
1943979 |
Siemens PLM believes that the problem you reported where the NX Open Programmers Guide contains an obsolete link to "How NX finds application files" will be resolved by code changes made to the upcoming release of our software NX 10. |
1944211 |
Siemens PLM believes that the problem you reported with No Thread Information on Pattern Feature with Extracted Bodies will be resolved by code changes made to the upcoming release of our software NX 10.With this change, Symbolic threads are inherited from extracts when participating in Pattern in both simple and variational methods. |
1944611 |
Siemens PLM believes that the problem you reported where KF Applications UI becomes grayed out with faulty %ui_comp class definition will be resolved by code changes made to the release of our product NX 10. The problem where the error "Invalid User Dialog" is displayed after pressing escape is by design. The KF uicomp classes can generate errors that are only detectable during the display of the dialog. However, the problem where the example in the documentation needs to be modified has been fixed. |
1944731 |
Siemens PLM believes that the problem you reported where there is an error closing parts after Auto Route operation has failed, will be resolved by code changes made to the upcoming release of our software NX 10. |
1945065 |
The problem where PTS String Item shows wrong List of Choices once modified in NX 8.5 has been investigated and the following has been found. model_GEO1: This is a problem where there are two widgets for Variant trying to show the value of the same expression in NX where one is visible and one is invisible at any given time. When widget 1 changes the value, then widget 2 is not in sync. When it becomes visible it is not showing the correct value and does not run through update to get the dialog rebuilt. It would be a fairly significant enhancement for PTS to recognize when a dialog contains two widgets driving the same variable and try to generate code to keep them in sync and get the dialog to update properly. Workaround: The alternative is to use list expressions for Variant and also the Laenge, Breite, and Hoehe lists since they are dynamic. So you would make two list expressions in NX for the list of choices for Variente. List 1, Variant_A, would contain {"Bitte_waelhen", "1", "2"} and a second list, Variant_B, would contain {"Bitte_waelhen", "3", "4"}. Then I made a selector, Variant_choices, with an if statement if ( Typ = "A" ) then Variant_A else Variant_B The expression Vairant_choices is then used with the list expression for Variant in the PTS dialog. The option for Allow the list content to change dynamically is clicked on. You then have one group for Laenge, Breite and Hoehe which will be visible when Variant is not Bitte_waelhen. There will be several list expressions for Laenge, Breite and Hoehe to allow for the various values of Variant. That gets close, but then the NX variables don't change to match up with the content of the lists, which means it is hard to follow. Since NX 8.5 will add the current value to the list the dialog shows the current values, but those values are not appropriate for the settings. What I think the intent with having "Bitte_waehlen" in the list is to make this the current value when the type or variant changes. I made visual rules to do this in PTS. Now when you change Type, then Variant becomes "Bitte_waehlen" and the group for laenge, Breite and Hoehe becomes invisible until Variant is selected. I uploaded this part, model_GEO1_lists.prt, to the PR data page. Finally: For NX 10, we added a new option where you can restore the old behavior of not adding the current value to the list of options. The list of choices will then work just like it did in NX 7.5. Since this requires a new translated field it is not something you can do in all releases. Also, as a bit of a workaround - if you have the lists return the index instead of the indexed value it does not add the current value to the list. That does require a slight change in the expressions to add a index value and then set the real expression from the index in NX, but it would avoid the new behavior. |
1945305 |
Siemens PLM believes that the problem with finding the proper inflection point on the curve for distance measurement will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014. |
1945653 |
Siemens PLM believes that the problem you reported where "the MB3 on tree list item displays incorrect context menu" will be resolved by code changes made to the upcoming release of our software NX 10. |
1945952 |
Siemens PLM believes that the problem you reported where Section view problems after edit expression in modeling will be resolved by code changes made to the upcoming release of our software NX 10. |
1946438 |
Siemens PLM believes that the problem you reported where Ownership of infodba Home folder influences NX will be resolved by code changes made to the upcoming release of our software NX 10. |
1946576 |
Siemens PLM believes that the problem you reported where "Error message appear closing parts with electrical routing objects". will be resolved by code changes made to the upcoming release of our software NX 10. |
1946706 |
Siemens PLM believes that the problem you reported where returning non-zero in Blockstyler OK callback shows unexpected error message will be resolved by code changes made to the upcoming release of our software NX 10. The new message displayed if the return value is other than 0 or 1 now is "Only 0 or 1 should be returned from OK, Apply, and Close callbacks. All non-zero return values will be converted to 1." |
1946745 |
Siemens PLM believes that the problem you reported with a playback error on edge blend nr1 will be resolved by code changes made to the upcoming release of our software NX 10. Verified to work in NX 10 with the new parasolid version 27.0.102. However, this blend needs to be deleted and recreated in nx10 to get the proper timestamp so that the correct software is used. Parasolid states this change cannot be backport to previous NX versions. |
1946839 |
Siemens PLM believes that the problem you reported where Automatic Spun-Outline for Partgeometry does not work will be resolved by code changes made to the upcoming release of our software NX 10. |
1947151 |
Siemens PLM believes that the problem you reported where edges edited by View Dependent Edit disappear when Hidden Lines set to Invisible, will be resolved by code changes made to the release of our product NX 10. The procedure is documented in an article entitled "Display only view dependently edited hidden lines" within the NX Drafting Help. |
1947224 |
The problem where Feature Update Failed has been investigated and the following has been found. The failing feature in the given part has been fixed in NX901. As this fix has been version protected new feature has to be created in the place of old one to see the fix. The old one continues to fail. Repaired Part can be download here: http://download.industrysoftware.automation.siemens.com/special.php/returned/19 47224_RepairedPart-clean.7z |
1947371 |
Siemens PLM believes that the problem you reported where the Dimension on hole datum symbol is incorrect (Custom Symbol) will be resolved by code changes made to the upcoming release of our software NX 10. |
1947512 |
The problem where "result files cannot be deleted after NX Nastran job fails" has been investigated and the following has been found: We are closing this problem report for now, because we cannot duplicate this and have not heard back from you about a video showing the problem. We will reopen it, once we get a video showing the issue. |
1947535 |
Siemens PLM believes that the problem you reported where there are Extra RCPs found during formboard update and no discrepancies in NX 7.5.3 MP5 will be resolved by code changes made to the upcoming release of our software NX 10. |
1947807 |
Siemens PLM believes that the problem you reported where a part cannot be opened using NX 7.5 will be resolved by code changes made to the upcoming release of our software NX 10. Furthermore the provided part has been repaired and provided to the customer. |
1947860 |
Problem where Internal error: memory access violation (11) by load from tc fixed in NX 10. Now part will get opened properly but user need to do part cleanup once part opened. |
1948130 |
The problem where poor performances and other inconsistencies are observed with Broken Views on large assemblies is fixed in NX 10. |
1948402 |
Siemens PLM believes that the problem you reported where Overstock cannot be used correctly without other routing nodes present will be resolved by code changes made to the release of our product NX 10. |
1948558 |
Siemens PLM believes that the problem you reported where the UFWrapper AskBreakoutData fails with SafeArrayTypeMismatchException will be resolved by code changes made to the upcoming release of our software NX 10. |
1948914 |
Siemens PLM believes that the problem you reported where the NXOpen method DraftingCustomSymbolBuilder.GetArbitraryNoteTitle() doesn't return any strings will be resolved by code changes made to the release of our product NX 10 by extending the documentation. |
1948971 |
Siemens PLM believes that the problem you reported where "plot thickness contours command on a given group of shell elements is not possible" will be resolved by code changes made to the upcoming release of our software NX 10. |
1949159 |
Siemens PLM believes that the problem you reported with "Inconsistent Drafted Boss" will be resolved by code changes made to the upcoming release of our software NX 10. |
1949213 |
UGMGR: Unable to open Assembly - *NX_Nav_.plmxml - Part is not currently loaded |
1949305 |
Siemens PLM believes that the problem you reported where the edit section line toolbar button is not working will be resolved by code changes made to the upcoming release of our software. The problem where edit section line toolbar button not working is fixed in release NX 10. |
1949406 |
Siemens PLM believes that the problem you reported where Draft do not updated correctly from NX6 to NX 8.5 will be resolved by code changes made to the upcoming release of our software NX 10. (The culprit features draft(21) and draft(22) needs to recreate in the NX 10 to get the correct result.) |
1949592 |
Siemens PLM believes that the problem you reported where UF_ASSEM_create_ref_set allows to create an "ENTIRE PART" Reference Set will be resolved by code changes made to the upcoming release of our software NX 10. |
1949894 |
Siemens PLM believes that the problem you reported where the documentation needs to explain how to pass arguments to Journals from Menuscript will be resolved by code changes made to the upcoming release of our software NX 10. |
1949922 |
Siemens PLM believes that the problem you reported where "Redefine Hinge Line is not able to select Center point" will be resolved by code changes made to the upcoming release of our software NX 10. |
1949955 |
Siemens PLM believes that the problem you reported where Combo String ListItems from a parent SetList block cannot be populated will be resolved by code changes made to the upcoming release of our software NX 10. |
1949978 |
Siemens PLM believes that the problem you reported where NX crashed after editing a sketcher will be resolved by code changes made to the upcoming release of our software NX 10. |
1950095 |
Siemens PLM believes that the problem you reported where Unable to add a additional flange will be resolved by code changes made to the upcoming release of our Software NX 10. |
1950102 |
Siemens PLM believes that the problem you reported where unable to attached a flange on an arbitrary edge will be resolved by code changes made to the upcoming release of our software NX 10. |
1950324 |
Siemens PLM believes that the problem you reported where Section line looses model associatively will be resolved by code changes made to the upcoming release of our software NX 10. |
1950331 |
Siemens PLM believes that the problem you reported where Updating a parent view hides a Detail View Label if 'Delay View Update' is turned off will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 0. |
1950451 |
Siemens PLM believes that the problem you reported where "Mac OS: Italian language font problem" will be resolved by code changes made to the release of our product NX 10. |
1950648 |
Siemens PLM believes that the problem you reported where Override position for ref-only parts fails when edits made in Structure Manager, will be resolved by code changes made to the upcoming release of our software NX 10. The problem where a position override in NX could be deleted on load if that override was associated with a reference-only component has been fixed. The fix will appear in the release version of NX 10. |
1950745 |
Siemens PLM believes that the problem you reported where NX 8.5 exports part attributes only to the parts parent assembly will be resolved by code changes made to the upcoming release of our software NX 10. |
1950904 |
Siemens PLM believes that the problem you reported where "Milling Workpiece has never been supported for creating a spun outline in a Turning workpiece group" will be resolved by code changes made to the upcoming release of our software NX 10.. A note stating the softwares intention of spun blank has been added to this section of TDOC (technical documentation). |
1951072 |
Siemens PLM believes that the problem you reported where the sketch doesn't change the view orientation after reattach will be resolved by code changes made to the upcoming release of our software NX 10. |
1951087 |
Siemens PLM believes that the problem you reported where you could not open a Routing part: Null pointer supplied to Routing will be resolved by code changes made to the upcoming release of our software. This PR is validated against NX 10. |
1951163 |
Siemens PLM believes that the Problem with a flange in NX Sheet Metal will be resolved by code changes made to the upcoming release of our software. The Problem with flange in NX Sheet Metal looks to be fixed in NX 10. If there is any such Flange in failed state, then perform Feature Playback to fix it. |
1951330 |
Siemens PLM believes that the problem you reported where the Journal Indicator for 'Preferences -> Teamcenter Integration' was missing will be resolved by code changes made to the upcoming release of our software NX 10. |
1951356 |
Siemens PLM believes that the problem you reported where Safety factor colour is incorrect in Stress wizard will be resolved by code changes made to the release of our product NX 10. The problem where Safety factor colour is incorrect in Stress wizard has been investigated and the following has been found. I could not replicate this problem, even using the exact same steps the user outlined. |
1951388 |
Siemens PLM believes that the problem you reported where Component in an array has the wrong attributes, will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 10. |
1951493 |
Siemens PLM believes that the problem you reported where view dependent edits vanish when "Hidden Line" option is set to Invisible will be resolved by code changes made to the release of our product NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them. |
1951575 |
Siemens PLM believes that the problem you reported where the Status Area does not accurately reflect the count of selected objects after selecting or de-selecting certain objects, such as the top assembly or expressions, in a navigator will be resolved by code changes made to the upcoming release of our software NX 10. |
1951941 |
The problem where feature update fails in NX 8.5 has been investigated and the following has been found. The root cause of the problem is the Stationary reference input, Datum plane, to the Draft(184) is missing. Most likely it would have been deleted. Despite this deletion the feature works fine until NX 8 but not from NX 8.5 onwards in which there had been major enhancements in Draft feature. Therefore any pre NX.85 draft, whose stationary plane has been deleted, will fail update from NX 8.5 onwards. Cases like these are very rare if not zero as in this case. In NX 10, we provided a fix to prevent this problem. So from NX 10 onwards these type of features , in which their Stationary plane is deleted, will also update without any problem. For technical reasons this fix can't be made available in NX 8.5 and NX 9. Coming to the solution for NX 8.5, we have a simple work around for this PR. As the datum plane input for Draft(184) has been deleted, creating in NX 6 a similar Datum plane as the one used in Draft(184) and using it as input for Draft(184) in the place of existing one would solve the problem. I have repaired the part in NX 6 using the method described above and the part passes playback cleanly. This part will be send by another Email to you ( per Siemens SECUFEX) (IR1951941_4222-027-21330-C_Draft-184_RepairedInNX605.7z) |
1951982 |
Siemens PLM believes that the problem you reported where trim and Extend fails in NX 8.5.2.3 in NX 6.0.2.8 it works will be resolved by code changes made to the upcoming release of our software NX 10. The PR has been fixed in NX 10. However, the user will have to recreate Trim and Extend(8) to see the fix. Since this fix cannot be backported to NX 8.5.3.2, there is a workaround suggested. The problem is that instead of extending 14 edges of the OffsetSurface(7), 12 edges are extended. The other 2 edges are extended by the same parameters as another feature. So the work around is to 1. make Trim And Extend(8) current feature, 2. EWR Trim And Extend(8), de-select the front bottom two edges. 3. Insert Trim and Extend and select the de-selected edges with the same input parameters. 4. Update to End. |
1952112 |
Siemens PLM believes that the problem you reported where retrieving radio box control items with UF_STYLER_SUBITEM_VALUES causes crash will be resolved by code changes made to the upcoming release of our software NX 10. |
1952186 |
Siemens PLM believes that the problem you reported where Flat pattern failed if solid cut under 90 degrees will be resolved by code changes made to the upcoming release of our software NX 10. |
1952263 |
The problem where "Incorrect dimple with circular or elliptical Curve" is fixed in release NX 10. To get the fix, user need to re-create Dimple feature in NX 10 or future release. |
1952331 |
The problem of the guide curve changing on edit does not happen in NX 10. with the new Weld Point Wizard. The used created is on the screen after create and is reused on edit. |
1952362 |
The problem where the Check-Mate Help needed additional information about the Part Save option on the Author Tests dialog box (Create/Edit Profile tab). In order for a profile to be run when a part is saved, three environment variables must be set. This problem is fixed in release NX 10. |
1952681 |
Siemens PLM believes that the problem you reported where Trim and Extend(8) fails in NX 8.5.2.3 MP1 will be resolved by code changes made to the upcoming release of our software NX 10. The PR has been fixed in NX 10. However, the user will have to recreate Trim and Extend(8) to see the fix. Since this fix cannot be back ported to NX 8.5.3, there is a workaround suggested. The problem is that instead of extending 14 edges of the Offset Surface(7), 12 edges are extended. The other 2 edges are extended by the same parameters as another feature. So the work around is to: 1. Make Trim And Extend(8) current feature, 2. Edit with Rollback Trim And Extend(8), de-select the front bottom two edges. 3. Insert Trim and Extend and select the de-selected edges with the same input parameters. 4. Update to End. Reworked parts can be made available when requested. |
1952907 |
Siemens PLM believes that the problem you reported with internal error in formboard part dependent to overstock will be resolved by code changes made to the upcoming release of our software NX 10. |
1952973 |
The problem where in some cases, references by annotations to PDM-based attributes have gone away has been fixed in release NX 10. The fix is also backported to previous releases. Loading the part in question, running the part cleanup (no selections needed) and saving the part should fix the references. Newest information of development: The fix will be added to NX 8.5.3 MP2 and customer agreed with that. This Maintenance Pack is planned to be ready for customer download on 14-Mar-2014. |
1953119 |
Siemens PLM believes that the problem you reported where the VRML Export fails when part names contain dots will be resolved by code changes made to the upcoming release of our software. The problem with file names being created incorrectly when the original name contains a dot has been addressed in NX 10. |
1953173 |
Siemens PLM believes that the problem you reported where "4222-249-08520_Draft(84) fails in NX 8.5.2.3 MP1" will be resolved by code changes made to the upcoming release of our software NX 9.0. This is the second time this CRR is sent. This PR 1953173 has been linked to 1953176, as it has a similar cause. But PR1953173 forms a special case of PR1953176 in that the stationary reference is perpendicular to the draw direction in PR1953173. Because of this special condition the PR is found to be fixed in NX 9 and hence we marked it as FN in NX 9 earlier. A remark from development: The reason for the failure i.e. deleting the stationary plane after draft is made and we don't recommend that as it is not a good practice to delete the plane after its use is over. =============================================================================== The root cause of the problem is that the Stationary reference input, Datum plane, to the Draft(84) is missing. Most likely it would have been deleted and I believe that NX has no role in this deletion. Despite this deletion the feature works fine until NX 8 but not from NX 8.5 onwards in which there had been major enhancements in Draft feature. Therefore any preNX 8.5 draft, whose stationary plane has been deleted, will fail update from NX 8.5 onwards. Cases like these are very rare if not zero as in this case. Anyway this problem has been rectified in NX 9 and the part passes playback successfully in NX 9. Coming to the solution for NX 8.5, we have a simple work around for this PR. As the datum plane input for Draft(84) has been deleted, creating in NX 6 a similar Datum plane/ Point (in this case as the Plane is perpendicular to Draw direction) as the one used for Draft(84) and using it as input for Draft(84) in the place of existing one would solve the problem. Open the Part in NX 6 --> Edit With Rollback Draft(84) --> De-select the 'Stationary Plane' Input --> Click on the Point Constructor --> You see that the X, Y, Z coordinates of the point constructor are filled with values X = -107.00347638373 Y = -112.758254700623 Z = 181.777563696959 --> Press OK and OK again --> The part has been repaired. I have repaired the part in NX6 using the method described above and the part passes playback cleanly. The fixed part will be available on request, 4222-249-08520_Draft(84)_repairedNX6_UM.prt. =============================================================================== |
1953176 |
Siemens PLM believes that the problem you reported where "Mpire bracket 2_Draft(184) fails in NX 8.5.2.3 MP1 on Playback" will be resolved by code changes made to the upcoming release of our software NX 10. Additional information: ------------------------ The root cause of the problem is the Stationary reference input, Datum plane, to the Draft(184) is missing. Most likely it would have been deleted. From NX 10 onwards these type of features, in which their Stationary plane is deleted, will also update without any problem. For technical reasons this fix can't be made available in NX 8.5 and NX 9. The repaired part (NX 6) will be send to customer. |
1953473 |
The problem where the clone failed with error: Teamcenter Error: 9069 and ERROR: (920007)is fixed in release NX 10. |
1953550 |
Siemens PLM believes that the problem you reported where Cannot create Parallel Dimension. If the view style is exact (pre NX 8.5) will be resolved by code changes made to the upcoming release of our software NX 10. |
1953606 |
Siemens PLM believes that the problem you reported monolithic JT files will be resolved by code changes made to the upcoming release of our software. The problem where monolithic jt files are imported as legacy NX Facets rather than JT Facets is fixed in NX 10. |
1953730 |
Siemens PLM believes that the problem you reported where NX does not recognize arrow heads and do no fill them out will be resolved by code changes made to the upcoming release of our software. The problem where NX does not recognize arrow heads and do not fill them out is fixed in release NX 10. |
1953796 |
Siemens PLM believes that the problem you reported where there is an error - An Operation was attempted on an invalid or unsuitable OM object will be resolved by code changes made to the upcoming release of our software NX 10. |
1953844 |
Siemens PLM believes that the problem you reported that Font Family fonts are not fully supported is missing in the documentation will be resolved by code changes made to the release of our product. The problem where it is not documented that NX does not support Arial Narrow fonts is fixed in NX 10. The Drafting Help already includes the following statement: "Although the FreeType Font library supports non scaleable and other font types, only salable TrueType, OpenType, and PostScript fonts are supported." The following sentences was added to this statement: "For example, the Arial narrow font style is not supported." |
1953922 |
Siemens PLM believes that the problem you reported with a BOM List Problem with Electrical routing formboard will be resolved by code changes made to the upcoming release of our software NX 10. |
1953954 |
Siemens PLM believes that the problem you reported where UFUi.SelectWithClassDialog throws Invocation Exception in Remote mode will be resolved by code changes made to the upcoming release of our software NX 10. The documentation will be extended to state "Callbacks in remoting mode are not supported in .Net". |
1953970 |
Siemens PLM believes that the problem you reported where you were unable to add the Clear Rotation Reference command to the view shortcut menu will be resolved by code changes made to the upcoming release of our software V10. |
1954017 |
Siemens PLM believes that the problem that you reported where the action of exporting a subset of an fea model to abaqus can take an unreasonable length of time and which may also result in erroneous entries in the abaqus input deck will be resolved by code changes made to the upcoming release of our software NX 10. |
1954040 |
Siemens PLM believes that the problem you reported where the Weld Fillet would not rebuild and results in retained feature will be resolved by code changes made to the upcoming release of our software NX 10. |
1954398 |
Siemens PLM believes that the problem you reported where (PS v27.0) Difference of behaviour between Face Blend and Edge Blend will be resolved by code changes made to the upcoming release of our software NX 10. |
1954423 |
Siemens PLM believes that the problem you reported where "Couldn't refile non-master - Unable to process entry" will be resolved by code changes made to the upcoming release of our software NX 10. |
1954545 |
Siemens PLM believes that the problem you reported where LENGTH_ADDITION and LENGTH_COEFFIECIENT are not applicable in Routing Mech will be resolved by code changes made to the release of our product NX version 10. The information has now been moved to the appropriate section of the help documentation. |
1954593 |
PS27.0.50::Bodydraft doesn't work for Revolve Angle from 180 to 360. |
1954699 |
Siemens PLM believes that the problem you reported where a wrong reversed Section Surface is created that does not match the preview will be resolved by code changes made to the upcoming release of our software NX 10. |
1954712 |
Siemens PLM believes that the problem you reported where Different result at Angular Dimension (synch Mod) between NX 7.5 and NX 8 /8.5 will be resolved by code changes made to the upcoming release of our software NX 10. |
1954880 |
Siemens PLM believes that the problem you reported where "Move object > Distance Between Points --> message: no motion has been specified" will be resolved by changes in the Documentation, made to the upcoming release of our software NX 10.. The Modeling Help for the Move Object, Distance Between Points option, has been rewritten to the following: Distance between Points - A linear distance derived from an origin point and a reference measurement point. When you specify the origin and measurement points and the vector, the current distance between the points appears in the Distance box. You can then specify a new value in the Distance box to move the object along the vector to a new relative location. |
1954900 |
Siemens PLM believes that the problem you reported where Opening SolidWorks assembly returns The PLM XML document failed to load will be resolved by code changes made to the upcoming release of our software NX 10. |
1955329 |
Siemens PLM believes that the problem you reported where mqc_check3DModel does not check for sheet bodies in the part will be resolved by code changes made to the upcoming release of our software NX 10. |
1955489 |
Siemens PLM believes that the problem you reported where Stock is not displayed for terminal port wires and cable not cut back as per NX7.5 will be resolved by code changes made to the upcoming release of our software NX 10. |
1955550 |
Siemens PLM believes that the problem you reported where you can't edit the sketch 1 in attached file due to the big size, will be resolved by code changes made to the upcoming release of our software NX 10. The problem where the system stack is filled up during update due to a very large amount of objects being managed has been fixed in release NX 10. |
1955572 |
Siemens PLM believes that the problem you reported where PDF export asks if you wish to replace existing file twice will be resolved by code changes made to the upcoming release of our software NX 10. |
1955851 |
The problem where Edit Fillet un-parametrizes a linked composite curve is fixed in NX 10. |
1955893 |
Siemens PLM believes that the problem you reported where the drop type "After" is never passed to onDropCallback() will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10. |
1956032 |
Siemens PLM believes that the problem you reported where Updating parent view hides Detail View Label if Delay View Update is turned off will be resolved by code changes made to the upcoming release of our software. This is fixed in NX 9.0.3 and NX 10. |
1956033 |
Siemens PLM believes that the problem you reported where text justification/alignment in Weld Symbols cannot be edited will be resolved by code changes made to the upcoming release of our software NX 10. |
1956238 |
Siemens PLM believes that the problem you reported where a KF class ug_motion_result failure causes not recoverable ADAMS motion error will be resolved by code changes made to the upcoming release of our software NX 10. |
1956438 |
Siemens PLM believes that the problem you reported where "Not possible to create pattern of a Trim-Feature" will be resolved by code changes made to the upcoming release of our software NX 10. |
1956444 |
Siemens PLM believes that the problem you reported where the Open C API function UF_OBJ_set_color() throws an Internal Error when called from a registered UF_open_part_reason callback will be resolved by code changes made to the upcoming release of our software NX 10. An error message will now be displayed stating that a work part must be present. |
1956543 |
Siemens PLM believes that the problem you reported where "The number of sheets changes automatically when you use the Orient View Tool" will be resolved by code changes made to the upcoming release of our software NX 10. |
1956599 |
Siemens PLM believes that the problem you reported where 2D local remesh create degenerated CQUAD4 elements will be resolved by code changes made to the upcoming release of our software NX 10. |
1956713 |
Siemens PLM believes that the problem you reported where loading parts causes Incorrect object for this operation exception to be raised is due to corrupt parts. NX code has been made tolerant of these kind of corruptions will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10. |
1956733 |
Siemens PLM believes that the problem you reported where the documentation about Mitered Bend type corner gives wrong impression will be resolved by changes made to the documentation in the upcoming release of our software NX 10. |
1957252 |
Siemens PLM believes that the problem you reported where DOC: FBM Information is not guilty in NX 8.5 (was in NX6) will be resolved by code changes made to the upcoming release of our software NX 10. |
1957288 |
Siemens PLM believes that the problem you reported where Define Custom Symbol dialog does not work when a LOV is attached to object_name will be resolved by code changes made to the upcoming release of our software NX 10. |
1957362 |
Siemens PLM believes that the problem you reported where Change of DB_PART_NO / item_id requires restart of NX, will be resolved by code changes made to the upcoming release of our software NX V10. |
1957848 |
Siemens PLM believes that the problem you reported where "Poor Performance in NX Advanced Simulation with Models that have Many Holes" will be resolved by code changes made to the release of our product NX 10. |
1957857 |
Siemens PLM believes that the problem you reported where "Poor Performance in NX Advanced Simulation with Models that have Many Holes" will be resolved by code changes made to the release of our product NX version 10. |
1957976 |
Siemens PLM believes that the problem you reported where Material Library Manager - displayed columns revert back to default settings when you leave the menu will be resolved by code changes made to the release of our software NX 10. |
1957998 |
Siemens PLM believes that the problem you reported where rbe3 'glue non-coincident' mesh mating conditions which were previously moved to one mesh collector are re-assigned to unique mesh collectors when an 'update finite element model' action is performed will be resolved by code changes made to the upcoming release of our software NX 10. |
1958047 |
Siemens PLM believes that the problem you reported where the 'global contact parameters' functionality is missing from the 'case control' tab within a 'sol 105 - linear buckling' solution will be resolved by code changes made to the upcoming release of our software NX 10. |
1958135 |
Siemens PLM believes that the problem you reported where Transform Path results in error - A tag was passed belonging to an object that could not be found, will be resolved by code changes made to the upcoming release of our software NX 10. |
1958362 |
Siemens PLM believes that the problem you reported parts for wrong Attribute Notes value will be resolved by code changes made to the upcoming release of our software. The problem where in some cases, references by annotations to PDM-based attributes have gone awry has been fixed in release NX 0. The fix is also back-ported to previous releases. Loading the part in question, running the part fixup (no selections needed) and saving the part should fix the references. |
1958378 |
Siemens PLM believes that the problem you reported where Thread representation in assemblies will be resolved by code changes made to the release of our product NX version 10. The problem where Symbolic Thread Curve from components not getting clipped is fixed in NX 10 IP 20. Symbolic Thread from the component will be clipped only if the body referenced by this thread is selected for clipping. To know body referenced by symbolic thread corresponding component needs to be fully loaded. So note that component corresponding to symbolic thread needs to be fully loaded to see threads clipped. |
1958492 |
Siemens PLM believes that the problem you reported where stock is not displayed correctly after applying Miter Corner will be resolved by code changes made to the upcoming release of our software NX 10. |
1958529 |
Siemens PLM believes that the problem you reported where Moldwizard cannot change parameters of moldbase components in next session will be resolved by code changes made to the upcoming release of our software NX 10. The fix is also submitted to NX 9.0.2 MP1. |
1958694 |
Siemens PLM believes that the problem you reported a case where it isn't possible to Delete a Spline in Sketch will be resolved by code changes made to the upcoming release of our software. The problem where user is unable to delete spline in sketch is fixed in release NX 10. |
1958753 |
Siemens PLM believes that the problem you reported where nx crash when open component fully on a assemble will be resolved by code changes made to the upcoming release of our software. The problem where in some cases, references by annotations to PDM-based attributes have gone away has been fixed in release NX 10. The fix is also back-ported to previous releases. Loading the part in question, running the part fixup (no selections needed) and saving the part should fix the references. |
1958817 |
Siemens PLM believes that the problem you reported where an imported drawing template does not display the drawing border, will be resolved by code changes made to the upcoming release of our software NX 10. |
1958868 |
Siemens PLM believes that the problem you reported where Toolpath generate returns in an O/S Error and Customer cannot save the Part (2GB range) will be resolved by code changes made to the release of our product NX 10. |
1958930 |
Siemens PLM believes that the problem you reported where the UI preferences dialog is showing complete journal support but the journaling is not capturing the windows style changes will be resolved by code changes made to the upcoming release of our software NX 10. |
1959247 |
Siemens PLM believes that the problem you reported where the simple measure dialog is not correct will be resolved by code changes made to the upcoming release of our software NX 10. |
1959388 |
Siemens PLM believes that the problem you reported where Reference Set defined in PTB file no longer used during place part will be resolved by code changes made to the upcoming release of our software NX 10. |
1959399 |
Siemens PLM believes that the problem you reported where Floe_Best-Replace Face 121.prt fails in NX 8.5.2 MP2 playback will be resolved by code changes made to the upcoming release of our software NX 10. |
1959460 |
Siemens PLM believes that the problem you reported where stress, strain and creep strain results data (for CPLSTS8 elements) output from a SOL 601 analysis cannot be post-processed by NX will be resolved by code changes made to the upcoming release of our software NX 10. |
1959509 |
Siemens PLM believes that the problem that you reported where an error of the form: 'physical property plsolid1 has no assigned material' is issued at export when more than one mesh with a 'mathp - simple' material definition reference the same physical property, will be resolved by code changes made to the upcoming release of our software NX 10. |
1959558 |
Siemens PLM believes that the problem you reported where rebend failed if SM part is huge will be resolved by code changes made to the upcoming release of our software NX 10. |
1959835 |
Siemens PLM believes that the problem you reported where importing a new 'condition sequence' (.bdd file) where one of the previously defined parameters is missing from the .bdd file causes the subsequent analysis to fail (note that the parameter is still present within nx but has no value), will be resolved by code changes made to the release of our product NX 10. |
1959880 |
Siemens PLM believes that the problem you reported where associative translated weld points do not update the local CSYS after a change will be resolved by code changes made to the upcoming release of our software NX 10.Prior releases had no associativity by design. NX 10.0 will be ready for customer download from 23-Dec-2014. |
1960018 |
Siemens PLM believes that the problem you reported where the NXOpen method NXObject.DeleteUserAttribute() doesn't delete attribute array member without an existing attribute template will be resolved by code changes made to the upcoming release of our software NX 10. |
1960045 |
Siemens PLM believes that the problem you reported where the documentation for NXObject::DeleteUserAttribute is unclear will be resolved by code changes made to the upcoming release of our software NX 10. |
1960345 |
Siemens PLM believes that the problem you reported where the displayed color of a facet body is different to the info object color will be resolved by code changes made to the upcoming release of our software NX 10. The problem where The displayed color of a facet body is different to the info object color is due the fact that provided jt is a monolithic jt file and is fixed in NX 10 IP3 NX 10 has enhancements that imports such jt files as LW bodies instead of NX Facet bodies. Jt facets provide sectioning with much richer information. |
1960373 |
Siemens PLM believes that the problem you reported where Unable to import assemblies using clone-based TC import will be resolved by code changes made to the upcoming release of our software NX 10.This version will be ready for customer download from 23-Dec-2014. |
1960579 |
Siemens PLM believes that the problem you reported where Error : No gravity in model will be resolved by code changes made to the upcoming release of our software NX 10. |
1960711 |
Siemens PLM believes that the problem you reported where "Stacked attributes values don't update" will be resolved by code changes made to the upcoming release of our software NX 10. |
1961305 |
Siemens PLM believes that the routing problem you reported where "Work part has not been converted" will be resolved by code changes made to the upcoming release of our software NX 10. |
1961375 |
Siemens PLM believes that the problem you reported where routing curve points show invalid constraints using on curve snap will be resolved by code changes made to the upcoming release of our software NX 10. |
1961386 |
Siemens PLM believes that the problem you reported where the user is unable to save part when part name violates naming rule will be resolved by code changes made to the upcoming release of our software NX 10. |
1961537 |
Siemens PLM believes that the problem you reported where BaseData Loadings defined by absolute values are modified will be resolved by code changes made to the upcoming release of our software NX 8.5.2MP1, NX and in NX 10. |
1961652 |
Siemens PLM believes that the problem you reported where intersection tool gives alert when one body is inside the other will be resolved by code changes made to the upcoming release of our software NX 10. |
1961948 |
Siemens PLM believes that the problem you reported where "Feature to be reordered is being referenced" and "parts with features applied to stock features" will be resolved by code changes made to the upcoming release of our software NX 10, NX 9.0.1 and MPs to NX 8.5.3 and NX 8.5.2. |
1961972 |
Siemens PLM believes that the problem you reported where UF_MODL_ask_bounding_box_aligned loop fails with "Tag limit would be exceeded" will be resolved by code changes made to the upcoming release of our software NX 10.5 |
1962104 |
Siemens PLM believes that the problem you reported where "some 1D element results are not color contoured" will be resolved by code changes made to the upcoming release of our software NX 10. |
1962349 |
Siemens PLM believes that the problem you reported where an Assembly cannot be loaded in NX 8.5.3 anymore will be resolved by code changes made to the upcoming release of our software. The problem opening parts with features applied to stock features has been fixed in NX 10, NX 9.0.1 and MPs to NX 8.5.3 and NX 8.5.2. |
1962404 |
Siemens PLM believes that the problem you reported where Inserting surface finish symbol takes a very long time when parts list is placed will be resolved by code changes made to the upcoming release of our software NX 10. |
1962547 |
Siemens PLM believes that the problem you reported where the Open C API UF_TEXT_load_translation_file() fails with error code 1 subsequently will be resolved by code changes made to the upcoming release of our software NX 10. It will now return an error UF_err_already_loaded. |
1962630 |
Siemens PLM believes that the problem you reported where "objects are missing in vrml file" will be resolved by code changes made to the upcoming release of our software NX 10. The fix will also be submitted to NX 9.0.1. |
1962638 |
Siemens PLM believes that the problem you reported where there was an error in Expression Name during Creation of a symbolic thread with manual input will be resolved by code changes made to the upcoming release of our software NX 10. |
1962746 |
Siemens PLM believes that the problem you reported where New Pattern Feature: Can't pattern a TrimBody Feature will be resolved by code changes made to the upcoming release of our software NX 10. |
1962824 |
Siemens PLM believes that the problem you reported where the help for the Standard Part Management dialog box didn't show up in the help collection will be resolved by code changes made to the upcoming release of our software NX 10. |
1962826 |
Siemens PLM believes that the problem you reported where Poor documentation of Material Mapping will be resolved by changes made to the documentation of our product NX version 10. |
1962832 |
Siemens PLM believes that the problem you reported where JT without BREP and MONOLITHIC doesn't create measurable bodies will be resolved by code changes made to the upcoming release of our software. The problem where importing monolithic jt without brep creates NX facets instead of Jt Facets is fixed in NX 10. |
1962893 |
The request for additional information in the Assemblies Help about the Component Properties options in the Replace Component dialog box is fixed in release NX 10. This version is planned to be ready for customer download from 23-Dec-2014. |
1962942 |
The problem where the Assemblies Help needed additional information about how component name changes via the name options in the Component Properties dialog box are considered overrides, which are therefore applied to replacement components as well, is fixed in NX 10. |
1962947 |
The problem where the Assemblies Help needed additional information about how component name changes via the name options in the Component Properties dialog box are considered overrides, which are therefore applied to replacement components as well, is fixed in NX 10. |
1963051 |
Siemens PLM believes that the problem you reported where in a part specific situation incorrect offset midsurface is generated will be resolved by code changes made to the release of our product NX 10. |
1963148 |
Siemens PLM believes that the problem you reported where Tube function output "Single Segment" creates incorrect tangential point will be resolved by code changes made to the upcoming release of our software NX 10. The Tube feature has been enhanced to produce better output for tangent curves for "single segment" output option. The swept surface of the Tube will terminate at the end of each discrete curve in the tangent-continuous path. Tube features created in NX 10 and later will have the new behavior; NX 9 and older features will continue to maintain their output geometry. |
1963172 |
Siemens PLM believes that the problem you reported where "The Model Setup Check warning regarding an LBC being applied to unmeshed or partially meshed geometry is not properly issued for NASTRAN SOL 106 solutions" will be resolved by code changes made to the upcoming release of our software NX 10. |
1963360 |
Siemens PLM believes that the problem you reported where Qualify Part, Port Characteristics problem with the "Reference" Option was validated against NX 10.0 and it was found to be resolved. |
1963372 |
Siemens PLM believes that the problem you reported where simulation results could not be queried due to an internal error will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10. |
1963897 |
Siemens PLM believes that the problem you reported where "streamlines are not correctly displayed in a specific model" will be resolved by code changes made to the upcoming release of our software NX 10. |
1963969 |
Siemens PLM believes that the problem you reported where in NX9 - BC Plot Contours - Zero value - Alert - "There are no values to Display" will be resolved by code changes made to the upcoming release of our software NX 10. |
1964037 |
Siemens PLM believes that the problem you reported where Special German Character like "ä" does not work for customized CAM-Template will be resolved by code changes made to the release of our product NX 10. |
1964187 |
Siemens PLM believes that the problem you reported where "Hole Positioning dimensions displayed on wrong location" will be resolved by code changes made to the upcoming release of our software NX 10. |
1964410 |
Siemens PLM believes that the problem you reported where CA_Quantity A/R if you create Component array with db_unit attribute will be resolved by code changes made to the upcoming release of our software NX 10. |
1964487 |
Siemens PLM believes that the problem you reported where Feature Playback error in NX 9 will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014. |
1964499 |
Siemens PLM believes that the problem you reported about Feature Playback error in NX9 will be resolved by code changes made to the upcoming release of our software NX 10. |
1964850 |
Siemens PLM believes that the problem you reported where Groove_OD ignores stop position point while profiling will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10. |
1964971 |
Siemens PLM believes that the problem you reported where UF_EVALSF_evaluate() returns incorrect points with X-form B-surface will be resolved by code changes made to the upcoming release of our software NX 10. |
1965071 |
Siemens PLM believes that the problem you reported where adding the Electrical "Routing_BOM_metric" table raised: "An operation was attempted on an invalid or unsuitable OM object", will be resolved by code changes made to the release of our product NX 10. |
1965219 |
Siemens PLM believes that the problem you reported where "Assembly part fails to load in NX 8.5.3.3" will be resolved by code changes made to the upcoming release of our software NX 10. |
1965234 |
Siemens PLM believes that the problem you reported with a problem of dxfdwg.exe will be resolved by code changes made to the upcoming release of our software. The problem where translator fails during export to dxf is resolved. The fix is available in NX 10. |
1965281 |
Siemens PLM believes that the problem you reported where when using the 'copy & paste' function on the laminates 'layup modeler' form to create new plies, the numbering of the plies is reversed so that they are no longer sequential when the 'paste repetition' option is set to '2' or greater, will be resolved by code changes made to the upcoming release of our software NX 10. |
1965317 |
Siemens PLM believes that the problem you reported where Maximum Velocity and Maximum Degrees per Minute were not documented in the Edit Axis dialog box will be resolved by code changes made to the upcoming release of our software NX 10. |
1965326 |
Siemens PLM believes that the problem you reported where View Break update failed - dimensions are invisible will be resolved by code changes made to the upcoming release of our software NX 10. |
1965349 |
Siemens PLM believes that the problem you reported where Weld Point:It is not possible to change Guide curve parameter using multiple Ref will be resolved by code changes made to the upcoming release of our software. The problem of being able to change parameters of guide curves for multiple overlap sheets is fixed in the NX 10 Weld Point Wizard. |
1965477 |
Siemens PLM believes that the problem you reported where "Incorrect Annotation Sketch Display for Variational Sweep " will be resolved by code changes made to the upcoming release of our software NX 10. |
1965769 |
Siemens PLM believes that the problem you reported regarding Checker issues with Check Single Part Attribute / Check Multiple Part Attributes will be resolved by code changes made to the upcoming release of our software NX 10. The "issue1" in this PR is fixed in NX 10. The checker document in mqc_check_single_part_attr.dfa now indicates that the format of mapping rule MATCH_ONE_IN_SET should be a string of attribute values, separated by semicolons, for example, "MLDES; MLASM; LYTFMT". Regarding to "issue2", the user should customize the "attr_titles_MatchMethod_MatchParam_init" attribute instead of "attr_titles_MatchMethod_MatchParam" attribute in a customized "Check Multiple Part Attributes" checker dfa file. The list type parameter adds a list window dialog item in the customization dialog, which does not allow any text input. The user can only select the listed items which are pre-specified by the "attr_titles_MatchMethod_MatchParam_init" attribute. The user can follow the steps described in the checker document to customize the checker template. |
1965794 |
Siemens PLM believes that the problem you reported where Change of DB_PART_NO / item_id required restart of NX will be resolved by code changes made to the upcoming release of our software NX 10. |
1965892 |
Siemens PLM believes that the problem you reported where DB_Part_Name and DB_Part_Desc cannot be edited from the part family table will be resolved by code changes made to the upcoming release of our software NX 10. |
1965920 |
Siemens PLM believes that the problem you reported where UGTO2D.exe '-r' option needed adding to help documentation will be resolved by code changes made to the upcoming release of our software NX 10. |
1966072 |
Siemens PLM believes that the problem you reported where there is an incorrect reference to Assembly Navigator Toolbar in NX documentation will be resolved by code changes made to the upcoming release of our software NX 10.0 |
1966387 |
Siemens PLM believes that the problem you reported where 3D-Mesh creation changes 2D reference-mesh will be resolved by code changes made to the upcoming release of our software NX 10. |
1966573 |
The problem where the existing information regarding the Import and Export Expressions was not correct is fixed in NX 10.0 Help documentation. Added the information that the Import and Export Expressions command works for the user-defined expressions. |
1966774 |
Siemens PLM believes that the problem you reported where External NC-code file simulation with default MCP causes exception (VNCK) will be resolved by code changes made to the upcoming release of our software NX 9.0.2 ; NX 10 |
1967088 |
Siemens PLM believes that the problem you reported where Invalid values found in stress-strain data table for material "Test material" will be resolved by code changes made to the upcoming release of our software NX 10. |
1967100 |
Siemens PLM believes that the problem you reported where Measure Projected distance displays different results in information window will be resolved by code changes made to the upcoming release of our software NX 10. |
1967173 |
Siemens PLM believes that the problem you reported with the empty CollisionPairBuilderList from new CollisionConfigurationBuilder will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10. |
1967249 |
Siemens PLM believes that the problem you reported where about "Problem with FEM's groups and SIM's groups in postprocessing" will be resolved by code changes made to the upcoming release of our software NX 10. |
1967288 |
Siemens PLM believes that the problem you reported "Mechanical Load summary returns null values for Pressure LOAD (components option)" will be resolved by code changes made to the upcoming release of our software NX 10. |
1967415 |
Siemens PLM believes that the problem you reported where "Internal Error Memory access violation appears" will be resolved by code changes made to the release of our product NX 10. |
1967465 |
Siemens PLM believes that the problem you reported where wrong Hinge direction on creation Section view with moving sections arrows will be resolved by code changes made to the upcoming release of our Software NX 10. |
1967665 |
Siemens PLM believes that the problem you reported where "too big difference of weight when mirror body" has been fixed in Parasolid. It will be resolved by code changes made to the upcoming release of our software NX 10. |
1967669 |
Siemens PLM believes that the problem you reported where adding a detail view leads to an error during update will be resolved by code changes made to the upcoming release of our software NX 10. |
1967747 |
Siemens PLM believes that the problem you reported where Bead over bend produces not tangent faces will be resolved by code changes made to the upcoming release of our software NX 10. |
1967813 |
Siemens PLM believes that the problem you reported where "save All from the sim file does not save the fem file but only the sim file" will be resolved by code changes made to the upcoming release of our software NX 10. |
1967838 |
Siemens PLM believes that the problem you reported where: You Can't select positioning dimensions without clicking icon twice will be resolved by code changes made to the release of our software NX 10. |
1967870 |
Siemens PLM believes that the problem you reported where the NXOpen property 'AttributePropertiesBaseBuilder.ObjectPicker' should be marked as deprecated will be resolved by code changes made to the upcoming release of our software NX 10. We deprecated the 'NXOpen.AttributePropertiesBaseBuilder.ObjectPicker' method as this can only set attributes on certain type of objects whereas the new method added doesn't have such limitation. User can use NXObject.GetUserAttributeSourceObjects to get the source objects. |
1967944 |
Siemens PLM believes that the problem you reported where an embedded custom symbol with multiple text attributes is not displayed correctly, will be resolved by code changes made to the upcoming release of our software NX 10. |
1967966 |
Siemens PLM believes that the problem you reported where Define Deformable Part menu missing after switching to Routing application will be resolved by code changes made to the upcoming release of our software NX 10. |
1968046 |
Siemens PLM believes that the problem you reported where Pattern of trim body feature is not possible will be resolved by code changes made to the upcoming release of our software NX 10. |
1968131 |
Siemens PLM believes that the problem you reported where NX routing does not read all values from bend radius tables will be resolved by code changes made to the release of our product NX version 10.0. |
1968301 |
Siemens PLM believes that the problem that you reported where the 'menu, insert, mesh, mesh control, biasing on edge' settings are not honoured when applied to a '2d (free) mesh' will be resolved by code changes made to the upcoming release of our software NX 10.Note that these same settings are honoured if applied to a '2d mapped mesh', which might provide a work-around in some scenarios. |
1968521 |
Siemens PLM believes that the problem you reported with a wrong measurement result between components will be resolved by code changes made to the upcoming release of our software. The problem with different values between the facet measurement and the solid geometry measurement has been addressed in NX 10. |
1968538 |
The problem where view dependent edits vanish when "Hidden Line" option is set to Invisible is fixed in NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them. A new procedure entitled "Display only view dependently edited hidden lines" is added to the Drafting Help that documents the process. |
1968917 |
The issue where the Model Setup Check erroneously issued a warning about mass elements and gravity/centrifugal loads has been resolved in NX 10. |
1968995 |
Siemens PLM believes that the problem you reported where Versioning Rules as described in NX help documentation do not work will be resolved by code changes made to the upcoming release of our software NX 10.The documentation has been corrected to show the correct versioning rules. |
1969088 |
Changing the reference set with the toolbar does not un-select component. |
1969191 |
Siemens PLM believes that the problem you reported where "Weld point: Hidden links cannot be deleted" will be resolved by code changes made to the upcoming release of our software NX 10. The problem of Hidden linked created by the Weld Point command has been resolved. In NX 10 the Weld Point command has been replaced by the Weld Point Wizard. Linked faces can now be found if they still exist after edit. |
1969484 |
Siemens PLM believes that the problem you reported where Information Object shows density 0.13mm in NX 8.5.3 and Thin in NX 8.5.2 will be resolved by code changes made to the release of our product NX version 10. This fix is backported in following MPs: NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP. |
1969640 |
Siemens PLM believes that the problem you reported where shaft tolerance values for the Fits and Limits are not updated will be resolved by code changes made to the upcoming release of our software NX 10. |
1969727 |
Siemens PLM believes that the problem you reported where UF_DRF_create_label causes an Internal Error will be resolved by code changes made to the upcoming release of our software. Given program creates label with UF_DRF_leader_attach_object leader attachment type and specifying NULL_TAG for leader terminator. If NULL_TAG is specified for assoc object then it means leader is created at screen position. For such case UF_DRF_leader_attach_screen type should be used as UF_DRF_leader_attach_type_t. Same thing needs to be modified in user program to fix this issue. Updated documentation of method UF_DRF_create_label to include above case. This will be fixed in NX 10. |
1969762 |
Siemens PLM believes that the problem you reported where MB3 on treelist item displays incorrect context menu will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014. |
1969936 |
Siemens PLM believes that the problem you reported where Help on context doesn't work if UGII_DISABLE_HELP_PAGE=0, will be resolved by code changes made to the upcoming release of our software NX 10. Actually the fix is to not support this env variable and always open help pages on external browser. |
1969982 |
The problem where Context Sensitive Help didn't work on the Pattern Component dialog box is fixed in release NX 10. |
1969994 |
Siemens PLM believes that the problem you reported where Thread lines wrong displayed in Revolved Section View will be resolved by code changes made to the release of our product NX 10. The problem where drafting thread curves are missing a transform and therefore incorrectly displayed in new exact, revolved section views is fixed in NX 10. |
1970126 |
Siemens PLM believes that the problem you reported where Formboard Drawing loses all Path Length Annotations after update will be resolved by code changes made to the upcoming release of our software NX 10. |
1970200 |
Siemens PLM believes that the problem you reported where an abaqus 'bolt pre-load constraint' boundary condition is incorrectly exported to the abaqus .inp file if it has been defined on more than one element will be resolved by code changes made to the upcoming release of our software NX 10. |
1970202 |
Siemens PLM believes that the problem you reported where Checkmate Bodies Consistency crash will be resolved by code changes made to the upcoming release of our software NX 10 and later. |
1970244 |
Siemens PLM believes that the problem you reported where 'the dimension text would flip for angular dimension in some cases', has been fixed in NX 10. This issue occurred when text was centered and auto placement was off will be resolved by code changes made to the upcoming release of our software NX 10. |
1970391 |
Siemens PLM believes that the problem you reported where there is an error- A dimension subscript for an array attribute was out of range or invalid will be resolved by code changes made to the upcoming release of our software NX 10. |
1970470 |
Siemens PLM believes that the problem you reported where the mechanical load summary of hydrostatic load doesn't agree with Nastran OLOAD will be resolved by code changes made to the release of our product. A fix for the unit conversion problem has been submitted to NX 10. |
1970780 |
Siemens PLM believes that the problem you reported where wrong Hinge direction on creation Section view with moving sections arrows will be resolved by code changes made to the upcoming release of our software NX 10. |
1971069 |
Siemens PLM believes that the problem you reported where Export to Geo file fails with invalid curve topology will be resolved by code changes made to the upcoming release of our software NX 10. |
1971127 |
Siemens PLM believes that the problem you reported where Unable to open part - A deleted or invalid class id was used will be resolved by code changes made to the upcoming release of our software NX 10.As requested, the given part has been fixed and provided to the customer as file "334_J1472_A_fixed.prt". Furthermore, a robustness fix will be put into NX 10 to allow the originally corrupt part to be open in NX 10 and future NX versions. |
1971148 |
Siemens PLM believes that the problem you reported where after Divide Face->Draft creates error when using 2 sets in different directions will be resolved by code changes made to the upcoming release of our software NX 10. |
1971198 |
Siemens PLM believes that the problem you reported where Non-associative mirror body is inconsistently associative for the threads will be resolved by code changes made to the upcoming release of our software NX 10. |
1971211 |
Siemens PLM believes that the problem you reported where a Datum CSYS cannot be selected in assembly level (E.g.: Move to Layer, Hide, ...) will be resolved by code changes made to the upcoming release of our software NX 10. |
1971401 |
Siemens PLM believes that the problem you reported where the problem with updating sketch in NX8.5 will be resolved by code changes made to the upcoming release of our software NX 10. The vertical dimension "p95=DFH_SPL*.1" in Sketch GUCGEC_001:Contour Screw has some of its data missing. If you delete and re-create this dimension, the part will get fixed. We have made code change to cope with this bad data in NX 10 (phase 12). The dimension will now get fixed when you open the part in NX 10. The WA for earlier releases is to re-create this dimension. |
1971441 |
Siemens PLM believes that the problem you reported where Error with special characters in file and folder of NX Open BlockStyler will be resolved by code changes made to the upcoming release of our software NX 10. |
1971589 |
Siemens PLM believes that the problem you reported where Scope of delayed update customer default gives different results in NX8 onwards is fixed in patches NX 8.5.3 MP4 and NX 9.0.1 MP2 along with NX 10. |
1971693 |
Siemens PLM believes that the problem you reported where Adding part to assembly, part disappears from preview window during constraining will be resolved by code changes made to the upcoming release of our software NX 10. |
1971837 |
Siemens PLM believes that the problem you reported where "ug_import from custom Item with mapped material attribute results in error" will be resolved by code changes made to the upcoming release of our software NX 10 |
1971845 |
Siemens PLM believes that the problem you reported where NX SheetMetal Bead Function not work clean will be resolved by code changes made to the upcoming release of our software NX 10. |
1971854 |
Siemens PLM believes that the problem you reported where the command 'File -> Plot -> Color and Width -> Custom Widths -> Define Widths -> Open WDF' and the OpenC method UF_PLOT_read_custom_widths_from_wdf() does not read back the value correctly for the twelfth width entry will be resolved by code changes made to the upcoming release of our software NX 10. |
1971981 |
Siemens PLM believes that the problem you reported where Stock is not displayed correctly after applying Miter Corner will be resolved by code changes made to the upcoming release of our software NX 10.Miter corner will generate correct result. |
1971985 |
Siemens PLM believes that the problem you reported with the Wrong Display of a section in the Profile and destruction of Path will be resolved by code changes made to the upcoming release of our software V10.0. |
1972046 |
Siemens PLM believes that the problem you reported where a Boolean fails will be resolved by code changes made to the upcoming release of our software NX 10. |
1972084 |
Siemens PLM believes that the problem you reported where mirror feature doesn't mirror all blend edges will be resolved by code changes made to the upcoming release of our software NX 10. |
1972402 |
Siemens PLM believes that the problem you reported where Formboard Orient Branch gives incorrect results will be resolved by code changes made to the upcoming release of our software NX 10. |
1972461 |
Siemens PLM believes that the problem you reported where Save Failed will be resolved by code changes made to the upcoming release of our software NX 10. |
1972491 |
Siemens PLM believes that the problem you reported where "NX9 CAE Post View and Excel spreadsheet generates an issue" will be resolved by code changes made to the release of our product NX 10. |
1972594 |
Siemens PLM believes that the problem you reported where performance problem if "Part Name Style Attribute" is changed to object_string will be resolved by code changes made to the release of our software NX 10 the fix may also be back ported to the desired MPs of previous NX version as needed. |
1972666 |
The problem where Sketch result wrong after mirroring the feature - NX 8.5.3 vs. NX 9.0.1 has been investigated and the following has been found. Stabilizing the two sketches in the part by adding an "Intermediate Datum CSYS" and "Project the Work Part Origin" has resolved the issue at hand! Please refer to the uploaded NX75_model_in_NX85_1-Fixed.prt as a workarond and the Reattach-Fix.avi the steps taken to apply the workarond! Download the file here: http://download.industrysoftware.automation.siemens.com/special.php/returned/cg -clean.92744-1.00uwm000_a_fixed_in_nx7554.prt.7z |
1972668 |
Siemens PLM believes that the problem you reported where additional documentation is needed for the "Structure Update on Save" preference will be resolved by code changes made to the upcoming release of our software NX 10. |
1972839 |
Siemens PLM believes that the problem you reported where the NXOpen method NXOpen::Die::DieCollection::CreateDrawBeadBuilder requires a 'ug_die_design' license will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3, NX 9.0.2, NX 10. |
1972973 |
Siemens PLM believes that the problem you reported where NX hangs and crashes with 3D annotations on tets elements will be resolved by code changes made to the upcoming release of our software NX 10. |
1973146 |
Siemens PLM believes that the problem you reported where the "Cannot split 2d shell element: attempt to write to freed object" message appear will be resolved by code changes made to the upcoming release of our software NX 10. |
1973160 |
Siemens PLM believes that the problem you reported where Opening drawing loads objects on demand from master model will be resolved by code changes made to the release of our product NX 10.The part will now open properly but the user will need to perform a part cleanup once the part is opened. |
1973190 |
The problem where text associated to an attribute in a Pattern is wrong when exported in DXF is fixed in release NX 10.0 for legacy text. The use of the component object name to resolve attributes is not robust since objects in NX do not have unique names. Customers should strongly consider the use of sheet templates. Sheet templates use a more robust technique to resolve master model attribute references instead of relying on object names which are not unique. |
1973229 |
Siemens PLM believes that the problem you reported where non-circular edges can be selected for radius/diameter measurement, will be resolved by code changes made to the upcoming release of our software NX 10. |
1973239 |
Siemens PLM believes that the problem you reported where applying a Pattern feature using Variational method moves faces will be resolved by code changes made to the upcoming release of our software NX 10. |
1973298 |
Siemens PLM believes that the problem you reported where NXOpen.Features.FeatureCollection.GetAssociatedFeaturesOfEdge causes an Internal Error on specific edges will be resolved by code changes made to the upcoming release of our software NX 10. |
1973304 |
Siemens PLM believes that the problem you reported where "Within Work Part Only" selection scope does not work when sketch is active will be resolved by code changes made to the upcoming release of our software NX 10. |
1973375 |
Siemens PLM believes that the problem you reported will be resolved by code changes made to the upcoming release of our software. The problem where expression get hidden is fixed in release NX 10. |
1973410 |
The problem you reported where One Step Formability does not work in NX Manager because of creating a new Item in background is necessary and there are no further Items in the current Naming Rule pattern available can not be fixed. The creation of the new Item in background is necessary and working as designed. The software was changed for NX 10 to give the user an error message in case that new FEM part cannot be created in background for mesh elements so that user may check whether he can really create any new part with his TC settings. |
1973428 |
Siemens PLM believes that the problem you reported where a "fem file creation using prt takes 6 hours when High resolution polygon bodies ON" will be resolved by code changes made to the upcoming release of our software NX 10. |
1973498 |
Siemens PLM believes that the problem you reported where modifying an Assembly Cut operation gives incorrect results (due to the reordering of assembly-level features), will be resolved by code changes made to the upcoming release of our software NX 10. |
1973566 |
Siemens PLM believes that the problem you reported where "incorrect percental physical viscous damping in NX response when using CBUSH elements" will be resolved by code changes made to the upcoming release of our software NX 10. Notes: - If the user creates a new FE model in NX 10, there will be no issue. The user interface will show correct units. - If the FE model was created with previous versions of NX, the value of Rotational Viscous Damping is kept (no conversion), but the correct units will be shown in the user interface. Therefore, the user must make sure that the value is correct and corresponds to the new units (the exported deck in NX 10 may show different values than the deck created in NX 9 or prior), especially in case of formulas and Field Tables. |
1973659 |
Siemens PLM believes that the problem you reported where "Arrow display with text results format not updating" will be resolved by code changes made to the upcoming release of our software NX 10. |
1973816 |
Siemens PLM believes that the problem you reported where Reference Set not switching back will be resolved by code changes made to the upcoming release of our software NX 9.0.3. |
1974020 |
Siemens PLM believes that the problem you reported where the Documentation of NXOpen.BlockStyler.SelectObject.AddFilter needs correction will be resolved by code changes made to the upcoming release of our software NX 10. |
1974026 |
The problem where unchanged assembly with part family members is marked modified when a new part is created in same session is fixed in release NX 10. |
1974203 |
Siemens PLM believes that the problem you reported where rectangle selecting components when doing Edit Explosion selects the entire assembly will be resolved by code changes made to the upcoming release of our software NX 10. |
1974223 |
Siemens PLM believes that the problem you reported with NX Sheet Metal Bead dialog legend will be resolved by code changes made to the upcoming release of our software NX 10. |
1974247 |
Siemens PLM believes that the problem you reported where "no Deviation Gauge between Facet Body and Faces/Sheet" will be resolved by code changes made to the upcoming release of our software NX 10. |
1974274 |
Siemens PLM believes that the problem you reported where the dispatcher go in "TERMINAL" with an empty NX dataset will be resolved by code changes made to the upcoming release of our software Teamcenter 11.1 |
1974281 |
Siemens PLM believes that the problem you reported where Bead dialog box topic had description for Punch Radius will be resolved by code changes made to the upcoming release of our software NX 10. |
1974290 |
Siemens PLM believes that the problem you reported where Error when using a formula to enter the mass of a 0D element will be resolved by code changes made to the upcoming release of our software NX 10. |
1974324 |
Siemens PLM believes that the problem you reported where a different read result from JT files without BRep will be resolved by code changes made to the upcoming release of our software. In NX 10 the demo_new.jt file will be loaded into NX and produces a Lightweight body as expected. This was a project enhancement done for NX 10. The problem is that the demo_new.jt file is a MONOLITHIC Jt file, and it contains a JtInstance node at level 5 between the VisMetaDataNode and the VisPartNode. In Demo.jt there is not a JtInstance node there. So if the producer of the Jt file could remove the extra JtInstance node, the Jt file will also work in NX 9. |
1974372 |
Siemens PLM believes that the problem you reported where Selection filter keeps resetting will be resolved by code changes made to the upcoming release of our software NX 10. |
1974566 |
Siemens PLM believes that the problem you reported where Direct Model (JT) Dataset not removed or updated for NX empty part will be resolved by code changes made to the upcoming release of our software NX 10. |
1974689 |
The original issue logged in this PR for the NASTRAN Exporter aborting when processing PLOAD4s has been resolved. Subsequent issues reported for missing beam section assignment and incorrect AFEM label resolution have also been resolved. All this was verified in NX 10. |
1974692 |
Siemens PLM believes that the problem you reported where the button "Define Deformable Part" menu button disappears after switching to routing will be resolved by code changes made to the upcoming release of our software NX 10. |
1974718 |
Siemens PLM believes that the problem you reported where Box All Selection for 3D element was not picking some internal elements/elemnode, will be resolved by code changes made to the upcoming release of our software NX 10. |
1974876 |
Siemens PLM believes that the problem you reported where "NX UI hangs and NX exporter generates a wrong NX Nastran deck file" will be resolved by code changes made to the release of our product NX 10. |
1974999 |
Siemens PLM believes that the problem you reported where "Show/Hide of JointMark-feature in feature groups" will be resolved by code changes made to the upcoming release of our software in NX 10.0 (in P10.0/phase 12). |
1975014 |
Siemens PLM believes that the problem you reported where "Drafting issue - View update loop caused by dependent section views containing" will be resolved by code changes made to the upcoming release of our software NX 10. |
1975068 |
Siemens PLM believes that the problem you reported where The number of sheets is not correct after using Orient View Tool will be resolved by code changes made to the upcoming release of our software NX 10. |
1975136 |
Siemens PLM believes that the problem you reported where The number of sheets is not correct after adding a detail view will be resolved by code changes made to the upcoming release of our software NX 10. |
1975445 |
Siemens PLM believes that the problem you reported where "Plot Thickness contour results are wrong at fillet location" will be resolved by code changes made to the upcoming release of our software NX 10.The slight difference in thickness can happen when computing thickness at nodes on boundary. To avoid this issue, in NX 10, we introduced additional option in "Mesh associated" where user can select thickness at element CG. Using this option, gave 10mm constant thickness on entire model. |
1975481 |
Siemens PLM believes that the problem you reported where Layer of KSYS is changing automatically if feature replay is chosen will be resolved by code changes made to the upcoming release of our software NX 10. |
1975591 |
Siemens PLM believes that the problem you reported where the vector block gives the wrong direction in some scenario when you change the work part after the dialog has already been activated will be resolved by code changes made to the upcoming release of our software NX 10. |
1975612 |
Siemens PLM believes that the problem you reported where Performance - Edit Object Display in NX 8.5 bad will be resolved by code changes made to the upcoming release of our software NX 10. |
1975736 |
Siemens PLM believes that the problem you reported where Internal error on delete/add component will be resolved by code changes made to the upcoming release of our software NX 10. The problem where "Internal error on delete/add component" is fixed in NX 10 phase 18. The part corruption was caused by failing to convert pre-NX3 sequence steps in part files to modern sequence steps. This corruption would have occurred because parts were partially loaded in a previous (post-NX 2) release and the sequences and sequence steps were unloaded and so not available for conversion. The part files could then be saved, and the opportunity to perform sequence step conversion was missed. This is now anticipated, and sequence steps are converted even if the last saved release was later than NX 2. |
1975918 |
Siemens PLM believes that the problem you reported where turn finishing operations generated different tool paths in NX9 compared to former versions of NX will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 10. The fix is also submitted to NX 9.0.1 MP2. As agreed by product management and our customer, the desired behavior reproducing the Finish Turn operation tool paths in question is solely available for now when an environment variable has been defined. Its name is: UGII_TURN_DIRECT_ENGAGE_AND_RETRACT_ALSO_IF_CONTAINMENT_HAS_TRIM_PLANES_ONLY (only needs to be defined and does not require a specific value). |
1976387 |
Siemens PLM believes that the problem you reported where Delete Face/Cap Face option cannot delete as in NX8.5 will be resolved by code changes made to the upcoming release of our software NX 10. |
1976448 |
Siemens PLM believes that the problem you reported where "Undetected Collision in ZLevel 5-Axis" will be resolved by code changes made to the release of our product NX 10 and future MP release of NX 9.0.3. |
1976453 |
Siemens PLM believes that the problem you reported where Thicken gives incorrect result for surface from degree 3 spline will be resolved by code changes made to the upcoming release of our software NX 10. |
1976459 |
Siemens PLM believes that the problem you reported where Sketch constraints reports wrongly as blanked object in check mate checker will be resolved by code changes made to the upcoming release of our software NX 10. Please note that doing an invert will not show the constraints of an inactive sketch. The user must activate the sketch to unblank the constraints in them. |
1976465 |
Siemens PLM believes that the problem you reported where the NXOpen::Builder::Destroy() description breaks off mid-sentence will be resolved by code changes made to the upcoming release of our software NX 10. The fixed comment is: Deletes the builder, and cleans up any objects created by the builder. This method should always be called when a builder has been committed or is no longer needed. |
1976565 |
Siemens PLM believes that the problem you reported where the JT Doc isn't clear - what means "Awaiting info from SME"? will be resolved by code changes made to the upcoming release of our software. The specified problem is already fixed and the changes will appear in the NX 10 documentation. |
1976583 |
Siemens PLM believes that the problem you reported where the JT Documentation style and fonts are not consistent will be resolved by code changes made to the upcoming release of our software. The problem where the formatting was not consistent is fixed in release NX 10. Intentionally retained the difference in font of inverted commas at some of the locations to differentiate between the text from code and normal text. |
1976653 |
Siemens PLM believes that the problem you reported where the problem of "Resize Bend Angle" will be resolved by code changes made to the upcoming release of our software NX 10. |
1976655 |
Siemens PLM believes that the problem you reported where "Resize Bend Angle" failed by different angle will be resolved by code changes made to the upcoming release of our software NX 10. |
1976658 |
Siemens PLM believes that the problem you reported where Layer and Color detail selection filters do not work for Exact and Smart Lightweight views, will be resolved by code changes made to the upcoming releases of our software NX 9.0.3 and NX 10. |
1976788 |
Siemens PLM believes that the problem you reported where Custom shortcut not working will be resolved by code changes made to the upcoming release of our software NX 10. This version will be available for customer download from 23-Dec-2014. |
1977050 |
Siemens PLM believes that the problem you reported where Helix failed by value along spine will be resolved by code changes made to the upcoming release of our software NX 10. The original tolerances were too tight. We have enhanced our function in NX 10 to deal with it. But suggest the user to apply a reasonable tolerance in NX 8.5 or NX 9 as a workaround such as 0.001mm as distance tol and 0.1 degree as angle tol. |
1977110 |
Siemens PLM believes that the problem you reported where Routing: Insert flange-flange connection moves first flange instead of second on will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3 + HF and MP5 and higher MPs and NX 10. |
1977126 |
Siemens PLM believes that the problem you reported where Routing: Flange flange connection does not move second flange when path exists will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3 + HF and MP5 and higher MPs and NX 10 |
1977164 |
Siemens PLM believes that the problem you reported where Recording "Analyze Formability One Step" creates thousands of Journal code lines will be resolved by code changes made to the upcoming release of our software NX 10. |
1977206 |
The problem where "Save As New Item Type" is not inherit the attributes has been investigated and the following has been found. When doing a SaveAs New Item Type, the new part will be in a different mapping context from the original one (due to its item type change), the Pdm-based attributes from the original part will not be inherited to the new part in this case. This is now the behavior started in NX 8. This is because in pre-NX 8, attributes are always treated as of "string" data type, but started in NX8, attributes are supported with their actual data type as defined in TC database, e.g. integer, string, double, .etc. As a result, attributes of the same title but from different mapping context can have different data types as their underlying mapping definitions are different. On the other hand, for SaveAs New Item or SaveAs New ItemRevision, the new part is still in the same mapping context as that of the original part, therefore, the PDM-based attributes can still be inherited in the new part. The problem where "Save As New Item Type" is not inherit the attributes is fixed in NX 10. This version will be available from 23-Dec-2014. |
1977362 |
Siemens PLM believes that the problem you reported where the Customer default MW_EW_DISPLAY_RENAME_DIALOG is not honored for 'Copy Electrode' will be resolved by code changes made to the upcoming release of our software NX 10. |
1977370 |
Siemens PLM believes that the problem you reported where solving a specific model which includes a 'pload4' pressure load applied to a number of polygon faces fails during the export of the nx Nastran .dat file with the following error written to the nx information window: ERROR : Global Exception caught by Export Export terminated because of error will be resolved by code changes made to the upcoming release of our software NX 10. |
1977518 |
Siemens PLM believes that the problem you reported where wave links break to ug_component upon update will be resolved by code changes made to the upcoming release of our software NX 10. There are some KF classes that are not able to support Update For External Change. The class ug_component is one of them because they do not participate in UPDATE as do other NX objects. Code was added to disable this function for ug_component. |
1977529 |
Siemens PLM believes that the problem you reported where an automatic stitch edge gives partial result: imprint done, but edges not stitched will be resolved by code changes made to the upcoming release of our software NX 10. |
1977549 |
Siemens PLM believes that the problem you reported where "Deformed shape is impossible with Relative displacement in NX Post" will be resolved by code changes made to the upcoming release of our software NX 10. |
1977665 |
Siemens PLM believes that the problem you reported where You Cannot save imported Parasolid assembly, will be resolved by code changes made to the upcoming release of our software NX 10. |
1977693 |
Siemens PLM believes that the problem you reported where "View Break edit fails with Extracted Edges on" will be resolved by code changes made to the upcoming release of our software NX 10. |
1977703 |
Siemens PLM believes that the problem you reported where "Relabelling nodes makes MPC having memory and conflict issue" will be resolved by code changes made to the upcoming release of our software NX 10. |
1977711 |
Siemens PLM believes that the problem you reported where The display of the Orient Express axes are inconsistent when using 'Move Object' will be resolved by code changes made to the upcoming release of our software NX 10. |
1977712 |
Siemens PLM believes that the problem you reported where Routing assemblies (with gaskets/bolts/nuts) created with NX6 show erroneous will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3 + HF and MP5 and higher MPs and NX 10. |
1977737 |
Siemens PLM believes that the problem you reported where udos have no links to NX Routing connections will be resolved by code changes made to the upcoming release of our software NX 8.5.3 MP3 + HF and MP5 and higher MPs and NX 10. |
1977751 |
Siemens PLM believes that the problem you reported where "Long time to edit parameters in Volume Milling" will be resolved by code changes made to the release of our product NX version 10 |
1977944 |
Siemens PLM believes that the problem you reported where NX hangs during stitching edge to face will be resolved by code changes made to the upcoming release of our software NX 10.0 |
1978016 |
Siemens PLM believes that the problem you reported where an analysis of a model which includes a 'simple radiation to environment' boundary condition based upon the 'radiative ambient' temperature gives a different result from the same model analyzed with a 'simple radiation to environment' boundary condition based upon a 'specified' temperature will be resolved by code changes made to the upcoming release of our software NX 10. |
1978053 |
Siemens PLM believes that the problem you reported where Opening drawing with partial loading enabled causes NX to crash will be resolved by code changes made to the upcoming release of our software NX 10. |
1978089 |
Siemens PLM believes that the problem you reported where editing an annotation in a read-only part triggers "A tag was passed..." error will be resolved by code changes made to the upcoming release of our software NX 10. |
1978139 |
Siemens PLM believes that the problem you reported where NX hang - poor performance in meshing or remeshing - no remeshing? will be resolved by code changes made to the upcoming release of our software NX 10. |
1978142 |
Siemens PLM believes that the problem you reported where FE Nodes can't be picked with a Block Styler "Specify Point" block in NX 9 will be resolved by code changes made to the upcoming release of our software NX 10. As the PR text points out, in NX 9 the SpecifyPoint block now correctly identifies and enforces the selection scope. By default, the selection scope for the SpecifyPoint widget is Within Work Part Only. Since the FEM entities have been occurrenced into the Simulation, there are no prototype nodes in the Simulation. The proper scope for a Simulation in this scenario is to use Entire Assembly. The SpecifyPoint Block wrt to CAE parts was reworked in NX 10 to extend the selection scope when you now set the InterpartSelection toggle. After the fix, here is what the new vb code looks like in order to allow snapping to nodes: Line 53: Was Private point0 As NXOpen.BlockStyler.UIBlock Now Private point0 As NXOpen.BlockStyler.SpecifyPoint Line 236: Was point0 = CType(theDialog.TopBlock.FindBlock("point0"), NXOpen.BlockStyler. UIBlock) Now point0 = CType(theDialog.TopBlock.FindBlock("point0"), NXOpen.BlockStyler.SpecifyPoint) Added line 237: point0. InterpartSelectionAsString= " Associative and Non-associative Interpart Copy" It now works for the CAE selection of nodes. |
1978191 |
Siemens PLM believes that the problem you reported where Null tag error in assembly drawing will be resolved by code changes made to the upcoming release of our software NX 10. The problem where an error occurs when displaying a drawing containing exact views with Wireframe Color Source set to From Face after deleting a component from the model has been fixed for NX 9.0.3 and NX 10. |
1978229 |
Siemens PLM believes that the problem you reported where 2D Exchange exports DXF with wrong dimension placement will be resolved by code changes made to the upcoming release of our software NX 10. |
1978288 |
Siemens PLM believes that the problem you reported where you can't get the text of embedded Custom Symbol in PMI Note using NX Open will be resolved by code changes made to the release of our product NX 10.A new NXOpen method NXOpen::Annotations::TextWithSymbolsBuilder::GetEmbeddedCustomSymbols() is provided in NX 10.0 to get the embedded custom symbols. See the NX Open documention for more details. The API can't be back ported to previous releases. |
1978482 |
Siemens PLM believes that the problem you reported where a ugmanager_import has an ERROR while setting the Teamcenter names - aborting import will be resolved by code changes made to the upcoming release of our software is fixed in NX 10. |
1978629 |
Siemens PLM believes that the problem you reported where "Multiple Routing Sweep is not working as expected" will be resolved by code changes made to the release of our product NX 10. |
1978631 |
Siemens PLM believes that the problem you reported where "Existing Sew vs new Sew or Sheet Body vs Solid Body" will be resolved by code changes made to the upcoming release of our software NX 10.In addition: I have made a ppt to explain this issue in details, please refer to that PPT. "Why sewing sheets can generate a solid body and a fix for this PR.pptx" There's no problem of sew feature. A fix is also proposed in the PPT from customer's perspective. You may create either a solid or sheet body in this case. Close as FN. If you have further questions, please let me know. |
1978891 |
NX 10 will have several enhancements to improve the performance and usability of the Replace Feature operation. Some enhancements are already available in NX 9.0.3 while some are in NX 10 only. The following aspects of Replace Feature workflow have been performance-enhanced in NX 10: 1. Generating the list of parent references to map from dependent features. 2. Automatic geometric matching of parent references. 3. Manual mapping and selection of the unmapped parent references. 4. List interactions and highlighting of references to map. 5. Applying the replacement mapping and model update after replace. As of NX 10, the PR complaints have been addressed from NX development perspective unless we hear otherwise from Daimler representatives. Please test this PR during the upcoming NX 10 D-Test-2. |
1978961 |
The problem where "Save As New Item Type" is not inherit the attributes is fixed in NX 10. |
1978968 |
Siemens PLM believes that the problem you reported where "3D swept mesh quality is not correct" will be resolved by code changes made to the release of our product NX 10. |
1979062 |
Siemens PLM believes that the problem you reported where "a memory access violation occurs when trying to save a motion file with jt data" will be resolved by code changes made to the upcoming release of our software NX 10. |
1979101 |
Siemens PLM believes that the problem you reported where you get "...session may be corrupt" error while closing assembly drawing will be resolved by code changes made to the upcoming release of our software NX 10. |
1979130 |
Siemens PLM believes that the problem you reported where Import Results File with Long Path gives Error will be resolved by code changes made to the upcoming release of our software NX 10. |
1979324 |
Siemens PLM believes that the problem you reported where "NX Open SetUserAttribute does not work with Number-Type Properties" will be resolved by code changes made to the upcoming release of our software NX 10.0 Backports are being considered. |
1979366 |
Siemens PLM believes that the problem you reported where Error when copy and paste in modeling will be resolved by code changes made to the upcoming release of our software NX 10. Your can download a movie here: http://download.industrysoftware.automation.siemens.com/special.php/returned/PR 1979366_NX 10-clean.avi.7z |
1979377 |
Siemens PLM believes that the problem you reported where even when suppressing a feature through an expression, PMIs are shown in the exported JT, will be resolved by code changes made to the upcoming release of our product NX 10. |
1979403 |
Siemens PLM believes that the problem you reported where No Dimension to Sketch Origin will be resolved by code changes made to the upcoming release of our software NX 10. The problem where dimension option was not available when selecting a line and sketch origin has been fixed in NX 10. "Perpendicular Dimension" option will now be available for this specific selection combination. |
1979410 |
The problem where Undefined Naming of Source-Part in Relation Browser with NX TC Integration is fixed in release NX 10. |
1979618 |
Siemens PLM believes that the problem you reported where "Measure Distance Annotation setting changes after pressing F5" will be resolved by code changes made to the upcoming release of our software NX 10. Because: Prior to NX 10 the show dimension option was used a bit inconsistently, and was trying to indicate if the measurement dimension was currently on screen as well as whether the dimension should be shown when Ok/Apply was pressed. Meanwhile, F5 clears temporary geometry, and the measurement dimensions are temporary geometry which makes it more complicated. In NX 10 the show dimension option is now a check box so that it does not share the feedback choices with the construction of geometry. That combined with a change so that the logic has been simplified to make it more reasonable. |
1979752 |
Siemens PLM believes that the problem you reported where Continuos Dimensioning is not honored in standard Flange Sketch will be resolved by code changes made to the upcoming release of our software NX 10. Continuous Auto Dimensioning setting will now be honored for the new Flange features. |
1979824 |
Siemens PLM believes that the problem where legacy line widths are not mapped based on environment variables is fixed for drafting dialogs. Now all drafting dialogs will show mapped new width for legacy width. Legacy widths will be mapped based on following environment variables. UGII_CONVERT_LEGACY_THIN_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_NORMAL_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_THICK_LINEWIDTH_TO_NEW_LINEWIDTH This problem is fixed in NX 10. This fix is back ported in following MPs. NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP. |
1979866 |
Siemens PLM believes that the problem you reported where Adding part to assembly, part disappears from preview window during constraining will be resolved by code changes made to the upcoming release of our software NX 10. |
1979902 |
Siemens PLM believes that the problem you reported where Critical Problem with mirroring features will be resolved by code changes made to the upcoming release of our software NX 10. |
1979980 |
Siemens PLM believes that the problem you reported where Deletion of copied Part Module not possible will be resolved by code changes made to the upcoming release of our software NX 10. |
1980026 |
Solution: Use C# FileStream to export data instead of NXOPEN Session to avoid dotNet check. |
1980324 |
Siemens PLM believes that the problem you reported where SB Closed Corner works not similar on two similar edges will be resolved by code changes made to the upcoming release of our software NX 10. |
1980375 |
Siemens PLM believes that the problem you reported where Documentation gives wrong information about cell protection will be resolved by code changes made to the upcoming release of our software NX 10. |
1980390 |
Siemens PLM believes that the problem you reported where Angle dimension failed will be resolved by code changes made to the upcoming release of our software NX 10. The issue that would occur in some cases where an angular dimension could not be created to the extension line of a linear dimension with tangent associativity has been fixed in NX 10. This issue would result in an error stating that the object did not have a matrix and was specific to angular dimension to the extension of another non-angular dimension. |
1980468 |
Siemens PLM believes that the problem you reported where "Missing Annotation Origin Feature when Adopting a Title Block" will be resolved by code changes made to the release of our product NX 10. |
1980542 |
Siemens PLM believes that the problem you reported where the toolpath direction was reversed in certain turning operations will be resolved by code changes made to the release of our product NX 8.5.3 MP7 Delta. The toolpath is generated in the correct direction again. In your part's first operation 'ROUGH_TURN_OD', our solution for MP7 may still come up with an unjustified "collision warning message". Just choose "Direct" then, in order to obtain a direct approach to your engage move for this operation, like it was made in your former correct version. This redundant message will go away with our next software update! |
1980819 |
Siemens PLM believes that the problem you reported where "Smooth edges are shown in an Exact Section View unexpectedly" will be resolved by code changes made to the upcoming release of our software NX 10. First edit applied on the smooth edge was incorrect. Fist edit was non smooth. So the whole edge was treated as visible edge instead of smooth edge. Fixed code to apply proper edit on edge. |
1980900 |
Siemens PLM believes that the problem you reported where a Condition Sequence Parameter can't be created with correct measure type will be resolved by code changes made to the upcoming release of our software NX 10. |
1980982 |
Siemens PLM believes that the problem you reported where a routing part library .Net program crashes will be resolved by code changes made to the release of our product NX 8.5.3 MP6 and NX 10.The problem with the performance issue remains and a separate ER to track the performance problem needs to be opened. To address the performance problem, enhancements of the NX Open API will be required. |
1981001 |
Siemens PLM believes that the problem you reported where "NX 9 OpenC API UF_DRAW_ask_sxsolids_of_sxview doesn't work when Exact view used" will be resolved by code changes made to the release of our product NX 10. |
1981130 |
The problem where "Flat Pattern has missing holes for a circular pattern hole feature" is fixed in NX 10. |
1981133 |
Siemens PLM believes that the problem you reported where "Explosion of deformable feature in assembly failed" will be resolved by code changes made to the upcoming release of our software NX 10. |
1981178 |
Siemens PLM believes that the problem you reported where the Dimension on hole datum symbol is wrong will be resolved by code changes made to the upcoming release of our software NX 10 (only for new holes). |
1981221 |
Siemens PLM believes that the problem you reported where System crash after using the option Tools -> Expression will be resolved by code changes made to the upcoming release of our software NX 10. |
1981353 |
Siemens PLM believes that the problem you reported with definition of center in closed corner will be resolved by code changes made to the upcoming release of our software NX 10. The CloseCorner feature needs to be re-created in NX 10. |
1981363 |
Siemens PLM believes that the problem you reported where Section line segment no more selectable after clicking "Apply" will be resolved by code changes made to the upcoming release of our software NX 10. |
1981549 |
The Check-Mate "Tiny solid:G-SO-TI" checker in the SASIG-PDQ Solid category has been enhanced to log additional messages to indicate that the solid mass property check fails when the test part has model errors. This problem is fixed in release NX 10. |
1981631 |
Siemens PLM believes that the problem you reported where "Edit Feature Playback failed in higher version NX 9.0.1.3 D1 for A2386361300" will be resolved by code changes made to the upcoming release of our software NX 9.0.3.1. EB136 is fixed in NX 9.0.3.1 using ps26.1.221 as stated above. However, the original part seems to be unstable. Part successfully replays one time, but fails on the next replay. Cannot determine the cause of the instability in nx9031; when I replay the part multiple times in will fail somewhere. I did clean and update the part in the last saved version of the part, NX 8.5.2.3. That updated part is called: A2386361300_2_cleanded_updated_nx8523.prt The updated part works correctly in NX 9.0.3.1 and NX 10.15 and seems stable, ie. I replayed it 10 times in each version and no failures. Going to close the part as fixed, however the updated part should be used in the future. |
1981846 |
Siemens PLM believes that the problem you reported where "Gouge Issue in "Z-LEVEL 5 Axis" when Tool Offset Insertion is Defined in Holder" will be resolved by code changes made to the release of our product NX 10 and future MP release of NX 9.0.3. |
1981944 |
Siemens PLM believes that the problem you reported where "GD&T (Datum Feature Symbol) not correctly exported to DWG" will be resolved by code changes made to the upcoming release of our software NX 10. |
1982012 |
Siemens PLM believes that the problem you reported where Stud and Surfacing weld not displaying correctly in Weld symbol dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
1982299 |
Siemens PLM believes that the problem you reported where some column names are missing from the documentation will be resolved by code changes made to the upcoming release of our software NX 10. Updated the NX 10 Modeling Help documentation topic "Standard data tables for Hole Features", to add the following entries to the column names in the NX 502_Threaded_Hold_Standard.xml file" section of the table: *ScrewStandard - Specifies the standard that defines the options and parameters used to create the screw clearance hole. *ScrewType - Included here with a default value for a Screw Clearance Hole, in case the hole Type is changed in the Hole dialog box from Threaded Hole to Screw Clearance Hole. The available options in the Screw Type list depend on whether Form is set to Simple, Counterbored, or Countersunk. *ScrewSize - Included here with a default value for a Screw Clearance Hole, in case the hole Type is changed in the Hole dialog box from Threaded Hole to Screw Clearance Hole. Specifies the screw size for the selected Screw Type used to create a Screw Clearance Hole. *ScrewFit - Included here with a default value for a Screw Clearance Hole, in case the hole Type is changed in the Hole dialog box from Threaded Hole to Screw Clearance Hole. Specifies the required Fit parameter for a Screw Clearance Hole. NX 10 will be ready for customer download from 23-Dec-2014. |
1982309 |
Siemens PLM believes that the problem you reported where 2D Section template containing joined curves locks pole position on placement will be resolved by code changes made to the upcoming release of our software NX 10.The problem is only fixed for new splines created in that version. For existing splines (like the PR case), the user needs to do a NULL edit to upgrade the spline to new spline and after that, the spline can be moved without getting deformed. |
1982339 |
Siemens PLM believes that the problem you reported where selecting a feature group containing measurements causes all measurements to display will be resolved by code changes made to the upcoming release of our software NX 10. |
1982370 |
Siemens PLM believes that the problem you reported where a Reference dimension cannot be hidden on mirror feature will be resolved by code changes made to the upcoming release of our software NX 10. |
1982413 |
Siemens PLM believes that the problem you reported where "Incorrect results converting PMI drawings with UGto2D translator" will be resolved by code changes made to the upcoming release of our software NX 10. |
1982478 |
Siemens PLM believes that the problem you reported where SB Resize Bend Angle does not work for specific values will be resolved by code changes made to the upcoming release of our software NX 10. In NX 10 , all other value ranges work fine except "99.6° - 95.8°". The reason why the bend could not be changed angle to "99.6° - 95.8°" is because this value angel is too close to its original bend angle. A workaround is available to make this change. 1.) Resize Bend Angle to a bigger or smaller angle, i.e. 90 degree, 2.) Resize Bend Angle again to desired angle, i.e. 98 degree will succeed. |
1982671 |
The problem where "RESIZE BEND ANGLE: Changing to some value ranges is not possible" is fixed in NX 10. |
1982713 |
Siemens PLM believes that the problem you reported where "Feature Playback from part fmsr_48851e8e04a711e3b01a3c4a927874ee----.prt results in error in NX9 will be resolved by code changes made to the release of our product NX 10. |
1982789 |
The problem where hiding of a nested custom symbol while edit the symbol is not possible is working as designed. You cannot use invisible objects to create or edit master symbol definitions. The following note was added to the overview information in the Drafting Help NX 10 for both the Define Custom Symbol and Edit Custom Symbol commands: "Only visible objects are used to define a master custom symbol. While creating or editing a master custom symbol, if objects are on an invisible layer, or are hidden, they will not be added to the master custom symbol definition." |
1982797 |
Siemens PLM believes that the problem you reported where "defective format in information window" will be resolved by code changes made to the upcoming release of our software NX 10. |
1982834 |
The problem where imported drawing template did not have drawing borders is fixed in NX 10. |
1982953 |
Siemens PLM believes that the problem you reported where Changing line widths does not work for drafting objects will be resolved by code changes made to the release of our product. The problem where legacy line widths are not mapped based on environment variables is fixed for drafting dialogs. Now all drafting dialogs will show mapped new width for legacy width. Legacy widths will be mapped based on following environment variables. UGII_CONVERT_LEGACY_THIN_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_NORMAL_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_THICK_LINEWIDTH_TO_NEW_LINEWIDTH This problem is fixed in NX 10. This fix is back ported in following MPs. NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP. |
1982994 |
Siemens PLM believes that the problem where radials and popup menus appear in the incorrect position when running with Windows text settings greater than 100% is fixed in release NX 9.0.3 and NX 10.There is also a workaround to the issue prior to these releases. On the NX executable, right-click and select Properties. Select the Comparability tab and toggle the option for "Disable display scaling on high DPI settings" NX 9.0.3 will be ready for customer download from 30-Sep-2014. NX 10 will be ready for customer download from 23-Dec-2014. |
1983028 |
Siemens PLM believes that the problem you reported where Sheetmetal rebend is not working will be resolved by code changes made to the upcoming release of our software NX 10. |
1983046 |
Siemens PLM believes that the problem you reported where ""evcrvu.c: Unknown curve type" appears when updating drawing view" will be resolved by code changes made to the release of our product NX 10. |
1983059 |
The problem where no Journal Automation for "File -> Force Save All" is available although the method "NXOpen -> PartCollection -> ForceSaveAll()" exists will be solved by code changes made to the upcoming release of our software NX 10. |
1983153 |
Siemens PLM believes that the problem you reported where installation script fails with an "arithmetic syntax error", will be resolved by code changes made to the upcoming release of our software NX 10. Follow explanation and possible WA: The script code at line 2557 did not perform arithmetic correctly on a decimal number (i.e. 9.0). The result was truncated to a simple integer (i.e 27). No fix for NX 9 as the DVD is already out in the field. Workarounds for NX 9: For a single install, simply edit the /ugs/installed_programs.dat to change "27" to "27.0". For multiple installs, edit the install script and change line 2557: From: UG_VER="$(($NX_VER + 18))" To: UG_VER="27.0". |
1983159 |
Siemens PLM believes that the problem you reported where a number of significant performance issues were encountered when using NX 7.5.5 with a model which included many groups and laminates will be resolved by code changes made to the upcoming release of our software NX 10. |
1983162 |
Siemens PLM believes that the problem you reported where laminate 'compute zone' performance is slower in NX 9.0.1 than NX 7.5.5, and slower again when using 'edit in context' (NX 9.0.1), will be resolved by code changes made to the upcoming release of our software NX 10. |
1983192 |
Siemens PLM believes that the problem you reported where Dimensions and labeled tabular note not correctly translated to DWG will be resolved by code changes made to the upcoming release of our software NX 10. |
1983371 |
Problem where some customer defaults settings are not correctly loaded "From Search folders" as Assembly Load Options is fixed in NX 10. |
1983487 |
Siemens PLM believes that the problem you reported where custom attributes in tooldata for export tools disturbs NX Tool Creation will be resolved by code changes made to the upcoming release of our software NX 10. |
1983522 |
Siemens PLM believes that the problem you reported where the toolpath direction was reversed in a roughing operation machining multiple cut regions in a single setting will be resolved by code changes made to the release of our product NX 8.5.3 MP7 Delta. The toolpath is generated in the correct direction again! However, it is required that you correct two input parameters in order to obtain the same cutting motions as before: a) Select "Cutting Parameters -> Profiling(tab) -> Path Settings -> Strategy = Finish All" (...which is the correct setting for your Level Angle specified) b) Increase your Cut Depth value to "Maximum = 6 mm" (...otherwise, the system generates two rough cuts in addition to the profiling pass). |
1983852 |
Siemens PLM believes that the problem you reported where new instances in Teamcenter with mirror transformations would be loaded in NX without any message to the user has been fixed. Since NX does not support mirror or other non-rigid body transforms coming directly from Teamcenter, components with such transforms are placed in NX at either their internal NX part file transform (for existing components) or at the origin (for new components). In either case a warning message should be displayed to the user to this effect. This fix makes sure the message is displayed for both new and existing components. The fix will appear in NX 10. |
1983861 |
Siemens PLM believes that the problem you reported where NX crashes when import merge of HRN file into electrical connection navigator will be resolved by code changes made to the upcoming release of our software NX 9.0.2 Rev A, NX 9.0.3 and NX 10. |
1983896 |
Siemens PLM believes that the problem you reported where Rebend failed will be resolved by code changes made to the upcoming release of our software NX 10. Note: to verify the fix, the last 2 unbend features need to be update by (either suppress/unsuppress or feature playback), then rebend will succeed. |
1984157 |
Siemens PLM believes that the problem you reported with wrong behavior of File Open when advanced search is uses will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014. |
1984306 |
Siemens PLM believes that the problem where legacy line widths are not mapped based on environment variables is fixed for drafting dialogs. Now all drafting dialogs will show mapped new width for legacy width. Legacy widths will be mapped based on following environment variables. UGII_CONVERT_LEGACY_THIN_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_NORMAL_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_THICK_LINEWIDTH_TO_NEW_LINEWIDTH This problem is fixed in NX 10. This fix is back ported in following MPs. NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP. |
1984417 |
Siemens PLM believes that the problem you reported where Face Blend works or not if the target and tool is permuted will be resolved by code changes made to the upcoming release of our software NX 10. Before NX 10, Face Blend works on Master face concept, where in the first face for both the wall chains needed to be same to keep the result consistent when the wall chain faces are permuted. This drawback has been enhanced by a recent project in Face Blend and the new functionality is available in NX 10 and later version. If the Face Blend is created in NX 10, the user should see same result when the wall chain 1 and 2 faces are interchanged. Since this was an enhancement to the existing face blend functionality, it cannot be backported to an earlier NX version. |
1984646 |
Siemens PLM believes that the problem you reported where Feature Playback failed in NX 9 will be resolved by code changes made to the upcoming release of our software NX 10. This version will be ready for customer download from 23-Dec-2014. |
1984703 |
Siemens PLM believes that the problem you reported where Feature Playback failed in NX 9 for MFA_RB@0000001865_1.prt will be resolved by code changes made to the upcoming release of our software NX 10. |
1984807 |
Siemens PLM believes that the problem you reported where the Help text in customer defaults uses term Locking policy and not check in policy will be resolved by code changes made to the upcoming release of our software NX 10. |
1985045 |
Siemens PLM believes that the problem you reported where Performance Issue when changing length of Stiffener will be resolved by code changes made to the upcoming release of our software. The problem where changing the length of a stiffener triggered an update of the entire assembly has been fixed in NX 10. The PR parts cannot be fixed. The customer should be given a best practice to create corner cuts and similar features prior to applying Profile Cutouts to avoid unneeded updates. Additional information send to responsible SPLM employee. |
1985061 |
Siemens PLM believes that the problem you reported where Copy parts between planes Performance is slow will be resolved by code changes made to the release of our product NX 10. |
1985105 |
Drill Operation will not simulate correctly when Rtrcto is set to Auto. |
1985133 |
The problem where Missing information about out of date status, is fixed in NX 10. |
1985134 |
Siemens PLM believes that the problem you reported where Part updates during loading will be resolved by code changes made to the upcoming release of our software NX 9.0.3. This version will be ready for customer download from 09-Sep-2014. |
1985273 |
Siemens PLM believes that the problem you reported where "(Von_mises results)^2 through results Manipulation, are not correct" will be resolved by code changes made to the upcoming release of our software NX 10. |
1985313 |
The problem where a leader attached to the text on top of a Feature Control Frame, instead of to the Feature Control Frame, is fixed in NX 10. |
1985351 |
The problem where the part goes out-of-date when replacing reference set on a component with delay inter part updates turned on has been fixed in NX 10. The problem is specific to certain kinds of broken structure dependent inter part links - where the link is broken because components or sub-assemblies were deleted from the structure, but other parts of the structure are still valid. In addition, after the link is broken because of these structure changes, one of the remaining components should have a change in position. |
1985352 |
This PR shows that when editing Weld Points the End Distances are not retained. This problem has been fixed in NX 10 with the Weld Point Wizard dialog. |
1985411 |
The NX was hanging because of large number of elements (>100000) is reflected (i.e. created) one by one. New performance improvement code is added to element creation which reduced the creation time from 1400+ seconds to 20 seconds for customer model. The new performance improvement code is added in NX 10. |
1985538 |
Siemens PLM believes that the problems you reported where: 1 - laminate ply component stresses are plotted incorrectly when displayed as tensors within post-processing and 2 - component stresses on shell elements which reference an isotropic material are plotted incorrectly when the stresses are plotted with respect to the native (element) coordinate system within post-processing will be resolved by code changes made to the upcoming release of our software NX 10. |
1985561 |
Siemens PLM believes that the problem you reported where "Wrong Major Diameter is inherited from customized thd_metric.dat file" will be resolved by code changes made to the upcoming release of our software NX 10. |
1985752 |
Siemens PLM believes that the problem you reported where "Unable to create View Break" will be resolved by code changes made to the upcoming release of our software NX 10. |
1985896 |
Siemens PLM believes that the problem you reported where Nested CustomSymbols show all options at the same time will be resolved by code changes made to the upcoming release of our software NX 10. |
1985962 |
Siemens PLM believes that the problem you reported where NX 9 - NX Open: CreateFlangeFeatureBuilder leads to corrupt NX Session will be resolved by code changes made to the upcoming release of our software NX 10. |
1986149 |
Siemens PLM believes that the problem you reported where it is possible to encounter an apparent software 'hang' when using the 'import layup from spreadsheet' function on the laminates 'layup modeler' form will be resolved by changes made to the help documentation in the upcoming release of our software NX 10. Specifically, the help documentation for NX 10 has been improved to let the user know that when using the 'import layup from spreadsheet' function on the laminates 'layup modeler' form, the user must copy the layout from the imported spreadsheet to the opened worksheet. |
1986211 |
For the provided assembly it wasn't possible to determine a root cause that causes that 'problematic' CSYS, for this assembly the only way to fix the corrupted wave linked CSYS is to edit it (as already reported by the customer); moreover the customer wasn't able to provide a workflow, i.e. some steps that starting from a working model generates such a kind of corrupted CSYS, so it wasn't possible for dev. to detect any kind of possible bugs existing in NX. However we found (for another PR) one workflow which can lead to such a corruption, exactly like the reported PR case and we believe this might be the root cause even of this PR. We have fixed this root cause in NX 10. Thus, close this PR as FN against NX 10. |
1986312 |
Siemens PLM believes that the problem you reported where "Wrong Major Diameter is inherited from customized thd_metric.dat file" will be resolved by code changes made to the upcoming release of our software NX 10. |
1986329 |
Siemens PLM believes that the problem where the Assemblies Help needed more information about how the reference sets used to load child components can vary based on which reference set their immediate parent is using is fixed in release NX 10. Additional information has been added to the Reference Sets section in the documentation. |
1986344 |
Siemens PLM believes that the problem you reported where "Unable to Simulate a Toolpath in 3D Dynamic" will be resolved by code changes made to the release of our product NX 10. |
1986505 |
Moving the position of an RCP can cause a Routing Constraint to be lost. |
1986613 |
Siemens PLM believes that the problem you reported where an Electrode assembly drawing doesn't show the Electrode Fixture as of NX8 will be resolved by code changes made to the upcoming release of our software NX 10. |
1986727 |
Siemens PLM believes that the problem you reported where Model Setup Check does not properly validate material stress-strain data for kinematics hardening will be resolved by code changes made to the upcoming release of our software NX 10. |
1986780 |
Siemens PLM believes that the problem you reported where opening assembly in PTS took too much time will be resolved by code changes made to the upcoming release of our software NX 10. |
1986834 |
Siemens PLM believes that the problem where legacy line widths are not mapped based on environment variables is fixed for drafting dialogs. Now all drafting dialogs will show mapped new width for legacy width. Legacy widths will be mapped based on following environment variables. UGII_CONVERT_LEGACY_THIN_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_NORMAL_LINEWIDTH_TO_NEW_LINEWIDTH UGII_CONVERT_LEGACY_THICK_LINEWIDTH_TO_NEW_LINEWIDTH This problem is fixed in NX 10. This fix is back ported in following MPs. NX 8.5.2 MP7. NX 8.5.3 MP7. NX 9.0.3 latest MP. |
1986878 |
Siemens PLM believes that the problem you reported where performing an adaptive analysis of a specific model fails with the error: *** USER FATAL MESSAGE 4306 (ETR6D) DEGENERATE GEOMETRY OR INADEQUATE MATERIAL DATA SPECIFIED FOR TRIA6 ELEMENT WITH ID = 60 REASON NUMBER = 28 User information: See UFM 4288 for an explanation of reason numbers, except that Reason 28 corresponds to CODE 21. ^^^ USER FATAL MESSAGE 9031 (ERRPH1) ^^^ NOGO ENCOUNTERED IN SUBDMAP SEMG will be resolved by code changes made to the upcoming release of our software NX 10.Note that adaptively has been completely re-worked in NX 10.This example was working as expected in NX 9.0, in that if the solver fails, the adaptive process terminates. In NX 10 this example solves successfully through to completion due to functionality enhancements made to both NX adaptive mesh refinement and NX Nastran. |
1986958 |
Siemens PLM believes that the problem you reported where " NX fem is hanging with " auto stitch edge to face" (see NX file for the errors)" will be resolved by code changes made to the upcoming release of our software NX 10. |
1986994 |
Siemens PLM believes that the problem you reported where the KF function 'ug_excel_read' fails to read a named cell from a non-active sheet will be resolved by code changes made to the upcoming release of our software NX 10. The documentation for functions like ug_cell_read have been changed to cover the use of a sheet name in the cell specification so that the read is not dependent on the currently active worksheet. |
1987049 |
Siemens PLM believes that the problem you reported where more description is required for Measure Bodies - Products of Inertia has been fixed in NX 10. The Measure Bodies Information window topic has been updated. http://lmdbuild/tdoc/nx/10/nx10-nx_tdoc_collection-en_US/#uid:index_measure_ent er_values:analysis_ana_massprop_ov:analysis_ana_massprop_rt. |
1987150 |
Siemens PLM believes that the problem you reported where "File Save As command generates a large fem-file" will be resolved by code changes made to the release of our product NX 10. |
1987292 |
(MRL/NXAutoAssembly) Different names for TOOL_TIP and TOOL_MOUNT. |
1987295 |
(MRL/NXAutoassembly) TOOL_MOUNT is wrong. |
1987297 |
(MRL/NXAutoAssembly) No SIEMENS_TOOL_MOUNT. |
1987301 |
(MRL/NXAutoAssembly)TOOL_TIP and TOOL_MOUNT orientations are wrong. |
1987303 |
(NX/MRLAutoAssembly) Setup values are swapped. |
1987439 |
Siemens PLM believes that the problem you reported where mesh control settings defined using 'menu, insert, mesh, mesh control, biasing on edge' are not honoured when applied to a '3d tetrahedral mesh' will be resolved by code changes made to the upcoming release of our software NX 10. Note that this problem is a software regression in NX 9.0.1 (it does not occur in NX 8.5.3). Also note that these same settings are honoured if applied to a '2d (free) mesh', which means that this problem can be worked around by creating a thin shell element 'seed' mesh (export mesh to solver = off) on a surface whose boundary includes the appropriate edge. This seed mesh will honour the mesh control setting defined on the edge, and will drive the 3d tetrahedral mesh to do the same. |
1987464 |
Siemens PLM believes that the problem you reported where the Mold Wizard Runner UI doesn't change the workpart as defined by the PARENT definition will be resolved by code changes made to the upcoming release of our software NX 10. |
1987468 |
Siemens PLM believes that the problem you reported where part cannot be loaded will be resolved by code changes made to the upcoming release of our software NX 10. |
1987520 |
Siemens PLM believes that the problem you reported where Edit Work Section is grayed out by verfing a complete Program-Group will be resolved by code changes made to the release of our product NX version NX 10 and NX 9.0.3 MP 1. |
1987663 |
Siemens PLM believes that the problem you reported where FeaturePlayback failed in NX9 for part "Inlet Port D=92.9 DE35.prt" will be resolved by code changes made to the release of our product NX 10. This part contains several Section surfaces which have been enhanced in NX 9 and NX 10. Unfortunately, the fixes is under version control. So the original part still can't fully update itself, unless you re-do it in NX 10. I have uploaded a fixed part as "Port D-92.9 DE35_nx10.prt" \tin which I upgrade the 3 section surface (218, 219 and220) version. So you should be able to run a update without problem in NX 10. Now I'll close this PR as fixed, but sorry you have to use the NX 10 (and re-do this model.) |
1987664 |
Siemens PLM believes that the problem you reported where "Part Module: Reselection of output geometry is not possible" will be resolved by code changes made to the upcoming release of our software NX 10. |
1987688 |
Siemens PLM believes that the problem you reported where Flat Pattern bend annotations not visible when printing Sheet Metal drawings will be resolved by code changes made to the upcoming release of our softwareNX 10. The fix require object structure changes and hence cannot be ported back to a previous release. For pre-nx10 drawings to print annotations correctly in NX 10 or later, user need to follow these steps - 1. Open the drawing in NX 10 or later with full load option. 2. Update the flat pattern drafting view. 3. Save. After this, the annotations will print correctly. |
1987781 |
Siemens PLM believes that the problem you reported where Join Curve creates the wrong type due to Modeling preferences, will be resolved by code changes made to the release of our product NX 10. |
1987864 |
Siemens PLM believes that the problem you reported where: NX Crashed during post result will be resolved by code changes made to the release of our software NX 10. |
1987954 |
Siemens PLM believes that the problem you reported where "no error sign at the Offset Face" will be resolved by code changes made to the upcoming release of our software NX 10. |
1988044 |
The problem where drafting thread curves are missing a transform and therefore incorrectly displayed in new exact, revolved section views is fixed in NX 10. |
1988141 |
Siemens PLM believes that the problem you reported where "Internal error for Z-Level Operation" will be resolved by code changes made to the release of our product NX version 10 and submitted for a future MP release of NX 9.0.3. |
1988146 |
Siemens PLM believes that the problem you reported where Unable to open drawing - Object supplied is of the wrong type will be resolved by code changes made to the upcoming release of our software. The problem where error message comes "Unable to open drawing - Object supplied is of the wrong type" is fixed in nx10. |
1988437 |
Siemens PLM believes that the problem you reported where the following three articles related to 'edge to surface gluing' within the NX 9 help documentation contain erroneous references to BLSEG (the legacy nx Nastran entry for 'edge to surface glue' definitions): - Edge-to-Surface Gluing (NX Nastran) - Controlling the stiffness of edge-to-surface glue (NX Nastran) - Define edge-to-surface gluing will be resolved by code changes made to the upcoming release of our software NX 10. |
1988450 |
Siemens PLM believes that the problem you reported where, when trying to open the .op2 results file in NX after solving a specific fea model, the software displays the pop-up message: work in progress please wait for the operation to complete for about 15-20 seconds and then the following pop-up message box is displayed: result not loaded unknown error occurred will be resolved by code changes made to the upcoming release of our software NX 10. |
1988603 |
When changing to shaft, the tolerance values are not changing in Edit dialog box. |
1988941 |
Siemens PLM believes that the problem you reported where you are Unable to open drawing - The planar face cannot be projected will be resolved by code changes made to the upcoming release of our software NX 10. |
1988960 |
Mass element warning appearing in Model Setup Check. |
1989027 |
Siemens PLM believes that the problem you reported where A created Tire Envelope with NX 8.01 shows a wrong geometry in NX 8.5 or in NX 9 will be resolved by code changes made to the upcoming release of our software NX 10. |
1989071 |
Siemens PLM believes that the problem you reported where Layers without any accessible objects will be resolved by code changes made to the release of our product NX 10. |
1989093 |
The problem where error occurs attempting to replace component has been fixed in NX 10. |
1989097 |
Siemens PLM believes that the problem you reported where the User Exit "Substitute Component In" doesn't show the part from 'param' input with NX/Manager will be resolved by code changes made to the upcoming release of our software NX 10. |
1989120 |
Siemens PLM believes that the problem you reported where Reflection plane for copy and reflect not created at correct location will be resolved by code changes made to the upcoming release of our software NX 10. |
1989287 |
Siemens PLM believes that the problem you reported with a Problem with your UDF parts when you use Mirror Feature command in NX will be resolved by code changes made to the upcoming release of our software. The problem where mirror of sketch produces the wrong result is fixed in release NX 10. |
1989303 |
Siemens PLM believes that the problem you reported where Thread parameters not updated when changing form type will be resolved by code changes made to the upcoming release of our software NX 10. |
1989519 |
Siemens PLM believes that the problem you reported where attribute "DESCRIPTION" is not created is fixed and the fix is submitted to NX 10 ip16, NX 9.0.3 delta and NX 8.5.3 MP. |
1989523 |
Siemens PLM believes that the problem you reported where save aborted when saving a drawing will be resolved by code changes made to the upcoming release of our software NX 10. |
1989577 |
Siemens PLM believes that the problem you reported where inconsistent units after unsettling attribute from or not from attribute template, will be resolved by code changes made to the upcoming release of our software NX 10, NX 9.0.3 and NX 8.5.3 MP. |
1989688 |
Siemens PLM believes that the problem you reported where bridge curve shines through will be resolved by code changes made to the upcoming release of our software NX 10. |
1989720 |
Siemens PLM believes that the problem you reported where NX Refile Option -set_new_dataset_o does not work on NX Dataset from JT Dataset will be resolved by code changes made to the upcoming release of our software NX 10. |
1989736 |
Siemens PLM believes that the problem you reported where "Drawing can not be opened using assembly load options "Structure Only"" will be resolved by code changes made to the release of our product NX version NX 10 IP20. Now part will get opened properly but user need to do part cleanup once part opened. |
1989818 |
The problem that using notes in Reuse Library is not longer possible like it was in NX 6 is fixed in release NX 10. |
1989833 |
There are 2 different but related issues for this PR 1) A message is given that none of the axisymmetric are located on a valid plane ***ERROR : None of the axisymmetric, plane stress or plane strain elements are located on a valid plane. Import using an XY axisymmetric extension. 2) An invalid location was found for GRID 221 ***ERROR : Invalid location for GRID/SPOINT referenced by SPC1 . First occurrence is SPC1 1 referencing GRID/SPOINT 221 Both of these stem from the GRID locations not being on the ZX plane. Looking at GRID 221 we have GRID 221 1 286.5 -7.02-153947.29 1 Where CORD2C 1 0. 0. 0. 0. 0. 1. 1. 0. 0. and R = 286.5 THETA = -7.02-15 Z = 3947.29 This evaluates in NX to an absolute position of (286.50000000000000, -3.5102585514885554e-014, 3947.29000000000000) In NX900, checking for ZX Axisymmetric status is done by using the criteria of having a Y component as 0.0. In NX 10 a tolerance will be used to account for round-off. This will resolve both issues. The fix will be into NX 10. |
1989866 |
Siemens PLM believes that the problem you reported where the option "keep target" in trimmed sheet is causing update problems will be fixed for NX 10. The workflow described in the PR text works now as new 'important' entities are reported by Replacement Assistant for mapping. |
1989935 |
Siemens PLM believes that the problem you reported with recognition of intersecting holes (Partitial Holes) will be resolved by code changes made to the upcoming release of our software NX 10. |
1990002 |
Siemens PLM believes that the problem you reported where "Model Check does not detect missing information in joint definition" will be resolved by code changes made to the upcoming release of our software NX 10. |
1990003 |
Siemens PLM believes that the problem you reported where "after a mechanism import into a top assembly several joints only show partial associativity" will be resolved by code changes made to the upcoming release of our software NX 10. |
1990106 |
The problem where a GD&T frame doesn't appear in the preset color when a custom symbol is inserted is fixed for new annotations in release NX 10. Existing annotations with this problem can be fixed by using version up. |
1990345 |
The problem where the rough offset function produces bumpy surfaces if the offset is > 75 mm is fixed in release NX 9.0.2 mp2, NX 9.0.3 mp1 and NX 10. |
1990349 |
Siemens PLM believes that the problem you reported where "Wrong Major Diameter is inherited from customized thd_metric.dat file" will be resolved by code changes made to the upcoming release of our software NX 10. |
1990375 |
Siemens PLM believes that the problem you reported where "Internal error: memory access violation" updating a Detail View will be resolved by code changes made to the upcoming release of our software NX 10. |
1990400 |
Siemens PLM believes that the problem you reported where Corrupt part files regarding the db_part_no will be resolved by code changes made to the upcoming release of our software NX 10. This part has a value of DB_PART_NO cached in a slightly unexpected way. The system has been fixed to cope with this state in such a way that it will not show up in the user interface. There is no known workaround at present. |
1990441 |
Siemens PLM believes that the problem you reported where Deform feature can't be created on SM part,that was spitted into two bodies will be resolved by code changes made to the upcoming release of our software NX 10. |
1990469 |
Siemens PLM believes that the problem you reported where Invalid cast on Formboard.ShapeSegmentBuilder.GetLineData will be resolved by code changes made to the upcoming release of our software NX 9.0.2 MP, NX 9.0.3 and NX 10. |
1990672 |
Siemens PLM believes that the problem you reported where Move selected component failed will be resolved by code changes made to the upcoming release of our software NX 10. |
1990673 |
Siemens PLM believes that the problem you reported for failing "Blend Corner Tolerance" will be resolved by code changes made to the upcoming release of our software NX 10. |
1990701 |
The problem where Boolean Face color doesn't take the tool color when the target is a promoted is fixed in release NX 10. |
1990724 |
Siemens PLM believes that the problem you reported where "Corrupt FEM file occurred after geometry update" will be resolved by code changes made to the upcoming release of our software NX 10. |
1990740 |
Siemens PLM believes that the problem where Drawing can not be opened when 3D-PRT is missing is fixed in NX 10. Now part will get opened properly but user need to do part cleanup once part opened. |
1990757 |
Siemens PLM believes that the problem you reported where Associative Position from Standardpart in PDW will be resolved by code changes made to the release of our product NX version 10. The problem where Associative Position from Standardpart in PDW has been investigated and the following has been found. From the AVI, I guess user make a mistake for the association, if it's associative, it means the added standard part is associative with the referenced point user defined, not the position point the standard part added. So I close this PR with designed as intended. |
1990771 |
Siemens PLM believes that the problem you reported where Unable to create Section view will be resolved by code changes made to the release of our product version NX 10. |
1990788 |
The problem where DB_LP_CHECKED_BY attribute is not updated in the drafting sheet, is fixed in NX 8.5.3 MP6 and later releases. |
1990901 |
Siemens PLM believes that the problem you reported where Get "Internal error: memory access violation" removing a feature group will be resolved by code changes made to the upcoming release of our software NX 10. |
1990922 |
Siemens PLM believes that the problem you reported where Sketch Pattern Curve gives internal error running NX in Polish will be resolved by code changes made to the upcoming release of our software NX 10. |
1990989 |
Siemens PLM believes that the problem you reported where "Meshing pop up" when calling NX Open functions" will be resolved by code changes made to the upcoming release of our software NX 10. |
1991191 |
Siemens PLM believes that the problem you reported where Insert Sketch from 2D Section Library failed if the dimension is a driving dimension will be resolved by code changes made to the release of our software NX 10. |
1991225 |
Siemens PLM believes that the problem you reported where SAE Standard for Head Contour is missing in the info will be resolved by code changes made to the upcoming release of our software NX 10.This version will be ready for customer download from 23-Dec-2014. |
1991233 |
Siemens PLM believes that the problem you reported where Eyellipse and Head Contour positions don't change will be resolved by code changes made to the upcoming release of our software NX 10.This version planned for customer download 23-Dec-2014. |
1991343 |
Siemens PLM believes that the problem you reported where Check-Mate SASIG-PDQ "Embedded solid:G-SO-EM" checker reports wrong results for embedded solids will be resolved by code changes made to the upcoming release of our software NX 10. |
1991434 |
Siemens PLM believes that the problem you reported where Unable to update Part Spun Outline => circular update was detected will be resolved by code changes made to the upcoming release of our software NX 10.0.19 |
1991448 |
Siemens PLM believes that the problem you reported where NXOpen : Measure Bodies gives an Incorrect Unit in the Information Window will be resolved by code changes made to the upcoming release of our software NX 10. |
1991461 |
Siemens PLM believes that the problem you reported where Mirror Feature: result of mirrored UDF is not correct will be resolved by code changes made to the upcoming release of our software NX 10. |
1991477 |
Siemens PLM believes that the problem you reported where "Neutral Factor is NOT changed via Expressions dialog" will be resolved by code changes made to the release of our product NX 10. |
1991755 |
Siemens PLM believes that the problem you reported where "Unknown error occurred" with postprocessing results when MPC objects were used will be resolved by code changes made to the release of our software NX 10. |
1991847 |
Siemens PLM believes that the problem you reported where Linked Part Module cannot be updated will be resolved by code changes made to the upcoming release of our software NX 10. Problem where part goes out of date when parent of input datum co-ordinate system is deleted with delete child features ON in customer defaults is fixed in NX 10 Ip18. Now part will not go out of date as delete child feature ON and input datum coordinate system is also getting deleted with parent. After this linked part module can be made up to date for merge operation. |
1991875 |
Siemens PLM believes that the problem you reported where Slow opening the .sim file will be resolved by code changes made to the upcoming release of our software NX 10. |
1991907 |
Siemens PLM believes that the problem you reported where Expression 'ceil' function returns wrong values with 'Constant' units will be resolved by code changes made to the upcoming release of our software NX 10. |
1991917 |
Siemens PLM believes that the problem you reported where System crashed by "Edit Sketch" will be resolved by code changes made to the upcoming release of our software NX 10. The issue with this part where a crash would occur when attempting to edit the sketch has been fixed. To access this fix, first do part cleanup for drafting objects on the part and this will resolve the issue so the sketch can be edited. |
1991943 |
Siemens PLM believes that the problem you reported where Wrong result of pattern feature will be resolved by code changes made to the upcoming release of our software NX 10. Download the WA here: http://download.industrysoftware.automation.siemens.com/special.php/returned/PR 1991943-WA-clean.7z |
1991956 |
Siemens PLM believes that the problem you reported where "Ungenauer Maßstab einer Ausschnittsvergroesserung einer Zeichnung" will be resolved by code changes made to the upcoming release of our software NX 10. |
1992062 |
Siemens PLM believes that the problem where the information of the UGII_ROUTE_CONFIG_RULE environment variable is not documented is fixed in release NX 10.The updated information is available in NX 10. Help at the following location: Home-->CAD-->Routing Systems-->Routing configuration guide-->Setting up the Routing environment-->Common environment variables for Routing The information reads as: UGII_ROUTE_CONFIG_RULE Loads the last configuration of the part if a part fails to load because its current configured option is not found. In Teamcenter Integration for NX, to allow routing commands such as Place Part and Assign Stock to work with the Precise revision rule, you must set this environment variable to Latest Working. You can also achieve the same setting by changing the revision rule itself to Latest Working. |
1992130 |
Siemens PLM believes that the problem you reported where CatiaV5 translation fails with "expected transient xmt_txt file does not exist" will be resolved by code changes made to the release of our product NX 10 CATIAV5 Translator. |
1992153 |
Siemens PLM believes that the problem you reported where "Turning : Incorrect Material Removal when Reorient Tool Holder is used" will be resolved by code changes made to the release of our product NX version NX 9.0.3 MP1 and NX 10. |
1992166 |
Siemens PLM believes that the problem you reported where IGES did not export "mu" symbol correctly to IGES file using IGES1002 font will be resolved by code changes made to the release of our product NX 10. |
1992228 |
Siemens PLM believes that the problem you reported where the usage of the Block UI Styler 'Drawing Area' block capabilities is not clear enough will be resolved by code changes made to the upcoming release of our software NX 10. The documentation will be corrected to read "The Drawing Area block provides a control to display an area in the command's dialog box that can be used to show JPG,BMP,TIFF and PNG pictures." Also the file selection dialog will now include options for all available file types. |
1992259 |
Siemens PLM believes that the problem you reported where "no intersection detected during parallel dimensioning" will be resolved by code changes made to the release of our product NX 10. |
1992290 |
Siemens PLM believes that the problem you reported where "NXOpen/Journal: DraftingView.ViewBreaks-Collection throws exception" will be resolved by code changes made to the release of our product version NX 10. |
1992368 |
Siemens PLM believes that the problem you reported where an excessive time is needed to load a master assembly of a drafting part will be resolved by code changes made to the upcoming release of our software NX 10. |
1992421 |
Siemens PLM believes that the problem you reported where Electrical Routing:LostConstraintDuringRCP-Movement will be resolved by code changes made to the release of our product NX 10. The problem where a constraint could be lost when moving an RCP is fixed in NX 9.0.2 MP2, NX 9.0.3, and NX 10. |
1992451 |
Siemens PLM believes that the problem you reported where NXOpen : Can't get Components of a User Defined Order will be resolved by code changes made to the upcoming release of our software NX 10. |
1992516 |
Siemens PLM believes that the problem you reported where Constraints are not created for Routing Parts with engagement values defined on port will be resolved by code changes made to the release of our product NX 10. |
1992532 |
Siemens PLM believes that the problem you reported where mirror certification cannot create the correct mirror boundary will be resolved by code changes made to the upcoming release of our software NX 10. This version is planned to be available for download from 23-Dec-2014. |
1992587 |
Siemens PLM believes that the problem you reported where positioning and editing of additional text and symbols in GD&T-Symbols will be resolved by code changes made to the release of our product. The problem where the leader does not stay attached to the FCF when above appended text is added is fixed by a project in NX 10. Note: for parts created in previous releases a drawing update will cause the leader attachment to move to the correct location. |
1992612 |
Siemens PLM believes that the problem you reported where Synchronous modeling Feature causes PTS freeze will be resolved by code changes made to the upcoming release of our software NX 10. |
1992619 |
Siemens PLM believes that the problem you reported where "Error in Refset content regarding Sketches" will be resolved by code changes made to the upcoming release of our software NX 10. |
1992620 |
Siemens PLM believes that the problem you reported where "Reg_NX 7.5.4. Drawing views updated on an inactive drawing do not regenerate" will be resolved by code changes made to the release of our product NX 10. Workarounds in previous releases: The views have updated properly but the display is incorrect. 1) "Menu->View->Operation->Regenerate Work" will resolve the issue. OR 2) Save and re-open drawing. |
1992714 |
Vehicle Design Automation - Mirror Certification. |
1992816 |
Siemens PLM believes that the problem you reported where NX assembly cannot be loaded - Error: The same title cannot be used on two different will be resolved by code changes made to the upcoming release of our software NX 10. The problem mentioned in pr text is fixed and the fix would be available in NX 10 Also submitted fix to NX 8.5.3 MP3 HF, NX 8.5.3 MP and NX 9.0.3 MP. |
1992907 |
Siemens PLM believes that the problem you reported where wrong translation "during the load of" will be resolved by code changes made to the release of our product NX version NX 10. |
1992920 |
Siemens PLM believes that the performance issue you reported when using Smart Lightweight is due to: 1) Bad geometry imported during part translation 2) The Facet Brep generation code in NX did not handled the non-manifold case gracefully To fix 1) please regenerate the Jt data in NX refile_part -regen_lw -y -f -d <where the parts are located> and then create the Smart Smart Lightweight Views again. Point 2) will be resolved by code changes made to the upcoming release of our software NX 10. |
1993087 |
Siemens PLM believes that the problem you reported where Performance issue with zoom in/out due to model feature Subtract will be resolved by code changes made to the upcoming release of our software NX 10. |
1993096 |
Siemens PLM believes that the problem you reported where "Internal error: memory access violation occurred when one selects both unmapped components and maps existing afem" will be resolved by code changes made to the upcoming release of our software NX 10. |
1993118 |
Siemens PLM believes that the problem you reported where Vehicle Design Automation: Windshield Vision Zones will be resolved by code changes made to the upcoming release of our software NX 10. |
1993119 |
Siemens PLM believes that the problem you reported where Vehicle Design Automation: Windshield Vision Zones will be resolved by code changes made to the upcoming release of our software NX 10. The problem where the illustration graphics was not correct as per the European Standard is fixed in NX 10. |
1993121 |
Siemens PLM believes that the problem you reported where the Option "File -> Import -> STL -> Facet Body Type" is not saved in Dialog Memory will be resolved by code changes made to the upcoming release of our software NX 10. |
1993212 |
The alert information depends on the Parasolid tracking information and the resultant ps_tag. As for the intersection case where the tool body is completely inside the target body, none of the PS tag on the target body survives on the resultant body, all the PS tags on the resultant body are inherited from the tool, as well as the face label. It would be necessary for some customers to be informed of the condition. Maybe some customers do not think it is necessary. As for the wrong message order, it has been corrected in NX 10. |
1993254 |
Siemens PLM believes that the problem you reported where "Transient components must not be automatically stored on file system" will be resolved by code changes made to the release of our product NX version NX 10 phase 21, and is a candidate for inclusion in a NX 9.0.3 MP. |
1993271 |
Siemens PLM believes that the problem you reported where a Block UI Styler 'Drawing Area' block won't find a JPG image in an 'application' subfolder will be resolved by code changes made to the release of our product NX 10. |
1993310 |
Siemens PLM believes that the problem you reported where FASC Contour Area operation does not cut all of the area will be resolved by code changes made to the release of our product NX 10 and has been submitted to a for a future MP release of NX 9.0.3. The problem is caused by the cut area containing undercuts w.r.t. to the tool axis and these by default are not machined. To enable the machining of these it will be necessary to set the ENV variable UGII_CAM_MACHINE_IN_REGION_UNDERCUT= 1. |
1993381 |
Siemens PLM believes that the problem you reported where CAM: Own Collision Pairs inside NX 9.0.2 are not Saved after "OK" will be resolved by code changes made to the upcoming release of our software NX 9.0.3 MP1, NX 10.14. |
1993415 |
Siemens PLM believes that the problem you reported where Spline update Issues 2 will be resolved by code changes made to the upcoming release of our software NX 10. The problem where coincident constraint is not inferred in edit of a sketch spline has been fixed in NX 10. Please note that continuity constraints are not captured for spline through-points during edit. Only G0 will be captured as a coincident constraint on edit. |
1993420 |
Siemens PLM believes that the problem you reported where Section Surface - modeler error will be resolved by code changes made to the release of our product NX 10. |
1993481 |
Siemens PLM believes that the problem you reported where Mirror Feature does not work on UDF will be resolved by code changes made to the release of our software NX 10. |
1993487 |
Siemens PLM believes that the problem you reported where Cavity Mill creates Collision between IPW and Tool by using Lowest Z-Level will be resolved by code changes made to the release of our product NX .90.3 MP1. |
1993510 |
Siemens PLM believes that the problem you reported where Project curve in modeling - reverse projection will be resolved by code changes made to the upcoming release of our software NX 10. The problem where project curve in modeling - reverse projection is fixed in release NX 10 IP18. The fix is version protected in NX 10. Hence, to test the fix please create a new project curve feature in NX 10. |
1993537 |
Siemens PLM believes that the problem you reported where the blank XLS register form in ELECTRODE_DESIGN_DIR cannot be found without the XS4 file will be resolved by code changes made to the upcoming release of our software NX 10. |
1993566 |
Siemens PLM believes that the problem you reported where Create constraint with drag & drop doesn't work correct "within active sketch only", will be resolved by code changes made to the upcoming release of our software NX 10. |
1993588 |
Siemens PLM believes that the problem you reported where CreateDrawingEditViewSettingsBuilder only works with single member view array will be resolved by code changes made to the upcoming release of our software NX 10 by extending the NXOpen documentation. It will state the need for the ProcessForMutipleObjectsSettings API for multiple object settings. The correct steps are: - Create individual builder for all selected objects. For first builder (i.e. primary builder) pass all selected objects. For next builders (i.e. secondary builder), pass single object starting from 2nd selected object. - Call ProcessForMutipleObjectsSettings API on SettingsManager by passing all these above created edit settings builder. - Call InheritSettingsFromCustomerDefault on primary builder. - Call commit on each of these builder. - Call destroy on each of these builder. However, there is nothing wrong with the provided workaround by creating a single member view array instead for each Drafting View member: ------------- DraftingView[] allDraftingViews = workPart.DraftingViews.ToArray(); for (int ii=0; ii<allDraftingViews.Length; ii++) { View[] views1 = new View[1]; views1[0] = allDraftingViews[ii]; NXOpen.Drawings.EditViewSettingsBuilder editViewSettingsBuilder1; editViewSettingsBuilder1 = workPart.SettingsManager.CreateDrawingEditViewSettingsBuilder(views1); editViewSettingsBuilder1.InheritSettingsFromCustomerDefault(); NXObject nXObject1 = editViewSettingsBuilder1.Commit(); editViewSettingsBuilder1.Destroy(); lw.WriteLine("Updating view " + allDraftingViews[ii].ToString() ); allDraftingViews[ii].Update(); } ------------- |
1993746 |
Incorrect display of treaded hole on the multi-segment Section. |
1994012 |
Siemens PLM believes that the problem you reported where Pattern feature very slow to generate will be resolved by code changes made to the upcoming release of our software NX 10. |
1994058 |
Siemens PLM believes that the problem you reported with "Wrong Pendulum Profile for ECE-R42 Rotated-Front" will be resolved by code changes made to the upcoming release of our software NX 10. |
1994063 |
Siemens PLM believes that the problem you reported where "Misbehavior deleting a linked-sketch object" will be resolved by code changes made to the upcoming release of our software NX 10. |
1994135 |
Russian symbols displays as rubbish in the attribute "Component Name". |
1994168 |
Siemens PLM believes that the problem you reported "Vehicle Design Automation: Cylinder positions of Close Range Visibility wrong" will be resolved by code changes made to the upcoming release of our software NX 10. |
1994244 |
Siemens PLM believes that the problem you reported where Incorrect translation of Product of Inertia (Centroidal) on (GERMAN UI) will be resolved by code changes made to the release of our product NX 10. |
1994304 |
Siemens PLM believes that the problem you reported where Misbehavior at Extracted Bodies in the Target Part will be resolved by code changes made to the release of our product NX 10. The problem where after relinker, the 3rd extract ("ExtractGEO") on the target part wrongly became "Linked Body" (interpart). This issue has been fixed in NX 9.0.2 D3 onwards. The other issues is with the PN OOD column reporting: the extracts should all be OOD is fixed in NX 10 with project work. |
1994399 |
Siemens PLM believes that the problem you reported where the Business Item Type is not visible in NX when unique Teamcenter property is applied will be resolved by code changes made to the upcoming release of our software NX 10. |
1994482 |
Siemens PLM believes that the problem you reported where NX 9 ugtopv - Geometry missing in PMI Model Views created with mergeSolids false will be resolved by code changes made to the release of our product. The problem where Geometry is missing in PMI Model Views created with mergeSolids false is fixed in release NX 10. |
1994543 |
Siemens PLM believes that the problem you reported where Holetable with incorrect diameters will be resolved by code changes made to the upcoming release of our software NX 10. |
1994704 |
Siemens PLM believes that the problem you reported where "Exact View behaves different to Exact (Pre NX 8.5) view concerning view dependent" will be resolved by code changes made to the release of our product NX 10. The problem where view dependent edits vanish when "Hidden Line" option is set to Invisible is fixed in NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them. A new procedure entitled "Display only view dependently edited hidden lines" is added to the Drafting Help that documents the process. |
1994755 |
Siemens PLM believes that the problem you reported where Creation of Upper Roof crashes Head Impact feature will be resolved by code changes made to the upcoming release of our software NX 10. |
1994785 |
The problem where the size of the angular dimension was incorrect in a smart lightweight view is fixed in NX 10. For exact views the dimension should be fixed immediately on part open. For smart lightweight views a view update is required. |
1994815 |
Siemens PLM believes that the problem you reported where using the NXOpen method "NXOpen.Assemblies -> ComponentAssembly -> AddComponent()" in a renamed Sub Assembly puts the leaf component into a blanked state will be resolved by code changes made to the release of our product NX 10. |
1994883 |
Siemens PLM believes that the problem you reported where you are unable to modify assigned Item ID during Save as > new item will be resolved by code changes made to the upcoming release of our software NX 10. |
1994897 |
Siemens PLM believes that the problem you reported where Update of Detail View will delete Circular Pattern Features will be resolved by code changes made to the upcoming release of our software NX 10. |
1994937 |
Siemens PLM believes that the problem you reported where Journal Automation fails on WEDM UDEs with "can not output code to find <JABL>: <UGS::UICOMPJA_list>" will be resolved by code changes made to the release of our product NX 10. |
1995020 |
Siemens PLM believes that the problem you reported where a non-associative linked boolean tool body moves to layer 271 randomly will be resolved by code changes made to the release of our product NX 10. The tool body created by the slave linked body feature is now always hidden and moved to hidden layer 271. |
1995092 |
Siemens PLM believes that the problem you reported where modeler error occurs with stepped section line after adding segment and then specifying the hinge vector is fixed as part of Section View Enhancement project and will be fixed in released version of NX 10. For NX 8.5 and NX 9 versions there is a workaround available for this issue which is to define Hinge Line prior specifying point for placing section line. |
1995124 |
Siemens PLM believes that the problem you reported where "Internal error while using edit section in an assembly with JT component" will be resolved by code changes made to the release of our software NX 10. The other problem reported in Pr about not being able open Jt files is being tracked in a separate PR (7183469) |
1995316 |
Siemens PLM believes that the problem you reported where Not editable Section Surface will be resolved by code changes made to the release of our product NX 10. |
1995318 |
Siemens PLM believes that the problem you reported where "Part Cleanup run create timestamp problem" will be resolved by code changes made to the release of our product NX 10 phase 20. |
1995319 |
Siemens PLM believes that the problem you reported where the Up to Date status of the Feature Groups are wrong displayed will be resolved by code changes made to the release of our product NX 10. This version is planned to be ready for customer download from 23.12.2014. |
1995342 |
Siemens PLM believes that the problem you reported where the 'import immediately' option on the various forms associated with the 'results manipulation' functionality (envelope, combination, etc.) has been removed in NX 9.0.x will be resolved by code changes made to the upcoming release of our software NX 10.*** Below is an explanation as to why the 'import immediately' option was removed in NX 9.0.x. However, following customer feedback this option has been re-introduced in NX 10.In NX 9 the 'output' block of all four 'results manipulation' dialogs was modified. There were a few important usability changes made: 1 - the 'include model' option was removed and a '.unv' file is always imported with the fea model 2 - the 'import immediately' option was also removed: > for 'imported' results this option enabled the immediate loading of the newly created result file > for 'companion' results this option was used to unload and load the solution result Though it was not transparent to user, 'import immediately' meant unloading and then re-loading of the results. We wanted to avoid this because from NX 9 onwards we are creating 'graph' items that persist as long as the results are loaded. There are other entities too (like 'path' and 'seed'). There are 'postviews', 'annotation', etc. as well. We were not giving the user any warning and simply unloading the results (thus deleting all these transient objects). This was felt to be a usability issue, and hence the 'import immediately' option for 'companion' results was removed. |
1995473 |
Siemens PLM believes that the problem you reported where: Ray traced studio editor sets wrong image size for units=mm will be resolved by code changes made to the release of our software NX 10. |
1995875 |
Siemens PLM believes that the problem you reported where MOM_abort issued from a sub-post run crashes NX will be resolved by code changes made to the release of our product NX 10. |
1996192 |
Siemens PLM believes that the problem you reported where Fatal error while extrude an isocline will be resolved by code changes made to the release of our product NX 10. |
1996194 |
Siemens PLM believes that the problem you reported with a un-configured Transient Components become visible under certain circumstances will be resolved by code changes made to the release of our product. It has been resolved in NX 10 and is a candidate for an NX 9.0.3 MP. |
1996244 |
Siemens PLM believes that the problem you reported where "PS27.1.116:Face Blend on mirrored geomtrie does not work" will be resolved by code changes made to the release of our product NX 10ip22. |
1996317 |
Siemens PLM believes that the problem you reported where Load Options won't Restore "Latest Working" from Default will be resolved by code changes made to the release of our product NX 10. |
1996353 |
Siemens PLM believes that the problem you reported where "Missing Lines and Error Message after CGM-Import in NX 8.5 - Regression to NX 7.5" will be resolved by code changes made to the release of our product NX 10. In addition fixes were submitted for consideration to include in a future NX 8.5.3 and NX 9.0.3 MP. |
1996406 |
Siemens PLM believes that the problem you reported where it is not possible to see the custom item types with required properties in NX dialogs is fixed in the release NX 10.Starting from NX 10. NX now supports Items with required properties defined in Teamcenter without any special setting required. |
1996409 |
Siemens PLM believes that the problem you reported where the GRIP statement FILE/PART fails in batch mode with 1545013 "Unable to file part" when 'Save JT Data' is turned on will be resolved by code changes made to the release of our product NX 10. |
1996449 |
Siemens PLM believes that the problem where "strange text by drafting standard... - standard to load" will be fixed in NX 10. |
1996482 |
Siemens PLM believes that the problem you reported where "Ansichtenabhängiges Bearbeiten funktioniert nicht mehr mit den neuen Ansichten" will be resolved by code changes made to the release of our product NX 10.The problem where view dependent edits vanish when "Hidden Line" option is set to Invisible is fixed in NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them. A new procedure entitled "Display only view dependently edited hidden lines" is added to the Drafting Help that documents the process. |
1996491 |
Siemens PLM believes that the problem you reported where "an operation was attempted on an invalid or unsuitable OM object" error will be resolved by code changes made to the release of our product NX 10. |
1996787 |
Siemens PLM believes that the problem you reported where Sketcher - Make Corner deletes tangent Constraint will be resolved by code changes made to the release of our product NX 10. |
1997024 |
Siemens PLM believes that the problem you reported where "NX Laminate Dynamics executable crashes when computing Tsai-wu failure metrics" will be resolved by code changes made to the release of our product NX 10 |
1997048 |
Siemens PLM believes that the problem you reported where Results when using Single Segment tube are different from those in NX 7.5 will be resolved by code changes made to the release of our product NX 10.The Tube feature has been enhanced to produce better output for tangent curves for "single segment" output option. The swept surface of the Tube will terminate at the end of each discrete curve in the tangent-continuous path. Tube features created in NX 10 and later will have the new behavior; NX 9 and older features will continue to maintain their output geometry. However, these fixes are version-controlled for NX 10 and later features. They cannot be backported to NX 8.5 MP or NX 9 MP due to risks of regression and forward compatibility. |
1997171 |
Save results in error "..errors importing assembly arrangement PLMXML documents. |
1997480 |
Mirror Feature fails to work correctly. |
1997500 |
Siemens PLM believes that the problem you reported where 'Insert row in hole table results in internal error' will be resolved by code changes made to the release of our product NX 10. Insert Rows/Column option is not supported on the hole table. The "Menu - Edit- Table - Insert" option for the hole table will be disabled. |
1997750 |
Siemens PLM believes that the problem you reported where the Verify dialog adds an extra move before the Go Home move causing it to traverse through the part is fixed in NX 9.0.3 MP2 and NX 10. |
1998096 |
Siemens PLM believes that the problem you reported where "Alignment Through Curves" will be resolved by code changes made to the release of our product NX 10 phase 22 with cp NX321363. |
1998107 |
The problem where view dependent edits vanish when "Hidden Line" option is set to Invisible is fixed in NX 10. You can make the view dependent edits, and then set the "Show Referenced Edges Only" option to hide all hidden edges except those edges that have view dependent edits applied to them. |
1998137 |
Siemens PLM believes that the problem you reported where " Exception thrown when Breaking Links " will be resolved by code changes made to the release of our product NX version 10. |
1998190 |
The problem where NX Drafting Preferences "Apply to entire dimension" revert to enabled upon Apply has been investigated and the following has been found. If "Apply to entire dimension" toggle is ON then any changes in appended text color, font, width, height, gap factor, aspect ratio and line factor applies to entire dimension INSTANTLY, (without hitting Apply button). Whereas while launching dialog, if all appended, dimension, tolerance text settings are same then Apply to entire dimension toggle automatically gets turned on, else turned off. An example, user first make changes in text height from 3.5 to 8. As "Apply to entire dimension" toggle is ON, so this modified appended dimension text height applied to other dimension text i.e. Dimension Text, Tolerance Text height. Now if we turn off "Apply to entire dimension" toggle and say Apply. Preference dialog gets created with new modified settings. Here all dimension text settings are same for appended, dimension, tolerance text so "Apply to entire dimension" toggle gets turned on automatically. So it"s working as designed. If user wants to make only Appended Text height as 8, then he first need to turn off Apply to entire dimension toggle and then change height to 8, Apply on Preference dialog. Now you can check "Apply to entire dimension" toggle will be off and Appended text height is changed 8 whereas dimension, tolerance text height is still 3.5. In NX 10 documentation the following clarification have been made about "Apply to entire dimension": ------------------- "When set, any changes made to the color, font, width, height, gap factors and aspect ratio settings are immediately applied to all of the dimension text. You do not have to click the Apply button. If you only want to apply changes to the appended text for the dimension, you must clear this option first and then make your changes." ------------------- |
1998227 |
Siemens PLM believes that the problem you reported where Display of NX 9 hole table is reset to standard color if updating will be resolved by code changes made to the release of our product NX NX 10. |
1998260 |
NX Assembly Arrangement Bug - PR2242198 |
1998584 |
Siemens PLM believes that the problem you reported where Profile list created from Ship Structure Manufacturing gives wrong output will be resolved by code changes made to the release of our product NX version 10. Character used as thousands separator defined in Windows for Norway is not NX standard character set (UTF8). Changed code to remove thousands separator from the numeric output to the Profile List. Fixed in NX 9.0.3 MP 2 and NX 10. |
1998745 |
Siemens PLM believes that the problem you reported where measurement results in Animation are not up to date will be resolved by code changes made to the release of our product NX 10 and NX 9.0.3 patch. |
1998779 |
Siemens PLM believes that the problem you reported where "Missing Flat Pattern geometry on DXF export" will be resolved by code changes made to the release of our product NX 10. |
1998791 |
Siemens PLM believes that the problem you reported where Displayed "optimized Tool Axis" when License is missed but Documentation says it will not will be resolved by code changes made to the release of our product NX 10 |
1998947 |
Siemens PLM believes that the problem you reported where drafting thread curves are missing a transform and therefore incorrectly displayed in new exact, revolved section views is fixed in NX 10. This version is planned to be available for customer download from 23-Dec-2014. |
1999035 |
The problem where Clone "edit existing assembly" internal error is fixed in release NX 10 and this is also fixed in NX 9.0.3MP. |
1999293 |
Siemens PLM believes that the problem you reported with NX SheetMetal - Creating a Flange not possible because a edge can not be selected will be resolved by code changes made to the release of our product NX 10. |
1999304 |
Siemens PLM believes that the problem you reported where "Exception is Thrown when performing SaveAs" will be resolved by code changes made to the release of our product NX 10. |
1999569 |
Siemens PLM believes that the problem you reported where with multiple strip with Strip Layout in Progressive Die Wizard will be resolved by code changes made to the release of our product NX 10. |
1999833 |
Siemens PLM believes that the problem you reported where "No install documentation for EasyFill" will be resolved by code changes made to the release of our product NX version 10.0 It can be found from Home -> CAD -> NX Analysis -> Molded Part Validation |
2061795 |
Siemens PLM believes that the problem you reported where editing the Corner Radius of a Bend did not refer back to the imported Bend Table that was originally used to define the radius, will be resolved by code changes made to the upcoming release of our software NX 10. |
2113647 |
Siemens PLM believes that the problem you reported where length and width problem in Relief Origin of 'Corner Point'/Rectangular Cutout is As Designed. Since the Rectangle shape does not have anything like a Centre point as defined for a Circle, the BendCenter/CornerPoint is mapped to the starting corner of the Rect. Cutout. The NX 10 documentation will be updated. |
2114330 |
Siemens PLM believes that the problem you reported where manually inputting a long directory path in the Compare Runs dialog cannot be done, will be resolved by code changes made to the upcoming release of our software NX 10. |
2114333 |
Siemens PLM believes that the problem you reported where a Corner Preference was not reflected in Assign Corner, will be resolved by code changes made to the upcoming release of our software NX 10. |
2114336 |
Siemens PLM believes that the problem you reported where 'Flat Pattern Treatments' Preferences being over-written by 'NX Sheet Metal' Preferences will be resolved by code changes made to the upcoming release of our software NX 10. |
2124248 |
Siemens PLM believes that the problem you reported where the output results for geometry moment of Section Inertia are not on the XY plane will be resolved by code changes made to the upcoming release of our software NX 10. |
2130834 |
Display performance is low when drag dimension in flatpattern view. |
2133338 |
Siemens PLM believes that the problem you reported where the Drafting, "Color Filter" was not reset via the Reset Filters icon, will be resolved by code changes made to the upcoming release of our software NX 10. |
2135322 |
Siemens PLM believes that the problem you reported where Feature Playback fails in NX 7.0.1.6 at Offset Face(116) raising the error "Cannot apply offset" will be resolved by code changes made to the upcoming release of our software NX 10. |
2135805 |
Siemens PLM believes that the problem you reported where STEP File (214) exported from Vis View-2007 could not open in NX 6 will be resolved by code changes made to the upcoming release of our software NX 10. |
2138530 |
Siemens PLM believes that the problem you reported where the Drafting View from the sub-assembly part file copies the Arrangement to the Drafting file has been reviewed by development. Due to the low priority of the problem and the length of time the current behavior has been in the system we do not intend to fix this PR. If the problem is still impacting your day to day operation as you use the NX product, please contact GTAC to have the PR reopened. |
2140433 |
Siemens PLM believes that the problem you reported where it takes too much time for a step file conversion in NX6 will be resolved by code changes made to the upcoming release of our software NX 10. |
2141116 |
Siemens PLM believes that the problem you reported where the marker of the 'Minimum Radius' is displayed on the convex (outside) of a solid face will be resolved by code changes made to the upcoming release of our software NX 10. |
2142096 |
Siemens PLM believes that the problem you reported where importing a DXF file ends before completion will be resolved by code changes made to the upcoming release of our software NX 10. |
2144276 |
Siemens PLM believes that the problem you reported where the Selection Color Filter was not reset by the Reset Filters operation, will be resolved by code changes made to the upcoming release of our software NX 10. |
2144929 |
Siemens PLM believes that the problem you reported where SB Unbend gave different results for a subdivided face, will be resolved by code changes made to the upcoming release of our software NX 10.To verify the fix create a new Unbend feature. |
2146351 |
Siemens PLM believes that the problem you reported where Autoroute was broken after a point was created on knot point, using point on curve will be resolved by code changes made to the upcoming release of our software NX 10. |
2147498 |
Siemens PLM believes that the problem you reported where "Reverse Direction" after "Sectional Sketch" edit raised errors, will be resolved by code changes made to the upcoming release of our software NX 10.Here, sketch of Flange has been edited and thus the flange becomes a Custom Flange after which user tried to reverse the direction of the same but, due to some NX limitations we currently don't support the reversing of custom flange and we ideally should have not shown the reverse handle direction for the same which happen to be available due to some of code flaw which was presuming the flange to be normal flange. We made the necessary changes so that it can be considered as the custom flange now after NX 10 and no reverse handle direction is available. A simple work-around would be to select the opposite edge and adjust sketch constraints if necessary. Made the necessary changes to NX 10 node. |
2147974 |
Siemens PLM believes that the problem you reported where UF_ROUTE_set_part_in_stock() creates an additional feature will be resolved by code changes made to the upcoming release of our software NX 10. |
2148864 |
Siemens PLM believes that the problem you reported where NX6.0 Shell features fail to update in NX7.5, will be resolved by code changes made to the upcoming release of our software NX 10. |
2150833 |
Siemens PLM believes that the problem you reported where only one or the other virtual intersection curve appears when both Intersection Curves should be created will be resolved by code changes made to the upcoming release of our software NX 10. |
2151119 |
Siemens PLM believes that the problem you reported where a three-quarter height fraction does not correctly convert when exporting a DXF will be resolved by code changes made to the upcoming release of our software NX 10. |
2152029 |
Siemens PLM believes that the problem you reported where the Virtual Intersection only shows on one side at a time will be resolved by code changes made to the upcoming release of our software NX 10.The Virtual Intersection should only display on the left side. The right half should not display because it lies outside the blend face. The display of this Virtual Intersection has been fixed to always display only the left side. |
2152499 |
Siemens PLM believes that the problem you reported where the English description appears in the Routing settings dialog, even though the Japanese language is set will be resolved by code changes made to the upcoming release of our software NX 10. |
2153094 |
Siemens PLM believes that the problem you reported where the Virtual Intersection only shows on one side at a time will be resolved by code changes made to the upcoming release of our software NX 10.The Virtual Intersection should only display on the left side. The right half should not display because it lies outside the blend face. The display of this Virtual Intersection has been fixed to always display only the left side. |
2153656 |
Siemens PLM believes that the problem you reported where a divided sweep color did not change will be resolved by code changes made to the upcoming release of our software NX 10. |
2153910 |
Siemens PLM believes that the problem you reported where a fix constraint doesn't work in Move Part will be resolved by code changes made to the upcoming release of our software NX 10. |
2154824 |
Siemens PLM believes that the problem you reported where a dialog is not stretched correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2154830 |
Siemens PLM believes that the problem you reported where rotating stock causes edge chamfer update to fail will be resolved by code changes made to the upcoming release of our software NX 10. |
2155068 |
Siemens PLM believes that the problem you reported where Intersection point of stock is incorrect will be resolved by code changes made to the upcoming release of our software NX 10. |
2156389 |
Siemens PLM believes that the problem you reported where "Error occurs by executing Feature Playback" will be resolved by code changes made to the upcoming release of our software NX 10. |
2156417 |
Siemens PLM believes that the problem you reported where the default color of a modified face on a space reservation returns after editing its path will be resolved by code changes made to the upcoming release of our software NX 10. |
2156735 |
Siemens PLM believes that the problem you reported where "Delete Face removes body face after feature update" will be resolved by code changes made to the upcoming release of our software NX 10. |
2157433 |
Siemens PLM believes that the problem you reported where an unselected Routing Control Point moves, even though it was not selected to be moved, will be resolved by code changes made to the upcoming release of our software NX 10. |
2158071 |
Siemens PLM believes that the problem you reported where the documentation for CreateExpressionCollectorSet method was inadequate the will be resolved by code changes made to the release of our product NX 10. |
2158288 |
Siemens PLM believes that the problem you reported where Annotation with leader moves when 2D Exchange is run will be resolved by code changes made to the upcoming release of our software NX 10. |
2159335 |
Siemens PLM believes that the problem you reported where attaching an RCP to a port creates another point will be resolved by code changes made to the upcoming release of our software NX 10. |
2159621 |
Siemens PLM believes that the problem you reported where executing "Convert To Stock As Component" on UDO Feature that includes UDF Feature, its Layer is changed to 271 will be resolved by code changes made to the upcoming release of our software NX 10. |
2163240 |
Siemens PLM believes that the problem you reported where converting a drawing part file into the DXF format using 2D Exchange stops when special characters are found will be resolved by code changes made to the upcoming release of our software NX 10. |
2163338 |
Siemens PLM believes that the problem you reported where selecting the Stock or Place Part icon, NX will not display parts in Member view will be resolved by code changes made to the upcoming release of our software NX 10. |
2163552 |
Siemens PLM believes that the problem you reported where an icon popup "restart", "previous", "next" in Place Part dialog does not display will be resolved by code changes made to the upcoming release of our software NX 10. |
2163771 |
Siemens PLM believes that the problem you reported where the Back button closes the Confirm Position dialog of the Move Part function, instead of opening the previous dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
2164830 |
Siemens PLM believes that the problem you reported where an error occurs when "2D Exchange" is executed will be resolved by code changes made to the upcoming release of our software NX 10. |
2166929 |
Siemens PLM believes that the problem you reported where Harness form collapses adding Space Reservation, will be resolved by code changes made to the upcoming release of our software NX 10. |
2167497 |
Siemens PLM believes that the problem you reported where the preview of a Sheet Metal Bend was not the same in NX7.5 as it was in NX6.0 when using the type Sheet Metal from Solid, will be resolved by code changes made to the upcoming release of our software NX 10. |
2167792 |
Siemens PLM believes that the problem you reported where it was not possible to select a Port within the Lock Port dialog, will be resolved by code changes made to the upcoming release of our software NX 10. |
2168903 |
Siemens PLM believes that the problem you reported where a Solid Works assembly fails to open in NX, will be resolved by code changes made to the upcoming release of our software NX 10. |
2169226 |
Siemens PLM believes that the problem you reported where virtual intersection curves are incorrectly trimmed in the view will be resolved by code changes made to the upcoming release of our software NX 10. |
2169753 |
Siemens PLM believes that the problem you reported where when using SetSelectionFilter with a Block Styler Select Objects block to select Views(UFConstants.UF_view_type) any subtypes set in the Selection.MaskTriple array were ignored, will be resolved by code changes made to the upcoming release of our software NX 10. |
2169856 |
Siemens PLM believes that the problem you reported where an override was created when a connector was moved by Move Part will be resolved by code changes made to the upcoming release of our software NX 10. |
2170019 |
Siemens PLM believes that the problem you reported where the Information Window opens behind a dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
2170084 |
Siemens PLM believes that the problem you reported where Pin 1 ID Color is changed to other faces if segment is deleted will be resolved by code changes made to the upcoming release of our software NX 10. |
2170115 |
Siemens PLM believes that the problem you reported where the Formboard Layout rotated after setting the Rounding Method to "Up to Nearest" and updating the layout, will be resolved by code changes made to the upcoming release of our software NX 10. |
2170134 |
Siemens PLM believes that the problem you reported where the same Routing part could not be placed from Reuse Library, will be resolved by code changes made to the upcoming release of our software NX 10. |
2170283 |
Siemens PLM believes that the problem you reported where a deformable part fails to change when adding extra wires will be resolved by code changes made to the upcoming release of our software NX 10. |
2170658 |
Siemens PLM believes that the problem you reported where JT files with PMI Dimensions created on a line is changed to "assorted part" when reopened in NX, will be resolved by changes made to the release of our software NX 10. |
2170689 |
Siemens PLM believes that the problem you reported where a JT file containing PMI Locator Symbol being opened in NX changed to "assorted parts", will be resolved by changes made to the release of our software NX 10. |
2171159 |
Siemens PLM believes that the problem you reported where Macro doesn't record overridden Color Palette properly will be resolved by code changes made to the upcoming release of our software NX 10. |
2171166 |
Siemens PLM believes that the problem you reported where Export clip data to PLM XML file fails when attached to RCP will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10. |
2171381 |
Siemens PLM believes that the problem you reported where Exporting and Importing an Assembly causes problems with STEP 214 will be resolved by code changes made to the upcoming release of our software NX 10. |
2171495 |
Siemens PLM believes that the problem you reported where the Routing Control Point is moved after placing a cut elbow will be resolved by code changes made to the upcoming release of our software NX 10. |
2171705 |
Siemens PLM believes that the problem you reported where Virtual Intersections are not displayed will be resolved by code changes made to the upcoming release of our software NX 10. |
2172096 |
Siemens PLM believes that the problem you reported where characteristics specified using Search Children were not kept when placing a Routing part using the Reuse Library, will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10. |
2173062 |
Siemens PLM believes that the problem you reported where "Replace Face is failed to update" will be resolved by code changes made to the upcoming release of our software NX 10. |
2173158 |
Siemens PLM believes that the problem you reported where the Open C function UF_ROUTE_ask_port_back_extension() returns an incorrect value in NX 7.5 will be resolved by code changes made to the upcoming release of our software NX 10. |
2173209 |
Siemens PLM believes that the problem you reported where "Replace Face failed to update" will be resolved by code changes made to the upcoming release of our software NX 10. |
2173214 |
Siemens PLM believes that the problem you reported where "Delete face failed to update" will be resolved by code changes made to the upcoming release of our software NX 10. |
2173258 |
Siemens PLM believes that the problem you reported where Multi-body parasolid makes multi-component will be resolved by code changes made to the release of our product NX 10. NX 10 Documentation will now include a procedure topic with step on how to import a parasolid file that has multiple solid bodies to create an NX assembly. |
2173262 |
Siemens PLM believes that the problem you reported where "Delete Face is failed to update" will be resolved by code changes made to the upcoming release of our software NX 10. |
2173455 |
Siemens PLM believes that the problem you reported where the error "Routing: Wrong object type" occurred when exporting a Connection List plmxml file will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10. |
2174060 |
Siemens PLM believes that the problem you reported where Documentation is not clear when an open sketch is selected for Extrude will be resolved by changes made to the upcoming release of our NX 10 Documentation. |
2174208 |
Siemens PLM believes that the problem you reported where UDF instantiation produces different colors that the authoring part, will be resolved by code changes made to the upcoming release of our software NX 10. |
2174301 |
Siemens PLM believes that the problem you reported where an error was returned when creating a Routing Bill of Material will be resolved by code changes made to the upcoming release of our software NX 10. |
2174350 |
Siemens PLM believes that the problem you reported where From Comp./To Comp. columns were not populated on the Formboard Report, will be resolved by code changes made to the upcoming release of our software NX 10. |
2174805 |
Siemens PLM believes that the problem you reported where some Assembly commands are missing after going into Drafting will be resolved by code changes made to the upcoming release of our software NX 10. |
2175072 |
Siemens PLM believes that the problem you reported where the routing path extends unexpectedly when moving and deleting parts will be resolved by code changes made to the upcoming release of our software NX 10. |
2175189 |
Siemens PLM believes that the problem you reported where Routing Electrical path RCP cannot move in Z axis will be resolved by code changes made to the upcoming release of our software NX 10. |
2175567 |
Siemens PLM believes that the problem you reported where Overstock display is incorrect in shaded mode will be resolved by code changes made to the upcoming release of our software NX 10. |
2175786 |
Display anomaly. |
2176000 |
Siemens PLM believes that the problem you reported where Linear path between 2 points raises "Error in creation of sweep body" will be resolved by code changes made to the upcoming release of our software NX 10. |
2176285 |
Siemens PLM believes that the problem you reported where the GWIF does not display for some points of a Spline Path will be resolved by code changes made to the upcoming release of our software NX 10. |
2176557 |
Siemens PLM believes that the problem you reported where objects that only have silhouettes, such as Spheres, do not display their Silhouettes after turning the Silhouette Display off and back on, will be resolved by code changes made to the upcoming release of our software NX 8.5. |
2176704 |
Siemens PLM believes that the problem you reported where NX raised the message: "Unable to load the requested part! See Syslog!" having selected an existing part in the graphics display during a Place Part operation, will be resolved by code changes made to the upcoming release of our software NX9.0.1 and NX 10. |
2176747 |
Siemens PLM believes that the problem you reported where incorrect the error message for requesting assembly constraint conversion will be resolved by code changes made to the upcoming release of our software NX 10. |
2177305 |
Siemens PLM believes that the problem you reported where a user can not move object by "distance between points" will be resolved by code changes made to the upcoming release of our software NX 10. The NX documentation has been modified to help remove confusion on this function. The first paragraph in the Modeling Help for the Move Object, Distance Between Points option, was rewritten to be following: Distance between Points - A linear distance derived from an origin point and a reference measurement point. When you specify the origin and measurement points and the vector, the current distance between the points appears in the Distance box. You can then specify a new value in the Distance box to move the object along the vector to a new relative location. Callout numbers where also added to the image example to help identify the origin point, measurement point, and distance. |
2179936 |
Siemens PLM believes that the problem you reported where an External TCIN program cannot write to the console after UF_terminate() is called will be resolved by code changes made to the upcoming release of our software NX 10. The documentation has been updated to add a note in UF_terminate() and UF_UI_write_listing_window() explaining that once UF_terminate() has been called from an external program, you can no longer write to the console window. It must be re-initialized using system calls. |
2180925 |
Siemens PLM believes that the problem you reported where "Selection Steps" label on Define Run dialog will change unexpectedly, will be resolved by code changes made to the upcoming release of our software NX 10. |
2181066 |
Siemens PLM believes that the problem you reported where the Replace Component after Placing Part does not display the model in Shaded display will be resolved by code changes made to the upcoming release of our software NX 10. |
2181207 |
Siemens PLM believes that the problem you reported where it is not possible to specify "Segment Length" of "Subdivide Segments" command will be resolved by code changes made to the upcoming release of our software NX 10. |
2182685 |
Siemens PLM believes that the problem you reported on the environment variable "UGII_UDF_DOCUMENT_HOME", will be resolved by code changes made to the upcoming release of our software NX 10. |
2183190 |
Siemens PLM believes that the problem you reported where you received "Stock Not Found" using Auto Route to route wires in NX8, will be resolved by code changes made to the upcoming release of our software NX 10. |
2183393 |
Siemens PLM believes that the problem you reported where it is not possible to select a pattern array when assigning terminals will be resolved by code changes made to the upcoming release of our software NX 10. |
2183523 |
Siemens PLM believes that the problem you reported where extra segments were created when creating a Linear Path will be resolved by code changes made to the upcoming release of our software NX 10. |
2183735 |
Siemens PLM believes that the problem you reported where the error message of [Convert to Stock as Componets] is garbled in Japanese NX, will be resolved by code changes made to the upcoming release of our software NX 10. |
2184214 |
Siemens PLM believes that the problem you reported where preview of stock orientation is off 180 degrees will be resolved by code changes made to the upcoming release of our software NX 10. |
2184682 |
Siemens PLM believes that the problem you reported where PLMXML export of electrical harness data was inconsistent, will be resolved by code changes made to the upcoming release of our software NX 10. |
2185253 |
Siemens PLM believes that the problem you reported where user can't select the Information icon of Specification in Disciplines tab will be resolved by code changes made to the upcoming release of our software NX 10. |
2186362 |
Siemens PLM believes that the problem you reported where different result are observed by using "remove part" command will be resolved by code changes made to the upcoming release of our software NX 10. |
2186778 |
Siemens PLM believes that the problem you reported where PMI Coordinate Note doesn't follow view rotation will be resolved by code changes made to the upcoming release of our software NX 10. |
2186806 |
Siemens PLM believes that the problem you reported where it is not possible to create bend using Bend Radius Table which includes a 2-byte Table name} will be resolved by code changes made to the upcoming release of our software NX 10. |
2187452 |
Siemens PLM believes that the problem you reported where Move Part causes another part to change position, will be resolved by code changes made to the upcoming release of our software NX 10. |
2187610 |
Siemens PLM believes that the problem you reported where mesh updating cannot handle 80,000 or more mesh points will be resolved by code changes made to the upcoming release of our software NX 10. |
2187624 |
Siemens PLM believes that the problem you reported where Switch sheet preview does not update display in DXF/DWG Import Wizard will be resolved by code changes made to the upcoming release of our software NX 10. |
2187795 |
Siemens PLM believes that the problem you reported where modeler error occurred when updating hidden line display will be resolved by code changes made to the upcoming release of our software NX 10. |
2188472 |
Siemens PLM believes that the problem you reported where the Model Terminals command displays the paths to the terminals, but does not assign any stock, will be resolved by code changes made to the upcoming release of our software NX 10. |
2188536 |
Siemens PLM believes that the problem you reported where the PMI on the drawing cannot be correctly exported will be resolved by code changes made to the release of our product NX version 10. |
2189362 |
Siemens PLM believes that the problem you reported where brackets of reference dimension are missing after importing a DXF file, will be resolved by code changes made to the release of our product NX version 10. |
2189524 |
Siemens PLM believes that the problem you reported where a corner radius associated to an expression does not update when expression is changed, unless the corner is edited will be resolved by code changes made to the upcoming release of our software NX 10. |
2189972 |
Siemens PLM believes that the problem you reported where a Linear path RCP is not maintaining associativity} will be resolved by code changes made to the upcoming release of our software NX 10. |
2190605 |
Siemens PLM believes that the problem you reported where the Hem Flange did not recognize the depth of a slot, will be resolved by code changes made to the upcoming release of our software NX 10. |
2190880 |
Siemens PLM believes that the problem where reference mapping dialog pops up even when users set not to see this kind of dialog, will be resolved by code changes made to the upcoming release of our software NX 10. |
2191397 |
Siemens PLM believes that the problem you reported where after specifying Non-Proportional Zoom and using Move Object a curve jumped in the opposite direction when moving the Drag Handle, will be resolved by code changes made to the upcoming release of our software NX 10. |
2191429 |
Siemens PLM believes that the problem you reported where patch openings cannot be created correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2191498 |
Siemens PLM believes that the problem you reported where Expressions of thread and feature diameters are out of sync will be resolved by code changes made to the upcoming release of our software NX 10 |
2192097 |
Siemens PLM believes that the problem you reported where Stock rotation fails and corrupts unconnected stocks will be resolved by code changes made to the upcoming release of our software NX 10. |
2192102 |
Siemens PLM believes that the problem you reported where assigning a corner causes update errors will be resolved by code changes made to the upcoming release of our software NX 10. |
2192212 |
Siemens PLM believes that the problem you reported where "Make Work Part "popup command is not displayed for a opened component node in ANT will be resolved by code changes made to the upcoming release of our software NX 10. |
2192226 |
Siemens PLM believes that the problem you reported where you could not export JT when the double-byte character A was in the part, will be resolved by code changes made to the upcoming release of our software NX 10. |
2192293 |
Siemens PLM believes that the problem you reported where an internal error was raised exporting the Connection List as PLMXML, will be resolved by code changes made to the upcoming release of our software NX 9.0.1 & NX 10. |
2192330 |
Siemens PLM believes that the problem you reported where a highlighted edge stayed highlighted after cancelling an edge blend operation will be resolved by code changes made to the upcoming release of our software NX 10. |
2193844 |
Siemens PLM believes that the problem you reported where Assign corner failed depending on the creation order will be resolved by code changes made to the upcoming release of our software NX 10. |
2194858 |
Siemens PLM believes that the problem you reported where the radius will not be displayed if running the 'Minimum Radius' command will be resolved by code changes made to the upcoming release of our software NX 10. |
2194956 |
Siemens PLM believes that the problem you reported where the display of virtual intersection lines in drafting fails with Modeler error will be resolved by code changes made to the upcoming release of our software NX 10. |
2195069 |
Siemens PLM believes that the problem you reported where a copied face created using Synchronous Modeling added additional blended faces, will be resolved by code changes made to the release of our product NX 10. |
2195247 |
Siemens PLM believes that the problem you reported where the user saw incorrect PMI load behavior for the "PMI and Reference Geometry" customer default, will be resolved by code changes made to the upcoming release of our software NX 10.The PMI and Reference Geometry option to "Only Load with Exact Data" is only honored if the "Import Assembly Structure from JT Files" option is disabled. For the scenario shown in the supplied avi, the "Import Assembly Structure from JT Files" option is enabled. This is why the PMI are not loaded for the case shown. Now the Description of the PMI and Reference Geometry option in Customer Defaults has been changed to explicitly state that the "Only Load with Exact Data" is only honored if the "Import Assembly Structure from JT Files" checkbox is not marked. This will be submitted in NX 10. |
2195612 |
Siemens PLM believes that the problem you reported where the PMI is not loaded when "Only Load with Exact Data" option with JT data will be resolved by code changes made to the upcoming release of our software NX 10. |
2196134 |
Siemens PLM believes that the problem you reported where inconsistency in the display of "Modified" Mark will be resolved by code changes made to the upcoming release of our software NX 10. |
2196141 |
Siemens PLM believes that the problem you reported where the display of a view is reversed when the order of the selected point is different will be resolved by code changes made to the upcoming release of our software NX 10. |
2196245 |
Siemens PLM believes that the problem you reported where NXOpen::Facet::FacetedBodyCollection::Copy changes display properties status will be resolved by code changes made to the upcoming release of our software NX 10 |
2196753 |
Siemens PLM believes that the problem you reported where Create Linear Path raises the error: Work part has not been converted. Convert the part using: Assemblies -> Component Position -> Convert Mating Conditions will be resolved by code changes made to the upcoming release of our software NX 10 |
2196876 |
Siemens PLM believes that the problem you reported where changing the angle in the Formbaord layout was not updating as expected will be resolved by code changes made to the upcoming release of our software NX 10. |
2196994 |
Siemens PLM believes that the problem you reported where one body was being split into two bodies as the third body was created after creating a Linear Path will be resolved by code changes made to the upcoming release of our software NX 10. |
2197148 |
Siemens PLM believes that the problem you reported where editing of the Tabular Note using the Spreadsheet causes Excel to flash during the updating process will be resolved by code changes made to the upcoming release of our software NX 10. |
2197682 |
Siemens PLM believes that the problem you reported where after play macro the color block dialog is grayed out will be resolved by code changes made to the upcoming release of our software NX 10. |
2197722 |
CPJ :NXOpen::Facet::FacetedBodyCollection::Copy changes display properties status. |
2197824 |
Siemens PLM believes that the problem you reported where the Stock Fold could not be created will be resolved by code changes made to the upcoming release of our software NX 10. |
2197875 |
Siemens PLM believes that the problem you reported where Overstock is changed to stock by copying it to another part will be resolved by code changes made to the upcoming release of our software NX 10. |
2197974 |
Siemens PLM believes that the problem you reported where a screw seat is not positioned correctly to an elbow will be resolved by code changes made to the upcoming release of our software NX 10. |
2197988 |
Siemens PLM believes that the problem you reported where there was an area where a Screw Seat could not be arranged with a valid length, will be resolved by code changes made to the upcoming release of our software NX 10.Measurement Holders (screw seats) from the Reuse Library should be properly placed on Elbow parts that are correctly placed from the Reuse Library. |
2198746 |
Siemens PLM believes that the problem you reported where Stock is not oriented in the correct direction will be resolved by code changes made to the upcoming release of our software NX 10. |
2198869 |
Siemens PLM believes that the problem you reported where Space reservation takes much time and cannot be carried out will be resolved by code changes made to the upcoming release of our software NX 10 |
2199004 |
Siemens PLM believes that the problem you reported where the Sheet Metal Validation:Minimum Tool Clearance fails on a Dimple feature will be resolved by code changes made to the upcoming release of our software NX 10. |
2199073 |
Siemens PLM believes that the problem you reported where creating a Spline Path raises the error "Unable to create sweep body due to highly distorted segment" will be resolved by code changes made to the upcoming release of our software NX 10. |
2199884 |
Siemens PLM believes that the problem you reported where a Reference Set check mark is not displayed correctly in the Part Navigator after changing the ork part will be resolved by code changes made to the upcoming release of our software NX 10. |
2199916 |
Siemens PLM believes that the problem you reported where child features are not moved with stock} will be resolved by code changes made to the upcoming release of our software NX 10. |
2199921 |
Siemens PLM believes that the problem you reported where PMI Note position is changed when exported as a 2D exchange part will be resolved by code changes made to the upcoming release of our software NX 10. |
2200135 |
Siemens PLM believes that the problem you reported where it is not possible to control the size of text in Cut Sheet cells will be resolved by code changes made to the upcoming release of our software NX 10. |
2200225 |
Siemens PLM believes that the problem you reported where the problem that bolt circle centerline is not right output by [2D Exchange] will be resolved by code changes made to the upcoming release of our software NX 10. |
2200425 |
Siemens PLM believes that the problem you reported where When you convert a 3D drawing "2D Exchange","PMI" disappear will be resolved by code changes made to the upcoming release of our software NX 10. |
2200543 |
Siemens PLM believes that the problem you reported where the UfSession.Tabnot.SetCellText does not set the Japanese character correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2200666 |
Siemens PLM believes that the problem you reported where multiple warnings is displayed by using expression block will be resolved by code changes made to the upcoming release of our software NX 10. |
2200682 |
Siemens PLM believes that the problem you reported where the "Copy Connected Parts" option in Transform path command dialog was not working will be resolved by code changes made to the upcoming release of our software NX 10. |
2200922 |
Siemens PLM believes that the problem you reported where incorrect preview display while editing line segments will be resolved by code changes made to the upcoming release of our software NX 10. |
2201512 |
Siemens PLM believes that the problem you reported where based on the selection order, Simple interference result changes will be resolved by code changes made to the upcoming release of our software NX 10. |
2201589 |
Siemens PLM believes that the problem you reported where the bundle factor calculation in the documentation is wrong will be resolved by the changes made to the release of our product NX 10 Documentation |
2202706 |
Siemens PLM believes that the problem you reported where New revision of component cannot be opened using Reopen Assembly function will be resolved by code changes made to the upcoming release of our software NX 10. |
2202996 |
Siemens PLM believes that the problem you reported where the GRIP DEFBAN command does not display the defined message until the Plot menu has been displayed once will be resolved by code changes made to the upcoming release of our software NX 10 ph18. |
2203016 |
Siemens PLM believes that the problem you reported where toggling off Specific Component Color and Specific Translucency removed the color but not the translucency on a suppressed feature after the feature was unsuppressed, will be resolved by code changes made to the release of our product NX 10. |
2203864 |
Siemens PLM believes that the problem you reported where a Path/Stock is hyper-extended will be resolved by code changes made to the upcoming release of our software NX 10. |
2204075 |
Siemens PLM believes that the problem you reported where place part causes existing chamfer feature to be failed from the stock will be resolved by code changes made to the upcoming release of our software NX 10. |
2204559 |
Siemens PLM believes that the problem you reported where when executing replace part, use specify item dialog cannot find member in part family will be resolved by code changes made to the upcoming release of our software NX 10. |
2205033 |
Siemens PLM believes that the problem you reported where Overstock was not displayed correctly, will be resolved by code changes made to the release of our product NX 10. |
2205142 |
Siemens PLM believes that the problem you reported where FittingPortCollection is not returning FittingPort will be resolved by code changes made to the upcoming release of our software NX 10. |
2205217 |
Siemens PLM believes that the problem you reported where Mean radius of curvature for face radius calculation is documented incorrectly will be resolved by code changes made to the upcoming release of our software NX 10. |
2205537 |
Siemens PLM believes that the problem you reported where Instance Feature of UDF is not included in the Active Feature Group will be resolved by code changes made to the upcoming release of our software NX 10. |
2205768 |
Siemens PLM believes that the problem you reported where you are unable to change the arrow position of an Identification Symbol, will be resolved by code changes made to the upcoming release of our software NX 10. |
2205852 |
Siemens PLM believes that the problem you reported where UIStyler.PropertyPage.SetFocus() shows attribute error will be resolved by code changes made to the upcoming release of our software NX 10 |
2205971 |
Siemens PLM believes that the problem you reported where a placed part not positioned correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2206068 |
Siemens PLM believes that the problem you reported where text alignment was not remembered when using a template file, will be resolved by code changes made to the upcoming release of our software NX 10. |
2206139 |
Siemens PLM believes that the problem you reported where Ordinate dimension disappears when the dimension is moved will be resolved by code changes made to the release of our product NX version 10. |
2206200 |
Siemens PLM believes that the problem you reported where Askcentroid method not working correctly in remoting mode will be resolved by code changes made to the upcoming release of our software NX 10. |
2206667 |
Siemens PLM believes that the problem you reported where it was not possible to open the supplied harness assembly, will be resolved by code changes made to the upcoming release of our software NX 10. |
2206829 |
Siemens PLM believes that the problem you reported where instance feature is not in Feature Group when UDF is exploded will be resolved by code changes made to the upcoming release of our software in NX 10. |
2207729 |
Siemens PLM believes that the problem you reported where "Label on Parent" does not move will be resolved by code changes made to the upcoming release of our software NX 10. |
2207871 |
Siemens PLM believes that the problem you reported where Stock disappears when edit spline path will be resolved by code changes made to the upcoming release of our software NX 10. |
2207873 |
Siemens PLM believes that the problem you reported where stock gets rotated when deleting a path segment will be resolved by code changes made to the upcoming release of our software NX 10. |
2207909 |
Siemens PLM believes that the problem you reported where user defined expression loses its category when it is used in Offset Expression will be resolved by code changes made to the upcoming release of our software NX 10. |
2208244 |
Siemens PLM believes that the problem you reported where Saved measurements on Routing stock are not updating when stock dia is edited will be resolved by code changes made to the upcoming release of our software NX 10. |
2208436 |
Siemens PLM believes that the problem you reported where "Some joints and connectors of NX 6 motion models cannot be edited on NX 8.5" will be resolved by code changes made to the upcoming release of our software NX 10. |
2208537 |
Siemens PLM believes that the problem you reported where Some unknown lines come out in the base view with "Lightweight" Representation will be resolved by code changes made to the release of our product NX 10 and future MP of NX 9.0.3 |
2208781 |
Siemens PLM believes that the problem you reported where UF_MB_ask_button_sensitivity() always returns button sensitivity as UF_MB_OFF is updated in NX 10 documentation. UF header is updated to provide the additional information in the description of the function. A sensitivity request is valid only on customer buttons, not NX buttons since they are grayed out while running an NXOpen program. |
2208790 |
Siemens PLM believes that the problem you reported where the gwif dialog id changed and it could not be played back will be resolved by code changes made to the upcoming release of our software NX 10. |
2208828 |
Siemens PLM believes that the problem you reported where warning occurs in through curves feature will be resolved by code changes made to the release of our product NX 10. |
2208951 |
Siemens PLM believes that the problem you reported where the dialog box of the simple measure command is changed after apply will be resolved by code changes made to the release of our product NX 10. |
2209440 |
Siemens PLM believes that the problem you reported where revolve in UDF does not give warnings for section string missing when using suppress by expression will be resolved by code changes made to the upcoming release of our software NX 10. |
2209458 |
Siemens PLM believes that the problem you reported where Routing Characteristics are not updated with Replace part will be resolved by code changes made to the upcoming release of our software NX 10. |
2209474 |
Siemens PLM believes that the problem you reported where while editing items "< >" is displayed on ANT will be resolved by code changes made to the upcoming release of our software NX 10. |
2209636 |
Siemens PLM believes that the problem you reported where "Drafting View unnecessary curves are displayed if set lightweight representation" will be resolved by code changes made to the release of our product NX 9.0.3 next-MP and NX 10. |
2209878 |
Siemens PLM believes that the problem you reported where the "Infer Thickness" option of the MetaForm command remains gray will be resolved by code changes made to the upcoming release of our software NX 10. |
2209908 |
Siemens PLM believes that the problem you reported where Reset Window Position did not reset the position for the User Tool dialogs will be resolved by code changes made to the upcoming release of our software NX 10. |
2209980 |
Siemens PLM believes that the problem you reported where if Engagement is specified for a port, Lock Engagement becomes unavailable will be resolved by code changes made to the release of our product NX 10. |
2210047 |
Siemens PLM believes that the problem you reported where parallel route line has difference in angle when Lock Length is ON will be resolved by code changes made to the upcoming release of our software NX 10. |
2210128 |
Siemens PLM believes that the problem you reported where not able to export dxf correctly will be resolved by code changes made to the upcoming release of our software NX 10. Note: During export user needs to version up weld symbol, So that it will update its correct location then translate it to dxf. |
2210134 |
Siemens PLM believes that the problem you reported where [Expot to Spreadsheet]:Excel title is garbled will be resolved by code changes made to the upcoming release of our software NX 10. |
2210230 |
Siemens PLM believes that the problem you reported where PTS Stock created in NX 8.5 can not be modified will be resolved by code changes made to the upcoming release of our software NX 10. |
2210231 |
Siemens PLM believes that the problem you reported where "A stock cannot be added to a Run by a work part" will be resolved by code changes made to the upcoming release of our software NX 10. |
2210245 |
Siemens PLM believes that the problem you reported where Datum Feature symbol and Datum Target dialogs behaves inconsistently will be resolved by code changes made to the release of our product NX 10. |
2210978 |
Siemens PLM believes that the problem you reported where "If Suppressed Component is added in Assembly Structure unable to close all parts" will be resolved by code changes made to the upcoming release of our software NX 10. |
2211008 |
Siemens PLM believes that the problem you reported where Journal replay fails while creating an Edge Blend in History-Free Mode will be resolved by code changes made to the upcoming release of our software NX 10. |
2211403 |
Siemens PLM believes that the problem you reported where unexpected angle is added to routing line by moving JT body will be resolved by code changes made to the upcoming release of our software NX 10. |
2211569 |
Siemens PLM believes that the problem you reported where Virtual Intersection Curve is not created will be resolved by code changes made to the upcoming release of our software NX 10. Problems A & C have been fixed in NX 10. Some additional tweaks are needed for the views in problem scenario A to display correctly: 1) the smooth edge tolerance for both views has to be set to 1.5, and 2) the view tolerance for the upper left view has to be changed to 0.2. Problem B may be due to geometry that fails Examine Geometry. Please correct the model. |
2211577 |
Siemens PLM believes that the problem you reported where some wrong virtual intersection curves are created will be resolved by code changes made to the upcoming release of our software NX 9.0.1 and NX 10. |
2212071 |
Siemens PLM believes that the problem you reported where "Template Assembly setting is not saved when reopen Qualifying Routing Assembly" will be resolved by code changes made to the upcoming release of our software NX 10. |
2212121 |
Siemens PLM believes that the problem you reported where "Internal Error occurs when using Stock Offset Surface method" will be resolved by code changes made to the upcoming release of our software NX 10. |
2212132 |
Siemens PLM believes that the problem you reported where execution of assign corner generates an Internal Error will be resolved by code changes made to the upcoming release of our software NX 10. |
2212191 |
Siemens PLM believes that the problem you reported where "Some features are not stored in original layer after exploding UDF" will be resolved by code changes made to the upcoming release of our software NX 10. |
2212200 |
Siemens PLM believes that the problem you reported where the status line is garbled in Japanese NX when the run item is activated will be resolved by code changes made to the upcoming release of our software NX 10. |
2212280 |
Siemens PLM believes that the problem you reported where 'out of date' features fails 'copy body cut' in checkmate will be resolved by code changes made to the release of our product NX 10. |
2212528 |
Siemens PLM believes that the problem you reported where "Auto Size Text" of Tabular Note did not give consistent result when uppercase characters were input into cell will be resolved by code changes made to the upcoming release of our software NX 10.Existing tabular notes need to be upgraded to NX 10 version to get the fix. |
2212569 |
Siemens PLM believes that the problem you reported where documented UF_DRF_ask_ann_data Method does not work for new leaders has been corrected in NX 10 documentation. |
2212718 |
Siemens PLM believes that the problem you reported where wrong or extra lines are displayed in the virtual intersections Curve will be resolved by code changes made to the upcoming release of our software NX 10.0 |
2213266 |
Siemens PLM believes that the problem you reported where The results of "Boolean Face Properties from" command are different depending upon the type of selection of tool body will be resolved by code changes made to the upcoming release of our software NX 10. |
2213296 |
Siemens PLM believes that the problem you reported where Virtual Intersections lines are not displayed in isometric view will be resolved by code changes made to the upcoming release of our software NX 10. |
2213546 |
Siemens PLM believes that the problem you reported where Diameter reference's circle bracket is missing in the exported DXF will be resolved by code changes made to the upcoming release of our software NX 10. |
2213582 |
Siemens PLM believes that the problem you reported where outside dimension line is extended unexpectedly depending on placement option will be resolved by code changes made to the upcoming release of our software NX 10. |
2213612 |
Siemens PLM believes that the problem you reported where Assign corner gives error message as "Routing: Error creating fillet for bend corner "will be resolved by code changes made to the upcoming release of our software NX 10. |
2213680 |
Siemens PLM believes that the problem you reported where IFERR minor word of ISOCRV command is ignored in GRIP will be resolved by code changes made to the release of our product NX 10. |
2213718 |
Siemens PLM believes that the problem you reported where arc centers were not selectable after entering the tools-customize dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
2214039 |
Siemens PLM believes that the problem you reported where RCPs don't follow path motion in FormBoard Layout will be resolved by code changes made to the upcoming release of our software NX 10. |
2214140 |
Siemens PLM believes that the problem you reported where Create Linear Path command is invalid in Routing will be resolved by code changes made to the upcoming release of our software NX 10. |
2214210 |
Siemens PLM believes that the problem you reported where the incorrect results reported in the Report Shortest Tool function will be resolved by code changes made to the upcoming release of our software NX 10. |
2214357 |
Siemens PLM believes that the problem you reported where RUN attributes cannot be fetched in NX7.5 using UF_ATTR_read_value will be resolved by code changes made to the upcoming release of our software NX 10. |
2214401 |
Siemens PLM believes that the problem you reported where insufficient Documentation for NXOpen > WCS > SetCoordinateSystem has been updated in documentation of NX 10. |
2214835 |
Siemens PLM believes that the problem you reported where Part number cannot be changed by Mirror Assembly will be resolved by code changes made to the upcoming release of our software NX 10. |
2215098 |
Siemens PLM believes that the problem you reported where Solid of a cross-section view is also exported to JT will be resolved by code changes made to the upcoming release of our software NX 9.0.3 & NX 10 |
2215363 |
Siemens PLM believes that the problem you reported where Weld Assistant V-Groove with Root opening fails on curved faces will be resolved by code changes made to the upcoming release of our software NX 10. This problem can be worked around in the current release by changing the taper method to "From End Face". |
2215419 |
Siemens PLM believes that the problem you reported where When I exported a solid body into JT file, JT has two solid bodies will be resolved by code changes made to the upcoming release of our software NX9.0.3 & NX 10 |
2215518 |
Siemens PLM believes that the problem you reported where cornerCut location of the numbers that are defined in the "Chamfer" is different will be resolved by code changes made to the release of our product NX version 10. |
2215633 |
Siemens PLM believes that the problem you reported where Face Normal line direction is not correct, will be resolved by code changes made to the upcoming release of our software NX 10. |
2215754 |
Siemens PLM believes that the problem you reported where Hem flange cannot be created when Datum CSYS is at some positions will be resolved by code changes made to the upcoming release of our software NX 10. |
2216106 |
Siemens PLM believes that the problem you reported where documentation of NXOpen wrapper 'free' methods are not well documented will be resolved by code changes made to the upcoming release of our software NX 10. |
2216354 |
Siemens PLM believes that the problem you reported where extra wrong virtual intersection curves are created will be resolved by code changes made to the upcoming release of our software NX 10. |
2216465 |
Siemens PLM believes that the problem you reported where Excel title by Export to Spreadsheet is garbled will be resolved by code changes made to the release of our product NX version 10. |
2216541 |
Siemens PLM believes that the problem you reported where the Virtual Intersections curves are ON, but the edges are broken in the drafting view will be resolved by code changes made to the upcoming release of our software NX 10. |
2216637 |
Siemens PLM believes that the problem you reported where "Open the jt file in NX and only some datum display" will be resolved by code changes made to the upcoming release of our software NX 10. |
2216866 |
Siemens PLM believes that the problem you reported where at some parts the ports are not connected when "Move Component" command is used will be resolved by code changes made to the upcoming release of our software NX 10. |
2217114 |
Siemens PLM believes that the problem you reported where after playback the data of NX 7.5 in NX 8.5, direction of Law Extension is changed will be resolved by code changes made to the upcoming release of our software NX 10. |
2217527 |
Siemens PLM believes that the problem you reported where UFTabnot>AskCellText() returns wrong character code for Japanese string will be resolved by code changes made to the upcoming release of our software NX 10. |
2217636 |
Siemens PLM believes that the problem you reported where UFTabnot.SetCellText() can't set text properly if text mode is UFText.ModeS.Utf8 will be resolved by code changes made to the upcoming release of our software NX 10. |
2217704 |
Siemens PLM believes that the problem you reported where the incorrect results reported in the Report Shortest Tool function will be resolved by code changes made to the upcoming release of our software NX 10. |
2217783 |
Siemens PLM believes that the problem you reported where internal error occurs when the stock is de-selected in Create Terminals dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
2217842 |
Siemens PLM believes that the problem you reported where replacement component is not placed in the specified position will be resolved by code changes made to the upcoming release of our software NX 10. |
2218548 |
Siemens PLM believes that the problem you reported where "Customized [USER_validate_dataset_name] of USER_EXIT does not work as we expect" will be resolved by code changes made to the upcoming release of our software NX 10 and TC10.1.1 |
2219223 |
Siemens PLM believes that the problem you reported where pressing MB2 in selection steps for Pad feature makes a Top Face highlight will be resolved by code changes made to the upcoming release of our software NX 10. |
2219237 |
Siemens PLM believes that the problem you reported where a gap is created when [Move Face] is executed on rib, will be resolved by code changes made to the upcoming release of our software NX 10. |
2219348 |
Siemens PLM believes that the problem you reported where If set "Boolean face Properties" as Tool Body can't update Trim & Split faces" will be resolved by code changes made to the release of our product NX version NX 10. |
2219472 |
Siemens PLM believes that the problem you reported where Stock_key attribute defined in ptb file is not added as a feature attribute will be resolved by code changes made to the upcoming release of our software NX 10. |
2219482 |
GDT symbol move when update the drawing in NX 9 beta. |
2219607 |
Siemens PLM believes that the problem you reported where Stock length option in Routing BOM does not work with single click on [Apply] will be resolved by code changes made to the upcoming release of our software NX 10. |
2219777 |
Siemens PLM believes that the problem you reported where NX 8.5.1 fail to open solidwork file(.sldasm) that was able to open in NX 8.0.2 will be resolved by code changes made to the upcoming release of our software NX 10. |
2219971 |
Siemens PLM believes that the problem you reported where NX documentation explains about Grid lines even though the lines are removed from NX will be resolved by code changes made to the upcoming release of our software NX 10. |
2220173 |
Siemens PLM believes that the problem you reported where incorrect default Rectangular stock(HVAC) orientation will be resolved by code changes made to the upcoming release of our software NX 10. |
2220805 |
Siemens PLM believes that the problem you reported where characters disappear in attribute name column of cut sheet annotation will be resolved by code changes made to the upcoming release of our software NX 10. |
2220877 |
Siemens PLM believes that the problem you reported where Trim and Extend(Make Corner)" failed will be resolved by code changes made to the upcoming release of our software NX 10. |
2221348 |
Surface remains selected when the "Thread" was executed. |
2221393 |
Siemens PLM believes that the problem you reported where UGPART fails to import if object_name has upper case naming rule attached to it will be resolved by code changes made to the upcoming release of our software NX 10. |
2221445 |
Siemens PLM believes that the problem you reported where a new port is created in spite of turning OFF "create interpart link" will be resolved by code changes made to the upcoming release of our software NX 10. |
2221450 |
Siemens PLM believes that the problem you reported where Even if the assembly is saved, the itemID is not updated will be resolved by code changes made to the upcoming release of our software NX 10. |
2221455 |
Siemens PLM believes that the problem you reported where "Cannot export the Chinese characters in feature control frame to DWG" will be resolved by code changes made to the upcoming release of our software NX 10 |
2221479 |
Siemens PLM believes that the problem you reported where The scope of [Feature Group Types Allowed] is wrong in Customer Default will be resolved by code changes made to the upcoming release of our software NX 10. |
2221509 |
Siemens PLM believes that the problem you reported where "Slope analysis result is wrong in work part" will be resolved by code changes made to the upcoming release of our software NX 10. |
2221623 |
Siemens PLM believes that the problem you reported where inconsistent behaviour of "Same Position in All" arrangements option will be resolved by code changes made to the upcoming release of our software NX 10. |
2221886 |
Siemens PLM believes that the problem you reported where "Number of selected components" is displayed in connection status report will be resolved by code changes made to the upcoming release of our software NX 10. |
2221945 |
Siemens PLM believes that the problem you reported where a pair of flanges is arranged, though Post placement is not defined will be resolved by code changes made to the upcoming release of our software NX 10. |
2221993 |
Siemens PLM believes that the problem you reported where if Contour Flange relief has local value, bend definition method is not updated will be resolved by code changes made to the upcoming release of our software NX 10. |
2222291 |
Siemens PLM believes that the problem you reported where Status icon for "work part" in Electrical connection navigator is not updated will be resolved by code changes made to the upcoming release of our software NX 10. |
2222524 |
Siemens PLM believes that the problem you reported where internal error occurs when exporting the connection list by Export All will be resolved by code changes made to the upcoming release of our software NX 10 and the future releases of NX 9.0.2 and NX 9.0.3. |
2222528 |
Siemens PLM believes that the problem you reported where legacy face option was set as Enable but the face option is not displayed on the dialog of wave geometry linker will be resolved by code changes made to the upcoming release of our software NX 10.0 |
2222540 |
Siemens PLM believes that the problem you reported where "All reference sets is not displayed in Replace Reference Set Dialog." will be resolved by code changes made to the upcoming release of our software NX 10. |
2222556 |
Siemens PLM believes that the problem you reported where Datum feature symbol created on dimension line bend will be resolved by code changes made to the upcoming release of our software NX 10. |
2222567 |
Siemens PLM believes that the problem you reported where internal error occurs when executing redo after undoing auto route will be resolved by code changes made to the upcoming release of our software NX 10. |
2222683 |
Siemens PLM believes that the problem you reported where "stock not found" appears & connection is not routed, while trying to auto route will be resolved by code changes made to the upcoming release of our software NX 10. |
2222811 |
Siemens PLM believes that the problem you reported where non associative mirror body is inconsistently associative for the threads will be resolved by code changes made to the upcoming release of our software NX 10. |
2222937 |
Siemens PLM believes that the problem you reported regarding NX System Attributes will be resolved by code changes made to the upcoming release of our software NX 10. |
2223270 |
Siemens PLM believes that the problem you reported where the action result of a reset button in face blend does not work will be resolved by code changes made to the upcoming release of our software NX 10. |
2223318 |
Siemens PLM believes that the problem you reported where sleep function cannot be used in block styler code will be resolved by the updated documentation of NX 10. |
2223519 |
Siemens PLM believes that the problem you reported where style of note cannot be edited after setting the type of leader to "Datum" will be resolved by code changes made to the upcoming release of our software NX 10. |
2224002 |
Siemens PLM believes that the problem you reported where display color of the stock wire will change will be resolved by code changes made to the upcoming release of our software NX 10. |
2224054 |
Siemens PLM believes that the problem you reported where an unknown dialog is displayed with Simulation Wizard of Chinese NX will be resolved by code changes made to the upcoming release of our software NX 10. |
2224070 |
Siemens PLM believes that the problem you reported about improving the performance of Results Manipulation about ABAQUS odb files will be resolved by code changes made to the release of our product NX 10. |
2224298 |
Siemens PLM believes that the problem you reported where "Within Work part Only- filter does not work well in sketcher mode" will be resolved by code changes made to the upcoming release of our software NX 10. |
2224430 |
Siemens PLM believes that the problem you reported where the unit of viscous damping regarding rotation will be resolved by code changes made to the upcoming release of our software NX 10. |
2224675 |
Siemens PLM believes that the problem you reported where "Not displayed correctly "Modified" and "Created" text in Japanese" will be resolved by code changes made to the upcoming release of our software NX 10. |
2224679 |
Siemens PLM believes that the problem you reported where Japanese translation of "Find Object" is wrong will be resolved by code changes made to the upcoming release of our software NX 10. |
2224804 |
Siemens PLM believes that the problem you reported where linear Dimension 'BlockID' value doesn't accept under bar string will be resolved by code changes made to the upcoming release of our software NX 10. |
2224954 |
Siemens PLM believes that the problem you reported where "Some specific Chinese characters of folder name show messy code in TCIN" will be resolved by code changes made to the upcoming release of our software NX 10 release. |
2224986 |
Siemens PLM believes that the problem you reported where warning mistake with the model check will be resolved by code changes made to the upcoming release of our software NX 10. |
2225167 |
Siemens PLM believes that the problem you reported where system performance is very slow while creating a .sim file and .dat file will be resolved by code changes made to the release of our software NX 10. |
2225270 |
Siemens PLM believes that the problem you reported where SetEnumMembers() method is failing to set enum members in dialogShown_cb() is updated in UI Styler documentation of NX 10. NX does not support changing the options on a radio box after creation. NOTE: Changing the list of options after initialization is only supported for the Option Menu presentation style. |
2225373 |
Siemens PLM believes that the problem you reported where the minute face restores on editing 2D mesh without updating will be resolved by code changes made to the upcoming release of our software NX 10. |
2225395 |
Siemens PLM believes that the problem you reported where the displacement CSYS of node is not written in solver input file will be resolved by code changes made to the release of our product NX version 10.0 |
2225453 |
Siemens PLM believes that the problem you reported where quick extend can miss some intersections with sketches on planes at non-zero angles to a primary coordinate system plane will be resolved by code changes made to the upcoming release of our software NX 10. |
2225560 |
Siemens PLM believes that the problem you reported where "View style in VW_create_wizard doesn't follow the default settings" will be resolved by code changes made to the upcoming release of our software NX 10. |
2225562 |
Siemens PLM believes that the problem you reported on "How to calculate the Conic shape in case that "Rho Type" is "Relative"" will be resolved by code changes made to the upcoming release of our software NX 10. |
2225591 |
Siemens PLM believes that the problem you reported where incorrect note in NX documentation"this functionality is available only with Teamcenter2007" will be resolved by the changes made to the upcoming release of our software NX 10 documentation. |
2225661 |
Siemens PLM believes that the problem you reported where the assembly does not get exported using ug_export will be resolved by code changes made to the upcoming release of our software NX 10. |
2225829 |
Siemens PLM believes that the problem you reported where NX documentation mentioned that springback options are available for both intermediate and complete unforming will be resolved by the changes made to the upcoming release of our software NX 10 The updated document will be as follows Use the Analyze Formability One-step command to flatten all or some faces of a sheet metal part using FEM analysis and calculate the thinning, stress, strain, and springback to predict the risk of forming. You can: Perform complete or intermediate unforming, or flatten a Sheet Metal part. Output the flattened profile or springback faceted bodies for complete part unforming. You can also specify the target region and the unform region from a different sheet body. Define different constraint types, both geometry and process, to control unforming. |
2225838 |
About the error to the Custom Symbol when placed. |
2225898 |
Siemens PLM believes that the problem you reported where additional documentation is needed for &ATTTL is fixed in NX 10 documentation. |
2225948 |
Siemens PLM believes that the problem you reported where moving the view takes time showing updating objects will be resolved by code changes made to the upcoming release of our software NX 10. The issue in which user was experiencing problem with the hatch update is now slightly improved. |
2225955 |
Siemens PLM believes that the problem you reported where shortcut toolbar to provide coincident constraint is not available will be resolved by code changes made to the upcoming release of our software NX 10. |
2225990 |
Siemens PLM believes that the problem you reported where section view label letters are not created in alphabetical order will be resolved by code changes made to the upcoming release of our software NX 10. |
2226012 |
Siemens PLM believes that the problem where JT of a tool body remains after assembly cut operation is fixed in release NX 10. |
2226070 |
Siemens PLM believes that the problem you reported where "Edit Object Display" select same component twice will be resolved by code changes made to the upcoming release of our software NX 10. |
2226078 |
Siemens PLM believes that the problem you reported where ,Blank value is displayed in DB_SEED_PART_USED after mapping, will be resolved by code changes made to the upcoming release of our software NX 10. |
2226210 |
Siemens PLM believes that the problem you reported where stress component is not shown correctly for Beam Element will be resolved by code changes made to the release of our product NX 10. |
2226240 |
Siemens PLM believes that the problem you reported where CreateTrimCornerBuilder() method gives an error 'No intersection point' will be resolved by code changes made to the upcoming release of our software NX 10 |
2226413 |
Siemens PLM believes that the problem you reported where Sketch does not follow a model edit, will be resolved by code changes made to the release of our product NX version 10. |
2226419 |
Siemens PLM believes that the problem you reported where Display condition of tool body after executing Subtract, will be resolved by code changes made to the release of our product NX version 10.0 |
2226432 |
Siemens PLM believes that the problem you reported where the "D1 - Volumetric Deformation Constant" PLSOLID property has the wrong measure will be resolved by code changes made to the upcoming release of our software NX 10. |
2226481 |
Siemens PLM believes that the problem you reported where journal replay changes Sketch environment to Modeling environment will be resolved by code changes made to the upcoming release of our software NX 10 |
2226591 |
Siemens PLM believes that the problem you reported where optimization spreadsheet does not contain individual graphs will be resolved by code changes made to the release of our software NX 10. |
2226821 |
Siemens PLM believes that the problem you reported where Macro cannot be playback in NX 8.5 will be resolved by code changes made to the upcoming release of our software NX 10. |
2226827 |
Siemens PLM believes that the problem you reported where view break is not created will be resolved by code changes made to the upcoming release of our software NX 10. |
2226863 |
Siemens PLM believes that the problem you reported where UF_set_variable() fails to set the multibyte value on windows 7 will be resolved by code changes made to the release of our product NX 10. |
2226864 |
Siemens PLM believes that the problem you reported where UF_translate_variable() fails to get the multi byte value on windows 7 will be resolved by code changes made to the release of our product NX version 10. |
2226975 |
Siemens PLM believes that the problem you reported where lines inside the view cannot be deleted will be resolved by code changes made to the upcoming release of our software NX 10. |
2226992 |
Siemens PLM believes that the problem you reported where Relief Angle (RA) is not applied will be resolved by code changes made to the upcoming release of our software P10 /phase 5. |
2227238 |
Siemens PLM believes that the problem you reported where curves is not associated with "Objects in the view" will be resolved by code changes made to the upcoming release of our software NX 10. |
2227241 |
Siemens PLM believes that the problem you reported where Redo does not become active after executing undo of opening component will be resolved by code changes made to the upcoming release of our software NX 10. |
2227270 |
Siemens PLM believes that the problem you reported where "Electrical and Mechanical application removes Define Deformable Part from Menus." will be resolved by code changes made to the upcoming release of our software NX 10. |
2227305 |
Siemens PLM believes that the problem you reported where Rotation handle is moved from the center of rotation, will be resolved by code changes made to the upcoming release of our software NX 10. |
2227314 |
Siemens PLM believes that the problem you reported where more time was consumed on CONM2 creation with 1D connection on comparing without 1D connection will be resolved by code changes made to the upcoming release of our software NX 10. |
2227332 |
Siemens PLM believes that the problem you reported where tool body of the Unite has been changed will be resolved by code changes made to the upcoming release of our software NX 10. |
2227479 |
Siemens PLM believes that the problem you reported where Attribute value is not getting updated in TC from NX will be resolved by code changes made to the release of our product NX version 10. |
2227488 |
Siemens PLM believes that the problem you reported where Assembly and part are opened with modified flag by partial loading will be resolved by code changes made to the upcoming release of our software NX 10. |
2227504 |
Siemens PLM believes that the problem you reported where Extension of the image file name is not correct while saving it will be resolved by code changes made to the upcoming release of our software NX 10. |
2227510 |
Siemens PLM believes that the problem you reported where "A Fixed, constraint gets delete when active and deactivate group" will be resolved by code changes made to the upcoming release of our software NX 10. |
2227514 |
Siemens PLM believes that the problem you reported where nested rigid groups cannot be edited, will be resolved by code changes made to the upcoming release of our software NX 10. |
2227587 |
Siemens PLM believes that the problem you reported where "Behavior of the standard of [Ellipse] angle of a view" will be resolved by code changes made to the upcoming release of our software NX 10. |
2227589 |
Siemens PLM believes that the problem you reported where unable to paste error occurs on UDF insert will be resolved by code changes made to the upcoming release of our software NX 10. |
2227611 |
Siemens PLM believes that the problem you reported where density attribute is mapped with incorrect unit from NX to Teamcenter will be resolved by code changes made to the upcoming release of our software Nx10.0 by adding an option to the Customer Defaults that allows the setting of display units for the mass property attributes in NX. These units can then be set to match the display units in TC. |
2227687 |
Siemens PLM believes that the problem you reported where quick extend can miss some intersections with sketches on planes at non-zero angles to a primary coordinate system plane will be resolved by code changes made to the upcoming release of our software NX 10. |
2227752 |
Siemens PLM believes that the problem you reported where Unable to select reference curves for creating "Intersection Point" will be resolved by code changes made to the upcoming release of our software NX 10. |
2227755 |
Siemens PLM believes that the problem you reported about the start point of polygon edge will be resolved by code changes made to the upcoming release of our software NX 10. |
2227764 |
Siemens PLM believes that the problem you reported where the mesh is not updated normally will be resolved by code changes made to the upcoming release of our software NX 10. |
2227817 |
Siemens PLM believes that the problem you reported where When a 2d exchange file created with custom dimension standard, is opened in new NX session with ISO standard, some of the new dimensions still carry custom standard, will be resolved by code changes made to the upcoming release of our software NX 10. |
2227899 |
Siemens PLM believes that the problem you reported where the internal error occurs when a spreadsheet is exported by "identify" command will be resolved by code changes made to the release of our product NX version 10. |
2228003 |
Siemens PLM believes that the problem you reported where an improvement on the contents of help of Maximum Clearance is required will be resolved by code changes made to the upcoming release of our software NX 10 Documentation. New images have been added to the Measure distance dialog box for the Measurement-> Distance-> all options. |
2228028 |
Siemens PLM believes that the problem you reported where CreateInstantiatedUdf does not assign the attribute to new UDF instantiation will be resolved by code changes made to the upcoming release of our software NX 10. |
2228090 |
Siemens PLM believes that the problem you reported where different item is opened in "Advanced Search" will be resolved by code changes made to the upcoming release of our software NX 10. |
2228199 |
Siemens PLM believes that the problem you reported where the "Initial Temperatures Default (TEMPD)" default value is 20.0°C instead of blank for SOLs 106, 601, 701 and 153 be resolved by code changes made to the upcoming release of our software NX 10. |
2228374 |
Siemens PLM believes that the problem you reported where opening part file failed will be resolved by code changes made to the upcoming release of our software NX 10, NX 9.0.1 and upcoming MPs to NX 8.5.3 and NX 8.5.2. |
2228383 |
Siemens PLM believes that the problem you reported where a portion of solid body is lost when executing closed corner will be resolved by code changes made to the upcoming release of our software NX 10. |
2228451 |
Siemens PLM believes that the problem you reported where Help Page of User Defined Feature Wizard was not correct will be resolved by code changes made to the upcoming release of our software NX 10. |
2228493 |
If columns isn't set in the "Manage Materials" dialog, An internal error occurs. |
2228589 |
Siemens PLM believes that the problem you reported where Bend Relief is not created by Convert to Sheet Metal command will be resolved by code changes made to the release of our product NX 10. |
2228608 |
"Width" option of "Local Setting" for graph editing do not function correctly. |
2228665 |
Siemens PLM believes that the problem you reported where EPSP & EPSW values are written in deck though P & W of "CONV" on NLPARM was disabled will be resolved by code changes made to the upcoming release of our software NX 10. |
2228670 |
Siemens PLM believes that the problem you reported where Status returns back to Regenerate when changing Default Clearance in Divide by Holder will be resolved by code changes made to the upcoming release of our software P10 phase 6. |
2228707 |
Siemens PLM believes that the problem you reported where the notation of "Repeat Command Drop-down" in sketch environment has problem, will be resolved by code changes made to the upcoming release of our software NX 10. |
2228710 |
Siemens PLM believes that the problem you reported where an alert is displayed if the link to a point is created using the wave geometry linker command and the alert does not disappear until user manually closes will be resolved by code changes made to the upcoming release of our software NX 10. |
2228711 |
Siemens PLM believes that the problem you reported where while editing the assembly constraints the "Alerts: Assembly constraints are delayed in session" disappears will be resolved by code changes made to the upcoming release of our software NX 10. |
2228810 |
"Offset" option of "Node Translate" doesn't function correctly. |
2228811 |
Can not add the new nodes to an existing the node group. |
2228813 |
Siemens PLM believes that the problem you reported where "Remove selected material assignment" button from the "Assign Materials" dialog box topic will be removed by changes made to the upcoming release of our software NX 10 Documentation. |
2228902 |
Siemens PLM believes that the problem you reported where GetUserAttribute() fails to get more than 132 multi byte char will be resolved by code changes made to the upcoming release of our software NX 10 and this was documented too in NX 10. |
2228962 |
Siemens PLM believes that the problem you reported where "When Execute "Minimum Radius" in information window shows 1 point, But 2 points " will be resolved by code changes made to the upcoming release of our software NX 10. |
2228969 |
There are not images of the "Plot" and the "Overlay" icon. |
2228970 |
About "3D Tetrahedral Mesh" in Design Sim, "OK" and "Apply" don't highlight. |
2228976 |
When"New Annotation" is canceled, Synchronization of post view is canceled. |
2229005 |
Siemens PLM believes that the problem you reported where about the problem of the Documentation stated that Elemental Response Location was available for Beam Element Force and Shell Stress Resultant Results in the Evaluate CSD Function Response dialog box has been corrected for the NX 10 documentation. |
2229073 |
Siemens PLM believes that the problem you reported where "Edit connection wizard"dialog gets closed if back button is clicked will be resolved by code changes made to the upcoming release of our software NX 10 |
2229076 |
Siemens PLM believes that the problem you reported where the title of "Edit connection wizard "dialog has been incorrectly translated in Japanese environment will be resolved by code changes made to the upcoming release of our software NX 10. |
2229110 |
Siemens PLM believes that the problem you reported where the value of diameter is changed when editing bolt connection will be resolved by code changes made to the upcoming release of our software NX 10. |
2229177 |
Record Text is garbaged in Fine Tracking on Japanese mode. |
2229237 |
Siemens PLM believes that the problem you reported where associated objects not translated correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2229277 |
Siemens PLM believes that the problem you reported where the problem which an error will generate if By Result Range of Identify is used will be resolved by code changes made to the upcoming release of our software NX 10. |
2229282 |
Siemens PLM believes that the problem you reported where RPO dimensions associated with edges that have 'mandatory reuse' face(s) did not work correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2229316 |
Siemens PLM believes that the problem you reported where the message is not translated in Japanese will be resolved by code changes made to the upcoming release of our software NX 10. |
2229331 |
Siemens PLM believes that the problem you reported where "Leader is changed, when tired to change the style of datum feature symbol" will be resolved by code changes made to the release of our product NX version NX 10. |
2229339 |
Siemens PLM believes that the problem you reported where Poles of Rational output of Aesthetic Face Blend does not get snapped will be resolved by code changes made to the upcoming release of our software NX 10. |
2229372 |
Siemens PLM believes that the problem you reported where "When use Exact (Representation) in View Style, extracted edges is displayed" will be resolved by code changes made to the upcoming release of our software NX 10. |
2229533 |
Siemens PLM believes that the problem you reported where UF_MODL_ask_curve_points runs slower will be resolved by code changes made to the upcoming release of our software NX 10. |
2229554 |
When the slot is not horizontal, dimension is not available. |
2229586 |
If "i-prt" isn't used, The turn of save for files is changed in NX 9. |
2229649 |
Siemens PLM believes that the problem you reported where alert "Has invalid input feature" is displayed in part navigator after playback operation will be resolved by code changes made to the upcoming release of our software NX 10.0 |
2229718 |
Siemens PLM believes that the problem you reported where running Part Cleanup on Manufacturing objects immediately after saving the part file flags the part as modified will be resolved by code changes made to the upcoming release of our software NX 10. |
2229959 |
Siemens PLM believes that the problem you reported where the initial state of the delay evaluation toggle does not honour the customer default setting, will be resolved by code changes made to the upcoming release of our software NX 10. |
2230016 |
Siemens PLM believes that the problem you reported where positional deviation of the dimension of the JT file will be resolved by code changes made to the upcoming release of our software NX 10. |
2230017 |
Siemens PLM believes that the problem you reported where there is not image of the "intersection" icon for Groups will be resolved by code changes made to the upcoming release of our software NX 10. |
2230022 |
Siemens PLM believes that the problem you reported where Quick Extend does not work correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2230070 |
Siemens PLM believes that the problem you reported where there is not image of the "Load" and "Open" will be resolved by code changes made to the upcoming release of our software NX 10. |
2230121 |
Siemens PLM believes that the problem you reported where the placed Cut Elbow is not added in the active Run will be resolved by code changes made to the upcoming release of our software NX 10. |
2230249 |
Siemens PLM believes that the problem you reported where user cannot edit the Object Display of Weld Feature will be resolved by code changes made to the upcoming release of our software NX 10. |
2230255 |
Siemens PLM believes that the problem you reported where the Group name of laminate garbled will be resolved by code changes made to the release of our product NX version 10. Groups created during inflation now have a non-translated English name. |
2230256 |
Siemens PLM believes that the problem you reported where Synchronous Modeling usability regressed, will be resolved by code changes made to the upcoming release of our software NX 10. |
2230339 |
Siemens PLM believes that the problem you reported where "Layer Filter is invalid for Dimension command in drafting" will be resolved by code changes made to the upcoming release of our software NX 10. |
2230371 |
Siemens PLM believes that the problem you reported where the Find Component dialog did not correctly display multi-byte characters for the displayed name of a component where this would be expected (e.g. in managed mode in the item name, or in non-managed mode where the part display name is an attribute whose value contains multi-byte characters) will be resolved by code changes made to the upcoming release of our software NX 10. |
2230509 |
Siemens PLM believes that the problem you reported where Check Mate test "Report Solid Body with Default Density Setting" wrongly detects the sheet body will be resolved by code changes made to the upcoming release of our software NX 10. Check Mate test "Report Solid Body with Default Density Setting" now has a parameter to let the user optionally exclude the sheet body objects. This problem is fixed in release NX 10. |
2230593 |
Siemens PLM believes that the problem you reported where connected spline path does not move associatively with parent curve will be resolved by code changes made to the upcoming release of our software NX 10. |
2230630 |
Siemens PLM believes that the problem you reported where graph for Contact Pressure is not created with Post View will be resolved by code changes made to the upcoming release of our software NX 10. |
2230671 |
Siemens PLM believes that the problem you reported where Find Component did not expand the assembly structure to a selected component in managed mode where the first Assembly Navigator column is a custom mapped attribute will be resolved by code changes made to the upcoming release of our software NX 10. |
2230678 |
Siemens PLM believes that the problem you reported where "Parts List is not automatically updated when open assembly drawing" will be resolved by code changes made to the upcoming release of our software NX 10. |
2230733 |
Siemens PLM believes that the problem you reported where Hidden lines are not display will be resolved by code changes made to the upcoming release of our software NX 10. |
2230735 |
Don't updates that out-of-date parent "Shared body" part modules. |
2230742 |
Siemens PLM believes that the problem you reported where Customer Default setting "Check In Parts on" is missing in NX in manage mode will be resolved by code changes made to the upcoming release of our software NX 10. |
2230751 |
Results are different while updating the part modules after delayed update. |
2230892 |
Siemens PLM believes that the problem you reported where the stepover moves will be retained when using Divide By Holder on operations where Ramp On Part is used to connect levels will be resolved by code changes made to the upcoming release of our software NX 10. |
2230931 |
Siemens PLM believes that the problem you reported where the result of axisymmetric structural analysis of NX 8.5.2 was fixed in NX 9 and right now there is no plan to backport it to NX 8.5.2. |
2230948 |
Siemens PLM believes that the problem you reported where"Shortest tool length reports wrong value in NX9" will be resolved by code changes made to the upcoming release of our software NX 10. |
2230972 |
Siemens PLM believes that the problem you reported where the error occurs in the selection of the target mesh control will be resolved by code changes made to the upcoming release of our software NX 100 |
2230978 |
Siemens PLM believes that the problem you reported where the error element of 3D mesh was not highlighted will be resolved by code changes made to the upcoming release of our software NX 10. |
2231048 |
Siemens PLM believes that the problem you reported where the problem which can select ""New Assembly FEM" in the Design Simulation. will be resolved by code changes made to the upcoming release of our software NX 10. |
2231065 |
Siemens PLM believes that the problem you reported where 'If Afu file created by "Save As AFU" is opened, an internal error occurs' will be resolved by code changes made to the upcoming release of our software NX 10. |
2231095 |
Siemens PLM believes that the problem you reported where "A read-only part is modified" message from unmodified part will be resolved by code changes made to the upcoming release of our software NX 10. |
2231107 |
Siemens PLM believes that the problem you reported where "Drawing displays as "out-of-date" When open component" will be resolved by code changes made to the upcoming release of our software NX 10. |
2231142 |
Siemens PLM believes that the problem you reported where user cannot open the visual report which defined the name in 2 byte characters will be resolved by code changes made to the upcoming release of our software NX 10. |
2231162 |
Siemens PLM believes that the problem you reported where The characters of 'Visual Reporting' toolbar are garbled in Japanese NX will be resolved by code changes made to the upcoming release of our software NX 10. |
2231262 |
Siemens PLM believes that the problem you reported where user can't change color, Line Font or Width of copy paste curves will be resolved by code changes made to the upcoming release of our software NX 10. |
2231274 |
Siemens PLM believes that the problem you reported where "Slow to react the switching of check boxes in HoleCallout/HoleTable settings" will be resolved by code changes made to the upcoming release of our software NX 10. |
2231303 |
Siemens PLM believes that the problem you reported where "Cannot create the "new sketch group " in traditional Chinese NX" will be resolved by code changes made to the upcoming release of our software NX 10. |
2231320 |
Siemens PLM believes that the problem you reported where CGMImporter imports the CGM file into drafting sheet will be resolved by code changes made to the upcoming release of our software NX 10. |
2231376 |
Siemens PLM believes that the problem you reported where Trim to Parent Duct doesn't work if parent duct is created by Stock Transition will be resolved by code changes made to the upcoming release of our software NX 10. |
2231429 |
Siemens PLM believes that the problem where the .NET Framework version needs to be updated is fixed in release NX 10 documentation. |
2231516 |
Siemens PLM believes that the problem you reported where sketch is not internalized in extrude automatically inside feature group will be resolved by code changes made to the upcoming release of our software NX 10. |
2231605 |
Siemens PLM believes that the problem you reported where 'Problem of View Label in I-deas data with CMM' will be resolved by code changes made to the upcoming release of our software NX 10. |
2231619 |
Siemens PLM believes that the problem you reported where the fatal error on model check for zero-valued closed gap stiffness will be resolved by code changes made to the upcoming release of our software NX 10. |
2231626 |
Siemens PLM believes that the problem you reported where NX cannot return from [point] dialog during [contact mesh] creation will be resolved by code changes made to the upcoming release of our software NX 10. |
2231646 |
Siemens PLM believes that the problem you reported where arrangement information not translated to JT correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2231654 |
Siemens PLM believes that the problem you reported where the filter doesn't function correctly in the "modelling objet manager" dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
2231656 |
Siemens PLM believes that the problem you reported where there are incorrect Japanese characters in the "Fine Track" dialog box will be resolved by code changes made to the upcoming release of our software NX 10. |
2231706 |
Siemens PLM believes that the problem you reported where the user was unable to select face & edge in "Move Node" dialog box will be resolved by code changes made to the upcoming release of our software NX 10. |
2231719 |
Siemens PLM believes that the problem you reported where Assign corner bend does not trim a stock if a Screw seat is placed on the stock will be resolved by code changes made to the upcoming release of our software NX 10. |
2231725 |
Siemens PLM believes that the problem you reported where break corner cannot be created to the edge of normal cutout will be resolved by code changes made to the upcoming release of our software NX 10. The fix provided is a version fix, so it will work for normal cutout features created in NX 10 and above versions. |
2231728 |
Siemens PLM believes that the problem you reported where sketch is not internalized in extrude automatically inside feature group will be resolved by code changes made to the upcoming release of our software NX 10. |
2231750 |
Siemens PLM believes that the problem you reported where the unavailability of stress result for the plane stress/strain element of SOL601 will be resolved by code changes made to the upcoming release of our software NX 10. |
2231759 |
Siemens PLM believes that the problem you reported where "Valid radius range" value for S-bend is incorrect in Assign corner dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
2231765 |
Siemens PLM believes that the problem you reported where "Visible Only" object are selected wrongly when 'Layer Settings' dialog is up is fixed in NX 10.0 documentation. The explanation now reads: "Highlights the layer on which the object resides. You can select any visible object, including the objects on the layers that are visible but not selectable." |
2231983 |
Siemens PLM believes that the problem you reported where when 2 byte character is entered, the 2 byte character is changed in the product interface name column will be resolved by code changes made to the upcoming release of our software NX 10. |
2231984 |
Siemens PLM believes that the problem you reported where Japanese, Chinese and English characters are mixed wrongly in "Visualization Preferences" dialog in Japanese Environment of NX will be resolved by code changes made to the upcoming release of our software NX 10. |
2231985 |
Siemens PLM believes that The problem where bounding boxes are displayed for lightweight assemblies even though the display object boxes until loaded option in the Visualization Performance preferences is OFF will be resolved by code changes made to the upcoming release of our software NX 10. |
2232023 |
Siemens PLM believes that the problem you reported where there is no pyramid element in the mesh view will be resolved by code changes made to the upcoming release of our software NX 10.0 |
2232056 |
Siemens PLM believes that the problem you reported where getting message "Could not get input entity's class" while using ugtopv will be resolved by code changes made to the release of our product NX 10. |
2232139 |
Siemens PLM believes that the problem you reported where some lines in the wire frame body were missing from display after split body operation will be resolved by code changes made to the upcoming release of our software NX 10. |
2232154 |
Siemens PLM believes that the problem you reported where UF_ATTR_set_user_attribute_locks() fails to unlock user attributes will be resolved by code changes made to the upcoming release of our software NX 10. |
2232173 |
Siemens PLM believes that the problem you reported where rectangle Selection does not work correctly against Datum Csys in component when "Datum" is selected in Type Filter will be resolved by code changes made to the release of our product NX version 10. |
2232174 |
Siemens PLM believes that the problem you reported where 'Detail Filtering' button is grayed out after selecting a type which has no data will be resolved by code changes made to the release of our product NX version 10. |
2232196 |
Siemens PLM believes that the problem you reported where offset curve in face operation outputs wrong results will be resolved by code changes made to the upcoming release of our software NX 10. |
2232214 |
Siemens PLM believes that the problem you reported where UF_ATTR_set_user_attribute_lock_with_title_and_type fails to unlock user attributes will be resolved by code changes made to the upcoming release of our software NX 10 |
2232323 |
Siemens PLM believes that the problem you reported where the handle of transformed component is not displayed at the center of the solid will be resolved by code changes made to the upcoming release of our software NX 10. |
2232391 |
Siemens PLM believes that the problem you reported where smashed symbol geometry from Custom Symbols library lie on different planes will be resolved by code changes made to the upcoming release of our software NX 10. |
2232392 |
Siemens PLM believes that the problem you reported where drawing view does not update correctly after changing the reference set to flat solid on a drafting component will be resolved by code changes made to the upcoming release of our software NX 10. |
2232409 |
Siemens PLM believes that the problem you reported where DXF translator is not able to connect to Teamcenter in 4-tier mode will be resolved by code changes made to the upcoming release of our software NX 10. |
2232417 |
Siemens PLM believes that the problem you reported where Show Dimension(Annotation) is off after canceling 'Projected Distance', will be resolved by code changes made to the upcoming release of our software NX 10. |
2232517 |
Siemens PLM believes that the problem you reported where "View Alignment can't work properly if used "model point" or "Point to Point" will be resolved by code changes made to the upcoming release of our software NX 10. |
2232568 |
Siemens PLM believes that the problem you reported where few surface coat elements disappeared after deleting 3D solid mesh will be resolved by code changes made to the upcoming release of our software NX 10. |
2232590 |
Siemens PLM believes that the problem you reported where "Mechanical Routing: Bill of material cant update correctly when edit stock" will be resolved by code changes made to the upcoming release of our software NX 10. |
2232613 |
Siemens PLM believes that the problem you reported where Shading is not displayed in PDF exporting detail view, will be resolved by code changes made to the release of our product NX version 10. |
2232648 |
Siemens PLM believes that the problem you reported where # # 397NONE" is displayed in the column as "Viscoelasticity" and "creep" will be resolved by code changes made to the upcoming release of our software NX 10. |
2232652 |
Siemens PLM believes that the problem you reported where opening top assembly file with structure only takes longer time is resolved in NX8.5 and NX9.0, where NX performance is faster. |
2232764 |
Siemens PLM believes that the problem you reported where "A setup of Narrow is not reflected when creating a chain dimension" will be resolved by code changes made to the documentation of our product NX version 10. |
2232774 |
Siemens PLM believes that the problem you reported where 'The arrangement position of Datum Feature Symbol is changed' will be resolved by code changes made to the release of our product version NX 10. |
2232777 |
Siemens PLM believes that the problem you reported where The "Position Relative to Geometry" option of table command does not work will be resolved by code changes made to the upcoming release of our software NX 10. |
2232796 |
Siemens PLM believes that the problem you reported where thickness of Midsurface on fillet zone will be resolved by code changes made to the upcoming release of our software NX 10. |
2232839 |
Siemens PLM believes that the problem you reported where the working speed of 3d tet mesh is slow if FEM in work part on comparing to the displayed part will be resolved by code changes made to the upcoming release of our software NX 10. |
2232973 |
Siemens PLM believes that the problem you reported where user cannot create the right shell will be resolved by code changes made to the upcoming release of our software NX 10. |
2232989 |
Siemens PLM believes that the problem you reported where the broken Bend RCP is missing in NX8.5.3MP1HF will be resolved by code changes made to the upcoming release of our software NX9.0.2, NX 10, and a HF of NX 8.5.3 MP1 |
2233036 |
Siemens PLM believes that the problem you reported where symbols display of constraint condition disappear will be resolved by code changes made to the upcoming release of our software NX 10. |
2233078 |
Siemens PLM believes that the problem you reported where copied csys have different scale factor than that of original, will be resolved by code changes made to the upcoming release of our software NX 10. |
2233117 |
Siemens PLM believes that the problem you reported where "About the Arrowhead option of Narrow node" will be resolved by changes made to the documentation of our product NX version 10. |
2233122 |
Siemens PLM believes that the problem you reported where " External thread is garbled in Revolved Section View" will be resolved by code changes made to the release of our product NX version NX 10. |
2233323 |
Siemens PLM believes that the problem you reported where difference in work layer after finishing the sketch for interactive & by execution of journal code will be resolved by code changes made to the upcoming release of our software NX 10. |
2233349 |
Velocity is displayed wrong in PTS dialog box. |
2233365 |
Trace selects two bodies but PTS Motion trace selects only one body wrongly. |
2233461 |
Siemens PLM believes that the problem you reported where Width of the navigator is not kept after changing the application/task will be resolved by code changes made to the upcoming release of our software NX 10. |
2233681 |
The problem where "Custom Symbol" is not displayed even when the Layer is made selectable has been investigated and the following has been found. This is working as designed. Symbol definition does not entertain invisible objects both in edit and create. The following note was added to the overview information for both the Define Custom Symbol and Edit Custom Symbol commands: "Only visible objects are used to define a master custom symbol. While creating or editing a master custom symbol, if objects are on an invisible layer, or are hidden, they will not be added to the master custom symbol definition." |
2233691 |
The problem where The number of objects selected differs depending upon the zoom in /out has been fixed in NX 10. This is a designed behavior. In NX 10 documentation this behavior has been explained. |
2233703 |
Siemens PLM believes that the problem you reported where user cannot enter the multi byte character in Home Page URL will be resolved by code changes made to the release of our product NX 10. |
2233720 |
Siemens PLM believes that the problem you reported where an edge which is not intended is created while creating face blend will be resolved by code changes made to the upcoming release of our software NX 10. |
2233759 |
Siemens PLM believes that the problem you reported where the problem idealize body is not recognized as child of a promoted body will be resolved by code changes made to the upcoming release of our software NX 10. |
2233793 |
Siemens PLM believes that the problem you reported where Save As is executed, non-master is copied will be resolved by code changes made to the upcoming release of our software NX 10. |
2233811 |
Siemens PLM believes that the problem you reported where setTaggedObjectVector does not clear all object in Specify Vector block will be resolved by code changes made to the upcoming release of our software NX 10. |
2233829 |
Siemens PLM believes that the problem you reported where Attempt to save bad pointer, save aborted when saving a drawing will be resolved by code changes made to the release of our product NX version 10. |
2233837 |
Siemens PLM believes that the problem you reported where color map of deviation gauge does not show correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2233861 |
Siemens PLM believes that the problem you reported where unit conversion is wrong for centrifugal pressure on export simulation will be resolved by code changes made to the release of our product NX version 10. |
2233866 |
Siemens PLM believes that the problem you reported where Color of bodies doesn't change even if the collision occurs will be resolved by code changes made to the upcoming release of our software NX 10. |
2234160 |
Siemens PLM believes that the problem you reported where Loading UTD file increases CPU utilization of "ugraf.exe" will be resolved in the upcoming release of NX 10. |
2234224 |
Siemens PLM believes that the problem you reported where Form board cannot be created with "Unknown Error in Routing" message will be resolved by code changes made to the release of our product NX 10. |
2234305 |
Siemens PLM believes that the problem you reported where arrow point position is changed after Note with Leader is copied to Layer will be resolved by code changes made to the upcoming release of our software NX 10. |
2234315 |
Siemens PLM believes that the problem you reported where Chinese characters in drafting annotation not display correctly will be resolved by code changes made to the release of our product NX version 10. |
2234328 |
Siemens PLM believes that the problem you reported where Error in Multiple Selection of Parts through "File Selection with browse" block will be resolved by code changes made to the upcoming release of our software NX 10. |
2234379 |
Siemens PLM believes that the problem you reported where UF_MODL_ask_object_feat doesn't work as previous versions in NX8.5.3 will be resolved by code changes made to the upcoming release of our software NX 10. |
2234490 |
Siemens PLM believes that the problem you reported where "Inconsistency in isometric view when processed Hidden Lines" will be resolved by changes made to documentation of our product NX version 10. |
2234527 |
Siemens PLM believes that the problem you reported where "Specify Location is NOT automatically enabled when set Hinge in NX 9" will be resolved by code changes made to the upcoming release of our software NX 10. |
2234642 |
Siemens PLM believes that the problem you reported where the processing time of [Move Part] is extremely slow in NX 9 will be resolved by code changes made to the upcoming release of our software NX 10. |
2234652 |
Siemens PLM believes that the problem you reported where only a portion of the translated part was ending up in the CATPart file will be resolved by code changes made to the upcoming release of our software NX 10. |
2234687 |
Siemens PLM believes that the problem you reported where solid body is getting exported when a drawing is exported will be resolved by code changes made to the upcoming release of our software NX 10. |
2234699 |
Text Justification of weld symbol does not function. |
2234757 |
Siemens PLM believes that the problem you reported where "User Defined Text" was wrongly written in Nastran input deck on using "merged" option will be resolved by code changes made to the upcoming release of our software NX 10. |
2234802 |
Siemens PLM believes that the problem you reported where "Display style of Datum Feature Symbol is not retained after edit." will be resolved by code changes made to the release of our product NX version NX 10. |
2234805 |
Siemens PLM believes that the problem you reported where the direction of the bias is reversed will be resolved by code changes made to the upcoming release of our software NX 10. |
2234828 |
Siemens PLM believes that the problem you reported where CreateSectionViewBuilder() NXOpen API was giving message "Not Yet Implemented" will be resolved by code changes made to the upcoming release of our software NX 10. |
2234852 |
Siemens PLM believes that the problem you reported where Edges cannot be selected using multi-select if the representation is lightweight will be resolved by code changes made to the upcoming release of our software NX 10. |
2235120 |
Siemens PLM believes that the problem you reported where line was created associative but still line was not following views move will be resolved by code changes made to the upcoming release of our software NX 10. |
2235197 |
Siemens PLM believes that the problem you reported where "Unable to edit a section line when using [Edit Section Line]" will be resolved by code changes made to the upcoming release of our software NX 10. |
2235280 |
Siemens PLM believes that the problem you reported where Docs of NXOpen>Section>AddToSection() needs to be updated has been updated in NX 10 documentation. Regarding the documentation of Chaining Tolerance, the statement suggested in PR Text is always not true. As ChainingTolerance is an API property, User can set it to any value (not necessarily 95% of distance tolerance) in his journaled program. However it is recommended to have chaining tolerance slightly tighter than distance tolerance. |
2235286 |
Siemens PLM believes that the problem you reported where Wire Tool is not displayed and the error occurs with Teamcenter will be resolved by code changes made to the upcoming release of our software P10 phase 19. |
2235323 |
Siemens PLM believes that the problem you reported where we cannot de-select the face in Analysis - Shape operations will be resolved by code changes made to the upcoming release of our software NX 10. |
2235510 |
Siemens PLM believes that the problem you reported where geometric constraints of sketch are unable to display will be resolved by code changes made to the upcoming release of our software NX 10.0 Note that doing an invert will not show the constraints of an inactive sketch. The user must activate the sketch to unblank the constraints in them. |
2235532 |
Siemens PLM believes that the problem you reported where in edit suppression state, the state column is not displaying the correct status of components is designed. The information will be added to NX 10 documentation. |
2235560 |
Siemens PLM believes that the problem you reported where NX freezes when performed the Offset Face will be resolved by code changes made to the upcoming release of our software NX 10. |
2235572 |
Siemens PLM believes that the problem you reported where 'Interpart Expression' does not display correctly in Spreadsheet will be resolved by code changes made to the upcoming release of our software NX 10. In NX 10 we have redesigned IPEs for MFK. We no longer export/import IPEs in NX 10 since we no longer have a textual representation for file names that is human readable. So instead of x=A::y you will have x=p1 where p1=interpart0 where interpart0 is a named reference for the IPE just like we do for measurements and attributes - we don't export them either. The problem where Interpart Expression does not display correctly in spreadsheet is not seen in NX 10 since the way we show IPE is changed now in NX 10. |
2235578 |
Siemens PLM believes that the problem you reported where highlight of the edge is not removed even on cancelling "split edge" will be resolved by code changes made to the upcoming release of our software NX 10. |
2235615 |
Siemens PLM believes that the problem you reported where the center of snap point does not work with 1D connection will be resolved by code changes made to the upcoming release of our software NX 10. |
2235665 |
The problem where "Getting message "Could not get input entity's class" while using ugtopv" is fixed in release NX 10. |
2235668 |
Siemens PLM believes that the problem you reported where, Export to step214 gives error "out of windows GDI objects" will be resolved by code changes made to the upcoming release of our software NX 10. |
2235689 |
Siemens PLM believes that the problem you reported where geometric Constraints of the sketch are not displayed will be resolved by code changes made to the upcoming release of our software NX 10. |
2235722 |
Siemens PLM believes that the problem you reported where an ambiguous message is raised when the user creating a PDF will be resolved by code changes made to the upcoming release of our software NX 10. |
2235731 |
Siemens PLM believes that the problem you reported where "The behavior of "Character scale factor menu" is not right in NX 8.5.3" will be resolved by code changes made to the upcoming release of our software NX 10. |
2235766 |
Siemens PLM believes that the problem you reported where toolbar did not appear while clicking "Show Toolbar" in Menu -> Assemblies -> Exploded View will be resolved by code changes made to the upcoming release of our software NX 10.As a fix to this issue, "Show Toolbar" option will not be available in Ribbon Layout and will only be available in Classic Layout. Note: Below are some suggestions to make the "Exploded Views" commands more accessible in Ribbon Layout. 1. It can be set to be always un-collapsed in the assemblies tab. To do this in the assemblies tab MB3 on the "Exploded Views" group, then select customize. Then with the customize dialog open, MB3 on the exploded views group again and uncheck collapsed. (To collapse it again, with the customize dialog open, MB3 on the small arrow that represents more on the right bottom of the exploded views group again and check collapsed. 2. One can create their own new tab. To do this, MB3 on an unused part on the Ribbon Bar, select customize. Then select Tabs/Bars tab and click "New" button. Then put the exploded views commands on it. |
2235783 |
Siemens PLM believes that the problem you reported where NX Open (NX 9 Open Wizard) wizard throws compilation error will be resolved by code changes made to the upcoming release of our software NX 10. |
2235828 |
Siemens PLM believes that the problem you reported where the user can not create Graph of Reaction Force-Nodal will be resolved by code changes made to the upcoming release of our software NX 10. |
2235882 |
Siemens PLM believes that the problem you reported where Automatic Sorting Orders incorrectly works in NX 9 Japanese mode will be resolved by documentation changes made to the upcoming release of our software NX 10.The sort method example table at question in this Help topic is redundant and confusing and not needed to understand the preceding text for Sort Method options. In fact, the example over complicates what is basically a list of simple concepts. The example sort method has therefore been removed from the "Sorting model views" help topic. |
2235962 |
Siemens PLM believes that the problem you reported where "Exact" & "Exact(Pre-NX 8.5)" Behavior is differences in the view representation will be resolved by code changes made to the release of our product NX version NX 10. |
2236009 |
Siemens PLM believes that the problem you reported where NX freezes on 2D local remesh" will be resolved by code changes made to the upcoming release of our software NX 10. |
2236052 |
Siemens PLM believes that the problem you reported where "Leader Line of GD&T can't display correctly NX9" will be resolved by code changes made to the upcoming release of our software NX 10. |
2236062 |
Siemens PLM believes that the problem you reported where extrude changes will be resolved by code changes made to the upcoming release of our software NX 10. |
2236063 |
Siemens PLM believes that the problem you reported where UFUgmgr.SavePreciseAssembly() terminates NX session will be resolved by code changes made to the release of our product NX 10. |
2236107 |
Siemens PLM believes that the problem you reported where bad size for allocation request in storage manager error occurs while importing PTS data will be resolved by code changes made to the upcoming release of our software NX 10. |
2236140 |
Siemens PLM believes that the problem you reported where Information message inPopulate Title Block Dialog is not displayed in Japanese will be resolved by code changes made to the upcoming release of our software NX 10. |
2236154 |
Siemens PLM believes that the problem you reported where teh problem of "Unique DOF values" of "Manual Coupling" will be resolved by code changes made to the upcoming release of our software NX 10. |
2236189 |
Siemens PLM believes that the problem you reported where the color setup of overflow is not outputted to JT file will be resolved by code changes made to the release of our software NX 10. |
2236242 |
Siemens PLM believes that the problem you reported where the model file cannot be closed with an error in drafting application will be resolved by code changes made to the upcoming release of our software NX 9.0.3,NX 10 |
2236249 |
Siemens PLM believes that the problem you reported where editing the arrow head style causes unexpected addition of stub in Datum feature will be resolved by code changes made to the upcoming release of our software NX 10. |
2236251 |
Siemens PLM believes that the problem you reported where The %ui_comp OnInitialize callback is not invoked for a child rule of the class %ui_comp_types will be resolved by code changes made to the release of our software NX 10. |
2236262 |
Siemens PLM believes that the problem you reported where "Leader Line of GD&T symbol is not displayed correctly in NX9" will be resolved by code changes made to the upcoming release of our software NX 10. |
2236266 |
Siemens PLM believes that the problem you reported where the component name differs when a part is placed again by selecting it from ANT will be resolved by code changes made to the upcoming release of our software NX 10. |
2236267 |
Siemens PLM believes that the problem you reported where "Section Line looks incorrect when open drawing in NX 9" will be resolved by code changes made to the upcoming release of our software NX 10. |
2236354 |
Not apply the input name for seed set name when we select OK in the dialog. |
2236364 |
Siemens PLM believes that the problem you reported where "can not import drawing" will be resolved by code changes made to the upcoming release of our software NX 10. |
2236519 |
Siemens PLM believes that the problem you reported where Inherited PMI dimension value is not updated will be resolved by code changes made to the upcoming release of our software NX 10. |
2236655 |
Siemens PLM believes that the problem you reported where "A view label letter cannot be changed into an unused letter" will be resolved by code changes made to the release of our product NX version NX 10. |
2236703 |
Siemens PLM believes that the problem you reported where stress wizard is not displaying Safety factor results will be resolved by code changes made to the release of our product NX 10.0 |
2236731 |
Read-only Part message is displayed when select custom symbol. |
2236770 |
Siemens PLM believes that the problem you reported where Y-axis does not remain still when rotating view about Y-axis using slider will be resolved by code changes made to the upcoming release of our software NX 10. |
2236803 |
Siemens PLM believes that the problem you reported where [Define Deformable Part] disappear after switching to Routing will be resolved by code changes made to the upcoming release of our software NX 10. |
2236951 |
Siemens PLM believes that the problem you reported where "Unused Items disappear in Drafting Application when delete Group" will be resolved by code changes made to the upcoming release of our software NX 10. |
2237088 |
Siemens PLM believes that the problem you reported where Macro cannot be playback will be resolved by code changes made to the upcoming release of our software NX 10. |
2237112 |
Siemens PLM believes that the problem you reported where a cylindrical dimension to silhouettes of a swept surface does not update correctly will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 10. |
2237131 |
Siemens PLM believes that the problem you reported where Fatigue Safety Factor is high in the setting part of a constraint and load will be resolved by code changes made to the upcoming release of our software NX 10. |
2237141 |
Siemens PLM believes that the problem you reported where an error is Displayed when Sketch is edited will be resolved by code changes made to the upcoming release of our software NX 10.For the given example, the problem happens because there is a bad dimension in the sketch. We have fixed the part file by deleting the bad dimension and fixed part file is uploaded to PR data. In NX 10, we have made the code tolerant to this error, so the error will not happen on playback, but the user still needs to use the fixed part in NX 10 to avoid any future issues with the bad dimension. |
2237232 |
Siemens PLM believes that the problem you reported where Strange virtual intersection curve is created in NX8.5 will be resolved by code changes made to the upcoming release of our software NX 10. |
2237235 |
Siemens PLM believes that the problem you reported where surface finish symbol units are different in Drafting and Modelling PMI will be resolved by code changes made to the upcoming release of our software NX 10. |
2237253 |
Siemens PLM believes that the problem you reported where [Face Blend] fails in NX 9.01 on a specific data will be resolved by code changes made to the release of our product NX version 10. |
2237260 |
Siemens PLM believes that the problem you reported where Update All Feature issue will be resolved by code changes made to the release of our product NX version 10. |
2237267 |
Siemens PLM believes that the problem you reported where unable to reference parent objects that are suppressed will be resolved by code changes made to the upcoming release of our software NX 10. |
2237273 |
Siemens PLM believes that the problem you reported where the file name of exported spreadsheet is wrong will be resolved by code changes made to the release of our product NX version 10. |
2237275 |
Siemens PLM believes that the problem you reported where drawing parts cannot be opened with wireframe color source set to From Face will be resolved by code changes made to the upcoming release of our software NX9.0.3 and NX 10. |
2237309 |
Siemens PLM believes that the problem you reported where the difference in the order of mesh name in that post view will be resolved by code changes made to the upcoming release of our software NX 10. |
2237369 |
Siemens PLM believes that the problem you reported where Cannot select Extracted Edge Line in Drafting will be resolved by code changes made to the upcoming release of our software NX 10. |
2237426 |
Siemens PLM believes that the problem you reported where Bend corners are removed if UGII_ROUTING_FIX_CONVERTED_BEND_CORNERS is set will be resolved by code changes made to the upcoming release of our software NX 10. |
2237452 |
Siemens PLM believes that the problem you reported where when split bodies moved, the associative curve is not updated will be resolved by code changes made to the upcoming release of our software NX 10. |
2237489 |
Siemens PLM believes that the problem you reported where Different Thread method type is set in NX9 will be resolved by code changes made to the upcoming release of our software NX 10. |
2237574 |
Siemens PLM believes that the problem you reported where journal reply fails when multiple bodies are displayed in work part will be resolved by code changes made to the upcoming release of our software NX 10. |
2237578 |
Siemens PLM believes that the problem you reported where there is a large difference in commutation time of response simulation will be resolved by code changes made to the upcoming release of our software NX 10. As a work-around, customers can also set the OIBULK paramater to NO in the solution to stop the outputting of this additional information. This will return the evaluation performance to the NX 8 level. |
2237599 |
Siemens PLM believes that the problem you reported where "Front" and "Back" of the New Layout dialog were not translated into the local language will be resolved by code changes made to the release of our product NX version 10. |
2237605 |
Siemens PLM believes that the problem you reported where the weld mesh cannot created will be resolved by code changes made to the upcoming release of our software NX 10. |
2237708 |
Siemens PLM believes that the problem you reported about Graphs from Post and Multiple Reduction will be resolved by code changes made to the upcoming release of our software NX 10. |
2237714 |
Siemens PLM believes that the problem you reported where "layer filters do not works in "view dependent edit"" will be resolved by code changes made to the upcoming release of our software NX 9 and NX 10. |
2237719 |
"View -> Tool Bar" does not work in Japanese language. |
2237840 |
Disconnected tool path is generated in NX 8.5.3MP3 |
2237896 |
Siemens PLM believes that the problem you reported where the node coordinates are different for the average of the element stress will be resolved by code changes made to the upcoming release of our software NX 10. |
2237935 |
Siemens PLM believes that the problem you reported where the number of sheets changes automatically when you use the Orient View Tool will be resolved by code changes made to the release of our product NX version 10. |
2238031 |
Siemens PLM believes that the problem you reported where part file name and component name do not become the same name will be resolved by code changes made to the upcoming release of our software NX 10. |
2238034 |
Siemens PLM believes that the problem you reported where "In NX 8.5.3.3 MP3 The new Line Thickness mapping does not work on dimensions" will be resolved by code changes made to the release of our product NX version NX 10. |
2238167 |
Siemens PLM believes that the problem you reported where Unsuitable OM class error occurs when use Move Object, will be resolved by code changes made to the upcoming release of our software NX 10.0 |
2238190 |
Siemens PLM believes that the problem you reported where Internal Error occurred in updating Sketch will be resolved by code changes made to the upcoming release of our software NX 10.The problem happens because there is a bad dimension in the sketch. We have fixed the part file by deleting the bad dimension and fixed part file is uploaded to PR data. In NX 10, we have made the code tolerant to this error. So the error will not happen on playback. But the user still needs to use the fixed part in NX 10 to avoid any future issues with the bad dimension. |
2238276 |
Siemens PLM believes that the problem you reported where the Japanese translation is different in "Graph Window" will be resolved by code changes made to the upcoming release of our software NX 10.The translation of "Export Template" has been corrected in NX 10. |
2238289 |
Siemens PLM believes that the problem you reported where "Update error occurs in Tab" will be resolved by code changes made to the release of our software NX 10. |
2238398 |
Siemens PLM believes that the problem you reported where "Update error occurs in Delete Face" will be resolved by code changes made to the release of our product NX 10. |
2238410 |
Siemens PLM believes that the problem you reported where "Update error in Delete Face" will be resolved by code changes made to the release of our product NX 10. |
2238428 |
Siemens PLM believes that the problem you reported where can not do "Save All" if change the name of the mesh collector will be resolved by code changes made to the upcoming release of our software NX 10. |
2238432 |
Siemens PLM believes that the problem you reported where dialog of Synchronous Modeling is mistranslated in Japanese NX will be resolved by code changes made to the upcoming release of our software NX 10. |
2238481 |
Siemens PLM believes that the problem you reported where NX stops responding when run analysis of Pedestrian Protection will be resolved by code changes made to the upcoming release of our software NX 10. However the data used will not produce very realistic results. It was not really large enough to produce data as expected. We modified the data that shows reasonable results for Pedestrian Protection. The data can be made available upon request. |
2238495 |
Siemens PLM believes that the problem you reported where Remove Parameters error "A deleted or invalid class id was used" will be resolved by code changes made to the upcoming release of our software NX 10. |
2238539 |
Siemens PLM believes that the problem you reported where rectangle Selection does not work correctly against Datum Csys in component when "Datum" is selected in Type Filter will be resolved by code changes made to the release of our product NX version 10. |
2238603 |
Siemens PLM believes that the problem you reported where Lightweigth Body disappears from Layer Settings after save will be resolved by code changes made to the release of our product NX version 10. |
2238648 |
Siemens PLM believes that the problem you reported where "Hole table report the insistent hole dia" will be resolved by code changes made to the upcoming release of our software NX 10. |
2238653 |
Siemens PLM believes that the problem you reported where "Creating a section view in a specific way, the section view tilts" will be resolved by code changes made to the upcoming release of our software NX 10. |
2238690 |
CPJ-VUP: UAF Failure(NX9.0.2.2) Update warning for Convert To Sheet Metal |
2238803 |
Siemens PLM believes that the problem you reported where Exactly the same checker is not identified in NX 7.5 and NX 9.0 will be resolved by code changes made to the upcoming release of our software NX 10. |
2238815 |
Siemens PLM believes that the problem you reported where NXOpen.Assemblies > ComponentAssembly >OpenComponents() throws an internal error will be resolved by code changes made to the upcoming release of our software NX 10. |
2238833 |
Siemens PLM believes that the problem you reported where Hidden edges shown in the PDF file of the Lightweight view will be resolved by code changes made to the release of our product NX 10. |
2238876 |
Siemens PLM believes that the problem you reported where minimum distance measurement value is not updated correctly will be resolved by code changes made to the upcoming release of our software NX 10.0 Need to create new measure feature in order to get it update correctly. |
2238923 |
Siemens PLM believes that the problem you reported where Layer Category View control in PTS does not work properly will be resolved by code changes made to the upcoming release of our software NX 10. |
2239135 |
Siemens PLM believes that the problem you reported where UG NAME gets changed during clone operation will be resolved by code changes made to the upcoming release of our software NX 10. |
2239151 |
Siemens PLM believes that the problem you reported where when component is moved, 'internal error: memory access violation error' occurs will be resolved by code changes made to the upcoming release of our software NX 10. |
2239203 |
Siemens PLM believes that the problem you reported where Description of option "Apply base angle at" in Lower Scrap Cutter is not available in documentation is now added in NX 10. |
2239227 |
Siemens PLM believes that the problem you reported where Connection list cannot be imported if connection navigator is undocked once will be resolved by code changes made to the upcoming release of our software NX 10. |
2239232 |
Siemens PLM believes that the problem you reported where translation mistake of "Flow Type" will be resolved by code changes made to the release of our product NX version 10. |
2239247 |
Siemens PLM believes that the problem you reported where minimum distance result is not correct will be resolved by code changes made to the upcoming release of our software NX 10. |
2239400 |
Siemens PLM believes that the problem you reported where the problem which cannot change "Complex" of a "Deformation" dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
2239438 |
Siemens PLM believes that the problem you reported where the Creation of idealized part file in a folder with a double-byte character name will be resolved by code changes made to the upcoming release of our software NX 10ph15. |
2239653 |
Siemens PLM believes that the problem where aspect ratio set in Drafting preferences is not correctly inherited by table cells when 'Auto Size Text' fit method is ON will be resolved by code changes made to the upcoming release of our software NX 10. |
2239703 |
Siemens PLM believes that the problem you reported where "NX803 give different volume use measure body and advanced weight management" will be resolved by code changes made to the upcoming release of our software NX 10. |
2239872 |
Siemens PLM believes that the problem you reported where NX dialog does not dismissed correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2239914 |
Siemens PLM believes that the problem you reported where "The Centerline Customer Default settings scope should be display as Session" will be resolved by code changes made to the upcoming release of our software NX 10. |
2239988 |
Siemens PLM believes that the problem you reported where "When selects [Break-out], sketch curve from only one view is visible." will be resolved by code changes made to the upcoming release of our software NX 10. |
2240005 |
Siemens PLM believes that the problem you reported where the description in an error message has an error will be resolved by code changes made to the upcoming release of our software NX 10. The Model Setup Check has been modified to correctly refer to the "File->Export->Simulation" menu item. |
2240013 |
Siemens PLM believes that the problem you reported where GetEntities does not work on feature returned by GeomcopyBuilder will be resolved by code changes made to the upcoming release of our software NX 10. |
2240065 |
Siemens PLM believes that the problem you reported where Item Type for custom symbol is changed after changing display part will be resolved by code changes made to the upcoming release of our software NX 10. |
2240068 |
Siemens PLM believes that the problem you reported where the document page of "Tolerance values" description moved from [CAD - Modeling - Appendices] will be resolved by code changes made to the upcoming release of our software NX 10. We set up reuse links from CAE Advanced Simulation help to Modeling appendices help for both help documents, "How edges are represented in a solid model" and "Tolerance values." |
2240122 |
Siemens PLM believes that the problem you reported where insufficient documentation for UF_MODL_subtract_bodies_with_retained_options () has been updated in NX 10 documentation. |
2240126 |
Siemens PLM believes that the problem you reported where Resultant shape of Convert to sheetmetal differs from earlier versions in NX9 will be resolved by code changes made to the release of our product NX 10. |
2240163 |
Siemens PLM believes that the problem you reported where Displayed names of System Navigator Orders are not shown in user locale will be resolved by code changes made to the release of our product NX version 10. |
2240169 |
Siemens PLM believes that the problem you reported where "Move object: alert displayed if don't have any dim or constraint for curves" will be resolved by code changes made to the upcoming release of our software NX 10. |
2240173 |
Siemens PLM believes that the problem you reported where the missed translation of "DASHED" will be resolved by code changes made to the release of our product NX version 10. |
2240183 |
Siemens PLM believes that the problem you reported where "The false body of bending insert is in wrong direction" will be resolved by code changes made to the upcoming release of our software NX 10. |
2240296 |
Siemens PLM believes that the problem you reported where material properties are not copied using move object, will be resolved by code changes made to the upcoming release of our software NX 10. |
2240363 |
Siemens PLM believes that the problem you reported where "Cannot Edit Custom Symbol Internal Error occurs" will be resolved by code changes made to the upcoming release of our software NX 10. |
2240450 |
Siemens PLM believes that the problem you reported where unable to access the custom line width if the output is changed in print dialog will be resolved by code changes made to the upcoming release of our software NX 10 and NX 9.0.3 |
2240504 |
Siemens PLM believes that the problem you reported where print dialog value of scale factor width is not changed even after changing customer defaults values will be resolved by code changes made to the upcoming release of our software NX 10. |
2240550 |
Siemens PLM believes that the problem you reported where the Japanese text is garbled on output from ug_export will be resolved by code changes made to the upcoming release of our software NX 10. |
2240588 |
Siemens PLM believes that the problem you reported where "Position of [datum feature symbol] shifts." will be resolved by code changes made to the release of our product NX version NX 10. |
2240668 |
Siemens PLM believes that the problem you reported where sing an expression to suppress an annotation causes it to no longer appear as a User Expression, will be resolved by code changes made to the upcoming release of our software NX 10. |
2240724 |
Siemens PLM believes that the problem you reported where when suppressed assembly changed to never suppressed internal error: memory access violation error occurs will be resolved by code changes made to the upcoming release of our software NX 10. |
2240778 |
Siemens PLM believes that the problem you reported where the 'Description' when in 2 byte character, the Layer Category will be broken will be resolved by code changes made to the upcoming release of our software NX 10. |
2240870 |
Siemens PLM believes that the problem you reported where "Total settings not recognized in this release are not displayed in result file" will be resolved by code changes made to the upcoming release of our software NX 10. |
2240901 |
Siemens PLM believes that the problem you reported where "Why have to press "enter" before input the symbol to dimension note in GC toolkit" will be resolved by code changes made to the upcoming release of our software NX 10. |
2240967 |
Siemens PLM believes that the problem you reported where "Curve that has been erased by "View Dependent Edit" will be appear." will be resolved by code changes made to the release of our product NX version 10.0. The following information was added to the View Dependent Edit topic in the Drafting Help collection: "When working with section views, make sure to set or clear the Show Background option for the section view before you make any view dependent edits. If you reset this option, any existing view dependent edits will be lost." |
2240968 |
Siemens PLM believes that the problem you reported where the problem "Highlight display by Examine Geometry in Advanced Sim is strange" will be resolved by code changes made to the upcoming release of our software NX 10. |
2240990 |
Siemens PLM believes that the problem you reported where section segment was not able to be moved, will be resolved by code changes made to the upcoming release of our software NX 10. |
2241000 |
Siemens PLM believes that the problem you reported where the subtract operation result is not correct will be resolved by code changes made to the upcoming release of our software NX 10. |
2241058 |
Siemens PLM believes that the problem you reported where incorrect translation for "Create connection wizard: From Component Properties" will be resolved by code changes made to the upcoming release of our software NX 10. |
2241090 |
Siemens PLM believes that the problem you reported where "Origin Tool dialog box can't reset to their default values" will be resolved by code changes made to the upcoming release of our software NX 10. |
2241100 |
When I set the spacing of edge, Weld Row Density creates a strange mesh. |
2241125 |
Siemens PLM believes that the problem you reported where Non Cutting time popup on Time column becomes 0 after running Tool Path Divide will be resolved by code changes made to the upcoming release of our software P10.0/phase 14. |
2241169 |
Siemens PLM believes that the problem you reported where update error occurs when copy the Solid Body will be resolved by code changes made to the upcoming release of our software NX 10. Please note that NX only supports the copy/paste/rename of the KF function ug_askValueOfExpressionStr(). The KF function ug_askExpressionValue_() is not supported. Hence the user has to change their calls from ug_askExpressionValue_() to ug_askValueOfExpressionStr() |
2241194 |
Siemens PLM believes that the problem you reported where "Drafting dimensions are not updated definitely" will be resolved by code changes made to the upcoming release of our software NX 10. |
2241205 |
Siemens PLM believes that the problem you reported where when simplify assembly is edited, internal error: memory access violation error occurs will be resolved by code changes made to the release of our product NX version 10. |
2241269 |
Siemens PLM believes that the problem you reported where Fail to convert Mechanism data from I-deas in CMM will be resolved by code changes made to the release of our product CMM version 10. |
2241310 |
Siemens PLM believes that the problem you reported where the information of 'geometric constraints' is wrong in Japanese environment will be resolved by code changes made to the release of our product NX version 10.0. The translation of 'Drag and Drop' has been updated in NX 10. |
2241396 |
Siemens PLM believes that the problem you reported where Name of 'to component' step differs from title of dialog in Japanese environment will be resolved by code changes made to the upcoming release of our software NX 10. |
2241399 |
Siemens PLM believes that the problem you reported where 'Edit Character Font', internal error occurs will be resolved by code changes made to the upcoming release of our software NX 10. |
2241413 |
Siemens PLM believes that the problem you reported where '[CAD]Can not create Ordinate dimension' will be resolved by code changes made to the release of our product version NX 10. |
2241434 |
Siemens PLM believes that the problem you reported where uc1616() returns a wrong coordinate value when selection type is intersection point will be resolved by code changes made to the upcoming release of our software NX 10. |
2241539 |
Siemens PLM believes that the problem you reported where "An alert of 'studio spline' is wrong in Japanese environment" will be resolved by code changes made to the upcoming release of our software NX 10 phase16. |
2241555 |
Siemens PLM believes that the problem you reported where Extra bodies translated while exporting the JT file will be resolved by code changes made to the upcoming release of our software NX 9.0.3 & NX 10. |
2241573 |
Enum block not getting updated for style "Radio Box". |
2241575 |
Siemens PLM believes that the problem you reported where "Unitless Scalar" is grayed out when importing csv as spectrum will be resolved by code changes made to the upcoming release of our software NX 10. |
2241596 |
Siemens PLM believes that the problem you reported where Error will be displayed if it changes to "Part Navigator" will be resolved by code changes made to the upcoming release of our software NX 10. |
2241742 |
Siemens PLM believes that the problem you reported where entities erased by View Dependent Edit appear after view update will be resolved by code changes made to the upcoming release of our software NX 10. |
2241782 |
Siemens PLM believes that the problem you reported where Functions disappear in XY function navigator of Japanese GUI for associated AFU will be resolved by code changes made to the upcoming release of our software NX 10. |
2241812 |
Siemens PLM believes that the problem you reported where offset flips when creating double sided offset without dimensions will be resolved by code changes made to the upcoming release of our software NX 10. |
2241848 |
Siemens PLM believes that the problem you reported where 'Back' isn't translated in layout dialog in Japanese environment will be resolved by code changes made to the upcoming release of our software NX 10. |
2241853 |
Siemens PLM believes that the problem you reported where 'Classic toolbars' in customize dialog is wrong in Japanese environment will be resolved by code changes made to the upcoming release of our software NX 10. |
2241893 |
Bridge & Spline Curves are not updated well. |
2241916 |
Siemens PLM believes that the problem you reported where an error is displayed when saving assembly data will be resolved by code changes made to the upcoming release of our software NX 10. |
2241924 |
Siemens PLM believes that the problem you reported where modifying edge density in "2D Mapped Mesh", "Mesh Associated Data" was reset will be resolved by code changes made to the upcoming release of our software NX 10. |
2242004 |
Siemens PLM believes that the problem you reported where If "View Animation Speed" is "Immediate" the "Fit" command doesn't work correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2242012 |
Siemens PLM believes that the problem you reported where DB_PART_NAME value is not updated in Teamcenter will be resolved by code changes made to the upcoming release of our software NX 10. |
2242073 |
Siemens PLM believes that the problem you reported where documentation for "Uniform segments" option in fit curve command is not correct will be resolved by code changes made to the upcoming release of our software NX 10.New text for Uniform Segments box in Fit Curve dialog box options topic: "Specifies that knots are distributed in uniform segments along the fitted spline." |
2242089 |
Internal error occur when result identify output for Excel. |
2242126 |
Siemens PLM believes that the problem you reported where the problem with editing an MCS that references a vector that is normal to a face at a point will be resolved by code changes made to the upcoming release of our software NX 10. |
2242165 |
Siemens PLM believes that the problem you reported where stitchedge function cause NX crash will be resolved by code changes made to the upcoming release of our software NX 10. |
2242176 |
Siemens PLM believes that the problem you reported where "If we copy "ID symbol" in "Move Object: Value of the Spacing Factor is changed." will be resolved by code changes made to the release of our product NX version NX 10. |
2242194 |
Siemens PLM believes that the problem you reported where the Display does not follow the change of the diameter of the bar element will be resolved by code changes made to the upcoming release of our software NX 10 IP16. |
2242198 |
Siemens PLM believes that the problem you reported where saving an assembly with unloaded suppressed components could result in an error in some cases will be resolved by code changes made to the upcoming release of our software NX 10. |
2242285 |
Siemens PLM believes that the problem you reported where importing CGM file in NX shows different result i.e. 'ellipse shape changed into hexagonal shape' will be resolved by code changes made to the upcoming release of our software NX 10. |
2242328 |
Siemens PLM believes that the problem you reported where UF_DRF_ask_label_info() returns incorrect PMI text values in the Japanese locale will be resolved by code changes made to the upcoming release of our software NX 10. |
2242329 |
Siemens PLM believes that the problem you reported where the position of datum is changed by CreateDraftingDatumFeatureSymbolBuilder will be resolved by code changes made to the release of our product NX 10. However even after this fix there will be a minor difference in datum leader point data because current leader in the part is a legacy leader so after create/update same leader with new architecture will have minor difference. |
2242407 |
I can't execute 'import'. |
2242419 |
[CAD] I can not edit the Ports in "Qualify Part - Fixture". |
2242425 |
Siemens PLM believes that the problem you reported where the documentation about computing the thickness of a midsurface describing 5 degrees as the distance between sample points is changed to 5% deviation by code changes made to the upcoming release of our software NX 10. |
2242429 |
[CAD] The numerical value set by "Qualify Part - Multi" is cleared. |
2242506 |
Siemens PLM believes that the problem you reported where certain menu entries on the main menu such as Edit Work Section, Copy Display or WCS Orient are no longer available when Verify is started from the main menu will be resolved by code changes made to the release of our product NX version NX 10 and NX 9.0.3 MP 1. |
2242510 |
Siemens PLM believes that the problem you reported where the documentation needs to be updated for NXOpen > FileNewApplication enumeration is updated in NX 10 documentation. |
2242566 |
Siemens PLM believes that the problem you reported where the Show New Set button would become hidden when the Set List was made invisible and then visible in the Block Styler has been fixed in NX 10. The "Show Add New Set" property was inadvertently being set to false when the set list was hidden. A workaround for the problem is to manually enable the "Show Add New Set" property when necessary. |
2242575 |
Welding joint cannot be created on plate edges with hole on boundary. |
2242601 |
Siemens PLM believes that the problem you reported where result will change If reverse the order of selection will be resolved by code changes made to the upcoming release of our software NX 10. |
2242624 |
Siemens PLM believes that the problem you reported where "The creation steps of Dimension differ to the view which created View Break" will be resolved by code changes made to the upcoming release of our software NX 10. |
2242710 |
Siemens PLM believes that the problem you reported where Wrong preview result of Move Face, will be resolved by code changes made to the upcoming release of our software NX 10. |
2242766 |
Siemens PLM believes that the problem you reported where Fail to convert Mechanism data which has special characters in motion name. will be resolved by code changes made to the release of our product NX version 10. |
2242775 |
[CAD] "Extension" does not work correct. |
2242792 |
Siemens PLM believes that the problem you reported where redo button behavior is different than interactive behavior for Winform App will be resolved by code and NXOpen API documentation changes made to the upcoming release of our software NX 10. When user calls theSession.EnableRedo() from his NXOpen application, redo framework clears its internal data structure. Now, if user performs undo to a mark which was set before calling the Session. EnableRedo Redo will not be available for this operation. In short, if user is expecting that it should work such that he can redoes all the 3 lines in a sequence, this will be not possible. But we can restrict the user to perform incorrect action by disabling the Redo Button. Now, Redo button get disabled after doing second Undo and user will not able to perform the incorrect action. We have also updated the NXOpen API documentation of call EnableRedo(), which clearly mention that "Redo is not supported for the visible marks set before making this call." |
2242794 |
Siemens PLM believes that the problem you reported where "Failed to run "Gouge check" with error "memory access violation"" will be resolved by code changes made to the release of our product NX 9.0.3MP1 and NX 10. |
2242895 |
Siemens PLM believes that the problem you reported where "Custom Symbol inserted to the note is overlaps the text" will be resolved by code changes made to the upcoming release of our software NX 10. |
2242902 |
Siemens PLM believes that the problem you reported where Operation of "Edit with Rollback" of a sketch is slow, will be resolved by code changes made to the upcoming release of our software NX 10. |
2242909 |
Siemens PLM believes that the problem you reported where component color changes to the feature color when zoom in & zoom out is as designed. When you set model to large, view dynamics (rotation, zoom, panning) has to be really efficient. NX will switch to lower LODs (level of detailing). When generating LODs during tessellation for lower LODs NX do not preserve the color details and simplify the geometry so that it has minimum number of triangles yet preserving the outline of original geometry. Also there is no definite logic for picking color for lower LODs so you may see system default or green. The above information will be added to assembly help in our upcoming release of NX 10. |
2242970 |
Siemens PLM believes that the problem you reported where biasing on edge is not applied will be resolved by code changes made to the upcoming release of our software NX 10. |
2243193 |
Siemens PLM believes that the problem you reported where the section view becomes out of date by changing the position of top view will be resolved by code changes made to the upcoming release of our software NX 10. |
2243200 |
Siemens PLM believes that the problem you reported where pocket design does not create pocket correctly for some shaped parts will be resolved by code changes made to the upcoming release of our software NX 10. Pocket design does not create pocket correctly for some shaped parts is solved in NX 10 by giving a prompt message when the specified standard part cannot create pocket. |
2243210 |
Siemens PLM believes that the problem you reported where the result of a spherical coordinate system is not correct will be resolved by code changes made to the upcoming release of our software NX 10. |
2243513 |
Siemens PLM believes that the problem you reported where highlight original feature - Alert displayed while checking object information will be resolved by code changes made to the upcoming release of our software NX 10. |
2243591 |
Siemens PLM believes that the problem you reported where using the transform tool to copy instances of the drafting annotation objects changes stacking spacing factor will be resolved by code changes made to the release of our product NX version 10. |
2243592 |
Siemens PLM believes that the problem you reported where dimension arrow position shifts from dimension line in the CGM viewer will be resolved by code changes made to the release of our product NX version 10. |
2243625 |
Siemens PLM believes that the problem you reported where "Sort callout does not works in case of group balloon" will be resolved by code changes made to the upcoming release of our software NX 10. |
2243690 |
Siemens PLM believes that the problem you reported where incorrect result from the Rebend of conical part in NX9.0.2 will be resolved by code changes made to the release of our product NX version 10. |
2243702 |
Can the corrupt Global Shaping features be fixed. |
2243707 |
"Ordinate dimension-> Place Automatically" behave strange after drag dimension. |
2243819 |
The name of "Expressions" is not normally reflected by "Reuselibrary". |
2243832 |
Siemens PLM believes that the problem you reported where "Work screen of NX is unstable after save in "Expand" mode" will be resolved by code changes made to the release of our product NX version 10. |
2243868 |
Siemens PLM believes that the problem you reported where a expression cannot be referred to when Create Interpart Reference is used will be resolved by code changes made to the release of our product NX 10. |
2243922 |
Siemens PLM believes that the problem you reported where "View alignment is not persistent" will be resolved by code changes made to the upcoming release of our software NX 10. |
2243941 |
Siemens PLM believes that the problem you reported where "Center line is shifted in NX 9" will be resolved by code changes made to the release of our product NX version 10. |
2243950 |
Siemens PLM believes that the problem you reported where the position of the circle of PMI in JT shifts will be resolved by code changes made to the release of our product NX 10. |
2244073 |
Siemens PLM believes that the problem you reported where "Position of "Datum feature symbol" is shifted without permission." will be resolved by code changes made to the release of our product NX version 10. |
2244113 |
If I qualify part, extension is 0. |
2244144 |
Siemens PLM believes that the problem you reported where Modification in "View Dependent Edits" does not reflect in Information window will be resolved by code changes made to the release of our product NX version 10. |
2244186 |
Siemens PLM believes that the problem you reported where the link cannot be selected for "relative to selected" in interference dialog will be resolved by code changes made to the upcoming release of our software NX 10.0 |
2244189 |
Siemens PLM believes that the problem you reported where Model Check does not check correctly about Orthotropic material of delta will be resolved by code changes made to the upcoming release of our software NX 10. |
2244222 |
Siemens PLM believes that the problem you reported where part file open in history free mode takes more time compared to history mode will be resolved by code changes made to the upcoming release of our software NX 10. |
2244224 |
Siemens PLM believes that the problem you reported "when the part is History-Free Mode, part saving is slow" will be resolved by code changes made to the upcoming release of our software NX 10. |
2244278 |
Siemens PLM believes that the problem you reported where translation mistake of 'Alignment' will be resolved by code changes made to the release of our product NX version 10. |
2244529 |
Siemens PLM believes that the problem you reported where the time taken to import the part file in history free is more when compared to history mode will be resolved by code changes made to the upcoming release of our software NX 10. |
2244617 |
Position of the view is shifting in NX 9.0. |
2244668 |
Not seen the header and the color bar of JT which is exported from Japanese mode |
2244762 |
Siemens PLM believes that the problem you reported where "True Angle" does not show the result of measurement for angle correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
2244839 |
Siemens PLM believes that the problem you reported where UF_SF_locate_material is not returning an error when the material tag is NULL_TAG will be resolved by code changes made to the upcoming release of our software NX 10. |
2244853 |
Unable to open the assembly file, internal error: memory access violation. |
2244860 |
Siemens PLM believes that the problem you reported where "The strip lift height parameter values of tooling motion simulation are wrong" will be resolved by code changes made to the upcoming release of our software NX 10 |
2244886 |
Siemens PLM believes that the problem you reported where Message is displayed on the Simple Interference, will be resolved by code changes made to the upcoming release of our software NX 10. |
2244902 |
Siemens PLM believes that the problem you reported where The motion direction is reversed with I-deas will be resolved by code changes made to the upcoming release of our software NX 10. |
2244909 |
Siemens PLM believes that the problem you reported where silhouette curve disappears during update will be resolved by code changes made to the upcoming release of our software NX 10. |
2244951 |
Siemens PLM believes that the problem you reported where the 'solid body' included in a layer 180 is not displayed by 'stress wizard 'will be resolved by code changes made to the release of our product NX version 10. |
2245010 |
Siemens PLM believes that the problem you reported where the point was not returned correctly by the user's pick point function will be resolved by code changes made to the upcoming release of our software NX 10. |
2245126 |
Siemens PLM believes that the problem you reported where "Behavior due to differences in the view representation for Drafting." will be resolved by code changes made to the release of our product NX version NX 10. |
2245163 |
Do not updated "Extension" value after creating a fixture. |
2245202 |
Siemens PLM believes that the problem you reported where Solid Fill cannot become hidden will be resolved by code changes made to the upcoming release of our software NX 10.0 |
2245203 |
Siemens PLM believes that the problem you reported where original item type cannot be selected from 'Default Part Type' option will be resolved by code changes made to the upcoming release of our software NX 10. |
2245236 |
Siemens PLM believes that the problem you reported where component moves while converting the matting conditions to assembly constraints will be resolved by code changes made to the upcoming release of our software NX 10. |
2245256 |
Siemens PLM believes that the problem where documentation needs to be added for the "Component is Reference-Only" option is fixed in release NX 10. |
2245373 |
Siemens PLM believes that the problem you reported where 'The following files could not be loaded, causing this open to fail: Object supplied is of the wrong type' error occurs while opening the assembly file will be resolved by code changes made to the upcoming release of our software NX 10. |
2245499 |
Siemens PLM believes that the problem you reported where a help on NX CAE Stress Wizard cannot start will be resolved by code changes made to the upcoming release of our software NX 10ph19. The problem where a help on NX CAE stress wizard cannot start was fixed in release 10ip19. There was also an issue with the vibration wizard help not starting, which was also fixed. |
2245536 |
Siemens PLM believes that the problem you reported where extra feature is output when creating the Linked Part of Part module, will be resolved by code changes made to the upcoming release of our software NX 10. |
2245651 |
Siemens PLM believes that the problem you reported where "Clear Glass of System Material does not work corrector" will be resolved by code changes made to the release of our product NX version 10.0. |
2245795 |
Siemens PLM believes that the problem you reported where "Internal error is displayed when the boundary of a detail view is editing" will be resolved by code changes made to the upcoming release of our software NX 10.The workaround for pre-NX 10 users is to use RMB->Edit instead of RMB->Boundary to change detail view boundary. |
2245835 |
Siemens PLM believes that the problem you reported where the Error occur when do [Identify] in order to evaluate stress of shell will be resolved by code changes made to the upcoming release of our software NX 10ph18. |
2245915 |
Siemens PLM believes that the problem you reported where appropriate Error message should return if part import fail due to naming rule is fixed in the upcoming release of our software NX 10. |
2245930 |
Siemens PLM believes that the problem you reported where a result is not right if a unit system is outputted by mm-sec-tonne will be resolved by code changes made to the release of our product NX 10. |
2245933 |
Siemens PLM believes that the problem you reported where "Wrong workpiece dimensions after preview" will be resolved by code changes made to the release of our product NX 10. |
2246019 |
Siemens PLM believes that the problem you reported where undercut areas are not detected has been investigated and the following has been found. The problem where undercut areas are not detected is working as designed. The documentation has been updated to include the following designed behavior in NX 10 Documentation: NX is designed to ignore small undercut areas that are less than 0.000001 of the total area of the part. This avoids having too many undercut faces reported as undercut areas for complex parts. Although these minute isolated undercut faces are ignored, NX can still identify an undercut condition by detecting undercut edges. |
2246053 |
Siemens PLM believes that the problem you reported where the internal error occurs when I delete a view will be resolved by code changes made to the release of our product NX version 10. The issue where on deletion of view, internal error was observed and view was not getting deleted is fixed in release NX 10 IP21. |
2246155 |
Siemens PLM believes that the problem you reported where "Report shortest tool reports wrong value" will be resolved by code changes made to the release of our product NX 9.0.3MP2 and NX 10. |
2246231 |
Siemens PLM believes that the problem you reported where "Unable to reference edge" error is displayed by bounded plane operation will be resolved by code changes made to the release of our software NX 10. |
2246257 |
Siemens PLM believes that the problem you reported where unneeded KATAKANA characters are displayed in Reuse Paste dialog will be resolved by code changes made to the release of our product NX version 10. |
2246262 |
Siemens PLM believes that the problem you reported where while opening large assembly,' the following files could not be loaded, causing this open to fails error' occurs will be resolved by code changes made to the release of our product NX version 10.0. Possible work around to this problem is to change the load options in some other way. However, better approach is to load the subassemblies first, and then the top level assembly. We believe this will avoid the problem code. If the top level assembly is then saved, save the assembly with all the inherited constraints it needs. Therefore, the problem should not recur on later loads, unless the subassembly is modified again in the future. |
2246295 |
Siemens PLM believes that the problem you reported where "[Allowed Letters] Settings are not reflected in the non-master drawings" will be resolved by code changes made to the release of our product NX version NX 10.0 |
2246310 |
Siemens PLM believes that the problem you reported where the part file cannot be opened will be resolved by code changes made to the release of our product NX version 10.0 The part file fixed in NX 8.5.3 will be uploaded to the returned folder for which you will be notified by separate mail. |
2246313 |
When I refresh Teamcenter information, Modified icon is displayed. |
2246413 |
Siemens PLM believes that the problem you reported where the result of 1D duct flow is not displayed correctly in NX 9 will be resolved by code changes made to the release of our product NX version 10. |
2246435 |
Siemens PLM believes that the problem you reported where Character string of log of ug_export is abnormal will be resolved by code changes made to the release of our product NX version 10. |
2246547 |
Siemens PLM believes that the problem you reported where Collection.ToArray() method does not works for some classes will be resolved by code changes made to the release of our product NX version 10. |
2246566 |
Siemens PLM believes that the problem you reported where documentation of NXOpen.BlockStyler >StringBlock > IsPassword needs to be update is updated in NX 10. |
2246574 |
Siemens PLM believes that the problem you reported where the part file cannot be opened with 'Internal Error: Memory access violation' error message will be resolved by code changes made to the release of our product NX version 10. |
2246584 |
Siemens PLM believes that the problem you reported where "Edit partlist and get error "Use askUserMessage ( ) or askSyslogMessage ( )"" will be resolved by code changes made to the release of our product NX 10. |
2246612 |
Siemens PLM believes that the problem you reported where Two bodies are selected wrongly even when only one body is selected will be resolved by code changes made to the release of our product NX 10. |
2246618 |
Siemens PLM believes that the problem you reported where an alert is displayed although item ID does not overlap will be resolved by code changes made to the release of our product NX version 10. |
2246669 |
Siemens PLM believes that the problem you reported where the measurement value become zero was due to Recurdyn solver's result .RecurDyn explained that the AX function requires the x-axis of the two markers be parallel. If the x-axes are not parallel, the result could be meaningless. When the angle between x-axes exceed 60 degree, RecurDyn solver will give zero. This information was updated in the notes for the AX function of recurdyn_functions_expressions.pdf. This updated PDF will be available in the NX 10 Motion Simulation online help under the Solver Information section. |
2246676 |
Lead line does not move correctly by [Move Object]. |
2246701 |
Siemens PLM believes that the problem you reported where PMI information is garbled when JT with PMI data is opened in NX 9.0.2 will be resolved by code changes made to the release of our product NX version 10. |
2246763 |
Siemens PLM believes that the problem you reported where 3D swept mesh was not possible for particular polygon body will be resolved by code changes made to the release of our product NX version 10. |
2246837 |
Siemens PLM believes that the problem you reported where Post file created in PB5.0 cannot be saved with error in PB7.5 and beyond will be resolved by code changes made to the release of our product NX version P10.0/phase 20. |
2246986 |
NX always shows "Window 1" for the header on the graph windows on Japanese mode. |
2247061 |
Siemens PLM believes that the problem you reported where Rib shape has been removed by Draft From Edge given to another face will be resolved by code changes made to the release of our product NX version 10. |
2247137 |
Siemens PLM believes that the problem you reported where "NX create the wrong toolpath with skaky motion" will be resolved by code changes made to the release of our product NX 10. |
2247310 |
Siemens PLM believes that the problem you reported about position of the center of gravity shift of the "fixed link" will be resolved by code changes made to the release of our product NX 10. |
2247329 |
Siemens PLM believes that the problem you reported where in Face analysis ( Reflection) some of the surfaces are hidden will be resolved by code changes made to the release of our product NX version NX 10. |
2247330 |
Siemens PLM believes that the problem you reported where the surfaces are not highlighted according to selection in Face analysis - Reflection will be resolved by code changes made to the release of our product NX version 10 and upcoming Maintenance Pack of NX 9.0.3 |
2247518 |
Siemens PLM believes that the problem you reported where repeated clearance analysis on the same assembly gives different numbers of interferences will be resolved by code changes made to the release of our product NX version 10. |
2247571 |
There is a mis-translation at in [Region] dialog in NX Japanese version. |
2247585 |
Japanese translation of the Join Isocline Curves is incorrect. |
2247669 |
Siemens PLM believes that the problem you reported where in NX9 some CBEAM elements in mesh have an invalid orientation. will be resolved by code changes made to the release of our product NX 10. |
2247781 |
Incorrect translation of Reflection Data dialog box |
2247857 |
Siemens PLM believes that the problem you reported where "gouge check show output Internal error memory access violation" will be resolved by code changes made to the release of our product NX9.0.3 MP1 and NX 10. |
2248013 |
Orientation of PMI dimension text is changed when export to JT. |
2248058 |
Siemens PLM believes that the problem you reported where sketchProjectBuilder.commit() does not return committed NXObject will be resolved by code changes made to the release of our product NX 10. |
2248072 |
Siemens PLM believes that the problem you reported where the created trim length exceeds "Minimum Length" value with the warning message will be resolved by code changes made to the release of our product NX version P10.0/phase 1. |
2248256 |
Siemens PLM believes that the problem you reported where The problem where the Automatic Coupling constraint may not consider nodes on 1-D elements as potential candidates will be resolved by code changes made to the release of our product NX version 10.0 |
2248258 |
Siemens PLM believes that the problem you reported where Automatic Coupling constraint was not able to delete in NX 9 which is created in NX 8 will be resolved by code changes made to the release of our product NX version 10. |
2248317 |
Siemens PLM believes that the problem you reported where "Type Filter" is reset if Pan is performed will be resolved by code changes made to the release of our product NX 10. |
2248577 |
Siemens PLM believes that the problem you reported where the Node Association becomes duplication nodes by solid mesh will be resolved by code changes made to the release of our product NX version 10. |
2248676 |
Siemens PLM believes that the problem you reported where "Difference in the behavior of the [View Dependent Edit]" will be resolved by code changes made to the release of our product NX version 10.0. This is working as designed for exact views. When silhouettes are turned off, they are not being processed, so it doesn't matter whether they have any references or not, they are not displayed. A workaround is to leave silhouettes on, and add view dependent erasures to the silhouettes that are not to be displayed. The NX 10 Drafting Help documentation is updated with the following information to explain this change: "Silhouettes that are referenced by view dependent edits are not displayed in views with an Exact representation if the display of silhouettes is turned off for the view. If only certain silhouettes need to be displayed, then you must display all silhouettes and use the View Dependent Edit command to erase silhouettes you do not want displayed". |
2248775 |
Siemens PLM believes that the problem you reported where "The position of a datum symbol is changing" will be resolved by code changes made to the release of our product NX version 10. |
2248782 |
Siemens PLM believes that the problem you reported where Macro cannot playback after Undo operation will be resolved by code changes made to the release of our product NX 10. |
2248814 |
Siemens PLM believes that the problem you reported where NXOpen C# Wizard creates external (batch) program that will not execute will be resolved by code changes made to the release of our product NX 10. |
2249059 |
Siemens PLM believes that the problem you reported where Different item is opened in "Advanced Search" will be resolved by code changes made to the release of our product NX version 10 and a back port is being considered by development for NX 9. |
2249406 |
Siemens PLM believes that the problem you reported where the result of Move Object is different when using Move Handles Only will be resolved by Document changes made to the release of our product NX version 10.0 Online Help. "Allows you to reposition only the CSYS manipulator without also repositioning the objects. This lets you locate and orient the CSYS manipulator for the next motion that you want to specify within the same operation. Clear the option to specify the motion from that particular position of the CSYS manipulator." Renamed the option in the Help to "Move Handles Only". |
2249447 |
Siemens PLM believes that the problem you reported where custom symbol can't be created will be resolved by code changes made to the release of our product NX version 10. |
2250012 |
Siemens PLM believes that the problem you reported about the license problem of thermal/flow patch 9.0.368 for the "deactivation set advanced" command in Space System Thermal will be resolved by code changes made to the release of our product NX version 10. |
2250175 |
Siemens PLM believes that the problem you reported where dimensions created are not included to active sketch group automatically has been investigated and the following has been found. The problem where dimensions created are not included to active sketch group automatically is working as designed. The documentation has been updated to note that only sketch curves, NOT dimensions, are added to the active sketch group in NX 10 documentation. |
2250262 |
Siemens PLM believes that the problem you reported where "View dependent edit" is not working correctly will be resolved by code changes made to the release of our product NX version 10. |
2250708 |
Siemens PLM believes that the problem you reported where DB_Part_Name in ANT as overwritten after cloning the solution in motion sim will be resolved by code changes made to the release of our product NX version 10. |
2250753 |
Siemens PLM believes that the problem you reported where "Behavior due to differences in the view representation for..." will be resolved by code changes made to the release of our product NX version NX 10. |
2250853 |
Unable to project a curve as intended in NX 9.0.3. |
2250854 |
Unable to project a curve to certain face. |
2250999 |
Japanese Localization for Post Processor Dialog UI strings are in-correct. |
2803793 |
Siemens PLM believes that the problem you reported where there was an error when opening a solid works file, will be resolved by code changes made to the upcoming release of our software NX 10. |
2805540 |
Siemens PLM believes that the problem you reported where open this Solidworks 2012 sldasm in NX gives incorrect results will be resolved by code changes made to the upcoming release of our software NX 10.Note - Two issues were found when looking at the attached assembly. The first issue required a code fix and this has been included in NX 10. The second issue was that one of the part file names in the attached zip archive was incorrect. When name was changed to "203012006 - Rodamiento de rodillos cónicos 32210.SLDPRT" the complete assembly was loaded as expected. |
2806678 |
Siemens PLM believes that the problem you reported where PMI Dimensions aren't rounding correctly in part navigator (resource bar) will be resolved by code changes made to the upcoming release of our software NX 10. |
2807480 |
Siemens PLM believes that the problem you reported where Unite of promotion Bodies results in wrong mass in the ANT will be resolved by code changes made to the upcoming release of our software NX 10. |
2807529 |
Siemens PLM believes that the problem you reported where Update view hides the detail view label will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 10. |
4946261 |
The problem of importing a *.xml.txt file has been fixed in TcEng 2005 mp1. |
5357899 |
Siemens PLM believes that the problem you reported where the order of columns in a wire stock ptb file was affecting stock creation, will be resolved by code changes made to the upcoming release of our software NX 10. |
5748110 |
Siemens PLM believes that the problem you reported where ugtopv translator pulling NX license for Wave/Interpart Data, will be resolved by code changes made to the upcoming release of our software NX version 10. |
5778933 |
Siemens PLM believes that the problem you reported where'ROUTE_CHOOSE_PART_PLACE_PART plugin lack of Documentation' will be resolved by code changes made to the release of our product _______ version _______ {Responsible SE enters release/version here} |
5956323 |
Siemens PLM believes that the problem you reported where certain text characters are translated as Kanji looking characters when importing/opening a dxf file, will be resolved by code changes made to the upcoming release of our software NX 10. |
6004027 |
The "trouble with profiles not saving correctly in sdi print" problem has been fixed in NX 10, phase 18 with our latest SDI libraries. |
6004595 |
Siemens PLM believes that the problem you reported where Routing Characteristics were not listed on the Specify Item dialog having selecting a specification when filtering stock, will be resolved by code changes made to the upcoming release of our software NX 10. |
6014478 |
PS26.01.074 fix. "Move Face" doesn't work with some value. |
6034724 |
Siemens PLM believes that the problem you reported where the Full Leroy font is not translating in NX6 as in NX 5 did will be resolved by code changes made to the upcoming release of our software NX 10. |
6036913 |
Siemens PLM believes that the problem you reported where the update_fam_from_ptb utility failed to work when the -pim Teamcenter Integration switch was used, will be resolved by code changes made to the upcoming release of our software NX 10. |
6037881 |
Siemens PLM believes that the problem you reported where there is a problem exporting files to DXF will be resolved by code changes made to the upcoming release of our software NX 10. |
6043681 |
Error when attempting to load a part file. |
6047100 |
Replace Part does not unroute wires that are no longer valid. |
6054765 |
Siemens PLM believes that the problem you reported where exporting a 2D Exchange NX drawing is causing the vectors and normals to reverse will be resolved by code changes made to the upcoming release of our software NX 10. |
6067072 |
Default vector direction of Contour flange is not in material side. |
6085002 |
Siemens PLM believes that the problem you reported where you were unable to select Port when Placing Part will be resolved by code changes made to the upcoming release of our software NX 10. |
6091856 |
Siemens PLM believes that the problem you reported where the Customer Default settings do not work with Electrical App View will be resolved by code changes made to the upcoming release of our software NX 10. |
6104979 |
Siemens PLM believes that the problem you reported where Analysis->Minimum Radius would sometimes not report a radius in a concave face and something report a radius on a convex face will be resolved by code changes made to the upcoming release of our software NX 10 |
6140204 |
Siemens PLM believes that the problem you reported where The NX Status Line no longer reports "Loading Part Table ..." when invoking a Routing application, will be resolved by code changes made to the upcoming release of our software NX 10. |
6168458 |
Siemens PLM believes that the problem you reported where STEP import resulted in missing faces for the supplied part, will be resolved by code changes made to the upcoming release of our software NX 10. |
6205656 |
Siemens PLM believes that the problem you reported where dimension text is shifted into the dimension lines when a DWG is imported into NX will be resolved by code changes made to the release of our software NX 10. |
6220026 |
Siemens PLM believes that the problem you reported where inconsistent results were observed using Parallel Offset Path having closed and reopened a part, will be resolved by code changes made to the upcoming release of our software NX 10. |
6229971 |
Siemens PLM believes that the problem you reported where the backshell component is not bringing the built-in path correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
6229992 |
Siemens PLM believes that the problem you reported where there a missing entities following an Export/Import of DXF will be resolved by code changes made to the upcoming release of our software NX 10. |
6241647 |
Siemens PLM believes that the problem you reported where DXF import to NX - The crosshatch is incorrect will be resolved by code changes made to the upcoming release of our software NX 10. |
6250453 |
Siemens PLM believes that the problem you reported where Notes exported to DXF with 2D Exchange are incorrect will be resolved by code changes made to the upcoming release of our software NX 10. |
6252142 |
Siemens PLM believes that the problem you reported where the user cannot import a DWG file will be resolved by code changes made to the upcoming release of our software NX 10. |
6252414 |
In Trim Sheet operation, the area which the user does not select is kept. |
6274158 |
PS27.0.178 fix. Move face develops strange planer face |
6295560 |
PS26.01.057 fix: NX 7.5 UAF Testing - Part fails to update in NX 7.5 but updates |
6306559 |
Siemens PLM believes that the problem you reported where corners are not created for 2 of 8 stocks will be resolved by code changes made to the upcoming release of our software NX 10. |
6309904 |
Siemens PLM believes that the problem you reported where there are some general issues with the 2d exchange program will be resolved by code changes made to the upcoming release of our software NX 10. |
6315443 |
Siemens PLM believes that the problem you reported where the Knowledge Fusion example: %UGII_ROOT_DIR%\\dfa\\examples\\modeling\\ug_extract_face_example_xform_path.dfa did not work when working in context will be resolved by code changes made to the upcoming release of our software NX 10 where the example will now include the phrase "where work part is displayed part" to explain that it is not designed to work in context (display part != work part.) |
6336596 |
Siemens PLM believes that the problem you reported where an extra "RAPID" is output when an NX4 part operation was regenerated in NX 6 will be resolved by code changes made to the upcoming release of our software NX 10. |
6352457 |
Siemens PLM believes that the problem you reported where the user received an error "Thru face does not intersect path of tool when doing a subtract", will be resolved by code changes made to the upcoming release of our software NX 10. |
6368485 |
Siemens PLM believes that the problem you reported where performing a 2D Exchange of this part results in an incorrect display for the full bolt circles on the drawing, will be resolved by code changes made to the upcoming release of our software NX 10. |
6375680 |
NC: v-sweep cookie cut wrong results. |
6377893 |
Siemens PLM believes that the problem you reported where Formbroad returned the message "An attempt was made to associate an object with a second other object" will be resolved by code changes made to the upcoming release of our software NX 10. |
6380567 |
Reset Filter does not reset color filter in drafting. |
6396407 |
PSv27.0.121 Cant create Law Controlled Face Blend. |
6409178 |
Siemens PLM believes that the problem you reported where Autocad custom white paper drawing size is not correct in 2Dxchange will be resolved by code changes made to the upcoming release of our software NX 10. |
6413744 |
v-sweep robust rail mapping detects incorrect stagnation. |
6421785 |
Siemens PLM believes that the problem you reported where a Virtual Intersection did not display for a revolved body, will be resolved by code changes made to the upcoming release of our software NX 10. |
6450366 |
Siemens PLM believes that the problem you reported where exporting a PLMXML file gives an error, "wrong object type", will be resolved by code changes made to the upcoming release of our software NX 10. |
6454070 |
Siemens PLM believes that the problem you reported where Auto-assign fails on a replaced device will be resolved by code changes made to the upcoming release of our software NX 10. |
6456305 |
Undesirable Broken Linked Face is created during Spline Path creation |
6457303 |
Siemens PLM believes that the problem you reported where not all bodies are imported into NX will be resolved by code changes made to the upcoming release of our software NX 10. |
6460708 |
Siemens PLM believes that the problem you reported where the Output Coordinates Reference setting in the Point dialog is not being remembered will be resolved by code changes made to the upcoming release of our software NX 10. |
6467591 |
Siemens PLM believes that the problem you reported where the Routing PART_NAME characteristic is missing and cannot be found will be resolved by code changes made to the upcoming release of our software NX 10. |
6472082 |
Siemens PLM believes that the problem you reported where an error was returned while creating a Formboard in managed mode will be resolved by code changes made to the upcoming release of our software NX 10. |
6477841 |
Siemens PLM believes that the problem you reported where Manual Routing raises an internal error will be resolved by code changes made to the upcoming release of our software NX 10. Now when you Manual Route --> Component Level, the Information Window reports "No paths pass through the intermediate components. Check routing level (pin versus component) and path". |
6480938 |
Siemens PLM believes that the problem you reported where Mechanical Routing Stock raised errors after installing an NX 7.5.2 Routing patch, will be resolved by code changes made to the upcoming release of our software NX 10. |
6483748 |
Siemens PLM believes that the problem you reported where NX says the units are missing when loading an exported monolithic jt file from TcVis will be resolved by code changes made to the upcoming release of our software NX 10. |
6499460 |
Siemens PLM believes that the problem you reported where fractions in Notes were not correctly translated will be resolved by code changes made to the upcoming release of our software NX 10. |
6506011 |
Overstock disappears on editing a spline path. |
6506702 |
Siemens PLM believes that the problem you reported where adding Overstock raises "UPDATE/DELETE has gone through too many iterations" will be resolved by code changes made to the upcoming release of our software NX 10. |
6507024 |
Stock Offset Surface does not work for Linear Path without Interpart Link. |
6507066 |
After Simplify Path, Rect Angle SR with Orientation Angle are rotated. |
6510479 |
Siemens PLM believes that the problem you reported where virtual intersection line fonts are not displaying properly will be resolved by code changes made to the upcoming release of our software NX 10. |
6517795 |
Siemens PLM believes that the problem you reported where the Customer Default Radius Method is not applied will be resolved by code changes made to the upcoming release of our software NX 10. |
6528405 |
Siemens PLM believes that the problem you reported where cgm2pdf" documentation and '-Help' is misleading, will be resolved by code changes made to the upcoming release of our software NX 10. |
6533429 |
Siemens PLM believes that the problem you reported where the errors are ambiguous when importing the PLV files into Teamcenter for Electrical Routing will be resolved by code changes made to the upcoming release of our software NX 10. |
6536962 |
This PR has been reviewed by development. Due to the low priority of the problem and the length of time the current behavior has been in the system we do not intend to fix this PR. If the problem is still impacting your day to day operation as you use the NX product, please contact GTAC to have the PR reopened. |
6539544 |
Siemens PLM believes that the problem you reported where the NX Open Programmer's Guide did not explain how to handle translations of dialogs and menus when custom applications will be used in locations where other languages are spoken will be resolved by documentation changes made to the release of our product NX 10. |
6543970 |
Siemens PLM believes that the problem you reported where Place Part raised the message: "Unable to load the requested part see syslog", will be resolved by code changes made to the upcoming release of our software NX 10. |
6544727 |
Siemens PLM believes that the problem you reported where a view was missing having imported a dxf file, will be resolved by code changes made to the upcoming release of our software NX 10. |
6550889 |
Siemens PLM believes that the problem you reported where the Routing Customer Default "Radius Method" was ignored, will be resolved by code changes made to the upcoming release of our software NX 10. |
6552382 |
Siemens PLM believes that the problem you reported where Node Proximity to CAD Geometry is using the wrong surface for selecting nodes will be resolved by code changes made to the upcoming release of our software NX 10. |
6555284 |
Siemens PLM believes that the problem you reported where the User cannot convert a drawing to 2D Exchange will be resolved by code changes made to the upcoming release of our software NX 10. |
6556131 |
Siemens PLM believes that the problem you reported where opening a drawing from Teamcenter failed, but the same file would open from NX will be resolved by code changes made to the upcoming release of our software NX 10. |
6563849 |
Siemens PLM believes that the problem you reported where adding new component attributes to a generated XML file was failing will be resolved by code changes made to the upcoming release of our software NX 10. |
6563896 |
Siemens PLM believes that the problem you reported where an ambiguous message was raised when the user did not have the correct privileges to replace/remove/delete a file when creating a PDF, will be resolved by code changes made to the upcoming release of our software NX 10. |
6565626 |
During "Place Part" broken wave link port is not displaying instantly in PNT. |
6568123 |
Siemens PLM believes that the problem you reported where the NX Open API Programmer's guide did not provide information about debugging NX Open Java applications using eclipse will be resolved by code changes made to the release of our product NX version 10. |
6569329 |
Siemens PLM believes that the problem you reported where attempting to replace stock using the Mechanical Routing application raised the following message: "Routing: Cannot find member in part family", will be resolved by code changes made to the upcoming release of our software NX 10. |
6570396 |
Siemens PLM believes that the problem you reported where Interpart Expressions did not update when used in Part Family Criteria, will be resolved by code changes made to the upcoming release of our software NX 10. |
6575682 |
Siemens PLM believes that the problem you reported where the child rules of the Knowledge Fusion class nx_associative_line were not updating correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
6576543 |
Siemens PLM believes that the problem you reported where Components were not positioned correctly in drawing views, will be resolved by code changes made to the upcoming release of our software NX 10.The problem is fixed in NX 10 by providing a Part Cleanup solution that fixes up the positions of the components in the drawing views. After running Part Cleanup on the assembly, the drawing views will need to be updated to reflect the correct location. |
6577673 |
Siemens PLM believes that the problem you reported where the Name Attribute of a Multiport was not saved, will be resolved by code changes made to the upcoming release of our software NX 10. |
6578633 |
Siemens PLM believes that the problem you reported where a file that only had 7 characters in the name and revision raised the message: "The name 'Highest Numeric Revision-modified' exceeds the allowed length of 32", which also caused the save to fail, will be resolved by code changes made to the upcoming release of our software NX 10. |
6580548 |
Siemens PLM believes that the problem you reported where Null Tag Not Allowed error is raised editing a spline path will be resolved by code changes made to the upcoming release of our software NX 10. |
6584393 |
Siemens PLM believes that the problem you reported where the Routing Mechanical Create Fabrication in NX 6 does not use the customer seed part will be resolved by code changes made to the upcoming release of our software NX 10. |
6588644 |
Siemens PLM believes that the problem you reported where NX Viewer would not come up when double clicking a part will be resolved by code changes made to the release of our product NX 10. |
6589189 |
Siemens PLM believes that the problem you reported where an NX session hangs defining stock offset point will be resolved by code changes made to the release of our product NX version 10. |
6603058 |
Siemens PLM believes that the problem you reported where the auto-route in NX8 is slow will be resolved by code changes made to the upcoming release of our software NX 10. |
6604338 |
Siemens PLM believes that the problem you reported where the NX Open legacy C API function UF_OBJ_cycle_objs_in_part was returning objects on layer 271, will be resolved by code changes made to the upcoming release of our software NX 10, where a new function UF_OBJ_cycle_objs_in_part1 can be used to only find objects on layers 1 - 256. |
6606936 |
Siemens PLM believes that the problem you reported where the documentation for the legacy NX Open C API function UF_MTX3_rotate_about_axis needed to provide more information about how to use the resulting rotation matrix will be resolved by code changes made to the upcoming release of our software NX 10. |
6607037 |
Siemens PLM believes that the problem you reported where the documentation for the NXOpen > FontCollection > AddFont method did not state that if the Font is already in the part it will return the existing Integer ID (index), will be resolved by code changes made to the upcoming release of our software NX 10. |
6619239 |
Siemens PLM believes that the problem you reported where loading a Formboard using the Precise Revision Rule did not load the connectors, raising an Invalid Object warning, will be resolved by code changes made to the upcoming release of our software NX 10. |
6621688 |
Siemens PLM believes that the problem you reported where the NX Open legacy C API function UF_OBJ_cycle_objs_in_part was returning objects on layer 271, will be resolved by code changes made to the upcoming release of our software NX 10.0, where a new function UF_OBJ_cycle_objs_in_part1 has been created to return only objects on layers 1 - 256. |
6623303 |
Siemens PLM believes that the problem you reported where it is not possible to export an Assembly to STP from a Linux Teamcenter installation will be resolved by code changes made to the upcoming release of our software NX 10. |
6623356 |
Need documentation for ss2ptb updated and add steps to create. |
6647881 |
Siemens PLM believes that the problem you reported where an internal error was raised when Updating a Harness, will be resolved by code changes made to the upcoming release of our software NX 10. |
6649347 |
Siemens PLM believes that the problem you reported where you were getting 'Could not detect a cut region' for a Groove operation if the previous tool was modified will be resolved by documentation changes made to the release of our product in NX 10.We have added a note to the docs to better explain the current functionality. Home--> CAM--> Manufacturing Turning--> Roughing overview--> Linear Roughing options. |
6649899 |
Siemens PLM believes that the problem you reported where modifying a path using Legacy Formboard raises the error "This operation encountered an error, causing an undo to be performed. You may safely continue with the session; please report this as an NX Routing problem" will be resolved by code changes made to the upcoming release of our software NX 10. |
6649951 |
Siemens PLM believes that the problem you reported where Stock Characteristics were not written to Stock Component Attributes, will be resolved by code changes made to the upcoming release of our software NX 10. |
6654616 |
Siemens PLM believes that the problem you reported where Optional Characteristics for Stock that were defined in the Application View File were not appearing in the Edit Stock Characteristics dialog, will be resolved by code changes made to the upcoming release of our software NX 10. |
6655499 |
Siemens PLM believes that the problem you reported where you were unable to generate formboard cut sheet tabular annotations in the formboard drawing will be resolved by code changes made to the upcoming release of our software NX 10. |
6660648 |
Siemens PLM believes that the problem you reported where Space Reservation disappeared once created and rcp's at corners were disappearing, will be resolved by code changes made to the upcoming release of our software NX 10. |
6664524 |
Siemens PLM believes that the problem you reported where editing a note in a read-only file caused the note to be copied and placed outside the drawing border, will be resolved by code changes made to the upcoming release of our software NX 10. |
6676089 |
Siemens PLM believes that the problem you reported where Stock As Components setting is ignored switching between Electrical and Mechanical will be resolved by code changes made to the upcoming release of our software NX 10. |
6679554 |
Siemens PLM believes that the problem you reported where adding stock from a part file fails raising the error "user exit to database failed" will be resolved by code changes made to the upcoming release of our software NX 10. |
6685745 |
Siemens PLM believes that the problem you reported where the Selection Scope for move objects in an assembly is not consistent, will be resolved by code changes made to the upcoming release of our software NX 10. |
6686121 |
Siemens PLM believes that the problem you reported where creating a formboard in managed mode raises the error "This operation encountered an error..." will be resolved by code changes made to the upcoming release of our software NX 10. |
6686996 |
Siemens PLM believes that the problem you reported where you were getting a FEDRAT/IPR,100.0000 when the feed is set to 100% of the Cut Feed will be resolved by code changes made to the NX 10 release of our product. |
6688286 |
Siemens PLM believes that the problem you reported where a license error was not reported accessing 'Optimized To Drive tool-axis function', will be resolved by code changes made to the upcoming release of our software NX 10. |
6688535 |
Siemens PLM believes that the problem you reported where a production file (Not a Save As) is exploding at the IA level will be resolved by code changes made to the upcoming release of our software NX 10. |
6707047 |
Siemens PLM believes that the problem you reported where the snap increment is not retained when repositioning text will be resolved by code changes made to the upcoming release of our software NX 10. |
6713580 |
Siemens PLM believes that the problem you reported where Formboard Synchronization failed, having routed a spline path to a fixture port on a backshell, will be resolved by code changes made to the upcoming release of our software NX 10. |
6716578 |
Siemens PLM believes that the problem you reported where Move Object does not obey modeling preference for new face display properties will be resolved by code changes made to the upcoming release of our software NX 10. |
6717064 |
Cannot keep Space Reservation translucency while creating routing path. |
6717587 |
Siemens PLM believes that the problem you reported where "Simulation file is marked as "Modified!" will be resolved by code changes made to the release of our product NX version 10. |
6718763 |
Spline Path-> edit spline point behave strange for successive selected points. |
6720270 |
Finishing sketch of extrude creates Datum CSYS. |
6720643 |
Siemens PLM believes that the problem you reported where creating an FCF with an appended User Defined Symbol created a leader that was no longer centered to the FCF, will be resolved by code changes made to the upcoming release of our software NX 10. |
6720697 |
Siemens PLM believes that the problem you reported where deforming a component raised the error: "Failed to find mapping curve" and then failed, will be resolved by code changes made to the upcoming release of our software NX 10. |
6721000 |
Customer Default setting for Normal Cutout Depth Type is not followed. |
6721872 |
Update Error dialog pop up in Tc Env only. |
6723269 |
Siemens PLM believes that the problem you reported where the Open C function UF_ATTR_ask_part_attrs_in_file() fails when file path starts "..\\..\\" will be resolved by code changes made to the upcoming release of our software NX 10. |
6723898 |
Siemens PLM believes that the problem you reported where the user cannot use Discontinuity RCP as path start point. will be resolved by code changes made to the upcoming release of our software NX 10. |
6728649 |
Siemens PLM believes that the problem you reported where 2d exchange is not able to translate, will be resolved by code changes made to the upcoming release of our software NX 10. |
6731775 |
Siemens PLM believes that the problem you reported where no ports were displayed at path discontinuity if circular reservation was assigned, will be resolved by code changes made to the upcoming release of our software NX 10. |
6747846 |
Siemens PLM believes that the problem you reported where an internal error is raised editing a point on a spline path will be resolved by code changes made to the upcoming release of our software NX 10. |
6751244 |
Siemens PLM believes that the problem you reported where the NX session hangs when opening a DXF file, will be resolved by code changes made to the upcoming release of our software NX 10. |
6754066 |
Siemens PLM believes that the problem you reported where XC value converts back to Metric, though analysis units is set to inches in a metric part, in point dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
6754338 |
Siemens PLM believes that the problem you reported where a Radial Bend leaves connector behind and deletes stock will be resolved by code changes made to the upcoming release of our software NX 10. |
6759817 |
Siemens PLM believes that the problem you reported where a face can only be selected at it's edges will be resolved by code changes made to the upcoming release of our software NX 10. |
6760632 |
Siemens PLM believes that the problem you reported where checking out and checking in the Assemblies license in Drafting enables "WAVE Geometry Linker", will be resolved by code changes made to the upcoming release of our software NX 10. |
6765983 |
Siemens PLM believes that the problem you reported where starting the Block UI Styler application or running any NXOpen API application which uses a Block Styler dialog caused the Draft dialog to stop retaining the most recently used Type will be resolved by code changes made to the release of our product NX 10. |
6767990 |
Siemens PLM believes that the problem you reported where adding a deformable component raised the error: "Failed to find mapping curve", will be resolved by code changes made to the upcoming release of our software NX 10. |
6768492 |
Siemens PLM believes that the problem you reported where Move Object via Distance Between Points is not working as expected, will be resolved by documentation changes made to the upcoming release of our software NX 10.Changes to the first paragraph in the Modeling Help for the Move Object, Distance Between Points option, have been made to the documentation as follows: Distance between Points - A linear distance derived from an origin point and a reference measurement point. When you specify the origin and measurement points and the vector, the current distance between the points appears in the Distance box. You can then specify a new value in the Distance box to move the object along the vector to a new relative location. Callout numbers in the image example were added to help identify the origin point, measurement point, and distance. |
6771042 |
Siemens PLM believes that the problem you reported where the Routing measurement holder is not being placed correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
6774019 |
Siemens PLM believes that the problem you reported where you were unable to move the Spline Path will be resolved by code changes made to the upcoming release of our software NX 10. |
6774755 |
Siemens PLM believes that the problem you reported where an exported part showed up in the History Tab after exporting an assembly outside of Teamcenter to the native file system, will be resolved by code changes made to the upcoming release of our software NX 10. |
6775964 |
Siemens PLM believes that the problem you reported where you could not delete or edit a Routing Stock will be resolved by code changes made to the upcoming release of our software NX 10. |
6780241 |
Siemens PLM believes that the problem you reported where Maple Worksheet Integration did not release floating licenses, will be resolved by code changes made to the upcoming release of our software NX 10. |
6783193 |
Siemens PLM believes that the problem you reported where the Constraints are not consistent in Electrical Routing when Placing Part will be resolved by code changes made to the upcoming release of our software NX 10. |
6785832 |
Siemens PLM believes that the problem you reported where Hide or Show Feature Group removes an object from the Reference Set that it was in will be resolved by code changes made to the release of our product NX 10. |
6790789 |
Siemens PLM believes that the problem you reported where attempting to add a Routing part from the Reuse Library, that was just imported into Teamcenter, raised the message: "Unable to load the requested part", will be resolved by code changes made to the upcoming release of our software NX 10. |
6791972 |
Siemens PLM believes that the problem you reported where Load All Defaults is not taking the Drawing Part units, but instead the Component units, will be resolved by code changes made to the upcoming release of our software NX 10. |
6793594 |
Siemens PLM believes that the problem you reported where a DXF/DWG translation does not successfully convert annotation and views, will be resolved by code changes made to the upcoming release of our software NX 10. |
6806069 |
Siemens PLM believes that the problem you reported where Revolved Section Curves became unassociated after editing a WAVE linked parent, if the section curves were selected as Single Curve, will be resolved by code changes made to the upcoming release of our software NX 10. |
6809808 |
Internal errors when opening routing assembly. |
6813706 |
Siemens PLM believes that the problem you reported where the results of stock information listed "UNKNOWN_OVERSTOCK", will be resolved by code changes made to the upcoming release of our software NX 10. |
6817235 |
Siemens PLM believes that the problem you reported where there is no detailed information in documentation for programming tapered threads will be resolved by code changes made to the release of our product NX version 10. We added a new topic to TDOC - Machine an Internal Thread in a Tapered Hole. This is a procedure topic that demonstrates how to program a NPT thread when there is no geometry or feature modeled in the part. The user can program the tapered thread using data stored in NX in an NPT table. |
6819822 |
Siemens PLM believes that the problem you reported where edits made to spindle speed and direction are saved even if the operations was not saved will be resolved by code changes made to the upcoming release of our software in NX 10. |
6826896 |
The problem where the Aero Sheet Metal fails to unform if Joggle is used on a radiused bend has been investigated and the following has been found. There is a workaround in NX 10 which could be flattened using Unbend: 1. Switch to NX Sheet Metal (Application -> Sheet Metal). 2. Convert to Sheet Metal, selecting the bends of Advanced Flange as the "Additional Geometries". 3. Unbend the advanced flanges. They will unfold successfully. |
6826944 |
Siemens PLM believes that the problem you reported where orienting the Base View, the sheets go from 1-1 to 1-2 sheets will be resolved by code changes made to the upcoming release of our software NX 10. |
6830568 |
Siemens PLM believes that the problem you reported where, if you assign the stock first and then create the Discontinuity, the stock ports do not connect will be resolved by code changes made to the upcoming release of our software NX 10. |
6834846 |
Siemens PLM believes that the problem you reported where Load All Defaults was not taking the Component's units and not the Drawing Part's units, will be resolved by code changes made to the upcoming release of our software NX 10. |
6839067 |
Siemens PLM believes that the problem you reported where color changes made to the faces of a tool body (after a Trim Body command had been completed) were not reflected in the target body when Boolean Face Properties From had been set to "Tool Body", will be resolved by code changes made to the release of our product NX 10. |
6843735 |
Siemens PLM believes that the problem you reported where Solid Works files have different units when opened in NX 8.5 versus NX 8 will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10. |
6844587 |
Siemens PLM believes that the problem you reported where a Port on a path remained displayed after using Place Part, will be resolved by code changes made to the upcoming release of our software NX 10. |
6846380 |
Siemens PLM believes that the problem you reported where Ports were not consumed as expected, will be resolved by code changes made to the upcoming release of our software NX 10. |
6851664 |
Siemens PLM believes that the problem you reported where drawing opened as modified after being saved, will be resolved by code changes made to the upcoming release of our software NX 10.An assembly with this configuration will no longer be marked as modified on load when reloading it following a save. |
6853073 |
Siemens PLM believes that the problem you reported where Heal Path did not move with a component unless edited and reattached to a port, will be resolved by code changes made to the upcoming release of our software NX 10. |
6853970 |
Siemens PLM believes that the problem you reported where Stock Style Preferences were changing in Electrical Routing when unrouting and rerouting a cable, will be resolved by code changes made to the upcoming release of our software NX 10. |
6854127 |
Siemens PLM believes that the problem you reported where attribute tittle fails to show in sequential order correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
6860431 |
Siemens PLM believes that the problem you reported where cycling by name does not find some features will be resolved by code changes made to the release of our product NX 10. The documentation for NX 10 has been updated to include information on cycling by names when looking for features. There is also an example that is included in the reference for UF_OBJ_cycle_by_name(). |
6860657 |
Siemens PLM believes that the problem you reported where overstock on Fittings fails when the Thickness attribute is defined as a string will be resolved by code changes made to the release of our product NX version 10. |
6861730 |
Siemens PLM believes that the problem you reported where two fittings that were mated together, using ports in a Part Family Template Assembly, became disassociated when members were created from the Part Family, will be resolved by code changes made to the upcoming release of our software NX 10. |
6863110 |
Siemens PLM believes that the problem you reported where a Parts List cell containing syntax to the object attribute of a component became empty when the assembly was reopened, and the parts list updated, will be resolved by code changes made to the upcoming release of our software NX 10. |
6866514 |
Siemens PLM believes that the problem you reported where the part does not replay/playback consistently will be resolved by code changes made to the release of our software NX 10. Please note that the feature inputs need to be re-selected starting from Split body(15) after an initial replay in NX 10 for a consistent replay/playback. |
6876679 |
Siemens PLM believes that the problem you reported where deleting a flex assembly component raises an internal error and an Undo is performed will be resolved by code changes made to the release of our product NX version 10. |
6877432 |
Siemens PLM believes that the problem you reported where the Routing Bend Radius Table Preference did not work, will be resolved by code changes made to the upcoming release of our software NX 10. |
6880718 |
Siemens PLM believes that the problem you reported where creating a Thread feature raised the error: "Expressions of thread and feature diameters are out of sync", will be resolved by code changes made to the upcoming release of our software NX 10. |
6882568 |
Siemens PLM believes that the problem you reported where Sequential Mill fails to output correct feedrate will be resolved by code changes made to the upcoming release of our software NX 10. Sequential milling will now output non-cutting feedrates correctly instead of outputting them as RAPID motions. The fix for this is in nx10 phase 5, but can be backported to an MP at customer's request. |
6885251 |
Siemens PLM believes that the problem you reported where the Curve collector was not consistent about finding tiny edges will be resolved by code changes made to the upcoming release of our software NX 10. |
6886627 |
quality of 2D plot lines (dash & dotted) is highly dependant on data resolution. |
6887680 |
Siemens PLM believes that the problem you reported where Synchronous Modeling's 'Mirror Face' command creates incorrect geometry will be resolved by code changes made to the upcoming release of our software NX 10. |
6892530 |
Siemens PLM believes that the problem you reported where Undo does not work as expected when a Block Styler application showed a second Block Styler dialog, will be resolved by documentation changes made to the upcoming release of our software NX 10.The page on "Using Undo Marks" has been updated to provide more details specific to this situation. |
6893019 |
Siemens PLM believes that the problem you reported where a part has an empty attribute that can't be deleted, will be resolved by code changes made to the upcoming release of our software NX 10.The inability of interacting with attributes that have empty titles has now been lifted a bit. Using the journaling system, it is possible to delete such attributes. We go to great lengths not to create such attributes, so the UI, UF, GRIP, JA (NXObject) APIs all require that titles be non-empty. To delete an empty-titles attribute: a. Create a journal that deletes a 'normal' attribute. b. Edit the journal to change the title to an empty string. c. Re-run the journal. The attribute should now be gone. This is enabled in release NX 10. |
6893323 |
Siemens PLM believes that the problem you reported where the user can't change the color of an assembly cut face, will be resolved by code changes made to the upcoming release of our software NX 10. |
6893997 |
Siemens PLM believes that the problem you reported where saving an assembly raised the error: "The function FCC_RollbackFileUploadedToPLM() returned the following status: Invalid ticket or invalid ticket pointer.", will be resolved by code changes made to the upcoming release of our software NX 10. |
6895008 |
Siemens PLM believes that the problem you reported where Component Array prevents Routing Mechanical Path commands, will be resolved by code changes made to the upcoming release of our software NX 10. |
6895605 |
Siemens PLM believes that the problem you reported where Items that has a TC required attribute could not be created in NX unless it had a default value will be resolved by code changes made to the upcoming release of our software NX 10. |
6896623 |
Siemens PLM believes that the problem you reported where there was no way to obtain the faces created by an assembly cut operation in NXOpen will be resolved by code changes made to the upcoming release of our software NX 10. |
6897011 |
Siemens PLM believes that the problem you reported where the dialog box of the Simple Measure command changed after Apply, will be resolved by code changes made to the release of our product NX 10. |
6897157 |
Siemens PLM believes that the problem you reported where extra curves were generated when projecting curves to a cylindrical face, will be resolved by code changes made to the upcoming release of our software NX 10. |
6897549 |
Siemens PLM believes that the problem you reported where a Routing path raised an internal error when the part file was opened, will be resolved by code changes made to the upcoming release of our software NX 10. |
6898875 |
Siemens PLM believes that the problem you reported where it was not possible to Wave Link a Surface Offset Port down one level in the assembly, will be resolved by code changes made to the upcoming release of our software NX 10. |
6902425 |
Siemens PLM believes that the problem you reported where an empty Reference Set contains 18-20 objects that cannot be removed will be resolved by code changes made to the upcoming release of our software NX 10.The issue where the Reference Sets dialog cannot be used to remove some members of a Reference Set can be worked around by using a journal to empty the Reference Set contents. The unwanted Reference Set members in this PR appear to have been added as a side effect of creating a sketch while working in the context of the Model Reference Set. In general, creation of geometry while working in context of a Reference Set is the most common cause of unwanted Reference Set members, since the new geometry must be added to the current Reference Set in order to be visible. To avoid this problem, it is recommended to ensure that the work part is displayed with Entire Part when the user is creating geometry. The Assemblies preference "Display as Entire Part" can be used to ensure that this happens automatically whenever the work part is changed. A journal called remove_refset_contents.vb is available from GTAC upon request. The journal contains the string "INSERT_REF_SET_NAME_HERE" which the user must replace with the name of the Reference Set they want to empty. |
6904554 |
Siemens PLM believes that the problem you reported where attributes which were assigned to components priot to NX 8 can no longer be deleted unless the component part is at least partially loaded in the NX session will be resolved by code changes made to the upcoming release of our software NX 10. |
6904965 |
Siemens PLM believes that the problem you reported where PMI Model Views "disappear" after saving part file will be resolved by code changes made to the upcoming release of our software NX 10. |
6908159 |
Siemens PLM believes that the problem you reported where NX is unable to export drawing sheets to PDF will be resolved by code changes made to the upcoming release of our software NX 10. |
6910076 |
Siemens PLM believes that the problem you reported where a PMI balloon caused an Internal Error when loading an assembly, will be resolved by code changes made to the upcoming release of our software NX 10.Note: To clean the existing part please perform the following steps in NX 10: 1) Run File --> Utilities --> Part Cleanup with "Clean Drafting Objects" toggled on. 2) On the drawing, re-inherit the PMI symbols in the view on sheet This can be done by editing view settings and turning off inherited PMI, then after an apply, turning it back to its original setting again. |
6911464 |
Siemens PLM believes that the problem you reported where attempting to Create Component top down is failing with Internal error, will be resolved by code changes made to the upcoming release of our software NX 10. |
6913542 |
Siemens PLM believes that the problem you reported where the NXOpen.Annotations > FcfFrame > ToleranceZoneShape property had not been properly deprecated will be resolved by code changes made to the release of our product NX 10. |
6915032 |
Siemens PLM believes that the problem you reported where missing lines on plot are visible in NX will be resolved by code changes made to the upcoming release of our software NX 10. |
6916518 |
NX Routing Descriptor Characteristics documentation is out of date. |
6916797 |
Siemens PLM believes that the problem you reported where Copy Template as New Design raised a Product Template Explorer warning: "A native drawing cannot be loaded and renamed in managed mode", will be resolved by code changes made to the upcoming release of our software NX 10. |
6917958 |
Siemens PLM believes that the problem you reported where extruding an arc resulted in a spline will be resolved by code changes made to the upcoming release of our software NX 10. |
6920766 |
DUPLICATE OF 6902768 - Wrong results from Offset Curve in Face: Specific example. |
6921830 |
Siemens PLM believes that the problem you reported where using "Move Part" on an Elbow, with disconnect toggled ON, attached 2 small line segments to the end of the existing path rather than extending it, will be resolved by code changes made to the upcoming release of our software NX 10. |
6922947 |
Siemens PLM believes that the problem you reported where the PCOMP maximum principal strain is incorrect for some plies will be resolved by code changes made to the upcoming release of our software NX 10. |
6924937 |
Siemens PLM believes that the problem you reported where the documentation for mqc_askPMIObjectsInformation shows some incorrect values will be resolved by code changes made to the upcoming release of our software NX 10. |
6925229 |
Siemens PLM believes that the problem you reported where the Documentation on the Turning Trim Points Angle options needs more explanation will be resolved by code changes made to the release of our product NX 10. |
6925318 |
Siemens PLM believes that the problem you reported where the Edit Group command were not functioning, will be resolved by code changes made to the upcoming release of our software NX 10. |
6925701 |
There's no drawing templates TAB shown when ugii_lang set to simple_chinese. |
6925975 |
Siemens PLM believes that the problem you reported where rectangle selecting components when doing Edit Explosion selects the entire assembly, will be resolved by code changes made to the upcoming release of our software NX 10. |
6926072 |
Siemens PLM believes that the problem you reported where the user can't copy and paste a feature with a suppression expression, will be resolved by code changes made to the upcoming release of our software NX 10. |
6926620 |
Siemens PLM believes that the problem you reported where "File -> Properties -> Part File (tab) -> File Type" reported "Unknown", will be resolved by code changes made to the upcoming release of our software NX 10.It will now show "None" instead of "Unknown". |
6927086 |
Siemens PLM believes that the problem you reported where the Balloon size was reset after placing balloons using the leader option "Without Stub", will be resolved by code changes made to the upcoming release of our software NX 10. |
6927136 |
Siemens PLM believes that the problem you reported where NX displays OLE server (Switch to... or Retry) dialog on test part file open, will be resolved by code changes made to the upcoming release of our software NX 10. |
6927639 |
Siemens PLM believes that the problem you reported where "Show Connected Lines in Structure Manager across different assemblies will be resolved by code changes made to the upcoming release of our software (both Teamcenter and NX fix): NX 8.5.2 patch(for customer) NX 9.0.1.1 NX v10.1 with: TC v10.1.0.1_e01_1 TC v11.1 |
6927643 |
The default part type which you have specified is not available. |
6927743 |
Siemens PLM believes that the problem you reported where the file - export - simulation command did not obey the performance customer default will be resolved by code changes made to the upcoming release of our software NX 10. |
6928146 |
Siemens PLM believes that the problem you reported where Information > Object on Legacy Surface Finish Symbols returns garbled text, will be resolved by code changes made to the upcoming release of our software NX 10. |
6928752 |
Siemens PLM believes that the problem you reported where when averaging the stresses, the Von Mises stress is all zero will be resolved by code changes made to the upcoming release of our software NX version 10. |
6929122 |
Siemens PLM believes that the problem you reported where part families are failing to create members due to case sensitivity enforcement in attribute naming rule will be resolved by code changes made to the upcoming release of our software NX 10. |
6929451 |
Siemens PLM believes that the problem you reported where the Enable OK/Apply Button callback for the Block Styler dialog was not invoked when the user selected a node in a Tree List will be resolved by code changes made to the upcoming release of our software NX 10. |
6930311 |
Siemens PLM believes that the problem you reported where the documentation does not mention that user-defined cycles are restricted to milling posts is fixed in NX 10 with the addition of the following qualifying statement: User defined cycles are applicable only for hole making operations in mill posts. |
6930743 |
The problem where the environment variable "UGII_ROUTE_UGMANAGER_MODE" was defined incorrectly in two topics in the NX8.5 Documentation, has been fixed in an upcoming release of our software, NX 10. |
6931061 |
A connector direction is not aligned against connected path. |
6931407 |
Siemens PLM believes that the problem you reported where editing the title of one XY plot in the post processor would result in other titles being modified will be resolved by code changes made to the upcoming release of our software NX 10. |
6933791 |
Siemens PLM believes that the problem you reported where editing spsd_deform.xml does not work in NX 8.5 will be resolved by code changes made to the upcoming release of our software NX Stress Wizard, version 10. |
6934209 |
Siemens PLM believes that the problem you reported where Measure Face annotation feature creates incorrect value when the units have been changed will be resolved by code changes made to the upcoming release of our software NX 10. |
6935504 |
Siemens PLM believes that the problem you reported where Uniting two or more promoted bodies will result in the weight calculation of the assembly being incorrect will be resolved by code changes made to the upcoming release of our software NX 10. |
6935519 |
Siemens PLM believes that the problem you reported where 4GD allows geometry construction that can't be saved, will be resolved by code changes made to the upcoming release of our software NX 10. |
6936603 |
Siemens PLM believes that the problem you reported where a chamfer dimension was not created, will be resolved by code changes made to the documentation of our product NX 10.In the NX 10.0 documentation, the Overview topic for Chamfer Dimensions now states the following: When you dimension a chamfered edge that is angled 45 degrees from an adjacent linear edge, no further selections are required. If an adjacent linear edge cannot be detected, then you must either select an adjacent linear edge or manually create the chamfer dimension. |
6937270 |
Siemens PLM believes that the problem you reported where exporting assemblies with part family templates caused performance issues will be resolved by code changes made to the upcoming release of our software NX 10. |
6937696 |
Siemens PLM believes that the problem you reported where an "Internal Error Memory Access Violation" occurred when selecting 'assign corner' will be resolved by code changes made to the upcoming release of our software NX 10. |
6938177 |
Siemens PLM believes that the problem you reported where units are always converted into millimeters upon opening Solidworks files and will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10. |
6938349 |
Siemens PLM believes that the problem you reported where the legacy Open C API function UF_ASSEM_add_ref_set_members was very slow when inappropriate objects such as solid faces and edges were included, will be resolved by code changes made to the upcoming release of our software NX 10. |
6938377 |
Siemens PLM believes that the problem you reported where the first prompt of the Mirror Weld dialog was for a Plane instead of a Point, will be resolved by code changes made to the upcoming release of our software NX 10. |
6939064 |
Siemens PLM believes that the problem you reported where the method for creating and editing section lines associated with section views should be documented will be resolved by code changes made to the release of our product NX 10.The method for creating and editing section lines associated with section views has been redesigned in NX 10. The information was created in NX 10 to describe how to create and edit section lines using the new functionality. |
6939270 |
Siemens PLM believes that the problem you reported where the NX Open VB and C# wizards generated a confusing comment describing automatic execution at startup will be resolved by code changes made to the upcoming release of our software NX 10. |
6939631 |
Siemens PLM believes that the problem you reported where Routing Overstock on a fitting is created as a feature rather than a component when Stock As Component turned ON, will be resolved by code changes made to the upcoming release of our software NX 10. |
6939739 |
Siemens PLM believes that the problem you reported where a wrong value was returned when measuring the distance between a point and a body, will be resolved by code changes made to the upcoming release of our software NX 10. |
6940205 |
Siemens PLM believes that the problem you reported where opening a fem causes a signal 11 error will be resolved by code changes made to the upcoming release of our software NX version 10. |
6940301 |
Siemens PLM believes that the problem you reported where an Internal Error was raised when placing a second instance of a PTS component, added using the Reuse Library, if the GUI was left open, will be resolved by code changes made to the upcoming release of our software NX 10. |
6940826 |
Siemens PLM believes that the problem you reported where UF_CURVE_ask_conic_data returns values that do not work with the Edit function will be resolved by code changes made to the upcoming release of our software NX 10. |
6940944 |
Siemens PLM believes that the problem you reported where it was not possible to apply a revised stock template to replace existing stock on a path, will be resolved by code changes made to the upcoming release of our software NX 10. |
6940946 |
Siemens PLM believes that the problem you reported where the user experienced performance issues while scrolling through the Quickpick list, will be resolved by code changes made to the upcoming release of our software NX 10. |
6941369 |
PS27.0.58 Specific Variable Radius Face Blend won't trim and sew to target. |
6941390 |
Out of sequence timestamp order after feature replace. |
6941753 |
Siemens PLM believes that the problem you reported where you were unable to import step 214:Unhandled UG exception caught will be resolved by code changes made to the upcoming release of our software NX 10. Parasolid file was send back to the customer per his request. No CRR needed. |
6941773 |
Siemens PLM believes that the problem you reported where cell format changing in title block will be resolved by code changes made to the upcoming release of our software NX 10. |
6941907 |
Offset curve in face fails if Trim to each other is ON (OK if OFF). |
6941936 |
Cannot achieve correct Offset in Face curve. |
6941963 |
Out of tolerance Offset Curve in Face w/Quintic; no warnings. |
6942274 |
Can't constrain Bridge Curve to Body Faces. |
6942386 |
Siemens PLM believes that the problem you reported where the Create Linear Path using Infer Point and then Specify Point fails to select a Port will be resolved by code changes made to the upcoming release of our software NX 10. |
6942413 |
PS27.00.108: Intersection Point fails after unrelated edit/update. |
6943087 |
Siemens PLM believes that the problem you reported where export to pdf causes issues to broken view annotation, will be resolved by code changes made to the upcoming release of our software NX 10. |
6943110 |
Group does not display object name for plane. |
6943128 |
Offset curve in face fails to remove self-intersection correctly. |
6944507 |
Siemens PLM believes that the problem you reported where Speed and Feed values are not being updating when two fields are edited followed by pressing OK will be resolved by code changes made to the upcoming release of our software NX 10. |
6944626 |
The problem where users cannot specify the 'path' property of a NativeFileBrowser Block Styler dialog object in NX Open is fixed in NX 10. The documentation will now make it more clear that the string passed in must include the full specification of a file, not just the folders in which it is stored. |
6944653 |
Siemens PLM believes that the problem you reported where Sequential Mill fails to output feedrates correctly will be resolved by code changes made to the upcoming release of our software NX 10. Sequential milling will now output non-cutting feedrates correctly instead of outputting them as RAPID motions. The fix for this is in NX 10 phase 5, but can be backported to an MP at customer's request. |
6944664 |
Siemens PLM believes that the problem you reported where the Vector at Routing Path Point was not honored or retained with "0" length for extensions, will be resolved by documentation changes made to the upcoming release of our software NX 10. The documentation was updated to note that Splines will only be tangent at the ends if the extension has a non-zero value for either the Forward or Back Extension. A zero for both represents no tangency. |
6944721 |
Siemens PLM believes that the problem you reported where the NXOpen.Features > AdmOffsetRegionBuilder methods Commit, CommitFeature, and GetFeature did not return the newly created Offset Region feature will be resolved by code changes made to the upcoming release of our software NX 10. |
6945328 |
Siemens PLM believes that the problem you reported where Simple Radius or Simple Diameter measure shows incorrect options in the dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
6946221 |
Siemens PLM believes that the problem you reported where grid point forces are not imported correctly will be resolved by code changes made to the upcoming release of our software NX version 10. |
6946339 |
Siemens PLM believes that the problem you reported where the NX Routing Systems documentation did not explain what the PART_NAME column in a PTB file maps to in Teamcenter, will be resolved by documentation changes made to the release of our product NX 10. |
6946377 |
Siemens PLM believes that the problem you reported where updating a parent view hid a Detail View Label if Delay View Update was turned off, will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 10. |
6946957 |
Siemens PLM believes that the problem you reported where "unable to see component properties in TC Vis" will be resolved by code changes made to the upcoming release of our software, NX Version 9.0.1 and 10. |
6947047 |
Siemens PLM believes that the problem you reported where Updating a parent view hid the Detail View Label if Delay View Update was turned off, will be resolved by code changes made to the upcoming release of our software NX 9.0.3 and NX 10.0.1. |
6950081 |
Siemens PLM believes that the problem you reported where Overflow region option gives unexpected results will be resolved by code changes made to the release of our product NX version 10 by updating the Documentation on this subject. The documentation for the Continuation option in the Template Region dialog box has been updated with descriptions for the different options. The New Sheet Right option now has the following description: "A new sheet is created and the overflow content is placed in an equivalent region at the same location on the new sheet. Any additional overflow is placed in a new region of an equivalent size created to the right of the existing region." Similar information has been added for all the other options. |
6950148 |
Siemens PLM believes that the problem you reported where while importing simulation entities from another .sim file, the prepend string field is filled with the default string even when this field is left blank will be resolved by code changes made to the upcoming release of our software NX 10. "From now on if the field "String to prepend simulation entity names" is left blank, then no default string will prepend. Trailing blank spaces in the prepend string will be removed as well." |
6950326 |
Siemens PLM believes that the problem you reported where When turning off Tolerant Machining user gets a warning about faceted bodies will be resolved by documentation changes made to the upcoming release of our software NX 10.We have added additional information about the use of Blank geometry when Tolerant Machining is turned off to the CAM--> Mfg Milling--> Path Settings--> Cutting Parameters Dialog Box--> More tab--> Legacy group--> (Tolerant Machining off) section of the docs.. |
6950730 |
Siemens PLM believes that the problem you reported where turning on Load Interpart Data and opening a routing assembly into 4GD causes the loss of the Routing Control Points will be resolved by code changes made to the release of our software NX 8.5.2 MP6, NX 8.5.3 MP5, and NX 10. |
6950938 |
Siemens PLM believes that the problem you reported where the NXOpen.UF > UFDrf > AskIdSymbolInfo (wrapper for UF_DRF_ask_id_symbol_info) crashed NX when used on an ID Symbol which has multiple leaders will be resolved by code changes made to the upcoming release of our software NX 10. |
6950950 |
Siemens PLM believes that the problem you reported where Offset Curve in Face returned partial results with "Trim to Each Other within Section", will be resolved by code changes made to the upcoming release of our software NX 10. |
6950956 |
Siemens PLM believes that the problem you reported where opening a Parasolid Transmit file in NX raised the error "An attempt was made to create a cyclic assembly structure", will be resolved by code changes made to the upcoming release of our software NX 10. |
6951797 |
This PR has been reviewed by development. Due to the low priority of the problem and the length of time the current behavior has been in the system we do not intend to fix this PR. If the problem is still impacting your day to day operation as you use the NX product, please contact GTAC to have the PR reopened. |
6951891 |
Siemens PLM believes that the problem you reported where there was no freeing function for the data structure used by UF_MODL_ask_symb_thread_parms() will be resolved by code changes made to the upcoming release of our software NX 10. |
6951942 |
Siemens PLM believes that the problem you reported where NXOpen Java required the first jar in a chain to be signed, even if it did not contain any NXOpen calls, will be resolved by code changes made to the upcoming release of our software NX 10. |
6952030 |
*** Date & Time: 22-nov-2013 08:35:37 User: BRUEGGE, OLIVER (bruegge) *** The part file is 'No Export', but Problem could be solved by coordinator. *** Date & Time: 22-nov-2013 08:35:37 User: Tue Doan) *** I've worked with the user and resolve the problem. No PR is needed and the user had request to have this PR closed. No letter is needed for this. |
6952727 |
Siemens PLM believes that the problem you reported where NX crashes during drawing export to DXF will be resolved by code changes made to the upcoming release of our software NX 8.5.2 and NX 10. |
6952729 |
Siemens PLM believes that the problem you reported where part of curve does not get offset when using Offset in Face, will be resolved by code changes made to the upcoming release of our software NX 10.The code change has been 'algorithm version' and the Offset in Face feature must be recreated to observe the fix. |
6953486 |
Siemens PLM believes that the problem you reported where the documentation for the GetArbitraryNoteTitle did not explain that it will not return any values unless the corresponding method SetArbitraryNoteTitle has been used first will be resolved by documentation changes made to the release of our product NX 10. |
6953788 |
Siemens PLM believes that the problem you reported where Simple Radius and Simple Diameter show wrong dialog when Inch file loaded will be resolved by code changes made to the upcoming release of our software NX 10. |
6953972 |
Siemens PLM believes that the problem you reported where the PMI custom symbol text scale increases when moving a stacked custom symbol will be resolved by code changes made to the upcoming release of our software NX 10. |
6954424 |
Siemens PLM believes that the problem you reported where there was a Null tag error when editing a deformable component, will be resolved by code changes made to the upcoming release of our software NX 10. The problem where an exception occurs during edit deform is fixed in NX 10. The fix is risky and the development team does not feel that it is appropriate to move this fix back to an NX 8.5.x MP. Once the fix has been through appropriate testing and evaluation in the latest release being developed, the development team will evaluate if the fix can be moved back, possibly to some maintenance release of NX9. Please consider using the following work around: instead of editing the deform instantiation, delete and recreate deform instantiation. |
6955048 |
Siemens PLM believes that the problem you reported where nodes can not be added to a group by label will be resolved by code changes made to the upcoming release of our software NX version 10. |
6955553 |
Siemens PLM believes that the problem you reported where updating a drawing view raised an Internal Error, will be resolved by code changes made to the upcoming release of our software NX 10. |
6956222 |
Siemens PLM believes that the problem you reported where Edit Line Segment deleted overstock, will be resolved by code changes made to the upcoming release of our software NX 10. |
6956888 |
Siemens PLM believes that the problem you reported where un-pre-selecting can be sluggish when groups and or components are involved in the pre-selection, will be resolved by code changes made to the upcoming release of our software NX 10. No fixes to earlier NX versions are yet planned but currently under consideration. |
6957100 |
Siemens PLM believes that the problem you reported where there is an issue post processing moments will be resolved by code changes made to the upcoming release of our software NX version 10. |
6958147 |
Siemens PLM believes that the problem you reported where PMI datum symbols move when attached in a LightWeight Section view, will be resolved by code changes made to the upcoming release of our software NX 10. |
6958519 |
Siemens PLM believes that the problem you reported where custom symbol install chooses wrong TC instance, will be resolved by code changes made to the upcoming release of our software NX 10. |
6958614 |
Siemens PLM believes that the problem you reported where there is a Documentation error in the Machine Control section will be resolved by changes made to the documentation in the upcoming release of our software in NX 10. A documentation caveat has also been added to NX 9.0.1. |
6959329 |
Siemens PLM believes that the problem you reported where a Face to Face blend failed if selection intent was set to Body Faces or Tangent Faces, but worked if intent was set to Single Face, will be resolved by code changes made to the upcoming release of our software NX 10. |
6959358 |
Siemens PLM believes that the problem you reported where section in the documentation with the Part Families was incorrect regarding the ability to edit Component Parameters at the Assembly Level, will be resolved by code changes made to the upcoming release of our software NX 10.We have reinstated the section header "Part Family Members and parameterization" immediately before the paragraph referring to the editing of assembly components created from a part family member. This header was inadvertently lost during one of the documentation conversions of the last 10 years, and caused this paragraph to become out of context and confusing to the reader. Also replaced all instances of "family of parts" with "part family" throughout the section on Part Families. Note that only the Part Families section in the Modeling Help has been updated with these changes. The problem described in this PR could not be found in the Assemblies Help. |
6959979 |
Siemens PLM believes that the problem you reported where Trim/Extend Make Corner Fails to trim a corner with the Law Extension Length value at a specific value. "5.00" fails, but "4.99" works, will be resolved by code changes made to the release of our software NX 10.Please update the feature to see the changes. |
6960075 |
Siemens PLM believes that the problem you reported where a port is not re-displayed when part is deleted will be resolved by code changes made to the release of our software NX 10. |
6960389 |
Siemens PLM believes that the problem you reported where Mold Flow analysis result overlaps wall thickness result will be resolved by code changes made to the upcoming release of our software NX 10, NX 9.0.2 |
6960390 |
The problem where ______________ {GTAC describes issue here} has been investigated and the following has been found. |
6961219 |
Siemens PLM believes that the problem you reported where "Stock Not Found" error was raised using Autoroute from the Connection Navigator, will be resolved by code changes made to the upcoming release of our software NX 10. |
6961355 |
Siemens PLM believes that the problem you reported where Routing returned the error: "Gaps in string or multiple loops" during feature update, will be resolved by code changes made to the upcoming release of our software NX 10. |
6961689 |
Siemens PLM believes that the problem you reported where the checkbox options are not honored in Information Advanced Simulation> Node/Element when some options are unchecked, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 10. |
6961949 |
Siemens PLM believes that the problem you reported where Memory access violation received to delete deformable component will be resolved by code changes made to the upcoming release of our software NX 10. The part has some corrupt data related to external references of deform instantiation. It is not clear how the part has reached into this corrupt state. However NX 10 is modified to gracefully handle corrupt data and lets user delete, create and edit deform. In NX 7.5, the parts are repaired and can be returned to you per your request. The user can use the repaired parts to create, delete and edit deform operations properly. |
6962226 |
Siemens PLM believes that the problem you reported where NX8.5 and NX9 do not import solid laminate ply and material data from Ansys .cdb file will be resolved by code changes made to the upcoming release of our software NX 10. |
6962477 |
Siemens PLM believes that the problem you reported where an incorrect color palette was used when creating new Formboard drawings, will be resolved by code changes made to the upcoming release of our software NX 10. |
6962607 |
Siemens PLM believes that the problem you reported where the documentation on coordinate systems used with FE creation was not clear will be resolved by code changes made to the release of our product NX 10. |
6962745 |
Siemens PLM believes that the problem you reported where CTE calculations are incorrect, will be resolved by code changes made to the upcoming release of our software NX 10. |
6963276 |
Siemens PLM believes that the problem you reported where there is an inconsistent browser display depending upon selection order will be resolved by code changes made to the upcoming release of our software NX 10. |
6964263 |
Siemens PLM believes that the problem you reported where "Load Interpart Data: All Levels" works, but failing to set it causes the components to not display, will be resolved by code changes made to the upcoming release of our software NX 10. |
6964385 |
Siemens PLM believes that the problem you reported where the Menuscript and Toolbar documentation did not explain how to pass arguments to an NXOpen API application or journal being invoked from a new button will be resolved by documentation changes made to the upcoming release of our software NX 10. |
6964495 |
Siemens PLM believes that the problem you reported where Heal Path did not get created on the correct planes, using the YC ZC XC method, will be resolved by code changes made to the release of our product NX 10. |
6965510 |
Siemens PLM believes that the problem you reported where the element copy and reflect command created new collectors will be resolved by code changes made to the upcoming release of our software NX 10. |
6965687 |
Siemens PLM believes that the problem you reported where the information provided in the Programming Tools documentation did not specifically state where to find the information on the supported compiler version will be resolved by documentation changes made to the upcoming release of our software NX 10. |
6966086 |
Siemens PLM believes that the problem you reported where for SOL 601,129 and setting the initial conditions with a local coordinate system, the arrow display was incorrect will be resolved by code changes made to the release of our product NX version 10. |
6966822 |
Siemens PLM believes that the problem you reported where the Reflect Element function creates new collectors for each reflected mesh will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 10.. |
6966979 |
Siemens PLM believes that the problem you reported where Position Independent Linked Points will not update to new inputs after rel-inking, will be resolved by code changes made to the upcoming release of our software NX 10. |
6968073 |
Siemens PLM believes that the problem you reported where hex meshing failed will be resolved by code changes made to the upcoming release of our software NX version 10. |
6968443 |
Siemens PLM believes that the problem you reported where SolidWorks switches units when opened in NX will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10. |
6968711 |
Siemens PLM believes that the problem you reported where there errors importing the I-deas symbol file will be resolved by code changes made to the upcoming release of our software NX 10. |
6968733 |
Siemens PLM believes that the problem you reported where the Expression Type changes from Pressure to Fatigue Strength Coefficient when the expression is created, will be resolved by code changes made to the upcoming release of our software NX 10. |
6968807 |
Siemens PLM believes that the problem you reported where a POST action assigned to the button or UG_PMI_EDIT_DIMENSION does not run will be resolved by code changes made to the upcoming release of our software NX 10. |
6968835 |
Siemens PLM believes that the problem you reported where a Menuscript-defined post actin for UG_DRAFT_DRW_UPDATE_VIEW does not work will be resolved by code changes made to the upcoming release of our software NX 10. |
6969427 |
Siemens PLM believes that the problem you reported where 3 Point arc flips when editing it in dialog vs. Details tab will be resolved by code changes made to the upcoming release of our software NX 10. |
6969965 |
Siemens PLM believes that the problem you reported where Title block show default value AND defined attribute formula removed issues (derived from PR#6908363 fix) will be resolved by code changes made to the upcoming release of our software NX 10. |
6971074 |
Siemens PLM believes that the problem you reported where the <RBM>List References utility option of the Tools-> Expressions dialog did not show points controlled by expressions will be resolved by code changes made to the upcoming release of our software NX 10. NX 10 will show the class, address and tag of the smart object controlled by the scalar rather than the scalar itself. Since the point in this scenario is listed under Unused Items (non associative features), we can display only the class, address and tag of such entities. |
6971897 |
Siemens PLM believes that the problem you reported where CAM reports two different "Shortest Tool" values will be resolved by code changes made to the upcoming release of our software NX 10. |
6972286 |
Siemens PLM believes that the problem you reported where editing a Sequential Mill Feedrate changes the values stored in the Method will be resolved by code changes made to the upcoming release of our software NX 10. |
6972848 |
Siemens PLM believes that the problem you reported where adding multiple components from a Part Family Template raised the message: "Incorrect object for this operation", will be resolved by code changes made to the upcoming release of our software NX 10. |
6973711 |
Siemens PLM believes that the problem you reported where if set "Boolean face Properties" as Tool Body: can't update Trim & Split faces will be resolved by code changes made to the release of our product NX 10. |
6973893 |
Siemens PLM believes that the problem you reported where the Face Annotation of a connector is not working will be resolved by code changes made to the release of our product NX 10. |
6973936 |
Siemens PLM believes that the problem you reported where object selection methods, such as NXOpen > Selection > SelectTaggedObject, failed when remoting from an external client application into an interactive NX session, was found to be caused by the failure of the server to export the UI object for use by the client. Since the need for this was not obvious, the documentation has been fixed to explain it for the upcoming release of our software NX 10. |
6974313 |
Siemens PLM believes that the problem you reported where shading of a detail view did not appear correct at Higher resolution will be resolved by code changes made to the release of our product NX 10. |
6975419 |
Siemens PLM believes that the problem you reported where Symbolic threads are not rendering properly unless the hidden line option is changed will be resolved by code changes made to the release of our software NX 10. |
6975480 |
Siemens PLM believes that the problem you reported where the Component Pattern Journaling class wrote error messages in the NX log file will be resolved by code changes made to the upcoming release of our software NX 10. |
6976113 |
Siemens PLM believes that the problem you reported where Dimensions associated to extracted edges in a Section View became retained when updating the view, will be resolved by code changes made to the upcoming release of our software NX 10. |
6976522 |
Siemens PLM believes that the problem you reported where results measure when using a results set containing companion results returns errors will be resolved by code changes made to the upcoming release of our software NX 10. |
6977416 |
Siemens PLM believes that the problem you reported where the WCS Orient option is no longer available from within Verify 3D Dynamic will be resolved by code changes made to the release of our product NX 9.0.3 MP1 and NX 10. |
6977831 |
Siemens PLM believes that the problem you reported where an "Invalid Annotation Text" error is raised when importing an I-deas symbol file will be resolved by code changes made to the upcoming release of our software NX 10. |
6977834 |
Siemens PLM believes that the problem you reported where the Layer Setting Information Window incorrectly displays the Category Description will be resolved by code changes made to the upcoming release of our software NX 10. |
6978133 |
Siemens PLM believes that the problem you reported where editing a note in a read-only file caused the note to be copied and placed outside the drawing border, will be resolved by code changes made to the upcoming release of our software NX 10. |
6979662 |
Siemens PLM believes that the problem you reported where the Knowledge Fusion Help and Best Practices guide needs to provide more information on the use of the Suppress? attribute when using the nx_application class will be resolved by code changes made to the upcoming release of our software NX 10. |
6979968 |
Siemens PLM believes that the problem you reported where it is not possible to Divide a VoluMill operation tool path by time will be resolved by code changes made to the upcoming release of our software NX 10. |
6980216 |
Siemens PLM believes that the problem you reported where the NX Documentation on moving operations in Synchronization Manager was not correct will be resolved by code changes made to the upcoming release of our software NX 10. |
6980254 |
Siemens PLM believes that the problem you reported where values of W3 and W4 are not exported correctly for rotor entities will be resolved by code changes made to the upcoming release of our software NX 10. |
6980578 |
Siemens PLM believes that the problem you reported where Maintain Work Part, (in Customer Defaults -> Assemblies), fails to work in NX9 will be resolved by code changes made to the upcoming release of our software NX 10. From NX 10 onwards the Assemblies Preferences: Maintain Work Part Display As Entire Part Warn on Automatic Change Display Update Report Component Member Select will no longer store their value in the NX registry. This means that the initial value of these preferences in the NX session will be determined by the corresponding Assemblies customer default. The Assemblies Preferences can still be used to change these settings within the NX session, but the next time the NX session is started again these values will again be initialized from the customer defaults. Since this is a change in behavior, this fix will not be back ported to any earlier releases. For releases prior to NX 10 it is necessary to change the Assemblies Preference values in order for these options to persist across NX sessions. |
6982433 |
Siemens PLM believes that the problem you reported where the callback registered using the method NXOpen > PartCollection > AddPartSavedHandler was unexpectedly invoked when the user selected Edit -> Copy or <Ctrl> C after selecting a tabular note, or other non-feature object, will be resolved by code changes made to the upcoming release of our software NX 10. |
6984062 |
Siemens PLM believes that the problem you reported where updating the value for DB_PART_NAME in the part family spreadsheet in NX did not update the values in Teamcenter, nor the value in existing members, will be resolved by code changes made to the upcoming release of our software NX 10.The issue has been resolved by giving user a feedback in the form of a pop up message mentioning the names of all locked attributes and the fact that they are locked, hence, their values cannot be updated. It would have the behavior as follows: 1. This message would pop up only once whether one or multiple members are selected for update from part family spreadsheet. 2. This message would pop up irrespective of whether user tried to update the value of any locked attribute or not. 3. If user tried to modify the value of locked attributes, their values are not undone (i.e. reverted back to the old value). Hence, part family spreadsheet would get saved with the new value. User should then change their values back to the previous value manually. This behavior is in line with Expressions attributes, where an expression value although invalid, gets saved in spreadsheet. |
6984850 |
Siemens PLM believes that the problem you reported where an error occurred when editing a booklet with an item type containing the Hide Business Object Rule set to "is True", will be resolved by code changes made to the upcoming release of our software NX 10.Going forward, these item types are editable, however, booklets are not permitted to be created from these types and an error message will be displayed if the user does not have display access. |
6984862 |
Siemens PLM believes that the problem you reported where Checkmate crashed in batch mode using NX 8.5.3 mp1, will be resolved by code changes made to the upcoming release of our software NX 10. |
6985087 |
Siemens PLM believes that the problem you reported where parts with features applied to stock features fail to open will be resolved by code changes made to the upcoming release of our software NX 9.0.1, NX 10.0, and MPs of NX8.5.2 & NX8.5.3. |
6985383 |
Siemens PLM believes that the problem you reported where for rigid elements when using the option RIGID=LAGRAN, it was not possible to import OP2 results will be resolved by code changes made to the upcoming release of our software NX 10. |
6985956 |
Siemens PLM believes that the problem you reported where Ignores stop position point while profiling will be resolved by code changes made to the upcoming release of our software NX 10. |
6987637 |
Siemens PLM believes that the problem you reported where Count" was not fully defined in the 'Pattern Feature' command's Help docs, will be resolved by code changes made to the upcoming release of our documentation NX 10. In the "Common pattern definition options" topic, changed the following text: Count From: ---- Sets the number of instances to be created in the pattern when Spacing is set to one of the following: To this: ------- Sets the number of instances (including the origin object) for the pattern. Available when Spacing is set to one of the following: |
6988414 |
Siemens PLM believes that the problem you reported where expanding and collapsing the classes in the selection popup of the MKE Rule View closes the popup will be resolved by code changes made to the upcoming release of our software NX 10. |
6989511 |
Siemens PLM believes that the problem you reported where setting Feeds and Speeds causes an operation to go out-of-date will be resolved by code changes made to the release of our product NX 10. The NX Help documentation has been altered to better explain this. |
6989723 |
Siemens PLM believes that the problem you reported where overstock density was not documented in the Routing TDOC will be resolved by code changes made to the release of our product NX version 10. |
6989779 |
Siemens PLM believes that the problem you reported where the datum plane created with line through point and normal to curve, fails to update will be resolved by code changes made to the upcoming release of our software NX 10. |
6990135 |
Siemens PLM believes that the problem you reported where MQC_askentitiesinreferenceset reports differently in NX8.5.1 versus NX5 will be resolved by code changes made to the upcoming release of our software NX 10. |
6990767 |
Siemens PLM believes that the problem you reported where JT export associativity lost causing downstream wavelink features to break will be resolved by code changes made to the upcoming release of our software NX 10. |
6991548 |
Siemens PLM believes that the problem you reported where you can lock the Area but still change the Diameter of the Circular Duct, will be resolved by code changes made to the upcoming release of our software NX 10. |
6991905 |
Siemens PLM believes that the problem you reported where user is unable to import assembly, default part type is not available(PR6953356) will be resolved by code changes made to the release of our product NX version 10. This version supports Items with required properties defined in Teamcenter without any special setting required. |
6992457 |
Siemens PLM believes that the problem you reported where "Help on Context" for Feeds and Speeds does not contain some Milling-specific information will be resolved by code changes made to the upcoming release of our software NX 10. |
6993386 |
Siemens PLM believes that the problem you reported where material usage may incorrectly be reported as unused will be resolved by code changes made to the upcoming release of our software in NX 10. |
6993916 |
Siemens PLM believes that the problem you reported where 'Load All Defaults' not pulling drafting standard defined unit will be resolved by code changes made to the upcoming release of our software NX 10. |
6994367 |
Siemens PLM believes that the problem you reported where the post-processing system template named Absolute_Deformation_Scale_One does not scale correctly will be resolved by code changes made to the upcoming release of our software NX 10. |
6995014 |
Siemens PLM believes that the problem you reported where it was not possible to de-select Guide Curve edges while creating a Weld Point in a component while it was the Work Part in context of an assembly, will be resolved by code changes made to the upcoming release of our software NX 10.This issue can be resolved by pressing "Select Curve" in the dialog, instead of middle mouse button. This is fully resolved in NX 10 in the Weld Point Wizard command. |
6995048 |
Siemens PLM believes that the problem you reported where the units of a Solidworks file are always converted to Metric when opened in NX, will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10. |
6995290 |
Siemens PLM believes that the problem you reported where the message "A deleted or invalid class id was used" was displayed while saving a part file will be resolved by code changes made to the upcoming release of our software NX 10. |
6998648 |
Siemens PLM believes that the problem you reported where a Symbolic Thread is not displayed correctly when set to Ansi Symplified, will be resolved by code changes made to the release of our software NX 10. |
6999257 |
Siemens PLM believes that the problem you reported where you could not select material orientation in post even though the elements have a MCSYS will be resolved by code changes made to the release of our software NX 10. |
7001396 |
The problem where no information is provided in the Drafting Help about the fact that Annotation Templates contain multiple drawing sheets is fixed in NX 10.The following note was added to overview information about Annotation Templates: "Template files provided with NX contain multiple drawing sheets. If you customize these files, make sure you apply your modifications to all of the drawing sheets in the template file." |
7100666 |
Siemens PLM believes that the problem you reported where Inherit Clipping Boundary does not work with Lightweight Section Views will be resolved by code changes made to the upcoming release of our software NX 10. |
7101209 |
Siemens PLM believes that the problem you reported where a SolidWorks part file was converted into metric (SI) units only will be resolved by code changes made to the upcoming release of our software NX 9.0.2 and NX 10. Unit information from the original SolidWorks file cannot be determined when converting into an NX part file. The measurement units specified in 'Customer Default -> Gateway -> General -> Part Default Units' should be used when a conversion is done. This was not working and has been fixed. |
7101737 |
Siemens PLM believes that the problem you reported where opening a SolidWorks assembly file raises the error "PLMXML document contains no part" will be resolved by code changes made to the upcoming release of our software NX 10. |
7101897 |
Siemens PLM believes that the problem you reported where the Ansys translator has invalid MPC184 for bolted connection will be resolved by code changes made to the upcoming release of our software NX version 10.0. |
7102487 |
Siemens PLM believes that the problem you reported where the Docs need a note to include the ability to select a single point in 'Point Set will be resolved by code changes made to the upcoming release of our software in NX 10. |
7104285 |
Siemens PLM believes that the problem you reported where a duplication of Assembly Constraints are created when using Positioning Overrides will be resolved by code changes made to the upcoming release of our software NX 10. |
7104374 |
Siemens PLM believes that the problem you reported where the NX Help Documentation does not clearly explain the Rotary Milling floor rotational axis will be resolved by code changes made to the upcoming release of our software NX 10. |
7105516 |
The problem where ejector pins were not trimmed to the entered length has been corrected for NX 10 with documentation implementation. The following text has been added to the Ejector Pin Post Processing dialog box: "The Ejector Pin Post Processing command trims the pin body from the standard catalog length to the finished length used in the mold. This length includes an offset value, if you specify one. The BOM displays the standard catalog length of the pin." |
7105701 |
Siemens PLM believes that the problem you reported where a Rapid Dimension locked the NX session in NX 9.0.1, will be resolved by code changes made to the release of our product NX 10. |
7106487 |
Siemens PLM believes that the problem you reported where a Syntax Error was raised when editing the Diameter Expression of Boss feature to make it constant, will be resolved by code changes made to the upcoming release of our software NX 10. |
7106965 |
Siemens PLM believes that the problem you reported where Specify Stock had to be re-selected on the Stock dialog, when assigning new PTS stock to a new path, to inherit the Duct Size values, will be resolved by code changes made to the release of our product NX 10. |
7107340 |
Siemens PLM believes that the problem you reported where the NXOpen NXObjectManager.hxx header file contains the classes (NXObjectBuilder and TransientObjectBuilder) and methods on the NXObjectManager class (SetSingletonTag, Construct, and registerBuilder) which are not intended to be used in customer applications will be resolved by code changes made to the release of our product NX 10. The methods which are internal only have been marked as deprecated have been hidden using a macro to help discourage their usage. To continue using them prior to their removal in NX12 an application will need to #define USE_UNSUPPORTED_BUILDER. |
7107738 |
Siemens PLM believes that the problem you reported where the Assembly Clearance value is measuring from one end of the part to the other will be resolved by code changes made to the release of our product NX 10. |
7107903 |
Siemens PLM believes that the problem you reported where additional information about step 8 in the NX Help document, "Create a new family of parts" will be resolved by code changes made to the upcoming release of our software NX 10.The option in step 4 in this same document is correct and should be 'Exportable Part Family Template' as displayed in the UI. |
7108207 |
Siemens PLM believes that the problem you reported where specific version rules lock up NX when creating an FEM and SIM will be resolved by code changes made to the upcoming release of our software in NX Advanced Simulation, version 10. Development indicated that a warning will be made to change the customer default setting if the auto-generated name is not compatible with the version rule. |
7108236 |
Siemens PLM believes that the problem you reported where the graph title changes as entites are selected will be resolved by code changes made to the upcoming release of our software NX 10. |
7108504 |
Siemens PLM believes that the problem you reported where Sum, and hence the average, reported by the 'Identify' command is not accurate will be resolved by code changes made to the upcoming release of our software NX 10. Incorrect values are getting reported as a result of rounding off error. |
7108534 |
Siemens PLM believes that the problem you reported where Part Cleanup deletes a suppressed pattern feature in a component will be resolved by code changes made to the upcoming release of our software NX 10. |
7108890 |
Siemens PLM believes that the problem you reported where the Block Styler documentation regarding changing the displayed part needed to provide more information will be resolved by documentation changes made to the upcoming release of our software NX 10. |
7109653 |
Siemens PLM believes that the problem you reported where PMI import from a STEP file causes the 'Fit' to zoom out to include absolute 0,0,0, even though nothing is there at 0,0,0 will be resolved by code changes made to the upcoming release of our software NX 10. |
7109789 |
Siemens PLM believes that the problem you reported where the Open C API header file uf_modl.h is missing the History information for the function UF_MODL_is_browseable_feature will be resolved by code changes made to the upcoming release of our software NX 10. |
7111379 |
Siemens PLM believes that the problem you reported where an Angular Dimension to 2D Centerlines always produced the complement angle, rather than the desired angle, will be resolved by code changes made to the release of our product NX 10. |
7111804 |
Siemens PLM believes that the problem you reported where ug_inspect utility reports object type 59 incorrectly will be resolved by code changes made to the upcoming release of our software NX 10. |
7112089 |
Siemens PLM believes that the problem you reported where NX8.5.3 does not recognize item types with required properties in Tc 10.1, will be resolved by code changes made to the upcoming release of our software NX 10. NX now supports Items with required properties defined in Teamcenter without any special settings required. |
7112699 |
Siemens PLM believes that the problem you reported where "no write access" on native parts while loading an assembly occurs, will be resolved by code changes made to the upcoming release of our software NX 10. The message you will get instead for these sort of system errors on trying to read parts should now be "no read access". The precise reason of all the many Windows errors will also be printed to the syslog (as a number) so it can be worked out if necessary - this should be a bit more helpful and less confusing than mentioning "no write access". |
7112741 |
Siemens PLM believes that the problem you reported where the Knowledge Fusion documentation did not explain that the menu option Tools-> Knowledge Fusion-> Remove all Rules will not remove instances of *system* classes which inherit from %nx_application or %ug_create_instance will be resolved by documentation changes made to the upcoming release of our software NX 10. |
7112807 |
The problem where TCIN SOA errors in case of NX with non-4GD database is fixed in release NX 10. |
7113407 |
Siemens PLM believes that the problem you reported where cloning a motion file resets the Item Name and Description in the database will be resolved by code changes made to the upcoming release of our software NX Motion Simulation, version 10. |
7113510 |
Siemens PLM believes that the problem you reported where there was performance issue when remove spline path point on legacy assembly will be resolved by code changes made to the release of our product NX version 10. |
7114821 |
Siemens PLM believes that the problem you reported where Route Paths became distorted when exporting or removing components, will be resolved by code changes made to the release of our product NX 10. |
7115060 |
Siemens PLM believes that the problem you reported where a Macro controlling the state of the NX UI from Ribbon to Classic Toolbar did not work, will be resolved by code changes made to the upcoming release of our software NX 10. |
7115654 |
Siemens PLM believes that the problem you reported where Routing Run Navigator is not consistently assigning RUN_ID for Routing objects will be resolved by code changes made to the release of our product NX v10. |
7116404 |
Siemens PLM believes that the problem you reported where Offset Curve in Face produced the wrong result using the Extend to Face Edges option, will be resolved by code changes made to the upcoming release of our software NX 10. |
7116502 |
Siemens PLM believes that the problem you reported where Checkmate test results to part family members from folder TCIN will be resolved by code changes made to the release of our product NX version 10.. This was a problem where the Check-Mate Help Documentation needed to explain that when user set up tests in Teamcenter using the All Parts in Folder option, the parts that are listed in that folder depend on the Revision Rule assembly load option setting, is fixed in Help Documentation for NX 10. |
7117074 |
Siemens PLM believes that the problem you reported where File-> Open does not open the correct file name, will be resolved by code changes made to the upcoming release of our software NX 10.This part has a value of DB_PART_NO cached in a slightly unexpected way. The system has been fixed to cope with this state in such a way that it will not show up in the user interface. There is no known workaround at present. |
7117217 |
Siemens PLM believes that the problem you reported where Copy/Paste sketch with pattern curve displays incorrect curve pattern will be resolved by code changes made to the upcoming release of our software NX 10. |
7117256 |
Siemens PLM believes that the problem you reported where Refile reports the wrong file name when there is a failure. will be resolved by code changes made to the upcoming release of our software NX 10. |
7117371 |
Siemens PLM believes that the problem you reported where in 'Tilt tool axis' the user is getting the message "Tool Path cannot be generated" will be resolved by code changes made to the upcoming release of our software NX 10.Attempting to use the tilt tool axis option will now produce an error if there is no part geometry specified in the operation. |
7117386 |
Siemens PLM believes that the problem you reported where the documentation page titled: "Create a .bmp file for a toolbar icon" needed updating, will be resolved by documentation changes made to the upcoming release of our software NX 10. |
7118539 |
Siemens PLM believes that the problem you reported where methods on the API class NXOpen > Rulemanager all required a ug_kf_execute license, will be resolved by code changes made to the upcoming release of our software NX 10. |
7118713 |
Siemens PLM believes that the problem you reported where the Limit/Fit tolerance specification is not available on the scene dialog for ASME/inch units will be resolved by code changes made to the upcoming release of our software NX 10. |
7118831 |
Siemens PLM believes that the problem you reported where the documentation for rough turn cut depth options are incorrect will be resolved by code changes made to the release of our product NX version 10. |
7118910 |
Siemens PLM believes that the problem you reported where cylindrical splitting causes the loss of mesh control and results in poor mesh will be resolved by code changes made to the upcoming release of our software NXV10.. |
7119037 |
Siemens PLM believes that the problem you reported where the Knowledge Fusion documentation needed to have more descriptive information on how the %ui_comp classes are intended to be used will be resolved by code changes made to the upcoming release of our software NX 10. |
7119039 |
Siemens PLM believes that the problem you reported where the Knowledge Fusion class %ui_comp_enum was missing from the documentation will be resolved by code changes made to the release of our product NX 10. |
7119432 |
Siemens PLM believes that the problem you reported where assembly constraints fail on patterned components, will be resolved by code changes made to the upcoming release of our software NX 10. |
7119755 |
Siemens PLM believes that the problem you reported where Save failure due to FCC error is an incorrect message for end user will be resolved by code changes made to the upcoming release of our software NX 10. |
7120322 |
Siemens PLM believes that the problem you reported where a Multi-line text block, which was part of a Row Column within a Group, was invisible (white on white with no outline), will be resolved by code changes made to the upcoming release of our software NX 10. |
7120364 |
Siemens PLM believes that the problem you reported where an Error is reported when dimensioning a Chamfer in a View with Breaks will be resolved by code changes made to the upcoming release of our software NX 10. |
7120779 |
Siemens PLM believes that the problem you reported where it is not possible to customize "Non-Cutting Moves" onto the main operation dialog for Floor/Wall Milling operations will be resolved by code changes made to the upcoming release of our software NX 10. |
7120916 |
Siemens PLM believes that the problem you reported where there is no documentation for the "Assumed Rapid Mode at Maximum Traversal Feed" option will be resolved by changes to our NX 10 documentation. If you select the Assumed Rapid Mode at Maximum Traversal Feed check box you get a G00 move instead of a G01 move during traversal motion when the feed rate is the maximum that the axes being moved can handle. Warning - Assumed Rapid Mode at Maximum Traversal Feed can cause a rapid dog-leg move during the traversal motion. Use it with extreme caution. |
7121129 |
Siemens PLM believes that the problem you reported where the Knowledge Fusion Navigator (KFNT) could not be reopened if it contained an attribute with an error will be resolved by code changes made to the upcoming release of our software NX 10. |
7121475 |
Siemens PLM believes that the problem you reported where the Tube feature Single Segment option is not building a correct tube will be resolved by code changes made to the upcoming release of our software NX 10. |
7121650 |
Siemens PLM believes that the problem you reported where the solution stopped with a FATAL message with a property ID >= 1,000,000 will be resolved by code changes made to the upcoming release of our software NX 10. |
7121712 |
Siemens PLM believes that the problem you reported where a drawing and assembly always opened as modified after Save All, will be resolved by code changes made to the release of our product NX 10. In order for the expectation in this case that parts not be marked as modified-on-load to be realized, it is necessary to refile the parts in the current NX release, so that part conversion processing, which upgrades the parts from previous release levels to the current release (and quite appropriately marks parts modified based on part conversion modifications made to the parts), should be performed. The NX utilities 'refile_part' and 'ugmanager_refile program' are provided to support this refiling in native and managed mode, respectively. |
7121842 |
Siemens PLM believes that the problem you reported where users were presented with a misleading message: "UGII_UGSOLIDS_TMP has filled up", will be resolved by code changes made to the upcoming release of our software NX 10. |
7122419 |
Siemens PLM believes that the problem you reported where NX clone from Teamcenter using cloneobject.AddAssembly fails for an object without an NX dataset will be resolved by code changes made to the upcoming release of our software NX 10. |
7122498 |
Siemens PLM believes that the problem you reported where it was not possible to create a 3-corner bend in all four corners using values the same as bend created, will be resolved by code changes made to the upcoming release of our software NX 10. |
7122547 |
Siemens PLM believes that the problem you reported where the user received an error messages "The record area asked for does not exist" while editing PMI, NX 10. |
7124482 |
Siemens PLM believes that the problem you reported where the created 3D swept mesh is incorrect will be resolved by code changes made to the upcoming release of our software NX 10. |
7125181 |
Siemens PLM believes that the problem you reported where weight value not generated even if 'Update Data on Save' is toggled on will be resolved by code changes made to the upcoming release of our software NX 10. |
7125196 |
Siemens PLM believes that the problem you reported where Text input into Command Finder is ignored when using the "Command Finder" button located next to the edit field will be resolved by code changes made to the upcoming release of our software NX 10. |
7125375 |
Siemens PLM believes that the problem you reported where a COM error is raised exiting spreadsheet will be resolved by code changes made to the upcoming release of our software NX 10. |
7125924 |
Siemens PLM believes that the problem you reported where a Trimmed surface from a Trimmed Body does not update when the parent surface color changes will be resolved by code changes made to the release of our product NX 10. |
7126108 |
Siemens PLM believes that the problem you reported where 'Box All' selection of "Identify" command when used with 3D elements was not picking some internal elements/node, mostly which where sharing all of its element-face with some other element will be resolved by code changes made to the upcoming release of our software NX 10. |
7126163 |
Siemens PLM believes that the problem you reported where a datum feature symbol attached to a Feature Control Frame with a datum leader did not maintain the attachment relationship properly will be resolved by code changes made to the upcoming release of our software NX 10. |
7126165 |
Siemens PLM believes that the problem you reported where the Tool Database will not convert to the new version and generates a signal 11 error will be resolved by code changes made to the release of our product NX 10. |
7126251 |
Siemens PLM believes that the problem you reported where spreadsheet from 'Identify' dialog did not list all nodes of TET10 elements will be resolved by code changes made to the upcoming release of our software NX 10. |
7126272 |
Siemens PLM believes that the problem you reported where exporting out universal file to a network location taking very long time to complete will be resolved by code changes made to the upcoming release of our software NX 10. |
7126320 |
Siemens PLM believes that the problem you reported where the Cavity Mill operation cuts too many levels will be resolved by code changes made to the NX 10 release of our product and is submitted for future MP release of NX 9.0.2 and NX 9.0.3. |
7127062 |
Siemens PLM believes that the problem you reported where the NX Dart functionality is corrupting NX models will be resolved by code changes made to the release of our product NX 10. |
7127220 |
Siemens PLM believes that the problem you reported where results manipulation does not allow the user to immediately load the results will be resolved by code changes made to the upcoming release of our software NX 10. A new toggle titled "Load Result Immediately" has been introduced to the output block of all result manipulation commands to enable import of result immediately. |
7127793 |
Siemens PLM believes that the problem you reported where Sequential Milling documentation incorrectly states that ball mills are not supported will be resolved by code changes made to the upcoming release of our software NX 10. |
7127872 |
Siemens PLM believes that the problem you reported where a Anchor Point on a Qualified part gives inconsistent placement results will be resolved by code changes made to the upcoming release of our software NX 10. |
7127921 |
Siemens PLM believes that the problem you reported where an extra drawing appeared when editing an empty booklet with KF rules defined in the dfa to pre-populate the Wizard with Primary Content, will be resolved by code changes made to the upcoming release of our software NX 10. |
7127939 |
Siemens PLM believes that the problem you reported where an Assembly Family member does not update the Assembly Pattern will be resolved by code changes made to the upcoming release of our software NX 10. |
7128534 |
Siemens PLM believes that the problem you reported where a Datum CSYS from a component could not be selected, will be resolved by code changes made to the upcoming release of our software NX 10. |
7128778 |
Siemens PLM believes that the problem you reported where clearance analysis gave incorrect penetration depth values for some interferences, where bodies are nearly touching along areas of gentle curvature, will be resolved by code changes made to the upcoming release of our software NX 10 and the next available maintenance pack for NX 9.0.3. |
7128791 |
Siemens PLM believes that the problem you reported where Clearance Analysis incorrectly measured Penetration Depth all the way "to the end" of an interfering body, for some cases where bodies are nearly touching along areas of gentle curvature, will be resolved by code changes made to the upcoming release of our software NX 10 and the next available maintenance pack for NX 9.0.3. |
7129485 |
Siemens PLM believes that the problem you reported where the Knowledge Fusion documentation did not explain that search folders are not read from the NX registry when working in batch mode will be resolved by documentation changes made to the upcoming release of our software NX 10. |
7130245 |
Siemens PLM believes that the problem you reported where the information about using "Legacy Replacement Routines" seemed to be missing from the Open C API Programmer's Guide will be resolved by documentation changes made to the upcoming release of our software NX 10, where the information has been relocated to make it easier to find. |
7130602 |
Siemens PLM believes that the problem you reported where a PMI Datum Feature Symbol located the "Origin Tool" X/Y Character Offset stub incorrectly will be resolved by code changes made to the upcoming release of our software NX 10. |
7131002 |
Siemens PLM believes that the problem you reported where deleting welds when using Manual Checkout and NX Checkout raises an error will be resolved by code changes made to the release of our software NX 10. |
7131096 |
Siemens PLM believes that the problem you reported where the Open C file uf_legacy_source.txt had multiple compile warnings and failed to build will be resolved by code changes made to the upcoming release of our software NX 10. |
7131181 |
Siemens PLM believes that the problem you reported where NXOpen > RuleManager > GetNameChain does not work with instances of a custom KF class which creates multiple objects will be resolved by code changes made to the upcoming release of our software NX 10. |
7131556 |
Siemens PLM believes that the problem you reported where GetCommittedObjects does not return a created named group for the PartImporter builder will be resolved by code changes made to the upcoming release of our software NX 10. |
7131649 |
Siemens PLM believes that the problem you reported where attempting to open this NX 7.5 assembly in NX 8.5 fails with an Internal error due to an assembly sequence issue will be resolved by code changes made to the upcoming release of our software NX 10.The part corruption was caused by failing to convert pre-NX 3 sequence steps in part files to modern sequence steps. This corruption would have occurred because parts were partially loaded in a previous (post-NX 2) release and the sequences and sequence steps were unloaded and so not available for conversion. The part files could then be saved, and the opportunity to perform sequence step conversion was missed. This is now anticipated, and sequence steps are converted even if the last saved release was later than NX 2. |
7132313 |
Siemens PLM believes that the problem you reported where Updating a Harness raised an Internal Error, will be resolved by code changes made to the upcoming release of our software NX 10. |
7133979 |
Siemens PLM believes that the problem you reported where Simple Radius or Simple Diameter shows incorrect options in the dialog will be resolved by code changes made to the upcoming release of our software NX 10. |
7134411 |
Siemens PLM believes that the problem you reported where the Feed Rate OK button is not active after changing the feed rate value will be resolved by code changes made to the upcoming release of our software NX 10. |
7134547 |
Siemens PLM believes that the problem you reported where the NXOpen.Features > MirrorFeature methods GetBodies and GetFaces did not work will be resolved by code changes made to the upcoming release of our software NX 10. |
7134956 |
Siemens PLM believes that the problem you reported where "MB3-> Component Properties-> Info lists the incorrect layer will be resolved by code changes made to the upcoming release of our software NX 10. |
7135242 |
Siemens PLM believes that the problem you reported where there is a performance issue using 'Edit Object Display' to change the work part color will be resolved by code changes made to the upcoming release of our software NX 10. |
7136122 |
Siemens PLM believes that the problem you reported where the translator failed to read a Catia V5 R23 SP2 HotFix file, will be resolved by code changes made to the upcoming release of our software NX 10. The fix will also be propagated into Maintenance Patches (to the degree possible) from NX 8.0.3 MPx to NX 9.0.2 MPx. |
7136654 |
Siemens PLM believes that the problem you reported where a sketch has conflicting constraints after editing an expression, will be resolved by code changes made to the upcoming release of our software NX 10. |
7137941 |
Siemens PLM believes that the problem you reported where the Child feature of Linked Expressions doesn't show out of date status will be resolved by code changes made to the upcoming release of our software NX 10. |
7138279 |
Siemens PLM believes that the problem you reported where Minimum Distance reports wrong value for a particular point, but are correct for other points in similar location, will be resolved by code changes made to the upcoming release of our software NX 10. |
7139292 |
Siemens PLM believes that the problem you reported where a UDF containing a measurement reported incorrect values will be resolved by code changes made to the upcoming release of our software NX 10. NX 9 works the same as NX 8.5 in this case. You have many kinds of UDFs where the measurement expressions are exposed as a UDF expressions. Such expressions are indeed output expressions and depend upon the actual UDF geometry to be created on the fly, and they are *not* supposed to be exposed as input expressions. NX contains an environment variable : UGII_UDFS_DISABLE_UI_EXPRESSION_COPY that allows the customer to revert back to the old expression copy behavior. Please set this env variable to 1, so that your UDFs with these output expressions will still work. With this variable set, the only thing you will lose is that upon UDF insert, you cannot use embedded measurements for the exposed input expressions. In NX 10, we added more code to automatically check for such cases as this, and then setting UGII_UDFS_DISABLE_UI_EXPRESSION_COPY will not be necessary. |
7140044 |
Siemens PLM believes that the problem you reported where Turning tool path losses cut region when trying to generate in NX 8.5 will be resolved by code changes made to the upcoming release of our software NX9.0.3 |
7140137 |
Siemens PLM believes that the problem you reported where the Open C API function UF_DRAW_redefine_sxline_hinge and its wrapper method NXOpen.UF > UFDraw > RedefineSxlineHinge fail with a memory access violation will be resolved by code changes made to the upcoming release of our software NX 10. |
7140732 |
Siemens PLM believes that the problem you reported where a performance regression was observed when inserting a Custom Symbol that included an Area Fill, will be resolved by code changes made to the upcoming release of our software NX 10. |
7140778 |
Siemens PLM believes that the problem you reported where Offset in Face Curve is gapped in NX 9.0.2 will be resolved by code changes made to the upcoming release of our software NX 10. |
7141090 |
Siemens PLM believes that the problem you reported where a message was received that said "attempt to save bad pointer, save aborted" when using laminates and attempting to save will be resolved by code changes made to the upcoming release of our software NX 10. |
7141247 |
Siemens PLM believes that the problem you reported where Arrangements are out of sync between Structure Manager and NX/MGR. There are missing arrangements in the structure manager that are in NX/MGR, and vise-verse, will be resolved by code changes made to the upcoming release of our software NX 10. |
7141264 |
Siemens PLM believes that the problem you reported where the documentation for RotateVector does not mention that the result will be unitized will be resolved by code changes made to the upcoming release of our software NX 10. |
7142030 |
Siemens PLM believes that the problem you reported where the NXOpen.Drawings > SectionLineBuilder > HingeDirection is not associative in specific cases will be resolved by code changes made to the upcoming release of our software NX 10. |
7142999 |
Siemens PLM believes that the problem you reported where "NX Sheet Metal - Contour Flange - Unable to create Flat Pattern from Tangent" will be resolved by code changes made to the upcoming release of our software NX 10. |
7143025 |
Siemens PLM believes that the problem you reported where arrowheads on PMI symbols do not resize will be resolved by code changes made to the release of our software NX 10. |
7143086 |
Siemens PLM believes that the problem you reported where you are unable to Save if the Item name does not match the case of the value in the LOV, will be resolved by code changes made to the upcoming release of our software NX 10.The Workaround for this PR is to pick Attributes button on the File New dialog and set the part name using the LOV dropdown. |
7143122 |
Siemens PLM believes that the problem you reported where the format of the information window is incorrect for element information will be resolved by code changes made to the upcoming release of our software NX version 10. |
7143639 |
Siemens PLM believes that the problem you reported where the symbolic thread depth is not honoring the value in the thd_english.dat or the thd_metric.dat, will be resolved by code changes made to the upcoming release of our software NX 10. |
7143732 |
Siemens PLM believes that the problem you reported where TURNING- operation dropping Clean Up Feedrate when generated in NX 8.5.3. MP3 will be resolved by code changes made to the release of our product NX 10. |
7144009 |
Siemens PLM believes that the problem you reported where the user was allowed to edit a Drawing Booklet without write access, will be resolved by code changes made to the upcoming release of our software NX 10. |
7144030 |
Siemens PLM believes that the problem you reported where Editing the Work Piece causes the default values to come back to the dialog when editing again will be resolved by code changes made to the upcoming release of our software NX 10. |
7144212 |
Siemens PLM believes that the problem you reported where the number of NX Drawing Sheets changes when orienting the view during view addition will be resolved by code changes made to the upcoming release of our software NX 10. |
7144620 |
Siemens PLM believes that the problem you reported where TURNING-Rough Bore ID- not recognizing all of cut region will be resolved by code changes made to the upcoming release of our software NX 10. |
7144791 |
Z-Level:tool cuts on both sides of edge extension. |
7144878 |
Siemens PLM believes that the problem you reported when plotting PCOMP ply stresses, the dialog changes from 11 to XX (etc.) will be resolved by code changes made to the upcoming release of our software NX 10. |
7144880 |
Siemens PLM believes that the problem you reported where Trim Body incorrectly raised the message: "The tool and target do not form a complete intersection", will be resolved by code changes made to the release of our product NX 10. |
7145277 |
Siemens PLM believes that the problem you reported where a PTS file is not behaving the same in Native as in TC, will be resolved by adding a topic in the Reuse Library Tech Documents in NX 10 that specifies the need to re-save a Product Template Studio object in Teamcenter before it can be retrieved from the reuse library and recognized as a PTS template. |
7145334 |
Siemens PLM believes that the problem you reported where rolled shape part fails to flat as solid due to the error, "Unable to create body", will be resolved by code changes made to the upcoming release of our software NX 10. |
7145772 |
Siemens PLM believes that the problem you reported where the NXOpen.GeometricUtilities > PartModuleInputBuilder class did not return the feature that was created by the call to Commit, will be resolved by code changes made to the upcoming release of our software NX 10. |
7146078 |
Siemens PLM believes that the problem you reported where the Max Shell Stress is incorrect on output and Combination is switching XX and YY will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 10.. There is a slight change with how shell minimum and maximum will be calculated. it will now always show absolute minimum or maximum. The Absolute toggle down in the dialog is actually showing the absolute value of obtained result in case of tensor component. And to use absolute value of the tensor component to obtain derived component or just the absolute value of the derived component depending on user choice. |
7148508 |
Siemens PLM believes that the problem you reported where the Open C API function UF_MISC_set_program_name did not seem to work in interactive NX mode has been investigated and was found to be a misrepresentation of the actual design of the method in the documentation. This problem will be resolved by documentation changes made to the upcoming release of our software NX 10.To set the main menubar text as desired use a menuscript file with the keyword TITLE. |
7148872 |
Siemens PLM believes that the problem you reported where the "Coolant Through" option on the tool dialog was not documented will be resolved by code changes made to the upcoming release of our software NX 10. |
7149531 |
Can't edit a Port. |
7149598 |
Can't modify extension length on Port in Qualify Part. |
7149734 |
Siemens PLM believes that the problem you reported where Saving assemblies that contain Machinery Library files "Thrust Brg, Cyl Rollers" or "Hvy Hex Structural" raise Save Warning "No write access", will be resolved by code changes made to the upcoming release of our software NX 10.The root cause was that it can't find the krx file because of the space in the end of file name. The workaround is to edit the File names, there is a Space between the letters "AI" and the .prt, .krx & .bmp, manually edit the filenames and remove that space. Then edit the KRX file and Remove the Spaces. |
7150049 |
Siemens PLM believes that the problem you reported where generating a Cavity Mill operation produces an "Internal error" will be resolved by code changes made to the upcoming releases of our software NX 9.0.3 and NX 10. |
7150147 |
Siemens PLM believes that the problem you reported where using a blank template when sending an empty ItemRev or NX dataset to NX, will always create a part by the default units will be resolved by code changes made to the upcoming release of our software NX 10. |
7151435 |
Siemens PLM believes that the problem you reported where engage and retract feed rates in a sequential mill operation are converted to rapids will be resolved by code changes made to the upcoming release of our software NX 10. Sequential milling will now output non-cutting feedrates correctly instead of outputting them as RAPID motions. |
7151655 |
Siemens PLM believes that the problem you reported where Hidden Component displays in a Drawing view with a PMI Light Weight Section view, will be resolved by code changes made to the upcoming release of our software NX 10.0 Problem Statement - Hidden component in PMI LWSV is not getting hide in imported PMI LWSV. Isuse - Cut component is not allowed to be hidden in a PMI LWSV and imported PMI LWSV. In imported PMI LWSV we are not allowing the selection of actual cut components from imported PMI LWSV. But this was missing in PMI LWSV. The Fix - Actual cut components are not allowed to be hidden from PMI LWSV. After this fix the user will not able to pick cut component from model PMI LWSV and hence the behavior in an imported LWSV will be consistent with PMI LWSV. |
7152069 |
Siemens PLM believes that the problem you reported where the NX9 documentation still contained information on the "Ignore Loops" option which was removed from the software will be resolved by code changes made to the release of our product NX 10. |
7152625 |
Siemens PLM believes that the problem you reported where the Copy with Reference utility causes Drilling Operations to go out-of-date will be resolved by code changes made to the release of our product NX 10. |
7152801 |
Siemens PLM believes that the problem you reported where running the Check-mate welding test sometimes caused an attribute with the wrong title to be defined for the part material will be resolved by code changes made to the upcoming release of our software NX 10. |
7152822 |
Siemens PLM believes that the problem you reported where Balloon size can be set to zero in the Balloon dialog, will be resolved by code changes made to the upcoming release of our software NX 10. |
7154027 |
Siemens PLM believes that the problem you reported where attempting to add a Fillet weld raises the error "Could not create weld sheet curves" OR "Could not construct faces from the offset Curves", will be resolved by code changes made to the upcoming release of our software NX 10.This test case is very problematic in that the offset is in a degenerate condition for the elliptical area of the fillet wall intersections. The process for cleaning up the internal offsets will be governed by how well the Offset in Face deals with the curve and can be manually applied to review any curve offset issues that might arise to better understand the internal conditions. |
7154392 |
Siemens PLM believes that the problem you reported where graphics for time varying pressure loads are incorrect will be resolved by code changes made to the upcoming release of our software NX version 10. |
7154765 |
Siemens PLM believes that the problem you reported where the Thread Depth pull down menu on the Hole dialog did not represent the selected Helicoil Coil size, will be resolved by code changes made to the upcoming release of our software NX 10. |
7155158 |
Siemens PLM believes that the problem you reported where Centroid should be volumetric only, not affected by Material for measure bodies will be resolved by upcoming release of our software NX 10 via code changes made below: Currently, NX does not calculate the centroid, it only calculates center of mass. So calculation result is incorrectly using centroid for the field label in the Information window. In many cases the centroid and center of mass are the same, but as this example provided, points out this is not always true so NX were wrong to use the term centroid. For NX 10, the Centroid heading in the Information will be changed to Center of Mass to avoid this incorrectly use of term. |
7155199 |
Siemens PLM believes that the problem you reported where the Remark for the method NXOpen.Annotations > AssociativeText > GetObjectPropertyText was incorrect will be resolved by code changes made to the upcoming release of our software NX 10. |
7156229 |
Siemens PLM believes that the problem you reported where corrections to the Plunge Milling Documentation on Maximum Cut Width are needed will be resolved by code changes made to the upcoming release of our software NX 10. |
7156997 |
Siemens PLM believes that the problem you reported where Hidden Line activation removed View Dependent Edits, will be resolved by code changes made to the release of our product NX 10. |
7157604 |
Siemens PLM believes that the problem you reported where setting units to lbm-ft results in incorrect Longitudinal Y-Frames and Z-Frames, will be resolved by code changes made to the upcoming release of our software NX 10. |
7158580 |
Siemens PLM believes that the problem you reported where trim body fails will be resolved by code changes made to the release of our product NX version 10. |
7158762 |
Siemens PLM believes that the problem you reported where PK_TOPOL_delete_redundant failed will be resolved by code changes made to the upcoming release of our software NX 10. |
7159323 |
Siemens PLM believes that the problem you reported where a PMI Radial Dimension improperly showed limits on the quantity of holes and improperly showed bilateral tolerance on the quantity and the "THRU" text, will be resolved by code changes made to the upcoming release of our software NX 10. |
7159352 |
Siemens PLM believes that the problem you reported where FLOOR WALL operation is giving an error "the handle is invalid" will be resolved by code changes made to the upcoming release of our software NX 9.0.3 mp1 and NX 10. |
7159379 |
Siemens PLM believes that the problem you reported where you received error, "Given object does not have the required csys matrix" to create angular dimension will be resolved by code changes made to the upcoming release of our software NX 10.0 This issue would result in an error stating that the object did not have a matrix and was specific to angular dimension to the extension of another non-angular dimension. |
7159399 |
Siemens PLM believes that the problem you reported where documentation for the Thread Milling option "From Table" does not state what table is used or where it is located will be resolved by code changes made to the upcoming release of our software NX 10. |
7159487 |
Siemens PLM believes that the problem you reported where information about the effect of the Key Field option on a parts list with packed rows will be resolved by code changes made to the release of our product NX version 10. A procedure was added that shows how to unpack a parts list, and information about the Key Field option was added to the definition of "Packed and unpacked rows" in the "Parts list concepts" topic. |
7159529 |
Spreadsheet EVALCRV results are incorrect on extracted curve. |
7160199 |
Siemens PLM believes that the problem you reported where, updating section view with break, moves annotation, will be resolved by code changes made to the upcoming release of our software NX 10. |
7160656 |
Siemens PLM believes that the problem you reported where export part produces an internal error, will be resolved by code changes made to the upcoming release of our software NX 10. |
7161187 |
Siemens PLM believes that the problem you reported where Gateway::PasteBuilder::GetCommittedObjects() was returning data (Borders and Zones entities) that was not pasted will be resolved by code changes made to the upcoming release of our software NX 10. |
7162820 |
Siemens PLM believes that the problem you reported where it is not possible to remove a stub after the Datum Feature symbol has been modified will be resolved by code changes made to the upcoming release of our software NX 10. |
7162921 |
The problem where revolved solid does not update to sketch topology is fixed in release NX 10. *** Date & Time: 05-aug-2014 23:20:20 User: LI, XIUCHANG (lixiu) *** |
7162947 |
Siemens PLM believes that the problem you reported where perpendicular dimension gets created to the mid-point will be resolved by code changes made to the upcoming release of our software NX 10. |
7163019 |
Siemens PLM believes that the problem you reported where the Report Shortest Tool option gives different results with stepover on 'Plane' vs on 'Part' will be resolved by code changes made to the upcoming release of our software in NX 10. |
7163049 |
Siemens PLM believes that the problem you reported where geometry in a view was automatically hidden when the view was inserted, will be resolved by code changes made to the upcoming release of our software NX 10. |
7163122 |
Siemens PLM believes that the problem you reported where a case sensitive comparison to "Method" in createDynamicRule causes a syntax error will be resolved by code changes made to the upcoming release of our software NX 10.17. |
7163422 |
Siemens PLM believes that the problem you reported where running a journal that sets or edits user defined events in a generic motion control operation does not work will be resolved by code changes made to the release of our product in NX 10 and NX 9.0.3 MP 2. |
7163430 |
Siemens PLM believes that the problem you reported where the Butt Weld cannot be built on two plates with a common hole will be resolved by code changes made to the upcoming release of our software NX 10. |
7163642 |
Siemens PLM believes that the problem you reported where receiving "Attempt to free already free memory in Storage Manager" when Canceling out of the Check Wall Thickness dialog, will be resolved by code changes made to the upcoming release of our software NX 10. |
7163658 |
Siemens PLM believes that the problem you reported where user defined constraints are changed on edit in a sim part with non-standard default units will be resolved by code changes made to the upcoming release of our software in NX Advanced Simulation, version 10. |
7164136 |
The problem where creating tool fields are slightly cut off on the right side of a specific platform is resolved in NX 10. |
7164390 |
Siemens PLM believes that the problem you reported where NX temporarily hung when pre-highlighting and un-highlighting components in large, partially loaded, exact, multi-level assemblies, will be resolved by code changes made to the upcoming release of our software NX 10. |
7164702 |
Siemens PLM believes that the problem you reported where a Datum Feature symbols origin changes when view changes, will be resolved by code changes made to the upcoming release of our software NX 10. |
7164758 |
Siemens PLM believes that the problem you reported where the new QT integrated browser in NX required multiple authentications each time NX was restarted, will be resolved by code changes made to the upcoming release of our software NX 10. A single authentication will only be required now, but must be entered each time a new session is started and the browser is opened. |
7166601 |
Siemens PLM believes that the problem you reported where the Ansys input file exported out of NX has the header specified as "FOR ANSYS VERSION 14.5", even though starting NX 9.0.2, Advanced Simulation now supports Ansys v15, will be resolved by code changes made to the upcoming release of our software NX9.0.4 and NX 10. "The ANSYS version in the banner will now depend on the environment variable UGII_ANSYS_VERSION or User Specified in "Solver Parameters" dialog instead of being hard-coded to ANSYS 14.5 in the versions upto NX 9.0.3. |
7166668 |
Siemens PLM believes that the problem you reported where a revolved solid does not update to new sketch topology, will be resolved by code changes made to the upcoming release of our software NX 10. |
7166681 |
Siemens PLM believes that the problem you reported where reusable object created result in user defined expression name lost will be resolved by code changes made to the release of our product NX version 10. |
7166700 |
Siemens PLM believes that the problem you reported where Drafting::SettingsManager::ProcessForMutipleObjectsSettings is spelled wrong will be resolved by code changes made to the upcoming release of our software NX 10. |
7166968 |
Siemens PLM believes that the problem you reported where un-preselecting can be sluggish when groups and or components are involved in the preselection, will be resolved by code changes made to the upcoming release of our software NX 10. |
7166982 |
Smart Lightweight view performance issues |
7167747 |
Siemens PLM believes that the problem you reported where View Dependent Edits were removed when Hidden Lines were removed, will be resolved by code changes made to the release of our product NX 10. |
7168009 |
Siemens PLM believes that the problem you reported where lines created in a drawing view are not view-dependent and they are displayed in Modeling will be resolved by code changes made to the release of our product NX9.0.3 MP2 and NX 10. |
7168049 |
Siemens PLM believes that the problem you reported where the NXOpen.UF > UFSf > createOffsetMidsrf Java wrapper for the legacy open C API method UF_SF_create_offset_midsrf aborted a batch application due to a fatal error when used in a specific part will be resolved by code changes made to the release of our software NX 10. We still recommend decreasing the cliff angle to 5 degrees for better results. |
7168410 |
Siemens PLM believes that the problem you reported where the Sketch Offset Curve auto-dimension location is always on XC-YC will be resolved by code changes made to the upcoming release of our software NX 10. |
7169022 |
Siemens PLM believes that the problem you reported where there were graphical display errors after assigning feature color will be resolved by code changes made to the upcoming release of our software NX 10. |
7169339 |
Siemens PLM believes that the problem you reported where Refile to volumes documentation note is misleading will be resolved by code changes made to the release of our product NX version 10. The -keep_volume switch has been reworked. |
7170346 |
NX: 'Move Face' does not keep vector option once object is selected. |
7170469 |
Siemens PLM believes that the problem you reported where NX crashed when doing 3D swept meshing will be resolved by code changes made to the upcoming release of our software NX 10. |
7170510 |
Siemens PLM believes that the problem you reported where the ExtractFaceBuilder property ObjectToExtract is not populated when using the NXOpen.Features > FeatureCollection > CreateExtractFaceBuilder to query an existing Linked Face feature will be resolved by code changes made to the release of our software NX 10. |
7170538 |
Siemens PLM believes that the problem you reported where the flute length display for bell centerdrill tools is incorrect will be resolved by code changes made to the upcoming release of our software NX 10. |
7170902 |
Siemens PLM believes that the problem you reported where Import plmxml file into Electrical Connection Navigator crashes NX, will be resolved by code changes made to the upcoming release of our software NX 10, and future releases of NX 9.0.2 and NX 9.0.3. |
7171582 |
Siemens PLM believes that the problem you reported where the NXOpen > Information > DisplayObjectsDetails method writes the attributes the given objects to the Information window (stdout in external mode) rather than the current listing device will be resolved by code changes made to the upcoming release of our software NX 10 and the next patch NX.9.0.3. |
7172223 |
Siemens PLM believes that the problem you reported where drag and drop of a part file into NX to Add Component using Copy option is not correct will be resolved by code changes made to the upcoming release of our software NX 10. |
7172340 |
Siemens PLM believes that the problem you reported where the help files pertaining to displaying nodes independently of elements needed some clarification, will be resolved by code changes made to the release of our product NX Advanced Simulation, version 10. |
7172660 |
Siemens PLM believes that the problem you reported where NX is NOT holding the applied Extension Length on the multiport will be resolved by code changes made to the release of our software NX 9.0.2 MP2, NX 9.0.3, & NX 10. |
7172867 |
Siemens PLM believes that the problem you reported where a component added to an assembly in managed mode session which is then restructured (cut/paste or drag/drop) before ever having saved the assembly fails to get its Relative Transformation Matrix set correctly in Teamcenter, will be resolved by code changes made to the upcoming release of our software NX version 10. The fix for this issue has also been submitted and is a candidate for the next HotFix on the NX version 9.0.1 branch. |
7173042 |
Siemens PLM believes that the problem you reported where an error is triggered when trying to delete a part boundary from a Planar Mill operation will be resolved by code changes made to the release of our product NX 9.0.3 MP1 and NX 10. |
7173079 |
Siemens PLM believes that the problem you reported where the stepover distance for a Fixed Axis Surface Contour operation is not updated by the Set Machining Data comma will be resolved by code changes made to the release of our product is fixed in NX 9.0.3 MP1 & NX 10. |
7173247 |
Siemens PLM believes that the problem you reported where Concave faces did not update to a new color when re-selected using the Concave Faces command a second time, will be resolved by code changes made to the upcoming release of our software NX 10. |
7173250 |
Siemens PLM believes that the problem you reported where a message was received about Frozen Data Error during volume meshing will be resolved by code changes made to the release of our product NX version 10.0. Please delete existing meshes that butt against the problem area, re-mesh and then mesh the body of interest. To realize the fix, please delete frozen meshes (32 and 34), recreate mesh 34 at size 5, then recreate mesh 32. Everything will work fine. There are no issues with saving the fem and any other checks at this point. |
7173268 |
Siemens PLM believes that the problem you reported where sketch points move to the origin of the part after a Flat Solid will be resolved by code changes made to the upcoming release of our software NX 10. |
7173298 |
Siemens PLM believes that the problem you reported where NX9 took much longer than NX 8.5 to update Pattern features, will be resolved by code changes made to the release of our product NX 10. |
7173299 |
Siemens PLM believes that the problem you reported where small DIM1 values yield incorrect torsional constant (ZERO) will be resolved by code changes made to the upcoming release of our software NX version 10. |
7173639 |
Siemens PLM believes that the problem you reported where the NXOpen.Annotations > DisplayPmiEffectivityMethod Enumeration used the wrong values will be resolved by code changes made to the release of our software NX 10. |
7173660 |
Siemens PLM believes that the problem you reported where the Concave Faces dialog displayed inch radius values as millimeter, will be resolved by code changes made to the upcoming release of our software NX 10. |
7173726 |
Siemens PLM believes that the problem you reported where a PMI Lightweight Section View does not clip symbolic threads in an assembly, will be resolved by code changes made to the release of our software NX 10. |
7173754 |
Siemens PLM believes that the problem you reported where mapped NX attributes do not propagate to part family member parts, will be resolved by code changes made to the upcoming release of our software NX 10. |
7174337 |
Siemens PLM believes that the problem you reported where Checkout --> Both is not available even though the DE and the source item are checked in, will be resolved by code changes made to the upcoming release of our software NX 10. |
7174413 |
The problem where manifestation created after UF_UI_ugmgr_ask_create_part_file_name fails to save is fixed in release NX 10.0 |
7174452 |
Siemens PLM believes that the problem you reported where there was a 10 character limit in expression names will be resolved by code changes made to the release of our product NX 10. |
7174462 |
Siemens PLM believes that the problem you reported where there was an undocumented 10 character limit only in the results reduction form will be resolved by code changes made to the upcoming release of our software NX 10. After this change, there is still a maximum expression length of 239 characters. |
7174884 |
Siemens PLM believes that the problem you reported where changing the Graduated Background color in a part fails to change the part to a "Modified" state will be resolved by code changes made to the upcoming release of our software NX 10. |
7175298 |
Siemens PLM believes that the problem you reported where the Check-Mate documentation needed an explanation of how to log different severity levels will be resolved by documentation changes made to the release of our product NX 10. |
7175565 |
Siemens PLM believes that the problem you reported where NX incorrectly allows creation of 1D elements, using 'Element Create' command, with just 1 node will be resolved by code changes made to the upcoming release of our software NX 10. |
7176007 |
Siemens PLM believes that the problem you reported where a journal recorded while checking the mass properties of bodies could not be replayed due to the use of a selection collector for the input entities will be resolved by code changes made to the upcoming release of our software NX 10. |
7176044 |
Siemens PLM believes that the problem you reported where the Open C function UF_CURVE_ask_offset_direction_2() incorrectly returns zeroes for the Offset Direction will be resolved by code changes made to the upcoming release of our software NX 10. |
7176051 |
Siemens PLM believes that the problem you reported where in a particular part editing a sketch causes NX session to crash will be resolved by code changes made to the upcoming release of our software NX 10. To access this fix, first do part cleanup for drafting objects on the part and this will resolve the issue so the sketch can be edited. A cleanup/repaired version of the NX part file has been made available based on client's current NX version. |
7176593 |
Siemens PLM believes that the problem you reported where a part file from NX8.0 cannot in NX 9.0.2 causes internal error will be resolved by code changes made to the upcoming release of our software NX 9.0.3 MP1 and NX 10. |
7176656 |
Siemens PLM believes that the problem you reported where journal playback of the Edit Length Measure Feature produces no results and no errors will be resolved by code changes made to the upcoming release of our software NX 10 phase 20. The journal is missing the actual edit. VB example: workPart.MeasureManager.EditLength (measure1, measureDistanceBuilder1.LengthCollector). |
7176954 |
Siemens PLM believes that the problem you reported where the documentation for the Open C function UF_ASSEM_set_work_part_quietly() did not clearly state that it should not be used with Advanced Simulation will be resolved by code changes made to the upcoming release of our software NX 10. |
7177188 |
Can't create desired face blends between two sheets. |
7177665 |
Siemens PLM believes that the problem you reported where NX9.0 getcid.exe reported incorrect CID values, will be resolved by code changes made to the release of our software, Siemens PLM Licensing V6.4. The latest getcid.exe can be downloaded from the GTAC web site: - Go to http://www.siemens.com/gtac - Select Download and Upload files - Select Download files - Login with your WebKey account and password - On the Product Updates' row, select the pull-down menu and select 'Siemens PLM Licensing' - Select the folder 'CID' - Select wntx64 - Download: getcid.exe. |
7177807 |
Siemens PLM believes that the problem you reported where Hidden Lines set to Invisible removed View Dependent Edits, will be resolved by code changes made to the release of our product NX 10. |
7177815 |
Siemens PLM believes that the problem you reported where 24-bit bitmap files were not found when a User Tool Definition file (.utd) specified the name using a relative path will be resolved by code changes made to the release of our product NX 10. |
7177838 |
Siemens PLM believes that the problem you reported where Importing expressions is very slow if formula uses a large size excel file will be resolved by code changes made to the upcoming release of our software NX 10. "The problem reported is a timeout for the COM interface to external programs like Excel, and then COM is putting up all of the error messages and dialogs. For NX 10, development changed the length of the timeout to allow for larger spreadsheets, or spreadsheets on mounted drives to be loaded without causing problems. Development also suppressed the warning dialogs from COM and allow them to default where it will continue to load." This was a very base level change to how NX deals with all COM interfaces, thus is not considered by development to risk backporting to any NX 9 patch at this point due to unknown negative side effects might happen. |
7178728 |
Siemens PLM believes that the problem you reported where section numbers for beams and shells are repeated in the exported Ansys input deck will be resolved by code changes made to the release of our product NX version 10. Also, please note the ID conflict is resolved but the unused Physical Properties are still exported. The enhancement is planned for future release of NX. |
7178894 |
Siemens PLM believes that the problem you reported where object automatically removed from reference set after show or hide operation will be resolved by code changes made to the release of our product NX version 10. |
7179210 |
Siemens PLM believes that the problem you reported where the leader of a datum symbol changed when trying to change the style, will be resolved by code changes made to the release of our software NX 10. |
7179438 |
Siemens PLM believes that the problem you reported where NX Part attributes still behaved like synchronized attributes having removed the synchronization definition from the NX to Teamcenter attribute mappings, will be resolved by code changes made to the upcoming release of our software NX 10.0 and via an NX 8.5.3 MP5 customer patch. |
7179870 |
Siemens PLM believes that the problem you reported where a C# Journal created in NX 7.5 fails in NX 9 because a structure is not fully initialized will be resolved by code changes made to the upcoming release of our software NX 10.18. |
7179969 |
Siemens PLM believes that the problem you reported where Check-Mate, Check Feature Rollback fails unexpectedly will be resolved by code changes made to the release of our product NX 10. |
7180484 |
Siemens PLM believes that the problem you reported where the documentation for RuleManager.getDynamicRules() was misleading will be resolved by code changes made to the upcoming release of our software NX 10. |
7180507 |
Arrangements are out of Synch between NX/Mgr and Structure Manager. |
7180660 |
Siemens PLM believes that the problem you reported where documentation incorrectly states that you can specify a negative "top Offset" distance will be resolved by code changes made to the release of our product is fixed in NX 9.0.3 MP1 and NX 10.Added documentation caveat to NX 9.0.3. Updated option description in NX 10. |
7181024 |
Siemens PLM believes that the problem you reported where Edit Section settings raised the error: "Section line add arrow segment error", will be resolved by code changes made to the release of our product NX version NX 10. |
7181659 |
The problem where after running Connected Face Finder on Retained Welds, the Welds are fixed but the Weld CSYS is not normal to surface has been investigated and the following has been found. In NX 9.0.2 and NX 9.0.3, not all the faces are being gathered and presented for each Weld point on the Connected Face Finder dialog. This can be verified visually by selecting the Spot Weld entry in the Connected Face Finder -> Connections list and review the highlighted faces. To correct the issue, expand Spot Weld(15) and select each Connected Face Set (1&2). Notice that all faces have not been found. Add the missing faces to each face set (from the appropriate part), mark for save, and OK the dialog. Now when you check the Weld CSYS, it will be oriented correctly. This problem where the Connected Face Finder does not gather and present all the faces for each Weld Point has been fixed in release NX 10.Further development comments: The positions of the points are exactly ½ way between the 2 sheets, so as the analysis progresses from one point to the next, the faces change from one part to the next (and this actually may appear to be random). Currently, there is not a mechanism to correct this order in the situation that they have. So what does that mean, specifically for the PR parts. The faces found for the Weld Point is as follows (for my session): Weld "43100" Face Set 1 - Face from PART1 Face Set 2 - Face from PART2 Weld "43102" Face Set 1 - Face from PART2 Face Set 2 - Face from PART1 Weld "43104" Face Set 1 - Face from PART2 Face Set 2 - Face from PART1 The user can visually see this by toggling OFF the List Feature Sets, rerun the Analysis, and then review the faces selected in the Connections list. When listing by Feature Sets, the final step (before presenting the data to the user) is to gather the faces for each set. Connected Face Finder has a rule at this stage though not to allow faces from differing parts into the same set. This results in the faces for Weld "43100" being kept and all others "thrown out". In NX 10, I have added an error code to make this issue a little more visible, but for NX 9x, there is no fix (it is not an open development release at this point). This requires the user to be diligent to verify faces selected, especially in these types of situation (I am assuming that they have replaced parts, or something similar to get the points in the positions that they are). In NX 9, the best course of action is to run Connected Face Finder and make sure the found faces are correct (re-selecting the proper ones if they are not). This will correct the point position and the Weld CSYS as needed. |
7182170 |
NO LETTER. This was a regression and the issue was corrected by an update to that patch which was delivered to the customer to resolve the issue. Later SFB 'NX-SFB-8431' was issued noting this was an issue not specific to the NNS HF patch. |
7182930 |
Siemens PLM believes that the problem you reported where the CopyDisplayInstanceObjects() API method failed with a serious error on PMI Regions will be resolved by code changes made to the upcoming release of our software NX 10. PMI Regions do not support the creation of multiple display instances and they are now properly excluded from processing via the CopyDisplayInstanceObjects() NXOpen function. |
7182935 |
Siemens PLM believes that the problem you reported where a thread was not showing correctly in detail view, will be resolved by code changes made to the release of our software NX 10. |
7182939 |
Siemens PLM believes that the problem you reported where radials and popup menus appear in the incorrect position when running with Windows text settings greater than 100% is fixed in release NX 9.0.3 and NX 10. |
7184108 |
Siemens PLM believes that the problem you reported where the UGOPEN\\uf_legacy_source.txt failed to compile when renamed to uf_legacy.c will be resolved by code changes made to the release of our software NX 10. |
7184161 |
Siemens PLM believes that the problem you reported where Importing Custom Welds Changes WELD_TYPE Attribute will be resolved by code changes made to the release of our software NX 10. |
7184596 |
Siemens PLM believes that the problem you reported where running "Replay" mode in Tool Path Visualization adds an additional "GOTO" move before the "GOHOME" move in a Turning operation will be resolved by code changes made to the releases of our product NX 9.0.3 MP2 and NX 10. |
7184777 |
Siemens PLM believes that the problem you reported where making a Sub-AFEM the Work Part causes a Signal 11 Error will be resolved by code changes made to the release of our product NX Advanced Simulation version 10. |
7185052 |
Siemens PLM believes that the problem you reported where an NX6 Grooving operation that finishes the back face on the PR part produces a retract that gouges the part geometry when generated in NX 8.5.3 MP6 will be resolved by code changes made to the release of our product NX8.5.3 MP7. For the fix to work you must have the following environment variable set: UGII_TURN_DIRECT_ENGAGE_AND_RETRACT_ALSO_IF_CONTAINMENT_HAS_TRIM_PLANES_ONLY=1 |
7185104 |
Siemens PLM believes that the problem you reported where a Multi-Layered Thin Shell does not update the layer order correctly will be resolved by code changes made to the release of our product NX version 10. |
7185392 |
Siemens PLM believes that the problem you reported where Running NX in Managed Mode, NX CAE can not export a SINDA 85 file will be resolved by code changes made to the release of our product NX version 10. |
7185716 |
Siemens PLM believes that the problem you reported where Finish Turn operations are reversed and not following the 'Angle from XC' from previous versions will be resolved by code changes made to the NX 10 release of our product. |
7185927 |
Siemens PLM believes that the problem you reported where Response Simulation had an incorrect RMS XX material stress for MAT8 shell elements will be resolved by code changes made to the release of our product NX version 10. |
7186261 |
Siemens PLM believes that the problem you reported where multiple Point locations are incorrect in a Post Builder Machine Control event will be resolved by code changes made to the release of our product version NX 10. |
7186425 |
Siemens PLM believes that the problem you reported where inconsistent exact/lightweight results were observed in the Assembly Navigator for NX components created from Ideas JT's, will be resolved by code changes made to the release of our product NX 10. |
7186697 |
Siemens PLM believes that the problem you reported where save as UGMASTER legacy NX3 part with drawing does not link to new ugmaster, will be resolved by code changes made to the release of our product NX 10. |
7186726 |
Siemens PLM believes that the problem you reported where a flipped User Defined Symbol on a Flag leader in NX7.5, shows up as two symbols in NX9 will be resolved by code changes made to the release of our product NX 10.0 The correct behavior is to show two symbols, first symbol before the flip option, and second symbol with the flip option. Due to a defect in the display of the symbols, only one symbol was getting displayed. This is resolved in NX9 to show both symbols; however, in NX9, the fix was applied automatically without versioning. In NX 10, if two symbols are present at one location, then only one symbol will be rendered until the user upgrades the version of the annotation. After the version upgrade, two symbols will be rendered properly, which again is the correct behavior. |
7186749 |
Siemens PLM believes that the problem you reported where editing a hidden Bridge Curve in NX 9 did not make it visible the same way as editing in NX 8 did, will be resolved by code changes made to the release of our product NX 10. |
7186799 |
Siemens PLM believes that the problem you reported where DOF sets will disappear when closing and reopening a model will be resolved by code changes made to the release of our product NX 10. |
7187838 |
Siemens PLM believes that the problem you reported where Teamcenter Display Rules used to hide dataset types caused an NX startup failure, will be resolved by code changes made to the release of our product NX 10 and the next available maintenance pack for NX 9.0.3. The fix will also been supplied in an NX 9.0.3 customer patch. |
7188498 |
Exact Clearance analysis gives extreme false positives. |
7188623 |
Show = False on a Tab Page hides container items rather than the Tab itself . |
7188965 |
Siemens PLM believes that the problem you reported where the error "No modes found" was issued during the creation of a response simulation will be resolved by code changes made to the release of our product NX version 10. |
7188978 |
Siemens PLM believes that the problem you reported where Insert Text From File not working for Note command in managed mode of NX 9.0.3 will be resolved by code changes made to the release of our product NX version 10. |
7189342 |
Siemens PLM believes that the problem you reported where performing a Create Eyellipse in Vehicle Design Automation failed with an error, will be resolved by code changes made to the release of our product NX 10. |
7189438 |
Siemens PLM believes that the problem you reported where Welds failed the MDM Consistency check, will be resolved by code changes made to the release of our product NX 10. |
7189441 |
Siemens PLM believes that the problem you reported where Mirror Weld created double welds when re-selected, will be resolved by code changes made to the release of our product NX 10 and NX 9.0.2 Rev D (customer patch). |
7189446 |
Siemens PLM believes that the problem you reported where the 'Weld Point -> Reference Sheet' dialog memory fails to retain its previous setting will be resolved by code changes made to the release of our product NX 10. The NX9 Weld Point dialog does not have dialog memory working for various options. In NX 10 the Weld Point dialog has been replaced by the Weld Point Wizard dialog. This dialog has full support of dialog memory for all options. |
7189460 |
Siemens PLM believes that the problem you reported where 'Bounded Plane' fails with the message, "Unable to reference edge", will be resolved by code changes made to the release of our product NX 10. |
7189803 |
Siemens PLM believes that the problem you reported where NX9 fails to start from Teamcenter will be resolved by code changes made to the release of our product NX 9.0.3 MP1. |
7191083 |
Siemens PLM believes that the problem you reported where selecting F1 on the Units Manager dialog resulted in an error rather than the contextual help will be resolved by code changes made to the NX 10.0 release of our documentation. |
7191389 |
Siemens PLM believes that the problem you reported where Annotation objects creating by a journal are not persistent, will be resolved by code changes made to the release of our product NX Advanced Simulation, version 10.0. |
7192041 |
Siemens PLM believes that the problem you reported where an object copied to a new layer disappears when the original layer is turned off will be resolved by code changes made to the release of our product NX 10. |
7192324 |
Siemens PLM believes that the problem you reported where inserting Text From File was not working for the Note command in managed mode of NX 9.0.3, will be resolved by code changes made to the release of our product NX 10. |
7195208 |
Siemens PLM believes that the problem you reported where Adding an Extrude Feature raised a Fatal error and crashed NX, will be resolved by code changes made to the release of our product NX 10. |
7199191 |
Siemens PLM believes that the problem you reported where the current docs do not explain about the blank distance needed when machining planar mill boundaries (islands) will be resolved by code changes made to the release of our product NX 10.Added topic - Cutting depth first around islands - Planar Mill with Profile cut pattern. Added Quick link to Analysis Tools documentation. |
7201232 |
Siemens PLM believes that the problem you reported where creating a child rule of the Knowledge Fusion class ug_odbc_database, using a DSN that did not exist, caused the NX session to become corrupt when the part was closed or the session was exited, will be resolved by code changes made to the release of our product NX 10. |
7203285 |
Siemens PLM believes that the problem you reported where the description of the 'Load All Defaults" on the Annotation Preferences and Annotation Style dialogs is not very descriptive will be resolved by document changes made to the release of our product NX 10. |
7205865 |
Siemens PLM believes that the problem you reported where the "Wrong Major Diameter is inherited from customized thd_metric.dat file" will be resolved by code changes made to the release of our product NX 10 IP16. |
7206965 |
Siemens PLM believes that the problem you reported where the Reuse Library was not accessible in Managed Mode when the library has the same name as defined in Native Mode will be resolved by code changes made to the release of our product NX 10. |
7208769 |
Siemens PLM believes that the problem you reported the documentation was incomplete for Cylindrical Dimensions, will be resolved by changes made to the documentation of our product NX 10.Information about the effect of selection order and centerlines on the creation of Cylindrical Dimensions is already fully described in the Drafting Help collection. Please see the topic entitled "Using centerlines to create cylindrical dimensions". A link was added to this topic from the Rapid Dimension dialog box topic. |
7208876 |
Siemens PLM believes that the problem you reported where The NXOpen Session class WriteLogFile method and the ListingWindow methods WriteLine and WriteFullline do not work with some UTF8 text will be resolved by code changes made to the release of our product NX version 10. |
7210772 |
Stress Wizard posts incorrect contour plots. |
7213307 |
Siemens PLM believes that the problem you reported where an operation is shown as out-of-date when generated from inside the operation will be resolved by code changes made to the release of our product NX 10. |
7214353 |
Siemens PLM believes that the problem you reported where electrode blank still needs blank_reg.xs4 to work will be resolved by code changes made to the release of our product NX version 10. |
7214402 |
Siemens PLM believes that the problem you reported where the GRIP documentation for the &DOLLIB and &EXCLIB GPAs needed to state that the environment variables UGII_LIB1 and UGII_LIB2 are used to set the folder paths which they return will be resolved by code changes made to the release of our product NX version 10. |
7217816 |
Siemens PLM believes that the problem you reported where patterns created by saving a part in a GRIP batch program after setting &PATFIL = &YES were blank will be resolved by documentation changes made to the release of our product NX 10. The documentation which stated that this was possible was wrong and has been corrected. Pattern are generated from the display and cannot be created in batch mode. |
7219643 |
Siemens PLM believes that the problem you reported where information that is critical to rearranging tool paths in a synchronized program was not documented will be resolved by code changes made to the release of our product NX 10. |
7219767 |
Siemens PLM believes that the problem you reported where Patterned components had duplicate suffixes incremented in one column of the Electrode Bill of Materials each time the BOM was reopened, will be resolved by code changes made to the release of our product NX 10.0 and the next available maintenance pack for NX 9.0.3. |
7221407 |
Siemens PLM believes that the problem you reported where the Electrode Design Bill Of Materials did not calculate the electrode instance's angles correctly will be resolved by code changes made to the release of our product NX 10. |
7222199 |
Siemens PLM believes that the problem you reported where NX9 and NX 10 documentation is still showing previous NX 8.5 options/functionality and missing updated information will be resolved by code changes made to the release of our product NX 10. |
7222603 |
GM Model Update issue in GM NX9.0.2.5 Rev C, 11Sep14. |
7227357 |
Error opening drawing - The planar face cannot be projected . |
7230234 |
Different weights reported when unroute/reroute in NX 8.5.3 mp6. |
7234318 |
%mqc_check_feature_tolerance doesn't find wrong tolerance of Trim Body. |
7238373 |
Internal error opening part and going to Part Navigator. |
7240328 |
Drawing View cannot update. |
7240401 |
Open Assembly and update drawing failed. |
8250223 |
Siemens PLM believes that the problem you reported where Through Curves Mesh inconsistent will be resolved by code changes made to the release of our product NX version 10. |
8250297 |
Siemens PLM believes that the problem you reported where "Associative Issue with "constant velocity" and "perpendicular" joints" will be resolved by code changes made to the release of our product NX version NX 10. |
8250506 |
Siemens PLM believes that the problem you reported where NX9 hangs in Adv Simulation when a part name version is set in customer defaults will be resolved by code changes made to the release of our product NX V10. |
8250552 |
The issue with this part where a crash would occur when attempting to edit the sketch has been fixed in NX 10. To access this fix, first do part cleanup for drafting objects on the part and this will resolve the issue so the sketch can be edited. |
8250934 |
Disappearing geometry from drawings after update views. |
8250999 |
Siemens PLM believes that the problem you reported where "Unable to delete Edge Blends "Deleted or Invalid ClassID"" will be resolved by code changes made to the release of our product NX 10 IP21 and later. The three failed Edge Blend features in the PR part can now be deleted as normal. |
8251109 |
Siemens PLM believes that the problem you reported where Deform operation cannot complete because features copy has failed will be resolved by code changes made to the release of our product NX 10. |
8251638 |
The problem where offset curve in face is self intersecting is fixed in release NX 10.Now insufficient quality curves are fixed in NX 10. It can be test with below steps: 1. open part file DAG56142.prt in NX 10.0.0.23; 2. Edit with rollback for offset in face(7) 3. Toggle on options trim to each other within section and extend to each other within section 4. Toggle on Advanced curve fit option. (use degree and tolerance with degree 7) Then Extrude(12) would be one sheet body. |
8251730 |
Siemens PLM believes that the problem you reported where Modeler error occurs doing "Make Current Feature" will be resolved by code changes made to the release of our product NX 10. |
8251843 |
Siemens PLM believes that the problem you reported where "Sketch-Time too long while working with active filter" will be resolved by code changes made to the release of our product NX version NX 10. |
8251900 |
Siemens PLM believes that the problem you reported where the following erroneous warning message is output by the 'model setup check' functionality to the nx 'information' window in the scenario where a model which includes a concentrated mass is subject to a gravity load: WARNING There are mass elements in the part, but no gravity or centrifugal loads. The mass elements will be ignored in the analysis. SUGGESTION: Apply a gravity or centrifugal load. will be resolved by code changes made to the release of our product NX 10. |
8252011 |
Additional, nonexisting edges are shown in the Visualisation Window. |
8252013 |
Siemens PLM believes that the problem you reported where Edge tolerances will be resolved by code changes made to the release of our product NX version 10. The edge tolerance problem has been fixed in NX 10. To get the fix, the Blend Corner (2) feature must be migrated to NX 10 or later release. One easy way to do the migration is to edit the Blend Corner feature and perform Show Result. |
8252081 |
Siemens PLM believes that the problem you reported where the value for the environment variable TEAMCENTER_SSL_CERT_FILE needs to be further documented is fixed in the documentation of release NX 10. |
8252250 |
Siemens PLM believes that the problem you reported where PTS freeze after open the file will be resolved by code changes made to the release of our product NX version 10. |
8252271 |
Siemens PLM believes that the problem you reported where corner blend tolerance overshooting will be resolved by code changes made to the release of our product NX version 10. The edge tolerance problem in Blend Corner feature is fixed in NX 10 release. To get the fix, the old features created prior to NX 10 must be migrated. One way to do the migration is to edit an Blend Corner feature and do Show Result. |
8253075 |
Siemens PLM believes that the problem you reported where the geometric constraint symbols are not visible in some sketches, will be resolved by code changes made to the release of our product NX version 10. A workaround to this issue is outlined below; 1. Make the sketch/layer visible. 2. Make the sketch active. 3. Select 'Edit -> Show and Hide -> Invert Shown and Hidden' (Keyboard shortcut = 'Ctrl+Shift+B') 4. Select 'Edit - Show and Hide - Show All' (Keyboard shortcut = 'Ctrl+Shift+U') The sketch constraints should now be visible. This workaround can be used all NX versions prior to NX 10. |
8253202 |
NX File Open with Assembly Part not possible. |
8253210 |
Dimension attached to sketch curve on drawing will not update. |
8253525 |
Trim Body fails after Feature Playback in NX 9. |
8253526 |
Trim and Extend fails after Feature Playback in NX 9. |
8253552 |
Correct localization is problem if Deviation letters list includes Cyrillic. |
8253668 |
Siemens PLM believes that the problem you reported where Save Operation fails after modification of a parameter in control sketcher will be resolved by code changes made to the release of our product NX version 10. |
8254374 |
Can't export dxf of drawing with flat pattern correctly. |
8254484 |
Drawing cannot open stand alone - Welding Symbol. |
8254650 |
Drawing cannot open stand alone - Datum Target. |